Sunteți pe pagina 1din 2

Product data sheet

Characteristics

RM35LM33MW

liquid level control relay RM35-L - 24..240 V AC/DC

Main
Range of product Product or component type Relay type Relay name Relay monitored parameters Time delay Switching capacity in VA Minimum switching current Maximum switching current Power consumption in VA Measurement range Electrical connection Zelio Control Modular measurement and control relays Level control relay RM35L Detection by resistive probes Adjustable 0,1...5 s +/- 10 % 1250 VA 10 mA 5 V DC 5 A AC/DC 5 VA AC 250 Ohm...1 MOhm 1 conductor cable 0,5...4 mm AWG20...AWG11 solid without cable end IEC 60947-1 1 conductor cable 0,2...2,5 mm AWG24...AWG12 flexible with cable end IEC 60947-1 2 conductors cable 0,5...2,5 mm AWG20...AWG14 solid without cable end IEC 60947-1 2 conductors cable 0,2...1,5 mm AWG24...AWG16 flexible with cable end IEC 60947-1 AC-12 IEC 60947-5-1 AC-13 IEC 60947-5-1 AC-14 IEC 60947-5-1 AC-15 IEC 60947-5-1 DC-12 IEC 60947-5-1 DC-13 IEC 60947-5-1
The information provided in this documentation contains general descriptions and/or technical characteristics of the performance of the products contained herein. This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications. It is the duty of any such user or integrator to perform the appropriate and complete risk analysis, evaluation and testing of the products with respect to the relevant specific application or use thereof. Neither Schneider Electric Industries SAS nor any of its affiliates or subsidiaries shall be responsible or liable for misuse of the information contained herein.

Utilisation category

Complementary
Reset time Maximum switching voltage [Us] rated supply voltage Supply voltage limits Control circuit voltage limits Power consumption in W Width Output contacts Nominal output current Run-up delay at power-up Measurement accuracy Repeat accuracy Measurement error Sensitivity scale 1750 ms 250 V AC/DC 24...240 V AC/DC 20,4...264 V AC/DC - 15 % + 10 % Un 1,5 W DC 35 mm 2 C/O 5A 0,6 s +/- 10 % of the full scale value +/- 20 % for the HS range +/- 2 % time delay 0.5 %/C with temperature variation 0.25...5 kOhm LS (Low Sensitivity) 5...100 kOhm St (Standard Sensitivity) 50...1000 kOhm HS (High Sensitivity) 5...100 % <= 12 V 1 mA 100 m probe and delay 1

Sensitivity adjustment [Us] rated supply voltage Supply current for sensors Cable length
31.01.2013

Cable capacitance

1 nF HS (High Sensitivity) probe cable 2,2 nF St (Standard Sensitivity) probe cable 4,7 nF LS (Low Sensitivity) probe cable CE : 73/23/EEC CE : EMC 89/336/EEC III IEC 60664-1 > 500 MOhm 500 V DC IEC 60664-1 > 500 MOhm 500 V DC IEC 60255-5 250 V IEC 60664-1 50/60 Hz +/- 10 % Between supply and measurement Any position without 0,6...1 N.m IEC 60947-1 Self-extinguishing plastic 1 LED green power ON 1 LED yellow relay ON 1 LED yellow timing ON 35 mm symmetrical DIN rail EN/IEC 60715 100000 cycles 30000000 cycles <= 360 operations/hour full load

Marking Overvoltage category Insulation resistance [Ui] rated insulation voltage Supply frequency Insulation Operating position Tightening torque Housing material Status LED

Mounting support Electrical durability Mechanical durability Operating rate

Environment
Immunity to microbreaks Electromagnetic compatibility 90 ms AC 100 ms DC Emission standard for industrial environments EN/IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments EN/IEC 61000-6-3 Immunity for industrial environments NF EN/IEC 61000-6-2 EN/IEC 60255-6 C-Tick CSA GL GOST UL -40...70 C -20...50 C 95 % 55 C IEC 60068-2-30 0.35 mm 5...57,6 Hz IEC 60068-2-6/IEC 60255-21-1 1 gn 57,6...150 Hz IEC 60068-2-6/IEC 60255-21-1 15 gn 11 ms IEC 60255-21-1 IP20 terminals IEC 60529 IP30 casing IEC 60529 3 IEC 60664-1 2 kV 1 min AC 50 Hz IEC 60255-5 2 kV 1 min AC 50 Hz IEC 60664-1 4 kV IEC 61000-4-5 4 kV IEC 60664-1 4 kV IEC 60255-5 0701 Compliant

Standards Product certifications

Ambient air temperature for storage Ambient air temperature for operation Relative humidity Vibration resistance Shock resistance IP degree of protection Pollution degree Dielectric test voltage Non-dissipating shock wave

RoHS EUR conformity date RoHS EUR status

Garantie contractuala
Period 18 luni

S-ar putea să vă placă și