Daikin products are manufactured for export to numerous countries throughout the world. Prior to purchase, please confirm with your local authorised importer, distributor and/or retailer whether this product conforms to the applicable standards, and is suitable for use, in the region where the product will be used. This statement does not purport to exclude, restrict or modify the application of any local legislation. Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorised parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. If you have any enquiries, please contact your local importer, distributor and/or retailer.
PCV1131
VRV indoor units combine with residential indoor units, all in one system
All of the Daikin Group s business facilities and subsidiaries in Japan are certified under the ISO 14001 international standard for environment management.
JMI-0107
JQA-1452
Dealer
Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan
http://www.daikin.com/global_ac/
c All rights reserved Printed in Japan12/11/005 Y.K.
Specifications, designs and other content appearing in this brochure are current as of December 2011 but subject to change without notice.
Cooling Only 50 Hz
Contents
Main Features................................page 3 Option List....................................page 35 Indoor units.............................page 35
VRV.....................................page 35 Residential..........................page 37
Meet the new single outdoor unit series, connectable to both VRV and residential indoor units
First launched in Japan in 1982, the Daikin VRV system has been embraced by world markets for nearly 30 years. Now, Daikin proudly introduces the new VRVIII single outdoor unit series which enables a mixed combination of VRV indoor units and residential indoor units all in one system, opening the door to stylish and quiet indoor units.
OFFICES
SHOPS
HOMES
Main Features
BP unit
7 types 21 models
50 5.0 kW 50 60 6.0 kW 60 71 7.1 kW 71
25 25
32 31.25
40 40
50 50
63 62.5
80 80
100 100
125 5 HP 125
140 6 HP 140
200 8 HP 200
250 10 HP 250
35 3.5 kW 35
Model Name
2.5 kW 25
FDKS-C(A)VMB
(900/1,100 mm width type) (700 mm width type)
FXDQ-PBVET
Slim Ceiling Mounted Duct
(without drain pump)
FTKS-DVM
Wall Mounted
FXDQ-NBVE
(with drain pump)
FTKS-FVM
Note: BP units are necessary for residential indoor units. Refer to page 33 for BP unit details.
(900/1,100 mm width type)
FXDQ-NBVET
(without drain pump)
FXMQ-PVE
Ceiling Mounted Duct
Outdoor units
The new VRVIII single outdoor unit series offers 6 models to select from, providing the power that suits your needs.
FXMQ-MAVE
Ceiling Suspended
Wall Mounted
8, 10 HP
Note: R-410A VRV system indoor units are not compatible with the R-22 VRV system.
125 5 HP 125
BEVQ125MAVE
Model Name HP kW
3 HP 71
BEVQ71MAVE
Capacity Range
FXUQ-MAV1
Capacity Index
Note: BEV units are necessary for Connection unit series indoor units. Refer to the Engineering Data Book for details.
Main Features
High COPs
It has become essential for air conditioning manufacturers to develop systems that provide high energy savings. We at Daikin have made great efforts in this field, and the VRVIII delivers highly efficient performance, contributing to high energy savings.
Reluctance DC scroll compressor Daikins unique scroll compressor reduces heat loss, and is driven by a high efficiency motor to achieve significant energy savings.
High torque and efficiency is attained with the adoption of neodymium magnets.
8 HP
10 HP
12 HP
Reluctance DC motor
Cooling operating conditions: Indoor temp. of 27CDB, 19.0 CWB, and outdoor temp. of 35CDB.
High-performance, low-noise scroll compressor operates at a fast rate. The speed increase has been achieved through advanced stress analysis for increased strength and utilisation of the advantages (oil film control) of the high thrust mechanism.*
By introducing high pressure oil, the reactive force from the fixed scroll is added to the internal force, thereby reducing thrust losses. This results in improved efficiency and suppressed sound levels.
Set on the outdoor PCB. Time of maximum temperature is memorised. The low operating mode will initiate 8 hours*1 after the peak temperature in the daytime, and normal operation will resume 10 hours*2 after that. The operation sound level for the night mode can be selected from 55 dB(A) (Step 1), 50 dB(A) (Step 2) and 45 dB(A) (Step 3).
2 Heat exchanger
Mode 1. Automatic mode
Thanks to an optimised e-Pass heat exchanger, heat change effectiveness has been increased, thus contributing to a high COP.
Realises a compact casing by stacking the Inverter and control PCBs plus optimising the internal design to suit airflow speed. This achieves low noise and reduces the power required by the large-diameter fanned outdoor unit.
8 hrs
50
(Initial setting)
10 hrs
DC fan motor
(Initial setting)
By adoption of the Sine Wave, which smoothes the rotation of the motor, operation efficiency is improved sharply.
Night Mode
50 45 8:00
Efficiency (%)
Starting time and ending time can be input. (An external control adaptor for outdoor unit, DTA104A53/61/62, and a locally obtained timer are necessary.)
Mode 3. Combined mode
DC motor efficiency
(comparison with AC motor)
0 58 55
Step 1: 55 dB(A)
80 60 40
DC motor
Approx. increase
40%
AC motor
20 0 200 300
400 500
600
700 800
900 1000
Notes: This function is available in setting at site. The relationship of outdoor temperature (load) and time shown in the graph is just an example. The capacity reduction rate differs depending on the operation sound level step selected.
Note: Data are based on studies conducted under controlled conditions at a Daikin laboratory.
Main Features
Design flexibility
Long piping length
Long piping length offers flexibility during installation.
Actual piping length Total piping length
Max.
100
Max.
250
m Max.
Colours in the diagram below are merely for identifying pipes referenced with symbols such as a .
29
i
Indoor units
a b
First indoor branch
c f
d g h
VRV indoor units
Note: Total capacity index of connectable indoor units must be 50%130% of the capacity index of the outdoor unit. Refer to page 34 for the maximum number of connectable indoor units.
Max.
50 m k
j
Max.
15 m
Example
100 m 250 m 40 m
Level Difference
125 m
Example
78.4 Pa
Between the indoor units Maximum allowable level difference Between the outdoor unit and the indoor unit If the outdoor unit is above. If the outdoor unit is below.
15 m 50 m 40 m
j k k
Colours in the diagram below are merely for identifying pipes referenced with symbols such as a .
VRV: VRV indoor unit RA: Residential indoor unit BP: BP unit
a
First indoor branch
BP
b e i f
d g
o
Max. Max.
Easy Installation
40 m
High reliability
Backup operation
If one of the multiple compressors malfunctions, the other compressors take over for emergency operation.*1 If one compressor malfunctions...
Max.
50 m
h
RA RA
j
VRV RA
BP
15 m
k
Max.
15 m
VRV
RA
When a mixed combination of VRV and residential indoor units is connected or when only residential indoor units are connected
Refrigerant piping length Total piping length Maximum allowable piping length If indoor unit capacity index < 60. Between BP unit and indoor unit If indoor unit capacity index is 60. If indoor unit capacity index is 71. Between the first indoor branch and the farthest BP unit or between the first indoor branch and the farthest VRV indoor unit Minimum allowable piping length Between outdoor unit and the first indoor branch
Example
h, i, j, k
*1. Possible only with single outdoor unit systems that are equipped with two or more compressors. Local setting of the outdoor unit is necessary.
Level Difference
Example
Between the indoor units Between BP units Maximum allowable level difference Between the outdoor unit and the indoor unit If the outdoor unit is above. If the outdoor unit is below.
15 m 15 m 50 m 40 m 40 m
l m n n o
*1. When the piping length exceeds 20 m, the size of the main pipes (the gas side and the liquid side) must be increased. Please refer to Engineering Data Book for details.
360 airflow improves temperature distribution and offers a comfortable living environment.
The industrys first* Round Flow Ceiling Mounted Cassette type offers 360 airflow with improved temperature distribution.
4-way flow
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
Round Flow
50 41/33 42/35
All models are lighter than the conventional ones. Ex: Models FXFQ25P-50P are 4.5 kg lighter (reduced from 24 kg to 19.5 kg). Drain pump is equipped as standard accessory, and the 850 mm lift height has been improved from 750 mm to 850 mm. A modern sophisticated decoration panel has been applied, with a panel surface that has been treated with a dirt-repellant coating.
Treated surface Untreated surface
Dirt and grime Condition after exposure to the smoke of 600 3 cigarettes in 1 m enclosed space.
Comfortable airflow
1
0 60 60
0 60 60
An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours. The horizontal louvres prevent dew condensation. Their non-flocking surfaces, which repel dirt, are easy to clean. The air filter has an anti-mould and antibacterial treatment that prevents the growth of mould generated from dust or moisture that may adhere to the filter.
4-way flow 3-way flow L-shaped 2-way flow
Angles can be also set on site to prevent drafts (0-35) or soiling of the ceiling (25-60), other than standard setting (0-60).
Resists soiling
2-, 3-, and 4-way airflow patterns are available, enabling installation in the corner of a room. Drain pump is equipped as standard accessory with 750 mm lift.
Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level
FXFQ-P 25/32 40 50 63 80 100 (dB(A)) 125
Sound level 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34 (HH/H/L)
4-way flow
3-way flow
750 mm
All-round flow
For 3-way or 2-way flow installation, the sealing member for air discharge outlet (option) must be used to close each unused outlet.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing member (option) must be used to close each unused outlet.
10
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
Providing 3 different settings of standard, draft prevention and ceiling soiling prevention, the auto swing mechanism realises even distribution of airflow and room temperature.
(m) 3 28C 32C 30C 26C 24C 22C 20C 1 2 3 4 5 6 (m)
305 mm 20 mm
Panel spacer
2 1 0
(dB(A)) 125
Single-flow type allows effective air discharge from corner or from drop-ceiling. Drain pump is equipped as standard accessory with 500 mm lift.
Front discharge is possible with an air discharge unit (option), which allows the installation in the drop-ceiling or sagging wall.
Main body
Sound level 220 V 32/27 34/28 34/29 37/32 39/34 44/38 (H/L) 240 V 34/29 36/30 37/32 39/34 41/36 46/40
Designed with higher airflow suitable for high ceiling application up to 3 metres. Providing 2 different settings of standard and ceiling soiling prevention, the auto swing mechanism realises even distribution of airflow and room temperature. Drain pump is equipped as standard accessory with 600 mm lift.
500 mm
Downward discharge
Two types of optional high-efficiency filter are available (65% and 95%, colourimetric method). A long-life filter (maintenance free up to one year*) is equipped as standard accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m
3
Main body
600 mm
Major maintenance work can be performed by removing the panel. A flat-type suction grille and a detachable blade make cleaning easy.
Downward discharge is shut off and air is blown straight out (front discharge).
11
12
FXDQ40NB/FXDQ50NB/ FXDQ63NB
Middle and high static pressure allows for flexible duct design
A DC fan motor increases the external static pressure capacity range to include middle to high static pressures, increasing design flexibility.
30 Pa100 Pa for FXMQ20P-32P 30 Pa160 Pa for FXMQ40P 50 Pa200 Pa for FXMQ50P-125P 50 Pa140 Pa for FXMQ140P
Only 200 mm in height, this model can be installed in rooms with as little as 240 mm depth between the drop-ceiling and ceiling slab.
200 mm
Only
900 mm
200 mm
1,100 mm in width for the FXDQ63NB model.
All models are only 300 mm in height, an improvement over the 390 mm height of conventional models. The weight of the FXMQ40P has been reduced from 44 kg to 28 kg. Drain pump is equipped as standard accessory with 700 mm lift.
700 mm
Ceiling
700 mm
Suspension bolt*
Air filter
AIR
240 mm
Suction grille* AIR
Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level
FXMQ-P 20/25 32 40 50 63 80/100 125 (dB(A)) 140
Discharge grille*
* To be obtained locally
External static pressure selectable by remote controller switching make this indoor unit a very comfortable and flexible model.
10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models. 15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.
Sound level 33/31/29 34/32/30 39/37/35 41/39/37 42/40/38 43/41/39 44/42/40 46/45/43 (HH/H/L)
Improved ease of installation The airflow rate can be controlled using a remote controller during test operation. With the conventional model, the airflow rate was controlled from the PC board. It is automatically adjusted to the range between approximately 10% of the rated HH tap airflow for FXMQ20P125P. Improved ease of maintenance The drain pan can be detached for easy cleaning. An antibacterial treatment that uses silver ions has been applied to the drain pan, preventing the growth of slime, mould and bacteria that cause blockages and odours.
Energy-efficient The adopted DC fan motor is much more efficient than the conventional AC motor, yielding an approximate 20% decrease in energy consumption (FXMQ125P).
FXDQ-PB and FXDQ-NB models are available in two types to suit different installation conditions.
FXDQ-PB/NBVE: with a drain pump (750 mm lift) as a standard accessory FXDQ-PB/NBVET: without a drain pump
FXMQ200MA/FXMQ250MA
Control of the airflow rate has been improved from 2-step to 3-step control. Low operation sound level
FXDQ-PB/NB Sound level (HH/H/L) 20/25/32 33/31/29 40 34/32/30 50 35/33/31 (dB(A)) 63 36/34/32
470 mm
25 mm
470 mm
222 mm
The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.
External static pressure can be easily adjusted using a change-over switch inside the electrical box to meet the resistance in the duct system.
Indoor unit
Indoor unit
13
14
FXHQ32MA/FXHQ63MA FXHQ100MA
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
Sophisticated design and compact casing harmonised with your interior dcor
Compact and stylish design that does not detract from the dcor of the room. Low operation sound level
FXAQ-MA Sound level (H/L) 20 35/29 25 36/29 32 37/29 40 39/34 50 42/36 (dB(A)) 63 46/39
Drain pan and air filter can be kept clean by mildew-proof polystyrene.
(dB(A))
100 45/37
Washable grille, the front grille can be easily removed for washing. Auto-swing realises efficiency of air distribution. The louvre closes automatically when the unit stops. 5 steps of discharge angle can be set by remote controller. Maintenance is easy Non-dew Flap with no implanted bristles
Bristle-free Flap minimises contamination and makes cleaning simpler.
Discharge angle is automatically set at the same angle as the previous operation when restarting. (Initial setting: 10 for cooling) Flexible installation Drain pipe can be fitted to from either left or right sides.
Drain pump kit is available as optional accessory, which lifts the drain 1,000 mm from the bottom of the unit.
Height of drain-up
Non-dew Flap
Maintenance is easier because everything can be performed from below the unit. A long-life filter (maintenance free up to one year*) is equipped as standard accessory.
100
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
1,000 mm
15
16
FXUQ71MA/FXUQ100MA FXUQ125MA
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details. * Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
This thin indoor unit achieves optimum air distribution, and can be installed without the need for ceiling cavity.
Depending on installation site requirements or room conditions, 2-way, 3-way and 4-way discharge patterns are available.
The 3-way airflow can distribute comfortable air throughout the room.
Wall hanging
Floor installation
Only one unit is needed to distribute comfortable air throughout an L-shaped store.
* Remote controllers are an optional accessory. Refer to page 39 for remote controller details.
Connection unit is the device for connecting above indoor unit to VRV III. Connection unit BEVQ71MA/BEVQ100MA/BEVQ125MA
Refrigerant piping layout
Connection unit for indoor unit
*1 Model FXUQ-MA
Maximum piping length between the BEV unit and the indoor unit. 5m
Piping length*1
Notes: When connecting centralised-control device, it is necessary to install an interface adaptor for an indoor unit (DTA102A52). Connection unit BEVQ-MA is necessary for each indoor unit. The refrigerant piping height difference between the indoor units and the BEV unit must be within 4 m. The BEV unit must be installed within a maximum height difference between indoor units of 15 m. Branching of the refrigerant piping is not possible downstream of the BEV unit.
17
18
Option Note: Remote controller cables not included. Cables should be obtained locally.
Option
Signal receiver unit Note: Wireless remote controllers and signal receiver units are sold as a set.
Option Note: Remote controller cables not included. Cables should be obtained locally.
Option
Signal receiver unit Note: Wireless remote controllers and signal receiver units are sold as a set.
Specially designed for false ceilings for a smooth, modern interior finish
All models feature a decoration panel with the same size and simple design in consideration of harmonised interior dcor. Three convenient patterns for auto-swing operation
Standard
Horizontal Flow
286
950 mm
mm
act Comp e panel orativ dec
Draft prevention
700 mm
Decoration panel is optional
950 mm
Soiling prevention
700 mm
AUTO-SWING
Standard setting
0 60
0
5 direction
Settable to 5 different levels between 0 and 60
T-bar grid does not need to be cut. The indoor units weigh only 24 kg and require an installation space with a height of just 245 mm.
Min. 245 mm
60
Ceiling panel
T-bar
750 mm
0 35
35
600 mm 600 mm
25 60
25 60
(H/L)
Note: Angles shown above are provided as a guide. They may differ depending on the installation site.
These models have the power to provide a comfortable airflow even with a ceiling height of up to 3.8 m.
(H/L)
750 mm
20
19
FBQ60B/FBQ71B
FDKS25EA/FDKS35EA
900/1,100 mm width type
FDKS25CA/FDKS35CA/FDKS50C/FDKS60C
Option
Note: Remote controller cables not included. Cables should be obtained locally.
Standard accessory
Note: Remote controllers other than the standard accessory wireless remote controller cannot be used.
Decorative panel Air discharge opening adaptor Canvas bellows and air intake panel Flexible duct Air discharge grille Air discharge chamber
High-performance filter Inspection panel Rear intake blocking pad Air discharge opening flange Rear intake filter chamber Branch duct Low-draft filter chamber
FDKS25
FDKS35
FDKS50
FDKS60
With high-efficiency filter With canvas bellows and air intake panel (sold separately)
2 Air conditioner 4 1 3 7 3 5 5 1 1
350 mm or more
6 1
2 Air conditioner 4
540 mm or more
FDKS-EA
Air blow
Air intake
Long-life filter
Air blow
Air blow
Air intake
45 mm
Ceiling return
2 Air conditioner 6 4
Home Leave Operation prevents large rises or falls in the indoor temperature by continuing operation* while you are sleeping or out of your home. This means that an air-conditioned welcome awaits when you wake or return. It also means that the indoor temperature can quickly return to your favourite comfort setting.
* Home Leave Operation can be selected for any temperature from 18 to 32C for cooling operation and 10 to 30C for heating operation. * Home Leave Operation function must be set using the remote controller when going to sleep or leaving the house, and after waking up or returning home.
Air conditioner
9 8
1 0
460 mm or more
Air blow
Air blow
Air intake
Air blow
To cope with the challenges of L-shaped or U-shaped spaces, it is possible to install the air discharge unit away from the main unit. This extends the possibilities for coping with human gathering patterns or sun lighting. At the same time, different types of architectural space can be kept comfortable.
Suspension bolt*
Suction duct*
Air filter
AIR
250 mm
240 mm
Signal receiver wire Length = 1,900 mm
AIR
Option
(H/L)
FBQ60B
L-shaped room U-shaped room Long room
41/35 dB (A)
Notes: 1. To prevent an increase in operation noise, avoid installing the air suction grille directly below the suction chamber. 2. Grilles, piping connections, ducts, and installation parts should be obtained locally. Slim Ceiling Mounted Duct type FDKS models do not have drain-up pumps. 3. The signal receiver unit must be located near the air suction inlet, because the unit includes a sensor that detects room temperature.
21
22
kW
Galvanised steel plate m3/min cfm 13/11.5/10 13/11.5/10 15/13/11 16/13.5/11 19/16.5/13.5 21/18/15 32/26/20 33/28/22.5
Standard accessory*
Airflow rate (HH/H/L) Sound level (HH/H/L) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain Model
459/406/353 459/406/353 530/459/388 565/477/388 671/583/477 742/636/530 1,130/918/706 1,165/989/794 30/28.5/27 30/28.5/27 31/29/27 32/29.5/27 34/31/28 36/33.5/31 43/37.5/32 44/39/34
FTKS50F/FTKS60F/FTKS71F
dB(A) mm kg
246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 246X840X840 288X840X840 288X840X840 19.5 6.4 19.5 6.4 12.7 19.5 6.4 12.7 19.5 6.4 12.7 22 9.5 15.9 22 9.5 15.9 25 9.5 15.9 25 9.5 15.9
mm
12.7
VP25 (External Dia, 32/Internal Dia, 25) BYCP125K-W1 Fresh white mm kg 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 50X950X950 5.5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Standard accessory* * Remote controllers other than the standard accessory wireless remote controller cannot be used.
Panel (Option)
FTKS25D FTKS35D FTKS50F FTKS60F FTKS71F 37/25/22 dB (A) 39/26/23 dB (A) 43/34/31 dB (A) 45/36/33 dB (A) 46/37/34 dB (A)
Intelligent Eye with its infrared sensor automatically controls air conditioner operation according to human movement in a room. When there is no movement, it adjusts the temperature by 2C for energy savings.
kW
Casing Airflow rate (H/L) Sound level 230 V-240 V (H/L) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain Model Panel (Option) Colour Dimensions (HXWXD) Weight mm kg 55X700X700 2.7 55X700X700 2.7
dB(A) mm kg
These filters are not medical devices. Benefits such as the adsorption and decomposition of bacteria are only effective for substances that are collected on and in direct contact with the Titanium Apatite Photocatalytic Air-Purifying Filter. Bacteria Removal Test Testing method: dropping method Result certificate: No. 012553-1 and 012553-2 Testing organisation: Japan Spinners Inspecting Foundation
VP20 (External Dia, 26/Internal Dia, 20) BYFQ60B8W1 White (6.5Y9.5/0.5) 55X700X700 2.7 55X700X700 2.7 55X700X700 2.7
3-D Airflow combines Vertical and Horizontal Auto-Swing to circulate air to every part of a room for uniform cooling of even large spaces.
* This function is available for FTKS50/60/71F.
A uniform temperature is achieved throughout the entire room.
Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB. (*2) Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
23
24
FXDQ20PBVE FXDQ20PBVET
FXDQ25PBVE FXDQ25PBVET
1-phase, 220 -240 V/220 V, 50/60 Hz 2,500 9,900 2.9 2.8 0.086 0.067 Galvanised steel plate 8.0/7.2/6.4 282/254/226 30-10 1 33/31/29 200X700X620 23.0 6.4 12.7 VP20 (External Dia, 26/Internal Dia, 20)
FXDQ32PBVE FXDQ32PBVET
3,200 12,600 3.7 3.6 0.089 0.070
kW
Galvanised steel plate 12/9 424/318 34/29 37/32 12/9 424/318 34/29 37/32
Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain Model Panel (Option) Colour Dimensions (HXWXD) Weight
305X775X600 305X775X600 305X775X600 305X990X600 305X990X600 305X1,175X600 305X1,665X600 305X1,665X600 26.0 6.4 26.0 6.4 12.7 26.0 6.4 12.7 31.0 6.4 12.7 32.0 6.4 12.7 35.0 9.5 15.9 47.0 9.5 15.9 48.0 9.5 15.9
8.0/7.2/6.4 282/254/226
mm
12.7
VP25 (External Dia, 32/Internal Dia, 25) BYBC32G-W1 BYBC50G-W1 White (10Y9/0.5) mm kg 53X1,030X680 53X1,030X680 53X1,030X680 53X1,245X680 53X1,245X680 53X1,430X680 53X1,920X680 53X1,920X680 8.0 8.0 8.0 8.5 8.5 9.5 12.0 12.0 BYBC63G-W1
FXKQ25MAVE
FXKQ40MAVE
4,000 16,000 4.7 4.5 0.076 13/10 459/353 40/34 42/36 215X1,110X710 31.0 6.4 12.7
FXKQ63MAVE
1-phase, 220-240 V/220 V, 50/60 Hz 6,300 24,900 7.3 7.1 0.105 18/15 635/530 42/37 44/39 215X1,310X710 34.0 9.5 15.9 BYK71FJW1 70X1,240X800 8.5 70X1,440X800 9.5
MODEL
Power supply
FXDQ40NBVE FXDQ40NBVET
4,000 16,000 4.7 4.5 0.160 0.147
FXDQ50NBVE FXDQ50NBVET
1-phase, 220 -240 V/220 V, 50/60 Hz 5,000 19,800 5.8 5.6 0.165 0.152 Galvanised steel plate
FXDQ63NBVE FXDQ63NBVET
6,300 24,900 7.3 7.1 0.181 0.168
kW
Cooling capacity
Galvanised steel plate Power consumption (FXDQ-NBVE) Power consumption (FXDQ-NBVET) Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) 2 3 Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain
kW kW
Dimensions (HXWXD) Machine weight Liquid (Flare) Piping Gas (Flare) connections Drain Model Panel (Option) Colour Dimensions (HXWXD) Weight
10.5/9.5/8.5 371/335/300
16.5/14.5/13.0 583/512/459
35/33/31 200X900X620 28.0 6.4 12.7 VP20 (External Dia, 26/Internal Dia, 20)
mm kg
70X1,240X800 8.5
70X1,240X800 8.5
mm
12.7
Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB. (*2) Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. (FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB. (*2) Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. 1 : External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is 10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.) 2: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be obtained by adding 5 dB(A). 3: Values are based on the following conditions: external static pressure of 10 Pa. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
25
26
MODEL
Power supply kcal/h (*1) Cooling capacity Btu/h (*1) kW Power consumption Casing (*1) (*2) kW
FXMQ200MAVE
19,800 78,500 23.0 22.4 1.294 Galvanised steel plate m3/min cfm 58/50 2,047/1,765
132-221
1
FXMQ250MAVE
24,800 98,300 28.8 28.0 1.465
(*1) (*2)
kW
9.5/8/7 335/282/247
30-100
1
16/13/11 565/459/388
30-160
1
18/16.5/15 635/582/530
50-200
1
Airflow rate (H/L) External static pressure Sound level (H/L) 220 V 240 V
72/62 2,542/2,189
191-270
1
Pa dB(A) mm kg
Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Brazing) Drain
mm
19.1
MODEL
Power supply kcal/h(*1) Cooling capacity Btu/h(*1) kW Power consumption Casing Airflow rate (HH/H/L) External static pressure Sound level (HH/H/L) Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain mm m3/min cfm Pa dB(A) mm kg (*1) (*2) kW
FXHQ32MAVE
FXHQ63MAVE
1-phase, 220-240 V/220 V, 50/60 Hz 6,300 24,900 7.3 7.1 0.115 White (10Y9/0.5) 17.5 /14 618/494 39/34 195X1,160X680 28.0 9.5 15.9 VP20 (External Dia, 26/Internal Dia, 20)
FXHQ100MAVE
10,000 39,600 11.6 11.2 0.135
25/22.5/20 883/794/706
50-200
1
32/27/23 1,130/953/812
50-200
1
39/33/28
1
46/39/32
1
1,377/1,165/988 1,624/1,377/1,130
50-200 50-140
Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB. (*2) Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. 1: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard static pressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB. (*2) Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. 1: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure". Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: (FXMQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre. (FXHQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
27
28
* A type of BEV unit is necessary for each Connection unit series indoor unit. Refer to the Engineering Data for details. * Group control between Connection Unit series equipment within one system is possible. However, group control with the other VRV indoor units is not possible.
(*1) (*2)
kW
White (3.0Y8.5/0.5) 7.5/4.5 265/159 35/29 290X795X230 11.0 6.4 12.7 8/5 282/177 36/29 290X795X230 11.0 6.4 12.7 9/5.5 318/194 37/29 12/9 424/318 39/34 15/12 530/424 42/36 19/14 671/494 46/39
FXUQ71MAV1 BEVQ71MAVE
7,100 28,300 8.3 8.0 0.189
FXUQ100MAV1 BEVQ100MAVE
1-phase, 220-240 V, 50 Hz 10,000 39,600 11.6 11.2 0.298 White (10Y9/0.5)
FXUQ125MAV1 BEVQ125MAVE
12,500 49,500 14.5 14.0 0.298
290X795X230 290X1,050X230 290X1,050X230 290X1,050X230 11.0 6.4 12.7 14.0 6.4 12.7 14.0 6.4 12.7 14.0 9.5 15.9
(*2)
kW
29/21 1,024/741 43/38 230X895X895 31 9.5 (Flare) 15.9 (Flare) VP 20 (External Dia. 26/Internal Dia. 20)
FXLQ20MAVE FXLQ25MAVE FXLQ32MAVE FXLQ40MAVE FXLQ50MAVE FXLQ63MAVE FXNQ20MAVE FXNQ25MAVE FXNQ32MAVE FXNQ40MAVE FXNQ50MAVE FXNQ63MAVE
1-phase, 220-240 V/220 V, 50/60 Hz 3,200 12,600 3.7 3.6 0.090 4,000 16,000 4.7 4.5 0.090 5,000 19,800 5.8 5.6 0.110 6,300 24,900 7.3 7.1 0.110
FXLQ
Cooling capacity
Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB. (*2) Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: Anechoic chamber conversion value, measured at a point 1.5 m below the unit centre. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
kW
FXLQ: Ivory white (5Y7.5/1)/FXNQ: Galvanised steel plate m3/min cfm 7/6 247/212 35/32 37/34 mm 7/6 247/212 35/32 37/34 8/6 282/212 35/32 37/34 11/8.5 388/300 38/33 40/35 14/11 494/388 39/34 41/36 16/12 565/424 40/35 42/37
FXNQ
Airflow rate (H/L) 220 V 240 V Dimensions (HXWXD) Machine weight FXLQ FXNQ FXLQ FXNQ Liquid (Flare) Piping connections Gas (Flare) Drain
dB(A)
600X1,000X222 600X1,000X222 600X1,140X222 600X1,140X222 600X1,420X222 600X1,420X222 610X930X220 610X930X220 610X1,070X220 610X1,070X220 610X1,350X220 610X1,350X220 25.0 19.0 6.4 12.7 30.0 23.0 6.4 12.7 21O.D. 30.0 23.0 6.4 12.7 36.0 27.0 6.4 12.7 36.0 27.0 9.5 15.9
kg
mm
12.7
Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB. (*2) Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Equivalent piping length: 7.5 m Level difference: 0 m Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index. (See Engineering Data Book for details.) Sound level: (FXAQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward. (FXLQ-MA, FXNQ-MA) Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
29
30
FBQ60BV1
1-phase, 220 -240 V, 50 Hz 17.0 (600) 41/35 2 steps Microcomputer control mm kg 6.4 mm 12.7 I.D 25XO.D 32 Both liquid and gas pipes BYBS71DJW1 White mm kg 55X1,100X500 4.5 300X1,000X800 41
FBQ71BV1
19.0 (670)
FCQ35BVE
m3/min (cfm) dB (A) 14.0 (494) 33/29
FCQ50BVE
15.0 (530)
FCQ60BVE
FCQ71BVE
Fan speed Temperature control Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain Heat insulation
1-phase, 220-240 V/220 V, 50/60 Hz 19.0 (671) 35/30 2 steps Microcomputer control mm kg 6.4 mm 9.5 12.7 I.D 25XO.D 32 Both liquid and gas pipes BYC125K-W1 White mm kg 40X950X950 5 230X840X840 24 9.5 15.9
9.5 15.9
MODEL
Power supply Airflow rates (H) Sound levels (H/L)* Fan speed Temperature control Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain Heat insulation Model Panel (Option) Colour Dimensions (HXWXD) Weight mm kg mm mm kg m3/min (cfm) dB (A)
FFQ25BV1B
9.0 (318) 29.5/24.5
FFQ35BV1B
10.0 (353) 32/25 2 steps
FFQ50BV1B
12.0 (424) 36/27
FFQ60BV1B
15.0 (530) 41/32
Temperature control Dimensions (HXWXD) Machine weight Liquid (Flare) Piping connections Gas (Flare) Drain Heat insulation External static pressure
1-phase, 220-240 V, 50 Hz
Microcomputer control 286X575X575 17.5 6.4 9.5 VP20 (External Dia. 26/Internal Dia. 20) Both liquid and gas pipes BYFQ60B8W1 White 55X700X700 2.7 12.7
Note: * The operation sound level values represent those for rear-suction operation and an external static pressure of 30 Pa for FDKS-EA and 40 Pa for FDKS-C. Sound level values for bottom-suction operation can be obtained by adding 6 dB (A) for FDKS-EA and 5 dB (A) for FDKS-C.
FTKS60FVM
FTKS71FVM
Note: * Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
31
32
MODEL
Power supply kcal/h(*1)
RSXQ8PY1
19,400 76,800 22.5 22.4 5.24 20-100
RSXQ10PY1
24,300 96,200 28.2 28.0 7.90 14-100
RSXQ12PY1
29,000 115,000 33.7 33.5 8.93 14-100
RSXQ14PY1
34,600 137,000 40.2 40.0 12.4 10-100
RSXQ16PY1
39,000 155,000 45.3 45.0 14.2 10-100
RSXQ18PY1
42,400 168,000 49.3 49.0 16.4 9-100
MODEL
Power supply Number of ports Power consumption Running current Dimensions (HXWXD) Machine weight W A mm kg
BPMKS967B3B
1-phase, 220-240 V/220 V, 50/60 Hz 3 (connectable to 1-3 indoor units) 10 0.05 180X294 (+356*)X350 8
BPMKS967B2B
2 (connectable to 1-2 indoor units)
Power consumption (*2) Capacity control Casing colour Compressor Type Motor output
kW %
Ivory white (5Y7.5/1) Hermetically sealed scroll type kW m3/min mm kg dB(A) CDB kg mm 4.7 9.5 (Brazing) 19.1 (Brazing) 4.9 9.5 (Brazing) 22.2 (Brazing) 6.0 12.7 (Brazing) 28.6 (Brazing) Type Charge Liquid Gas 188 57 3.6X1 180 1,680X930X765 232 58 268 60 5 to 43 R-410A 6.3 12.7 (Brazing) 28.6 (Brazing) 6.5 12.7 (Brazing) 28.6 (Brazing) 6.7 15.9 (Brazing) 28.6 (Brazing) 312 60 (1.4+4.5)X1 185 (1.8+4.5)X1 233 (1.4+4.5+4.5)X1 233 1,680X1,240X765 312 60 324 63 (2.7+4.5+4.5)X1 233 (2.8+4.5+4.5)X1 239
7.5
Airflow rate Dimensions (HXWXD) Machine weight Sound level Operation range Refrigerant
Number of wiring connections Piping connections (Brazing) Liquid Main Branch Gas Main Branch Heat insulation Connectable indoor units Min. rated capacity of connectable indoor units Max. rated capacity of connectable indoor units kW kW mm mm mm mm
3 for power supply (including earth wiring), 2 for interunit wiring (outdoor unit-BP, BP-BP), 4 for interunit wiring (BP-indoor unit) 9.5X1 6.4X3 19.1X1 15.9X3 Both liquid and gas pipes 2.5 kW class to 7.1 kW class residential indoor units 2.5 20.8 14.2 15.9X2 6.4X2
Piping connections
Note: Specifications are based on the following conditions; Cooling: (*1) Indoor temp. of 27CDB, 19.5CWB, and outdoor temp. of 35CDB. (*2) Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB. Equivalent piping length: 7.5 m Level difference: 0 m
Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m. During actual operation, these values are normally somewhat higher as a result of ambient conditions.
HP 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP
13 16 19 22 26 29
* Total capacity index of connectable indoor units must be 50%130% of the capacity index of the outdoor unit.
Combination ratio =
Total capacity index of the indoor units Capacity index of the outdoor unit
33
34
Item
Type
5 6 7 8
Decoration panel Sealing member of air discharge outlet Panel spacer High efficiency filter unit 65% High efficiency filter unit 90% Replacement high efficiency filter 65% Replacement high efficiency filter 90% Filter related Filter chamber Long life replacement filter Non-woven type Ultra long-life filter Replacement ultra long-life filter Without T shape and fan Chamber type With T shape without fan Fresh air intake kit Direct installation type Branch duct chamber Chamber connection kit Insulation kit for high humidity
FXMQ40P
FXMQ200MA FXMQ250MA
KDU30L250VE KAFJ372L280 KAFJ373L280 KDJ3705L280 KAFJ371L280
Type
FXHQ32MA
KDU50N60VE KAF501DA56 KHFP5MA63
FXHQ63MA
KDU50N125VE KAF501DA80 KHFP5MA160
FXHQ100MA
KAF501DA112
Item
Type
FXZQ20M
FXZQ25M
FXZQ32M
BYFQ60B8W1 KDBH44BA60 KDBQ44BA60A KAFQ441BA60 KDDQ44XA60
FXZQ40M
FXZQ50M
2 3
Decoration panel Sealing member of air discharge outlet Panel spacer Replacement long-life filter Fresh air intake kit Direct installation type
Item
Drain pump kit
Type FXAQ20MA
FXAQ25MA
FXAQ32MA
FXAQ40MA
FXAQ50MA
FXAQ63MA
K-KDU572EVE
FXCQ25M FXCQ32M
FXCQ40M
FXCQ50M
FXCQ63M
BYBC63G-W1 KAFJ532G80 KAFJ533G80 KDDFJ53G80 KAFJ531G80
FXCQ80M FXCQ125M
BYBC125G-W1 KAFJ532G160 KAFJ533G160 KDDFJ53G160 KAFJ531G160
2
Note:
Filter related
BYBC32G-W1 High efficiency filter 65% 1 KAFJ532G36 High efficiency filter 90% 1 KAFJ533G36 Filter chamber bottom suction KDDFJ53G36 Long life replacement filter KAFJ531G36
Item
Panel related Air inlet and air discharge outlet related
Type
Decoration panel Panel spacer Long life replacement filter Air discharge grille Air discharge blind panel Flexible duct (with shutter)
FXKQ25MA
FXKQ32MA
BYK45FJW1 KPBJ52F56W KAFJ521F56 K-HV7AW KDBJ52F56W KFDJ52FA56
FXKQ40MA
FXKQ63MA
BYK71FJW1 KPBJ52F80W KAFJ521F80 K-HV9AW KDBJ52F80W KFDJ52FA80
FXUQ71MA
KDBH49FA80 KDBT49FA80 KDGJ49FA80
FXUQ100MA
KAF495FA140
FXUQ125MA
(*1)
Note: (*1): This option is necessary for setting up 2-way (opposing directional) airflow when the air conditioner is installed.
Type Item
Insulation kit for high humidity
FXDQ20PB
FXDQ25PB
KDT25N32
FXDQ32PB
Type Item
Insulation kit for high humidity
FXDQ40NB
KDT25N50
FXDQ50NB
FXDQ63NB
KDT25N63
35
36
Item
Decoration panel Panel spacer
Type
FCQ35BVE
Item
Titanium apatite photocatalytic air-purifying filter
Type FTKS25DVM
FTKS35DVM
FTKS50FVM
FTKS60FVM
KAF952B42
FTKS71FVM
Chamber Without T-shaped pipe and fan*1 type With T-shaped pipe, without fan*2 Direct installation type*3 (Colourimetric method 65%) High-efficiency filter (Colourimetric method 90%) (Colourimetric method 65%) Replacement high-efficiency filter (Colourimetric method 90%) High-efficiency filter chamber Replacement long-life filter Branch duct chamber Fresh air intake kit
BYC125K-W1 KDBP55H160WA KDDP55D160 KDDP55D160K KDDJ55X160 KAFP556D80 KAFP557D80 KAFP552H80 KAFP553H80 KDDF55DA160 KAF551KA160 KDJ55K80
KAF970A46
Notes: *1. With a suction chamber. Fresh air intake is from 2 holes on the sides of the connection chamber. (This method should be selected if a wireless remote controller is used.) *2. Without a suction chamber. Fresh air intake is from 2 holes on the connection chamber via a T-shaped pipe connection. (A wireless remote controller cannot be used in this case.) *3. Without a suction chamber. Fresh air intake is directly from a hole on the main unit.
Item
Decoration panel Replacement long-life filter Fresh air intake kit Direct installation type Sealing member for air discharge outlet Panel spacer
Type
FFQ25BV1B
FFQ35BV1B
FFQ50BV1B
Item
REFNET joint
Type
BPMKS967B2B
KHRP26A22T
BPMKS967B3B
Note: A single BP unit does not require a REFNET joint. 2 BP units require only 1 REFNET joint, and 3 BP units require only 2 REFNET joints.
Item
Decoration panel Service access panel
Type
FBQ60BV1
FBQ71BV1
(Colourimetric method 65%) (Colourimetric method 90%) Replacement long-life filter Resin net Filter chamber for bottom suction Filter chamber for rear suction Canvas duct 150 Discharge grille 200 150 Discharge chamber 200 Branch duct 150 200 150 Flexible duct 200 Blind board Adaptor for discharge Flange for suction High-efficiency filter
BYBS71DJW1 KTBJ25L80W KAF252LA80 KAF253LA80 KAFJ251K80 KAJ25LA80D KAJ25LA80B KSAJ25K80 K-DG5DW K-DG9DW K-DGC5D K-DGC9D K-DDV20A K-FDS151C(1m)/K-FDS152C(2m)/K-FDS153C(3m)/K-FDS154C(4m)/K-FDS155C(5m)/K-FDS156C(6m) K-FDS201C(1m)/K-FDS202C(2m)/K-FDS203C(3m)/K-FDS204C(4m)/K-FDS205C(5m)/K-FDS206C(6m) KBBJ25KA80 KDAJ25K71 KDJ2507K80
RSXQ8PY1
RSXQ10PY1
RSXQ12PY1
RSXQ14PY1
RSXQ16PY1
RSXQ18PY1
KHRP26M22H (Max. 4 branch) KHRP26M33H (Max. 8 branch) KHRP26A22T KHRP26A33T KHFP22B8P KHFP22B10P KHFP22B12P
KHRP26M22H (Max. 4 branch) KHRP26M33H (Max. 8 branch) KHRP26M72H (Max. 8 branch) KHRP26A22T KHRP26A33T KHRP26A72T KHFP22B16P KWC26C450 BHGP26A1 KHFP22B18P
Auxiliary pipe set*1 Central drain pan kit Digital pressure gauge kit
Item
Suction grille Insulation kit for high humidity
KWC26C280
Note: *1. Auxiliary pipe sets are not attached to the outdoor units. If neccesary, use the optional accessories.
37
38
BRC1E61
Wireless remote controller *Wireless remote controller and signal receiver unit are sold as a set. *Refer to page 43 for the name of each model.
BRC1C62
BRC1D61 Notes: 1. Standard remote controllers (BRC1C62) not required. 2. If the BRC1D61 is connected to the centralised remote controllers (DCS303A51, DCS302CA61, DCS301BA61, DST301BA61), the schedule function is not available. Concealed type
(For hotel use) (BRC3A61)
Exposed type
(BRC2C51)
The concealed type remote controller smartly fits into a night table or console panel in a hotel room.
The wired remote controller supports a indoor units Wide variation of remote controllers for wide range of control functions Wide variation of remote controllers for VRV indoor units indoor units
Control by two remote controller
1
Group control
Outdoor unit
One remote controller can control the operation of max.16 indoor units at the same time.
The indoor unit can be connected by the two remote controller, for example one in the room and the other one in the control room, which can control the operation of indoor unit freely. (The last command has a priority.) Of course, the group control by two remote controller is also possible.
FXZQ
FXCQ
FXKQ
FXDQ
FXMQ
FXHQ
FXAQ
FXL(N)Q
FXUQ
(BRC1C62)
Remote control
The wiring of remote controller can be extended to max. 500 m and it is possible to install the remote controllers for the different indoor units in one place.
Remote controller
The operation of the Heat Reclaim Ventilator can be controlled by the remote controller of the indoor unit. Of course, the remote controller can display the time to clean the filter.
4 1 2 3 4
The system can be expanded to add several controllers, such as BMS, Forced OFF input and etc.
39
40
DCS601C51
Dio Unit DEC102A51 (Option) Di Unit DEC101A51 (Option)
Communication functions in the user-friendly icon-based multilingual controller simplify centralised control of the VRV system.
Function 5
Input (Lights) Set temperature change command Input (Key signal General purpose ADP) OFF command
Function 1
System
Remote monitoring and control
Colour LCD touch panel icon display Small manageable size Simplified engineering Multi language (English, French, Italian, German, Spanish, Dutch,
Portuguese, Chinese and Korean) Yearly schedule PPD (Power Proportional Distribution function) (Option) Auto heat/cool change-over Temperature limitation Enhanced history function Air Conditioning Network Service System (Optional Maintenance Service) Simple Interlock Function
Support for centralised control from elsewhere using a PC with a Web browser (Option) Sending of e-mail alerts to a specified address when malfunctions occur (Option) Built-in modem for connecting to Air Conditioning Network Service System (Option) Doubling of number of connectable indoor units by adding a D -NET Plus Adaptor (Option) Management of facilities/equipment other than A/C units (By adding Dio unit or Di unit)
Simple Interlock Function
Function 6
Function 2
Malfunction report by E-mail
Mobile Phone PC
Pi Port Connection to power consumption metre when using power proportional distribution function. (Option) RS-232C Heat Reclaim Ventilator
Function 3
Via internet
D -NET
Function 4
Residential central remote controller* (Option) Max. 16 groups of indoor units can be easily controlled with the large LCD panel.
Max. 16 groups (128 indoor units) controllable Backlight and large LCD panel for easy readability ON/OFF, temperature settings and scheduling can
All indoor units can be turned on or off at once with ALL button. Each group has a dedicated button for convenience. Outside temperature display
Unified on/off controller (DCS301BA61) Connection of up to 8 units possible Address setting of central control can be performed from the remote controller.
DCS303A51
* For residential use only. Cannot be used with other centralised control equipment.
Central remote controller (Option) Max. 64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller.
Max. 64 groups (128 indoor units) controllable Max. 128 groups (128 indoor units) are controllable by using 2 central remote controllers, which can control from 2 different places. Zone control Malfunction code display Max. wiring length 1,000 m (Total: 2,000 m) Connectable with Unified ON/OFF controller, schedule timer and BMS system Airflow volume and direction can be controlled individually for indoor units in each group operation. Ventilation volume and mode can be controlled for the Heat Reclaim Ventilator. Up to 4 ON/OFF pairs can be set per day by connecting a schedule timer.
Connectable number of centralised control equipment Central remote controller Unified on / off controller Schedule timer 2 units 8 units 1 unit Group control of up to 16 units is possible (group control via automatic address setting)
DCS302CA61
Max. wiring length 1,000 m (Total: 2,000 m) Compact size casing (Thickness: 16 mm) Connectable with Central Remote controller, Schedule timer and BMS system
DCS301BA61
Schedule timer (Option) Max. 128 indoor units can be operated as programmed schedule.
Max. 128 indoor units controllable When used in combination with a central remote controller, a maximum of 8 weekly schedule patterns can be set, while the central controller can be used to select desired zones. Up to 2 ON/OFF pairs can be set per day. Max. 48 hours back up power supply Max. wiring length 1,000 m (Total: 2,000 m) Compact size casing (Thickness: 16 mm) Connectable with Central Remote controller, Unified ON/OFF controller and BMS system
6 cores Schedule timer (DST301BA61) 1 unit connection possible ; 8 weekly schedule control patterns possible
7 cores max.
Interlink Building Management System (host computer monitor panel) also possible
DST301BA61
41
42
System Configuration
No. Item
Residential central remote controller Central remote controller Electrical box with earth terminal (3 blocks) Unified ON/OFF controller Electrical box with earth terminal (2 blocks) Noise filter (for electromagnetic interface use only) Schedule timer 5-room centralised controller for residential indoor units Interface adaptor for residential indoor units Interface adaptor for SkyAir-series Central control adaptor kit
For FTKS-D/F, FDKS-EA/C(A) For FTKS-D/F, FDKS-EA/C(A) For FCQ-B, FFQ-B, FBQ-B For SkyAir, FD(Y)M-FA, FDY-KA FDYB-KA, FVY(P)J-A, FXUQ-MA For UAT(Y)-K(A),FD-K
Model No.
Note 3
Function
Up to 16 groups of indoor units (128 units) can be easily controlled using the large LCD panel. ON/OFF, temperature settings and scheduling can be controlled individually for indoor units. Up to 64 groups of indoor units(128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished individually or simultaneously. Connectable up to 2 controllers in one system.
Type Item
Wireless type Remote controller Wired type
FXFQ-P
FXZQ-M
FXCQ-M FXKQ-MA FXDQ-PB FXMQ-P FXMQ-MA FXHQ-MA FXAQ-MA FXLQ-MA FXUQ-MA FXDQ-NB FXNQ-MA
BRC4C63 BRC4C66 BRC4C66 BRC1C62 BRC1E61 BRC1D61 BRC2C51 BRC3A61 KRP1B61 KRP2A61 KRP1B61 KRP2A61 KRP1B56 KRP2A53 KRP4A54 KRP1C64 KRP2A61 KRP1B61 KRP2A61 KRP1BA54 KRP2A62 KRP4AA52 KRP2A61 BRC2C51 BRC3A61 KRP1B61 KRP2A61 KRP2A62 KRP4AA53 BRC4C64 BRC7EA66 BRC7EA619 BRC4C64 BRC7CA529W
DCS303A51
Note 2
DCS302CA61 KJB311AA
Note 2
Navigation remote controller (Wired remote controller) Wired remote controller with weekly schedule timer Simplified remote controller (Exposed type) Remote controller for hotel use (Concealed type) Adaptor for wiring Wiring adaptor for electrical appendices (1) Wiring adaptor for electrical appendices (2) Remote sensor (for indoor temperature) Installation box for adaptor PCB External control adaptor for outdoor unit Adaptor for multi tenant KRP1C63 KRP2A62 KRP4AA53 KRCS01-4B
Notes 2, 3
Up to 16 groups of indoor units(128 units) can be turned, ON/OFF individually or simultaneously, and operation and malfunction can be displayed. Can be used in combination with up to 8 controllers.
DST301BA61
Note 4
Programmed time weekly schedule can be controlled by unified control for up to 64 groups of indoor units (128 units). Can turn units ON/OFF twice per day. Up to 5 indoor units can be controlled. This is a low cost system which can only control ON/OFF.
Notes 4, 6
KRP1BA101 DTA104A62
Notes 2, 3
KRP1B96
Notes 4, 6
Notes 2, 3
Note 3
Notes 2, 3
KRP1BA97
DTA104A61 DTA104A61
Adaptors required to connect products other than those of the VRV System to the high-speed DIII-NET communication system adopted for the VRV System.
* To use any of the above optional controllers, an appropriate adaptor must be installed on the product unit to be controlled.
7 8 9
Notes: 1. Installation box is necessary for each adaptor marked . 2. Up to 2 adaptors can be fixed for each installation box. 3. Only one installation box can be installed for each indoor unit. 4. Up to 2 installation boxes can be installed for each indoor unit. 5. Installation box is necessary for second adaptor. 6. Installation box is necessary for each adaptor.
Up to 1024 units can be centrally controlled in 64 different groups. DTA109A51 Wiring restrictions (max. length: 1,000 m, total wiring length: 2,000 m, max. number of branches: 16) apply to each adaptor. Fixing plate for DTA109A51
10
10-1
KRP4A92
Type Item
Remote controller Adaptor for wiring Wiring adaptor for electrical appendices Installation box for adaptor PCB Remote sensor (for indoor temperature) Wiring adaptor for time clock/remote controller Note 5 (Normal open pulse contact/normal open contact) Remote controller loss prevention chain Wired typeNote 1 Wireless type
FCQ-B
FFQ-B
BRC1C61 BRC7E531W
Note 4
FBQ-B
FDKS-EA FDKS-C(A)
Note 2
FTKS-D FTKS-F
Notes: 1. Installation box for adaptor must be obtained locally. 2. For FXUQ-MAV1, an interface adaptor (DTA102A52) for the SkyAir series is necessary. For residential indoor units, an interface adaptor (KRP928BB2S or DTA112BA51) is required for each indoor unit. 3. For residential use only. Cannot be used with other centralised control equipment. 4. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.
BRC7C613W
Note 3
KRP1BA57
Note 3
KRP1BA57
Note 4
KRP1BA54 KRP4AA51
KRP4AA53 KRP1B98
Item
Hardware intelligent Touch Controller Hardware DIII-NET plus adaptor PPD Web
Model No.
DCS601C51 DCS601A52 DCS002C51 DCS004A51 KJB411A DAM602B52 DAM602B51 DAM602B51x2 DAM602B51x3 DAM602B51x4 DAM002A51 DAM004A51 DAM003A51 DAM101A51 DEC101A51 DEC102A51 Power Proportional Distribution function
Function
Air-Conditioning management system that can be controlled by a compact all-in-one unit. Additional 64 groups (10 outdoor units) is possible. PPD: Power Proportional Distribution function Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC. Wall embedded switch box.
Notes: 1. Wiring for wired remote controller should be obtained locally. 2. A wireless remote controller is a standard accessory for FDKS and FTKS models. 3. Installation box for adaptor PCB (KRP1B98) is necessary. 4. Installation box for adaptor PCB (KRP1BA101) is necessary. 5. Time clock and other devices should be obtained locally.
intelligent Manager III 2-1 2-2 2-3 2-4 2-5 2-6 3 3-1 3-2 4 5 6 7 8
Monitors and controls the air conditioning system using the Internet and a Web browser application on a PC. ECONO (Energy saving functions.) External temperature sensor for intelligent Manager III. 8 pairs based on a pair of On/Off input and abnormality input. 4 pairs based on a pair of On/Off input and abnormality input. Interface unit to allow communications between VRV and BMS. Operation and monitoring of airconditioning systems through BACnet communication.
Communication line
Expansion kit, installed on DMS502B51, to provide 2 more DIII-NET communication ports. Not usable independently. Expansion kit, installed on DMS502B51, to provide 16 more wattmeter pulse input points. Not usable independently. Interface unit to allow communications between VRV and BMS. Operation and monitoring of airconditioning systems through LONWORKS communication.
Contact/analogue signal
Parallel interface Basic unit Temperature measurement units Temperature setting units Unification adaptor for computerised control
Enables ON/OFF command, operation and display of malfunction; can be used in combination with up to 4 units. Enables temperature measurement output for 4 groups; 0-5VDC. Enables temperature setting input for 16 groups; 0-5VDC. Interface between the central monitoring board and central control units.
Notes: *1. BACnet is a registered trademark of American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). *2. LONWORKS is a trademark of Echelon Corporation registered in the United States and other countries. *3. Installation box for adaptor must be obtained locally.