TeSys range provide you more simplicity, compactness, openness and exibility ... so many evolutions and new items to aid your productivity.
7
Increase your productivity, adopt our solutions which help to simplify setting-up.
8
Motor starters p Ready-to-use component combinations, designed to work together in perfect harmony. p Safe operation and level of coordination guaranteed by a major manufacturer. Power circuit control p A wide range of components. p Solutions for a variety of power control applications: lighting, capacitor switching, heating, changeover contactor pairs, resistive loads, upstream protection.
10
Contents
Motor control components
New
TeSys contactors .............................................................. 5/2 to 5/11 p Contactors, TeSys K, D, F, B p Variable composition contactors, TeSys CV TeSys protection components ..................................... 5/12 to 5/33 p Thermal-magnetic circuit-breakers p Magnetic circuit-breakers p Fuse carriers, switch-disconnector-fuses p Thermal overload relays p Electronic thermal overload relays p Electronic overload relays p Starter-controller, TeSys T p Multifunction protection relays p Switch disconnectors Mini Vario and Vario TeSys starters ............................................................... 5/34 to 5/41 p Combination motor starters p Starter-controller, TeSys U p Controller, TeSys U p Enclosed motor starters TeSys installation system ............................................. 5/42 to 5/43 p For motor starter components with spring terminals, TeSys Quickt technology
The new TeSys GV3 circuit-breakers, LC1D 40/50/65 contactors, LRD3 thermal relays are equiped with the new terminal block:
EverLink
Long lasting connection quality. Schneider Electric patented technology.
8
TeSys U Communication modules
10
With open communication across CANopen, Probus DP, Modbus, AS-interface, Advantys STB, DeviceNet and Ethernet networks, TeSys U has openness in mind.
5/1
TeSys K
Contactors
0.065.5 kW
1
Connections
screw clamp terminals
Rated operational current Rated operational power in category AC3 Contactor type (1)*
Ie max AC-3 (Ue 440V) Ie AC-1 ( 40 C) 220/240 V 380/400 V415/440 V 660/690 V500 V a c a c
Add the gure 3 before the voltage code. Example LC1-K0610 becomes LC1-K06103 b Faston connectors, 1 x 6.35 or 2 x 2.8
Add the gure 7 before the voltage code. Example LC1-K0610 becomes LC1-K06107 b solder pins for printed circuit boards Add the gure 5 before the voltage code. Example LC1-K0610 becomes LC1-K06105 (1) Basic reference, to be completed by adding 01 for N/C auxiliary contact, or 10 for N/O auxiliary contact. * Basic reference to be completed by adding the coil voltage
6
Standard control circuit voltages
a supply Contactors LC1-K (0.81.15 Uc) (0.851.1UC)
12 J7 256 W7
20 Z7 277 UE7
24 B7 380/400 Q7
36 C7
42 D7 400 V7
48 E7 400/415 N7
110 F7
120 G7 480 T7
220/230 M7 660/690 Y7
230 P7
230/240 U7
Contactors LP1-K (0.81.15 Uc) Volts Code 12 JD 20 ZD 24 BD 36 CD 48 ED 60 ND 72 SD 100 KD 110 FD 125 GD 155 PD 174 QD 200 LD 220 MD 230 MPD 240 MUD 250 UD
Coil with integral suppression device available, add 3 to the code required. Example JD3 Low consumption Contactors LP4-K (0.71.30 Uc), coil suppression as standard
Volts Code
12 JW3
20 ZW3
24 BW3
48 EW3
72 SW3
110 FW3
120 GW3
10
5/2
1
Auxiliary contact blocks
instantaneous, screw clamp connections for LC1, LP1-K, LP4 for LC1, LP1-K
Composition Reference
electronic time delay
2N/O LA1-KN20
2N/C
4N/O LA1-KN40
4N/C
LA1-KN02
LA1-KN04
Relay outputs, with common point changeover contact, a or c 2448, 2 A maximum Control voltage 0.851.1Uc Maximum switching capacity 250 VA or 150 W Operating temperature -10+ 60C Reset time: 1.5 s for 0.5 s after the time delay period Type Timing range Composition Voltage Reference On-delay 130 s 1 a or c 2448 V LA2-KT2E a 110240 LA2-KT2U
6
Suppressor modules
For LC1, LP1-K Type Voltage Reference Varistor (a and c) 1224 V LA4-KE1B 3248 V LA4-KE1E 50129 V LA4-KE1FC 130250 V LA4-KE1UG Diode (c) + zener 1224 V LA4-KC1B 3248 V LA4-KC1E RC (a) 220250 V LA4-KA1U
10
5/3
TeSys D
Contactors
0.0675 kW
1
Connections
screw clamp terminals or connectors
Rated operational voltage Rated operational current Rated operational power in category AC3 Ie max AC-3 (Ue 440V) Ie AC-1 ( 60 C) 220/240 V 380/400 V 415/440 V 500 V 660/690 V 1000 V Contactor type * Reversing contactor type * with mechanical interlock
spring terminals
(1)
690 V 9A 25 A 2.2 kW 4 kW 4 kW 5.5 kW 5.5 kW LC1-D09 LC2-D09 3 kW 5.5 kW 5.5 kW 7.5 kW 7.5 kW LC1-D12 LC2-D12 12 A 18 A 32 A 4 kW 7.5 kW 9 kW 10 kW 10 kW LC1-D18 LC2-D18 25 A 40 A 5.5 kW 11 kW 11 kW 15 kW 15 kW LC1-D25 LC2-D25 32 A 50 A 7.5 kW 15 kW 15 kW 18.5 kW 18.5 kW LC1-D32 LC2-D32 9 kW 18.5 kW 18.5 kW 18.5 kW 18.5 kW LC1-D38 LC2-D38 38 A
Add the gure 3 before the voltage code. Example LC1-D09P7 becomes LC1-093P7
lug-clamps
(2)
Add the gure 6 before the voltage code. Example LC1-D09P7 becomes LC1-096P7
Faston connectors
(3)
Add the gure 9 before the voltage code. Example LC1-D09P7 becomes LC1-099P7 * Basic reference to be completed by adding the coil voltage
6
(1) (2) (3)
7
Standard control circuit voltages
a supply Volts 24 B7 B5 B6 12 JD JD JW 42 D7 D5 24 BD BD BW BD 48 E7 E5 E6 36 CD CD CW 110 F7 F5 F6 48 ED ED EW ED 115 FE7 FE5 60 ND ND ND 220 M7 M5 M6 72 SD SD SW SD 230 P7 P5 110 FD FD FW FD 240 U7 U5 U6 125 GD GD GD 380 Q7 Q5 Q6 220 MD MD MW MD 400 V7 V5 250 UD UD UD 415 N7 N5 440 RD RD RD 440 R7 R5 R6 500 S7 S5 Contactors LC1-D09D150 (coils D115 and D150 with integral suppression device tted as standard)
Contactors LC1-D09D65A (coils with integral suppression device tted as standard) U 0.751.25 Uc Contactors LC1-D80D95 U 0.851.1 Uc U 0.751.2 Uc
Contactors LC1-D115 and D150 (coils with integral suppression device tted as standard)
10
Contactors LC1-D09D38 (coils with integral suppression device tted as standard) Volts c U 0.71.25 Uc Example of complete reference LC1-D09P7
Other versions: please consult your Schneider Electric agency.
5 AL
12 JL
20 ZL
24 BL
48 EL
110 FL
120 ML
250 UL
5/4
1 000 V on a supply, 690 V on c supply 80 A 125 A 22 kW 37 kW 45 kW 55 kW 45 kW 45 kW LC1-D80 LC2-D80 25 kW 45 kW 45 kW 55 kW 45 kW 45 kW LC1-D95 LC2-D95 95 A 115 A 200 A 30 kW 55 kW 59 kW 75 kW 80 kW 75 kW LC1-D115 LC2-D115 40 kW 75 kW 80 kW 90 kW 100 kW 90 kW LC1-D150 LC2-D150 150 A
5
Set of connections LAD-9R1V LA9-D8069 LA9-D8069 LA9-D11569 LA9-9R1 LAD-9R3 LA9-D8069 LA9-D8069 Mechanical interlock included LA9-D4002 LA9-D8002 LA9-D11502 included included LA9-D50978 LA9-D80978
LC1-D09D38
with integral electrical interlocking
LC1-D80 and D95 (a) LC1-D80 and D95 (c) LC1-D115 and D150
without electrical interlocking
LC1-D09D38 LC1-D40AD65A LC1-D80 and D95 (a) LC1-D80 and D95 (c)
9
Mechanical latch blocks
Clip-on front mounting, manual or electrical unlatching control For use on contactor LC1-D09D65A a or c, LC1-DT20DT80 a or c LC1-D80D150 3P a, LC1-D80 and D115 3P a, LC1-D115 4P c Reference LA6-6K10 LA6-DK20 Standard control circuit voltages BEFMQ BEFMQ
10
5/5
TeSys D
Contactors
Auxiliary contacts
1
Contact type instantaneous, connection by screw terminals
Front mounting Contact 1 N/O 1 N/C 1 N/O 1 N/C 2 N/O 2 N/C LADN10 LADN01 LADN11 LADN20 LADN02 LADN22 LADN13 LADN31 LADN40 LADN04 Side mounting LAD8N11 LAD8N20 LAD8N02
Type de contacts
Block mounting Temporisation References On-delay Off-delay
Instantaneous
Type AC Number of poles and size 3P LC1D09D38 LC1D40AD65A LC1D8095 (50/60Hz) Side mounting on left side 1 1 1 1 1 1 1 1 1 1 1 on right side or 1 1 1 or 1 1 or 1 1 and and and and or and and and and and Front mounting 1 contact 2 2 1 1 2 contacts 1 1 and 1 and 1 1 1 1 or 1 1 1 or 1 1 1 1 and 1 1 1 4 contacts or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1
Time delay
Front mounting or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1 or 1
8
4P DC 3P
LC1D8095 (50 or 60Hz) LC1D115 and D150 LC1DT20DT40 LC1DT60AD80A LC1D115 LC1D09D38 LC1D40AD65A LC1D80 and 95 LC1D115 and D150 4P LC1DT20DT40 LC1DT60AD80A LC1D115
10
DC low consumption
3P 4P
LC1D09D38 LC1DT20DT40
5/6
TeSys D
Contactors
Suppressor modules
1
Type of module
Mounting For use with contactor References Voltage 2448 VAC 50127 VAC 110240 VAC 380415 VAC
RC circuits (Resistor-Capacitor)
Side clip-on D09D38(3P) DT20DT40(4P) LAD4RCE LAD4RCG LAD4RCU Front clip-on LAD4RC3E LAD4RC3G LAD4RC3U LAD4RC3N Screw xing LA4DA2E LA4DA2G LA4DA2U LA4DA2N
Type of module
Mounting For use with contactor References Voltage 2448 VAC 50127 VAC 110240 VAC 2448 VDC 50127 VDC 110240 VDC
4
D40AD65A(3P) DT60ADT80A(4P) D80D150(3P) D40D115(4P)
6
Type of module
Mounting For use with contactor References Voltage 24250 VDC
Flywheel diodes
Side clip-on D09D38(3P) DT20DT40(4P) LAD4DDL Front clip-on LAD4D3U Screw xing LAD4DC3U
8
Type of module
Mounting For use with contactor References Voltage 24 VAC 24 VDC 72 VAC 72 VDC 125 VDC 250 VDC 600 VDC
10
5/7
TeSys F
Contactors
90450 kW
Rated operational current Rated operational voltage Number of poles Rated operational power in category AC3
225 A 315 V 1 000 V 3 or 4 63 kW 110 kW 110 kW 110 kW 129 kW 129 kW 100 kW LC1-F225 LC2-F225
265 A 350 A 1 000 V 3 or 4 75 kW 132 kW 140 kW 140 kW 160 kW 160 kW 147 kW LC1-F265 LC2-F265
330 A 400 A 1 000 V 3 or 4 100 kW 160 kW 180 kW 200 kW 200 kW 220 kW 160 kW LC1-F330
3
Contactor type*
Reversing contactor type* * Basic reference to be completed by adding the coil voltage
5
Standard control circuit voltages
a supply Volts Contactors LC1-F115F225(0.851.1UC) 50 Hz (coil LX1) 60 Hz (coil LX1) 40400 Hz (coil LX9) Contactors LC1-F265F330U7 40400 Hz (coil LX1) Contactors LC1-F400F630U7 40400 Hz (coil LX1) Contactor LC1-F780U7 40400 Hz (coil LX1)
24 B5 B7 24 BD -
48 E5 E6 E7 E7 E7 48 ED ED -
208 L6 L7 L7 L7 L7 230 MD MW
220 M5 M6 M7 M7 M7 M7 P7 250 UD UD UD -
230 P5 P7 P7 P7 P7 P7 400 QW
240 U5 U6 U7 U7 U7 U7 P7 440 RD RD RD -
380 Q5 Q6 Q7 Q7 Q7 Q7 V7
400 V5 V7 V7 V7 V7 V7
415 N5 N7 N7 N7 N7 V7
Contactor LC1-F800U7 40400 Hz (coil LX1) c supply Volts Contactors LC1-F115F330(0.851.1UC) (coil LX4-F) Contactors LC1-F400F630(0.851.1UC) (coil LX4-F) Contactor LC1-F780(0.851.1UC) (coil LX4-F) Contactor LC1-F800(0.851.1UC) (coil LX4-F) Example: For a 630 A contactor with a 110 V a coil, order LC1-F630F7 (1) F7 for LC1-F630
10
5/8
400 A 500 A 1 000 V 2, 3 or 4 110 kW 200 kW 220 kW 250 kW 257 kW 280 kW 185 kW LC1-F400
500 A 700 A 1 000 V 2, 3 or 4 147 kW 250 kW 280 kW 295 kW 355 kW 335 kW 335 kW LC1-F500 For customer assembly
630 A 1 000 A 1 000 V 2, 3 or 4 200 kW 335 kW 375 kW 400 kW 400 kW 450 kW 450 kW LC1-F630
780 A 1 600 A 1 000 V 3 or 4 220 kW 400 kW 425 kW 425 kW 450 kW 475 kW 450 kW LC1-F780
800 A 1 000 A 1 000 V 3 250 kW 450 kW 450 kW 450 kW 450 kW 475 kW 450 kW LC1-F800
5
Auxiliary contact blocks
instantaneous
dust & damp protected contacts Composition N/O N/C 1 2 1 2 Reference LAD-N11 LAD-N20 LAD-N02 Composition N/O N/C 2 1 4 3 2 2 3 4 1 2 LAD-N22 LAD-N13 LAD-N40 LAD-N04 LAD-N31 LAD-C22 Reference Composition N/O N/C 2 2 2 2 2 2 1 1 LA1-DX20 LA1-DY20 LA1-DZ40 LA1-DZ31 Reference
Type On-delay
Off-delay
10
5/9
TeSys B
Contactors
400900 kW
Rated operational current Rated operational voltage Number of poles Rated operational power in category AC3
1000 A 1250 V 1 000 V 1 to 4 280 kW 500 kW 530 kW 560 kW 600 kW 670 kW 530 kW
1500 A 2000 A 1 000 V 1 to 4 425 kW 750 kW 800 kW 800 kW 700 kW 750 kW 670 kW
1800 A 2750A 1 000 V 1 to 4 500 kW 900 kW 900 kW 900 kW 900 kW 900 kW 750 kW
2 N/C + 2 N/O, 3 N/O + 1 N/C, 1 N/O + 3 N/C or 4 N/O Contactor type* LC1-BL LC1-BM LC1-BP LC1-BR * Basic reference to be completed by adding the coil voltage, followed by the instantaneous contact conguration.
Standard control circuit voltages (for other voltages, please consult your Regional Sales Ofce) Volts 48 110 125 127 220 a 50400 Hz c ED F FD GD G M MD
230 P -
240 U -
380 Q -
400 V -
415 N -
440 R RD
500 S -
Example: To order a 1500 A contactor with 127 V c coil with 3 N/O + 1 N/C, select LC1-BP33G31
6
Mounting accessories
Description Bar support bracket For contactor LC1-BL to BR LC1-B Reference LA9-B103 EZ2-LB0601
for mounting on 120 or 150 mm centres Mechanical interlock and locking device components
10
5/10
TeSys
CV1-B, CV3-B
Reference to compiled by the customer
Contactor type, according to required use a supply 690 V, c supply 220 V/pole a supply 1000 V, c supply 440 V/pole Contactor rating CV1: 80 A CV1: 200 A CV1: 300 A CV1: 470 A CV1: 630 A CV1: 1000 A Number of poles (PN1 main poles for CV1 and PA3 main poles for CV3) Normally Open main poles 1 N/O 2 N/O 3 N/O 4 N/O 5 N/O Normally Closed main poles 1 N/C 2 N/C 3 N/C No main poles Operational current 10 A 20 A 40 A 80 A 125 A 170 A 200 A 250 A 300 A 320 A 470 A 500 A 630 A 1000 A Control circuit voltage 48 V 110 V 120 V 208 V 220 V 230 V 240 V 380 V 400 V 440 V Operating frequency 50 Hz 60 Hz 50/60 Hz c c + economy resistor Instantaneous auxiliary contacts Normally Open 1 N/O 2 N/O 3 N/O 4 N/O Normally Closed 1 N/C 2 N/C 3 N/C 4 N/C Without instantaneous contact On-delay Off-delay 1 C/O 1 C/O CV3: 80 A CV3: 170 A CV3: 250 A CV3: 320 A CV3: 500 A
CV1-B CV3-B F G H J K L 1 2 3 4 5 1 2 3 0 Z E N P F R W G S H T J V K L 0 Z E N P F R W G S H T J V K L E F K L M P U Q V R 5 6 7 D R 1 2 3 4 1 2 3 4 0 0 J N
10
Example 1/ for single-phase capacitor switching: 400 V - 80 A - 1 N/O pole - Control circuit 220 V / 50 Hz, 1 N/O and 1 1N/C auxiliary contacts: CV1-BF1F0ZM511. 2/ for heating circuits, d.c. supply 800 V - 150 A - 2 N/O poles - Control circuit 48 V c , 1 N/O + 1 N/O On-delay auxiliary contacts: CV3-BG2W0ZED10J
Other versions: please consult your Schneider Electric agency.
5/11
TeSys
GV2-ME, GV2-P
Thermal-magnetic circuit-breakers
0.0615 kW
1
Thermal-magnetic circuit-breakers GV2-ME and GV2-P for connection by screw clamp terminals
GV2-ME with pushbutton control, GV2-P control by rotary knob Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 400/415 V P kW 0.06 Icu kA 15 15 50 15 50 15 50 10 50 50 50 50 40 50 40 50 50 50 Ics (1) 500 V P kW 0.37 0.55 0.75 1.1 1.1 1.5 1.5 2.2 2.2 3 3 4 4 5.5 5.5 7.5 7.5 9 9 11 11 15 15 18.5 18.5 Icu kA 50 10 50 10 50 6 42 6 10 4 10 4 10 4 10 100 100 100 100 100 75 75 75 75 75 75 75 75 75 75 Ics (1) 690 V P kW 0.37 0.55 0.75 1.1 1.5 1.5 2.2 2.2 3 3 4 4 5.5 5.5 7.5 7.5 9 9 11 11 15 15 18.5 18.5 22 22 Icu kA 3 8 3 8 3 3 3 6 3 6 3 6 3 6 3 6 3 4 3 4 3 4 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 Ics (1)
Setting range of thermal trips A 0.10.16 0.160.25 0.250.40 0.400.63 0.400.63 0.631 11.6 11.6 11.6 1.62.5 1.62.5 2.54 2.54 2.54 2.54 46.3 46.3 610 610 610 610 914 914 914 914 1318 1318 1723 1723 2025 2025 2432 2432
Magnetic tripping current A (d 20%) 1.5 2.4 5 8 8 13 22.5 22.5 22.5 33.5 33.5 51 51 51 51 78 78 138 138 138 138 170 170 170 170 223 223 327 327 327 327 416 416
Reference
GV2-ME01 GV2-ME02 GV2-ME03 GV2-ME04 GV2-ME04 GV2-ME05 GV2-ME06 GV2-ME06 GV2-ME06 GV2-ME07
GV2-P01 GV2-P02 GV2-P03 GV2-P04 GV2-P04 GV2-P05 GV2-P06 GV2-P06 GV2-P06 GV2-P07
GV2-ME08 GV2-P08 GV2-ME08 GV2-P08 GV2-ME10 GV2-P10 GV2-ME14 GV2-P14 GV2-ME14 GV2-P14 GV2-ME16 GV2-P16 GV2-ME16 GV2-P16 GV2-ME20 GV2-P20 GV2-ME21 GV2-P21 GV2-ME22 (2) GV2-P22 GV2-ME32 GV2-P32
7.5 9 9 11 11 15
15 H > 100 kA
10
Common accessories GV2 / GV3, see page 5/15
Other versions: please consult your Schneider Electric agency.
5/12
TeSys
GV2-L, GV2-LE
Magnetic circuit-breakers
0.06 to 15 kW
1
Magnetic circuit-breakers GV2-LE and GV2-L for connection by screw clamp terminals
GV2-LE control by rocker lever, GV2-L control by rotary knob Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 400/415 V P kW 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 0.75 1.1 1.5 1.5 2.2 2.2 3 3 4 5.5 5.5 7.5 7.5 9 9 11 11 15 15 Icu kA 15 50 15 50 15 50 15 50 10 50 50 50 50 50 40 50 40 50 50 50 Ics (1) 500 V P kW 0.37 0.55 0.75 1.1 1.1 1.5 1.5 2.2 3 3 4 4 5.5 7.5 7.5 9 9 11 11 15 15 18.5 18.5 Icu kA 50 10 10 10 6 10 6 10 4 10 4 10 4 10 100 100 100 100 75 75 75 75 75 75 75 75 75 75 Ics (1) 690 V P kW 0.37 0.55 0.75 1.1 1.5 1.5 3 3 4 4 5.5 5.5 7.5 7.5 9 9 11 11 15 15 18.5 18.5 22 22 Icu kA 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 3 4 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 75 100 Ics (1) Magnetic protection rating A 0.4 0.4 0.63 0.63 1 1 1 1 1.6 1.6 2.5 2.5 2.5 4 4 4 6.3 6.3 10 10 10 10 10 14 14 14 14 18 18 25 25 25 25 32 32 Tripping current d 20% A 5 5 8 8 13 13 13 13 22.5 22.5 33.5 33.5 33.5 51 51 51 78 78 138 138 138 138 138 170 170 170 170 223 223 327 327 327 327 416 416 LR2-K0302 LR2-K0304 or LRD-03 LR2-K0304 or LRD-04 LR2-K0305 or LRD-04 LR2-K0305 or LRD-05 LR2-K0306 or LRD-05 LR2-K0306 or LRD-06 LR2-K0306 or LRD-05 LR2-K0307 or LRD-06 LR2-K0307 or LRD-06 LR2-K0308 LRD-07 LR2-K0308 or LRD-08 LR2-K0310 LRD-08 LR2-K0312 or LRD-08 LR2-K0312 LRD-10 LR2-K0314 LRD-12 LR2-K0316 or LRD-14 LRD-14 LRD-14 LRD-16 LRD-16 LR2-K0321 LRD-16 LRD-21 LRD-21 LRD-22 LRD-22 LRD-22 LRD-22 LRD-32 LRD-32 GV2-LE03 GV2-LE03 GV2-L03 GV2-LE04 GV2-L04 GV2-LE04 GV2-L04 GV2-LE05 GV2-L05 GV2-LE05 GV2-L05 GV2-LE05 GV2-L05 GV2-LE05 GV2-L05 GV2-LE06 GV2-L06 GV2-LE06 GV2-L06 GV2-LE07 GV2-L07 GV2-LE08 GV2-L08 GV2-LE08 GV2-L08 GV2-LE08 GV2-L08 GV2-LE10 GV2-L10 GV2-LE14 GV2-L14 GV2-LE14 GV2-L14 GV2-LE14 GV2-L14 GV2-LE16 GV2-L16 GV2-LE16 GV2-L16 GV2-LE20 GV2-L20 GV2-LE22 GV2-L22 GV2-LE22 GV2-L22 GV2-LE32 GV2-L32 Use in association with thermal overload relay Reference
10
H > 100 kA (1) as % of Icu Common accessories GV2 / GV3, see page 5/15
Other versions: please consult your Schneider Electric agency.
5/13
TeSys
GV3-P/GV3-L
Circuit-breakers
Thermal-magnetic 5,530 kW with EverLink terminal blocks
1
Thermal-magnetic circuit-breakers GV3-P for connection by EverLink terminal blocks (2)
Control by rotary knob Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 400/415 V P kW 5,5 7,5 Icu kA 100 100 100 100 50 50 50 50 50 50 50 50 50 50 Ics (1) 500 V P kW 7,5 11 15 18,5 22 30 37 Icu kA 12 12 12 12 10 10 10 50 50 50 50 50 50 50 Ics (1) 660/690 V P kW 11 15 18,5 22 30 37 45 Icu kA 6 6 6 6 5 5 5 50 50 50 50 60 60 60 Ics (1)
Setting range of thermal trips A 913 1218 1725 2332 3040 3750 4865
Reference
11 15 18,5 22 30
(1) as % of lcu
Control by rotary knob Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 400/415 V P kW 11 Icu kA 100 100 50 50 50 50 50 50 50 50 Ics 500 V P kW 15 18,5 22 30 37 Icu kA 12 12 10 10 10 50 50 50 50 50 Ics 690 V P kW 18,5 22 30 45 45 Icu kA 6 6 5 5 5 50 50 60 60 60 Ics
Associated equipment Thermal overload relay LRD-22 LRD-32 LRD-3355 LRD-3357 LRD-3359
Circuit-breaker Short-circuit protection Rating A 25 32 40 50 65 Reference GV3-L25 GV3-L32 GV3-L40 GV3-L50 GV3-L65
15 18,5 22 30
Add the gure 6 to the end of the reference. Example GV3-L25 becomes GV3-L256 For motor starter solution, only 1 EverLink terminal block, add the gure 1 at the end of the reference. Example : GV3L65 becomes GV3L651 (2) BTR screw of 4 mm
Accessories
Type
10
Rfrences
2-pole busbars
GV3G364
GV36264
(3) Common add-on blocks and accessories GV2 / GV3, see page 5/15 (4) For spring terminal version add 3 to the end of the reference. Example GV-AED011 becomes GV-AED0113
Other versions: please consult your Schneider Electric agency.
5/14
TeSys
GV2/GV3
Circuit-breakers
Accessories
1
Accessories GV2
Combination block For mounting on Sets of 3-pole busbars 63 A Number of tap-offs Pitch 2 3 4 5 Protective end cover For unused busbar outlets Terminal blocks For supply to one or more GV2-G busbar sets Padlockable external operator for GV2 and GV3 (150 to 290 mm) Padlocking Handle Legend plate IP 54 For GV2-ME/P/L For GV2-LE For GV3-P/L In On and Off position black blue GV2-AP01 GV2-AP03 GV3-AP01 In Off position red yellow GV2-AP02 GV3-AP02 connection from the top GV1-G09 can be tted with current limiter GV1-L3 (GV2-ME and GV2-P) GV1-G05 GV1-G10 45 mm GV2-G245 GV2-G345 GV2-G445 54 mm GV2-G254 GV2-G354 GV2-G454 GV2-G554 GV2-G472 72 mm GV2-G272 LC1-K or LP1-K GV2-AF01 LC1-D09D38 GV2-AF3 LAD-31 and LC1-D09D38 GV2-AF4
10
5/15
TeSys
GV7-R
Thermal-magnetic circuit-breakers
0.7590 kW
1
Thermal-magnetic circuit-breakers GV7-R for connection by screw clamp terminals
Control by rocker lever
Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 400/415 V P kW 7.5 9 Icu kA 25 25 70 70 25 25 70 70 25 70 25 25 70 25 70 35 70 70 70 35 35 70 100 100 100 100 100 100 100 50 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Ics (1) 500 V P kW 9 11 9 11 11 15 11 15 18.5 22 18.5 22 37 18.5 30 45 55 45 55 45 45 55 75 75 90 75 90 110 132 160 90 110 Icu kA 18 18 50 50 18 18 50 50 18 18 50 18 18 18 50 50 18 50 30 30 50 50 30 30 30 50 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 160 10 100 75 75 90 110 90 110 160 200 8 10 8 8 10 10 8 8 100 100 100 100 100 100 100 100 55 10 100 22 30 55 10 8 8 100 100 100 Ics (1) 660/690 V P kW 11 15 11 15 15 18.5 15 18.5 22 Icu kA 8 8 10 10 8 8 10 10 8 100 100 100 100 100 100 100 100 100 Ics (1)
Setting range of thermal trips A 1220 1220 1525 1525 2540 2540 3050 4880 4880 60100 60100 90150 90150 132220
Reference
GV7-RE20 GV7-RS20 GV7-RE25 GV7-RS25 GV7-RE40 GV7-RS40 GV7-RE50 GV7-RE80 GV7-RS80 GV7-RE100 GV7-RS100 GV7-RE150 GV7-RS150 GV7-RE220
7.5 9 9 11 9 11
18.5
37
55 75 90 110
132220
GV7-RS220
(1) as % of Icu
10
5/16
1
Add-on blocks
Contact blocks Auxiliary contacts Contact type Thermal or magnetic fault discrimination z 2448 V or c 2472 V GV7-AD111 Electric trips Voltage Undervoltage trip (1) Shunt trip (1) (1) For mounting of a GV7-AD or a GV7-AU or AS 50/60 Hz 50 Hz GV7-AU055 GV7-AS055 GV7-AU107 GV7-AS107 GV7-AU207 GV7-AS207 GV7-AU387 GV7-AS387 48 V 110 130 V 200 240 V 380440 V 525 V GV7-AU525 GV7-AS525 z 110240 V GV7-AD112 C/O GV7-AE11
4
Accessories
Terminal shields IP 405 Supplied with the sealing accessory Phase barriers Safety accessories used when tting of shields is impossible Insulating screens Ensure insulation between the connections and the backplate Kit for combination with contactor Allowing link between the circuit-breaker and the contactor Rotary handles Handle Legend plate
direct extended
GV7-AC01 GV7-AC04
GV7-AC05
6
LC1-F115 to F185 GV7-AC06 black black LC1-F225 and F26 GV7-AC07 LC1-D115 and D150 GV7-AC08 red yellow GV7-AP04 GV7-AP02
IP 40 IP 55 IP 43
Conversion accessory for mounting on enclosure door Locking device For circuit-breaker not tted with a rotary handle
10
5/17
TeSys
GV3-ME
Thermal-magnetic circuit-breakers
37 kW
1
Thermal-magnetic circuit-breakers GV3-ME for connection by screw clamp terminals
Pushbutton control Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 400/415 V P kW 37 Icu kA 15 50 Ics (1) 500 V P kW 45 Icu kA 4 100 Ics (1) 660/690 V P kW 55 Icu kA 2 100 Ics (1)
Reference
GV3-ME80
(1) as % of Icu
Fault signalling contact Normal early break type contacts Electric trips Voltage 50 Hz 60 Hz 110, 120, 127 V 120, 127 V GV3-B11 GV3-D11 GV1-V02 N/C GV3-A08
Undervoltage trip Shunt trip Padlocking device Start button (for bare device) (1) + 2 volt free terminals
10
5/18
TeSys
GK3-EF
Magnetic circuit-breakers
37 kW
1
Magnetic circuit-breakers GK3-EF for connection by screw clamp terminals
Control by rotary knob Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 400/415 V P kW 37 Icu kA 35 25 Ics 500 V P kW 45 Icu kA 15 30 Ics 690 V P kW Icu kA Ics Associated equipment Thermal min. size relay LRD-3363 Circuit-breaker Short-circuit protection Rating A 80 Reference GK3-EF80
Accessories
Padlocking device for padlocking the operator, with up to 3 padlocks (padlocks not supplied) External operator for mounting on enclosure door. Red 40 pushbutton on yellow plate, can be locked in position O by means of up to 3 padlocks with door locked in position I, and door locked in position O when padlocked GK3-AP03 GK3-AV01
10
5/19
TeSys
Notes
10
5/20
TeSys DF
Fuse carriers
0.5125 A
1
Type
Rated operational voltage (Ui) Fuse size Conventional rated thermal current (ith) References Number of poles 1P N 1P+N 2P 3P 3P+N
5
Type
Rated operational voltage (Ui) Fuse size Conventional rated thermal current (ith) References Number of poles 1P 1P+N 2P 3P 3P+N
Accessories
Type
Fuse carrier to be equipped Size of cartridge fuse or link Number of contacts References
8
DF22 22 x 58 mm 2 DF14AM2 1 DF22AM1 2 DF22AM2
Type
Fuse carrier to be assembled Size of cartridge fuse or link Kit contents References
10
5/21
TeSys
LS1, GK1
Fuse carriers
0125 A
1
Fuse carriers
Rated operational voltage with links, a.c. supply Maximum continuous current for ambient temperature 40 C with links with aM fuses (mm2/A) with gG fuses (mm2/A) Conforming to standards NF EN 60947-3 IEC 947-3 Product certications Fuse carrier type min cable /le (mm2/A)
690 V 6/32 or 4/25 or 2.5/16 6/32 or 4/22 or 2.5/20 6/32 or 2.5/20 or 1.5/16 BV, UR LS1-D32
LS1-D323
GK1-E
Basic blocks
Connection Rating Cartridge fuse size
by spring terminals
25 A 10 x 38 Without LS1-D323 -
32 A 10 x 38
50 A 14 x 51
125 A 22 x 58
Without
Without
With
Without
With
10
5/22
1
Operators
Handles Number of poles, 3 or 4 For fuse carrier rating For mounting on 125 A RH side GK1-AP07
external side front
32, 50, 125 A LH side GK1-AP08 50 A RH side GK1-AP05 LH side GK1-AP06 125 A RH side GK1-AP07 LH side GK1-AP08 Fitted as standard
32 A RH or LH side DK1-FB005
Padlocking devices
For fuse carrier rating Number of poles Single-phase protection device 32 A 3 or 4 Without Integral 50 A 3 Without GK1-AV07 With GK1-AV08 4 Without GK1-AV08 With GK1-AV09
Links
Tubular links Number of poles, 3 or 4 For fuse carrier rating Reference 32 A DK1-CB92 (1) 50 A DK1-EB92 (2) 125 A DK1-FA92 (2)
(1) For use on a neutral circuit, the tubular link can be interlocked with special device LA8-D25906. (2) 4-pole fuse carriers GK1-50 and 125 A 4 are tted with an interlocked neutral tubular link as standard.
9
Add-on blocks
Contact blocks For use on Contact type Instantaneous auxiliary contacts Mounting front GV-AE11 GV-AE20 GV-AE113 GV-AE203 LS1-D32 N/O + N/C N/O + N/O LS1-D323 N/O + N/C N/O + N/O
10
5/23
TeSys
GS1
Switch-disconnector-fuses
01250 A
1
Switch-disconnector-fuse switch bodies
for use with NF C or DIN fuses
3 32 A 10 x 38 RH or LH side and front RH side LH side front front 32 A A1 RH or LH side and front front front GS1-DB3 GS1-DDB3 GS1-DD3
3 + N (1)
3 50 A 14 x 51
3 63 A 00C (2)
3 100 A 22 x 58
3 125 A 22 x 58
GS1-DD4 GS1-FD3 GS1-FG3 GS1-F3 GS1-FD4 GS1-FG4 GS1-F4 GS1-GD3 GS1-GG3 GS1-G3 GS1-GD4 GS1-GG4 GS1-G4 GS1-JD3 GS1-JG3 GS1-J3 GS1-JD4 GS1-JG4 GS1-J4 GS1-KD3 GS1-KG3 GS1-K3
100 A A4 31 mm
160 A A4 B1-B2
Type of operator:
internal or external RH side external internal and external
GS1-JBR3 GS1-JB3
GS1-JBR4 GS1-JB4
6
Auxiliary blown fuse signalling contacts for use with NF C or DIN fuses
Contact type Switch rating 1st C/O 50 A 14 x 51 3 GS1-AF13 4 GS1-AF14 100 and 125 A 22 x 58 3 GS1-AF23 4 GS1-AF24 160 A T0 3 GS1-AF33 4 GS1-AF34
9
Auxiliary early break and/or signalling contacts
Switch rating Contact type 32 A 1 N/O 1 N/C 1 C/O 2 C/O 50400 A 1 C/O 2 C/O GS1-AM2 6301250 A 1 C/O GS1-AM3 2 C/O GS1-AM4 50400 V 1 N/C + 1 N/O 2 N/C + 2 N/O GS1-AN11 GS1-AN22 GS1-ANT11 GS1-ANT22
10
5/24
3 Size 00
3 160 A Size 0
3 Size 00
3 250 A Size 1
3 400 A Size 2
3 630 A Size 3
3 1250 A Size 4
GS1-SD4
GS1-VD3
GS1-VD4
3
GS1-S4 GS1-V3 1250 A D1 GS1-V4 800 A C1C3
200 A B1-B2
250 A B1B3
315 A B1B3
400 V B1B4
630 A C1-C2
4
GS1-LBR4 GS1-LB4 GS1-MMBR3 GS1-MMBR4 GS1-NBR3 GS1-MMB3 GS1-MMB4 GS1-NB3 GS1-NBR4 GS1-NB4 GS1-PPBR3 GS1-PPBR4 GS1-QQBR3 GS1-QQBR4 GS1-SBR3 GS1-PPB3 GS1-PPB4 GS1-QQB3 GS1-QQB4 GS1-SB3 GS1-SB4 GS1-TB3 GS1-TB4 GS1-VB3 GS1-VB4 GS1-SBR4 GS1-TBR3 GS1-TRB4 GS1-VRB3 GS1-VRB4
6
2nd C/O 250 and 400 A T1 and T2 3 GS1-AF43 4 GS1-AF44 630 A T3 3 GS1-AF63 4 GS1-AF64 1250 A T4 3 GS1-AF73 4 GS1-AF74 50400 A 3 GS1-AF 4 GS1-AF 6301250 A 3 GS1-AFF 4 GS1-AFF
10
5/25
TeSys K
1
Thermal overload relays, TeSys K
adjustable from 0.11 to 12 A Connection by screw clamp terminals, direct mounting on contactors LC1-K, manual or automatic reset Relay setting range Class 10 A 0.110.16 A 0.160.23 A 0.230.36 A Fuses to be used with selected relay aM 0.25 A 0.25 A 0.5 A 1A 1A 2A 2A 2A 4A 6A 8A 10 A gG 0.5 A 0.5 A 1A 1.6 A 2A 4A 6A 6A 10 A 16 A 20 A 25 A BS88 6A 6A 10 A 16 A 16 A 20 A 20 A LR2-K0301 LR2-K0302 LR2-K0303 LR2-K0304 LR2-K0305 LR2-K0306 LR2-K0307 LR2-K0308 LR2-K0310 LR2-K0312 LR2-K0314 LR2-K0316 Reference
Thermal overload relays for use on class 10 A unbalanced loads: for above references LR2-K0305 to LR2-K0316 only, replace the prex LR2 with LR7.
5
Accessories
Prewiring kit Allowing direct connection of the N/C contact of relay LRD-0135 or LR3-D01 D35 to the contactor For use on LC1-D09D18 LC1-D25D38 Terminal blocks (1) For clip-on mounting on 35 mm mounting rail (AM1-DP200) or screw xing For independent mounting of the relay EverLink Terminal blocks LRD-0135 and LR3-D01D35 LRD-3, LR3-D3, LRD-35 LR2-K LRD-313 LRD-365 LRD-3, LR3-D3, LRD-35 LRD-0135 and LR3-D01D35 All relays except LRD-0135 and LR3-D01D35 LAD-7B10 LA7-D3064 (2) LA7-K0064 LAD-9R3 LA7-D3058 LAD-703 (4) LA7-D03 (4) LAD-7C1 LAD-7C2
Separate terminal block Terminal block adapter For mounting a relay beneath an LC1-D115 or D150 contactor Stop or electrical reset Remote (3) Tripping or electrical reset device
Remote (3)
(1) Terminal blocks are supplied with terminals protected against direct nger contact and screws in the open ready-to-tighten position. (2) To order a terminal block for connection by lug-clamps, the reference becomes LA7-D30646. (3) The time for which the coil of remote tripping or electrical resetting device LA7-D03 or LAD-703 can remain energised depends on its rest time: 1 s pulse duration with 9 s rest time; maximum pulse duration of 20 s with a rest time of 300 s. Minimum pulse time 200 ms. (4) Reference to be completed by adding the code indicating the control circuit voltage.
9
Standard control circuit voltages
a supply Volts 12 J 24 B B 48 E E 96 DD 110 F F 220/230 M M 380/400 Q 415/440 N 50/60 Hz. Consumption, inrush and sealed < 100 VA c supply Consumption, inrush and sealed < 100 W
10
5/26
TeSys D
1
Thermal overload relays, TeSys D
adjustable from 0.1 to 140 A Compensated relays with manual or automatic reset, with relay trip indicator, for a.c. or d.c. Relay setting range Fuses to be used with selected relay Connection by screw clamp terminals or connectors aM gG Class 10 A 0.100.16 A 0.25 A 2A 0.160.25 A 0.5 A 2A 0.250.40A 1A 2A 0.400.63 A 1A 1.6 A 0,631 A 2A 4A 11.7 A 2A 4A 1.62.5 A 4A 6A 2.54 A 6A 10 A 46 A 8A 16 A 5.58 A 12 A 20 A 710 A 12 A 20 A 913 A 16 A 25 A 1218 A 20 A 35 A 1624 A 25 A 50 A 2332 A 40 A 63 A 3038 A 50 A 80 A 5570 A 80 A 125 A 6380 A 80 A 125 A 80104 A 100 A 160 A 80104 A 125 A 200 A 95120 A 125 A 200 A 110140 A 160 A 250 A 80104 A 100 A 160 A 95120 A 125 A 200 A 110140 A 160 A 250 A Class 20 6A 10 A 16 A 46 A 8A 16 A 5.58 A 12 A 20 A 710 A 16 A 20 A 913 A 16 A 25 A 1218 A 25 A 35 A 1725 A 32 A 50 A 2328 A 40 A 63 A 2532 A 40 A 63 A 5570 A 100 A 125 A 6380 A 100 A 160 A Connection by EverLink terminal blocks, with BTR screws Class 10 A 913 A 16 A 25 A 1218 A 20 A 32 A 1725 A 25 A 50 A 2332 A 40 A 63 A 3040 A 40 A 80 A 3750 A 63 A 100 A 4865 A 63 A 100 A 913 A 20 A 32 A Class 20 1218 A 25 A 40 A 1725 A 32 A 50 A 2332 A 40 A 63 A 3040 A 50 A 80 A 3750 A 63 A 100 A 4865 A 80 A 125 A Class 10A with connection by lug-clamps: Select overload relay with screw clamp terminals or connectors from the table above and add one of following suffixes: b gure 6 for relays LRD01 to LRD35 and LRD313 to LRD365. b gure A66 for relays LRD3361 to LRD3365. Relays LRD43 are suitable as standard, for use with lug-clamps (1) Independant mounting on a DIN rail, order an EverLink LAD96560 terminal block. With contactor BS88 6A 10 A 16 A 16 A 20 A 20 A 25 A 32 A 50 A 63 A 80 A 125 A 125 A 160 A 160 A 200 A 200 A 160 A 200 A 200 A 16 A 20 A 25 A 25 A 40 A 50 A 63 A 63 A 125 A 125 A 25 A 35 A 50 A 63 A 80 A 100 A 100 A 35 A 40 A 50 A 63 A 80 A 100 A 125 A LC1-D09D38 LC1-D09D38 LC1-D09D38 LC1-D09D38 LC1-D09D38 LC1-D09D38 LC1-D09D38 LC1-D09D38 LC1-D09D38 LC1-D09D38 LC1-D09D38 LC1-D12D38 LC1-D18D38 LC1-D25D38 LC1-D25D38 LC1-D32 et D38 D50D95 D65D95 D80 et D95 D115 et D150 D115 et D150 D150 Montage spar Montage spar Montage spar LC1-D09D32 LC1-D09D32 LC1-D09D32 LC1-D09D32 LC1-D12D32 LC1-D18D32 LC1-D25 et D32 LC1-D25 et D32 LC1-D25 et D32 D65D95 D80 et D95 LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A LC1-D40AD65A Reference LRD 01 LRD 02 LRD 03 LRD 04 LRD 05 LRD 06 LRD 07 LRD 08 LRD 10 LRD 12 LRD 14 LRD 16 LRD 21 LRD 22 LRD 32 LRD 35 LRD 3361 LRD 3363 LRD 3365 LRD 4365 LRD 4367 LRD 4369 LRD 33656 LRD 33676 LRD 33696 LRD 1508 LRD 1510 LRD 1512 LRD 1514 LRD 1516 LRD 1521 LRD 1522 LRD 1530 LRD 1532 LR2 D3561 LR2 D3563 LRD 313 (1) LRD 318 (1) LRD 325 (1) LRD 332 (1) LRD 340 (1) LRD 350 (1) LRD 365 (1) LRD 313L (1) LRD 318L (1) LRD 325L (1) LRD 332L (1) LRD 340L (1) LRD 350L (1) LRD 365L (1)
Thermal overload relays for use with unbalanced loads Class 10A with connection by screw clamp terminals and lug-clamp terminals:
In the reference selected above, change LRD (except LRD 4ppp) by LR3D Example: LRD01 becomes LR3D01 Example with screw clamp terminal: LRD340 becomes LR3D340 Example with lug-clamp terminal: LRD3406 becomes LR3D3406
Other versions: please consult your Schneider Electric agency.
10
5/27
TeSys
LR9
Fuse to be used with selected relay aM gG 160 250 80 125 200 250 315 500 800 800
Compensated and differential or not with alarm Class 10 Class 20 LR9-D5567 LR9-F5569 LR9-F5557 LR9-F5563 LR9-F5567 LR9-F5569 LR9-F5571 LR9-F7575 LR9-F7579 LR9-F7581 LR9-F57 LR9-F63 LR9-F67 LR9-F69 LR9-F71 LR9-F75 LR9-F79 LR9-F81 Class 10 or 20 LR9-D5367 LR9-D5369 LR9-F5357 LR9-F5363 LR9-F5367 LR9-F5369 LR9-F5371 LR9-F7375 LR9-F7379 LR9-F7381
60100 90150
D115 and D150 D115 and D150 F115F185 F115F185 F115F185 F115F185 F185F400 F225F500 F225F500 F400F630 and F800
300500 380630
Accessories
Remote control Function Electrical reset (1) Reset by exible cable (length 0.5 m) Adapter for door interlock mechanism Operating head for pushbutton Spring return Rod with snap-off end Adjustable from 17 to 120 mm Insulated terminal blocks For relays LR9-F557, F563, F567, F569, F57, F63, F67 and F69 ZA2-BZ13 Set of 2 blocks LA9-F103 (1) The time for which the coil of remote electrical reset device LA7-D03 can remain energised depends on its rest time: 1 s pulse with 9 s rest time; 5 s pulse duration with 30 s rest time; 10 s pulse duration with 90 s rest time: maximum pulse duration 20 s with rest time of 300 s. Minimum pulse time: 200 ms. (2) Reference to be completed by adding the coil voltage code, see page 5/27
Other versions: please consult your Schneider Electric agency.
10
5/28
TeSys
LR/LT
1
Relay type
Relay setting range For use with contactor References 200 240 VAC 100 120 VAC 24 VAC/DC 48 VAC/DC
3
0,560 A
4
Relay type
Relay setting range References 200 240 VAC 100 120 VAC 24 VAC/DC 48 VAC/DC
Relay type
Relay setting range References 200 240 VAC 100 120 VAC 24 VAC/DC 48 VAC/DC Accessories : please consult your Schneider Electric agency.
10
5/29
TeSys T
1
Type of eldbus Modbus
24 VDC Current range 0.48 A 1.3527 A 5100 A LTMR08MBD LTMR27MBD LTMR100MBD 100240 VAC LTMR08MFM LTMR27MFM LTMR100MFM
Probus DP
24 VDC LTMR08PBD LTMR27PBD LTMR100PBD 100240 VAC LTMR08PFM LTMR27PFM LTMR100PFM
4
Type of eldbus
Supply voltage References Current range 0.48 A 1.3527 A 5100 A
CANopen
24 VDC LTMR08CBD LTMR27CBD LTMR100CBD 100240 VAC LTMR08CFM LTMR27CFM LTMR100CFM
DeviceNet
24 VDC LTMR08DBD LTMR27DBD LTMR100DBD 100240 VAC LTMR08DFM LTMR27DFM LTMR100DFM
Extension module
7
Type of module
Inputs voltage References
8
Operator dialogue terminal and software
10
Type of terminal
Description Supply voltage References
Compact display
4 lines of 20 characters 24 VDC XBTN410
Conguration software
For Windows 98, 2000, XP XBTL1000
Other versions: please consult your Schneider Electric agency.
5/30
TeSys T
1
Type of transformer
Operational current References primary secondary
External
100 A 1A LT6CT1001 LT6CT2001 LT6CT4001 LT6CT8001 200 A 400 A 800 A
Closed
65 A 30 TA30 85 A 50 PA50 160 A 80 IA80 250 A 120 MA120 400 A 200 SA200 630 A 300 GA300
Split
85 A 46 POA 250 A 110 GOA
4
PTC thermistor probe
Type of probe
Operating temperature References
Triple
90C 110C 120C DA1TT120 130C 140C 150C 160C 170C
DA1TT090 DA1TT110
Accessories (1)
7
Type of accessory
Length of cable References
Connecting cable
Controller / Extension module 0.04 m LTMCC004 0.3 m LU9R03 1m LU9R10
Type of accessory
Length of cable References (1) For other connection accessories, see www.schneider-electric.com
Connecting cable
Controller / Display 2.5 m XBTZ938
Connection kit
PC serial port VW3A8106
10
5/31
TeSys
LT3, LT6
3
3-pole multifunction protection relays 3-pole multifunction protection relays
Operational current
0.21. 15 LT6-P0M005FM
525 LT6-P0M025FM
Output contact N/C N/C N/C N/C + N/O N/C + N/O 2 C/O
On front panel: fault and voltage signalling indicator, Test and Reset button a 50/60 Hz 400 V 24/48 V 115/230 V c a 50/60 Hz1 or c 24/48 V 24230 V N/C + N/O N/C + N/O N/C + N/O N/C + N/O 2 C/O LT3-SM00V LT3-SM00E LT3-SM00M LT3-SM00ED LT3-SM00MW
Accessories
PTC thermistor probes for LT3 and LT6 relays Normal operating temperature (NOT) Integrated triple probes Normal operating temperature (NOT) 90 C 110 C 60 C 120 C 70 C 130 C 80 C 140 C 90 C 150 C 100 C 160 C 170 C DA1-TT090 DA1-TT110 DA1-TT120 DA1-TT130 DA1-TT140 DA1-TT150 DA1-TT160 DA1-TT170 DA1-TS060 DA1-TS070 DA1-TS080 DA1-TS090 DA1-TS100 Kit (1) LA9-P621 100 A 1A LT6-CT1001 (1) Comprising 2 x 3 1/2 diskettes, 1 x 2 m connection cable with 2 SUB-D 9-pin connectors (female-female) 400 A 1A LT6-CT4001 800 A 1A LT6-CT8001 Diskette
Surface probes Conguration software for LT6 relays Languages: English, French, German, Italian, Spanish For use with all relay sizes Operational current LA9-P620 primary secondary Current transformers for LT6 relays
10
5/32
Vario
1/L1
3/L2
5/L3
1
2/T1 4/T2
Type
Colour handle / Front plate Front plate dimensions (mm) Fixing Degree of protection Rated operational voltage (Ue) Thermal current in open air (Ith) 12 A 20 A
6/T3
1/L1
3/L2
5/L3
4
Vario for high performance applications
Mounting door Backplate mounting in enclosure 60 x 60 4 screws IP 20 690 V VBD02 VBD01 VBD0 VBD1 VBD2 VCF02 VCF01 VCF0 VCF1 VCF2 VCF3 VCF4 VBF02 VBF01 VBF0 VBF1 VBF2 VBF3 VBF4 90 x 90 4 screws IP 20 690 V VCF5 VCF6 60 x 60 22,5 mm 4 screws IP 20 690 V VCCD02 VCCD01 VCCD0 VCCD1 VCCD2 IP 20 690 V VCCF02 VCCF01 VCCF0 VCCF1 VCCF2 VCCF3 VCCF4 90 x 90 4 screws IP 20 690 V VCCF5 VCCF6 Red / Yellow Black / Black Red / Yellow Black / Black Red / Yellow 60 x 60 22,5 mm IP 20 690 V 12 A 20 A 25 A 32 A 40 A 63 A 80 A 125 A 175 A VCD02 VCD01 VCD0 VCD1 VCD2
2/T1
4/T2
Type
Colour handle / Front plate Front plate dimensions (mm) Fixing Degree of protection Rated operational voltage (Ue) Thermal current in open air (Ith)
6/T3
8
Add-on modules
Main pole modules Rating References Neutral pole module with early make and late break contacts Rating References Earthing module References Auxiliary contact block modules Contact types References N/O VZN05 N/C VZN06 N/O + N/C VZ7 N/O + N/O VZ20 VZN14 VZ14 VZ15 VZ16 1220 A VZN11 1240 A VZ11 63 and 80 A VZ12 125 and 175 A VZ13 12 A VZN12 20 A VZN20 12 A VZ02 20 A VZ01 25 A VZ0 32 A VZ1 40 A VZ2 63 A VZ3 80 A VZ4
For mini-Vario
For Vario
10
5/33
TeSys
GV2, LC
1
D.O.L. starters
with circuit-breaker with fuse protection Type 2 15 kW 37 kW Fuse carrier + plate-mounted contactor GV2-DP LC4-D
Coordination: Up to:
Type 1 5.5 kW incorporated in the circuit-breaker GV2-ME GV2-DM Combination automatic motor starter with overload protection
5
Starters GV2-ME
Non-reversing Standard power ratings of 3-phase motors Setting range of thermal trips 11.6 500 V 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 914 170 GV2-ME16 LC1-K12 GV2-ME16K1 GV2-ME16K2 610 138 GV2-ME14 LC1-K09 GV2-ME14K1 GV2-ME14K2 46.3 78 GV2-ME10 LC1-K06 GV2-ME10K1 GV2-ME10K2 2.54 51 GV2-ME08 LC1-K06 GV2-ME08K1 GV2-ME08K2 1.62.5 33.5 GV2-ME07 LC1-K06 GV2-ME07K1 GV2-ME07K2 Fixed magnetic tripping current 13 Irth 22.5 GV2-ME06 LC1-K06 GV2-ME06K1 GV2-ME06K2 For customer assembly Motor circuit-breaker Contactor Factory assembled Basic reference, to be completed with code indicating control circuit voltage Reversing
50/60 Hz in category AC-3 (kW) 400/415 V 0.37 0.55 0.75 440 V 0.37 0.55 0.75 1.1 1.5 2.2 4 5.5
4 5.5
Standard control circuit voltages (for other voltages, please consult your Regional Sales Ofce) Volts a 50400 Hz c (1) 24 B7 BW3 110 F7 220/230 M7 230 P7 230/240 U7 380/400 Q7 -
(1) Low consumption coil (1.5 W), wide range (0.71.3 Uc) and with integral suppression device as standard.
10
5/34
1
D.O.L. starters GV2-DM and GV2-DP
Non-reversing Standard power ratings of 3-phase motors 50/60 Hz in category AC-3 (kW) 400/415 V 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9 11 15 440 V 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9 11 15 500 V 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 9 11 15 18.5 1318 1723 2025 2432 223 327 327 416 914 170 610 138 46.3 78 2.54 51 1.62.5 33.5 GV2-ME07 GV2-P07 GV2-ME08 GV2-P08 GV2-ME10 GV2-P10 GV2-ME14 GV2-P14 GV2-ME16 GV2-P16 GV2-ME20 GV2-P20 GV2-ME21 GV2-P21 GV2-ME22 GV2-P22 GV2-ME32 GV2-P32 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D12 LC1-D25 LC1-D18 LC1-D25 LC1-D25 LC1-D25 LC1-D25 LC1-D25 LC1-D32 LC1-D32 GV2-DM107 GV2-DP107 GV2-DM108 GV2-DP108 GV2-DM110 GV2-DP110 GV2-DM114 GV2-DP114 GV2-DM116 GV2-DP116 GV2-DM120 GV2-DP120 GV2-DM121 GV2-DP121 GV2-DM122 GV2-DP122 GV2-DM132 GV2-DP132 GV2-DM207 GV2-DP207 GV2-DM208 GV2-DP208 GV2-DM210 GV2-DP210 GV2-DM214 GV2-DP214 GV2-DM216 GV2-DP216 GV2-DM220 GV2-DP220 GV2-DM221 GV2-DP221 GV2-DM222 GV2-DP222 GV2-DM232 GV2-DP232 11.6 22.5 0.631 13 0.400.63 8 0.160.25 0.250.40 Setting range of thermal trips Fixed magnetic tripping current 13 Irth 2.4 5 GV2-ME02 GV2-P02 GV2-ME03 GV2-P03 GV2-ME04 GV2-P04 GV2-ME05 GV2-P05 GV2-ME06 GV2-P06 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 LC1-D09 GV2-DM102 GV2-DP102 GV2-DM103 GV2-DP103 GV2-DM104 GV2-DP104 GV2-DM105 GV2-DP105 GV2-DM106 GV2-DP106 GV2-DM202 GV2-DP202 GV2-DM203 GV2-DP203 GV2-DM204 GV2-DP204 GV2-DM205 GV2-DP205 GV2-DM206 GV2-DP206 For customer assembly Motor circuit-breaker Contactor Factory assembled Basic reference, to be completed with code indicating control circuit voltage Reversing
Standard control circuit voltages (for other voltages, please consult your Regional Sales Ofce) Volts 24 220 a 50400 Hz c (1) B7 BD M7
9
230 P7 -
(1) Low consumption coil (1.5 W), wide range (0.71.3 Uc) with integral suppression device as standard.
10
5/35
TeSys U
1
Function characteristics, LUB + LUCA
=
Maximum motor power
< 400/415 V - Thermal overload protection against: short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipment only). - Manual reset following thermal fault. 0.09 kW 0.25 kW 1.5 kW 5.5 kW 7.5 kW 15 kW LUB12 LUB12 LUB12 LUB12 LUB32 LUB32
+
Power base
Non-reversing Reversing (1) LU2B12pp LU2B12pp LU2B12pp LU2B12pp LU2B32pp LU2B32pp
4
Function characteristics, LUB + LUCA Maximum Power base motor power Non-reversing Reversing
< 400/415 V (1) LUB12 LUB12 LUB12 LUB12 LUB32 LUB32 LU2B12pp LU2B12pp LU2B12pp LU2B12pp LU2B32pp LU2B32pp 0.09 kW 0.25 kW 1.5 kW 5.5 kW 7.5 kW 15 kW
- Thermal overload protection against: short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipment only). - Manual reset following thermal fault. - Thermal overload test function.
7
Function characteristics, LUB + LUCA Maximum motor power
< 400/415 V - Thermal overload protection against: 0.09 kW 0.25 kW 1.5 KW 5.5 KW 7.5 KW 15 KW LUB12 LUB12 LUB12 LUB12 LUB32 LUB32
Power base
Non-reversing Reversing (1) LU2B12pp LU2B12pp LU2B12pp LU2B12pp LU2B32pp LU2B32pp
short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipment only). - Manual, automatic or remote reset, - Thermal overload test function, - Overtorque and no-load running, alarm,
- Motor operation log, - Motor parameters display on LUCM.., PC or HMI, - Integrated Modbus communication. (1) Complete the references of the power bases according to the following table. (2) Complete the references of the control units according to the following table. Example: LU2B12 Example: LUCA/B/D/M6X pp pp
10
5/36
TeSys U
+
Type of optional function
Compatible with LUCA Compatible with LUCL Compatible with LUCB, LUCD Compatible with LUCM Output signal Reset References
=
Thermal overload alarm
NO NO YES NO 1 NO NA LUFW10
1
Thermal fault signalling
NO NO YES NO 1 NO +1 NC Manual LUFDH11 NO NO YES NO 1 NC Automatic or remote LUFDA01 LUFDA10 NO NO YES NO 1 NO
Communication modules
4
Type of communication
Only compatible with 24 V DC control units LUCA..BL, LUCB..BL, LUCD..BL, LUCM..BL Transfer speed Number of slaves Pre-wired coil connection (A1 A2) Connecting cable to PC References (1) Network Interface Module. 19.2 Kbps 31 per Modbus master LU9BN11C, LU9MRC Dpg. on NIM (1) 9,612 Mbps Dpg. on Network LU9BN11L, LU9MRL LU9RDDpp LUFC033 LULC15 LULC07 LULC08 Interface Module module LU9BN11L, LU9MRL TSXPBSCApp 20 K1 Mbps module LU9BN11L, LU9MRL TSXCANCpp 125500 Kbaud 167 Kbps 63 per DeviceNet module LU9BN11L, LU9MRL DeviceNet standard LULC09 ASILUFC51 LUFC00 master LU9BN11C, LU9MRC XZCG0142 TSXCDPppp NA splitter box LU9Rxx 125 per Probus DP 128 per CANopen 62 per AS-Interface 8 per LU9GC02
Modbus
YES
Advantys STB
YES
Probus DP CANopen
YES YES
DeviceNet
YES
Contact blocks
9
Type of contact block
Signalling contacts 2 auxiliary contacts module References Screw clamp terminals Without connections of any fault position of control handle
Add-on
NC (95-96) NO (17-18) LUA1C11 LUA1C110 NO (97-98) NO (17-18) LUA1C20 LUA1C200
Auxiliary
NO (33-34) NO (43-44) LUFN20 NC (31-32) NO (43-44) LUFN11 NC (31-32) NC (41-42) LUFN02
10
5/37
TeSys
LUTM
TeSys GV3L Circuit-breakers
=
Control base for use with contactors
TeSys D (LC1D..) LUTM10BL
+
Multifunction control unit
TeSys F (LC1F..) LUTM20BL Class 5 to 35 LUCMT1BL
Function characteristics
- Thermal overload protection against: short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipmemt only). - Manual, automatic or remote reset,
- Thermal overload test function, - Overtorque and no-load running, alarm, - Motor operation log, - Motor parameters display on LUCM.., PC or HMI, - Integrated Modbus communication.
ADVANCED protection
5
Function characteristics Control base for use with contactors
TeSys D (LC1D..) - Thermal overload protection against: short-circuit, overcurrent, phase failure or imbalance, insulation breaks (equipmemt only). LUTM10BL TeSys F (LC1F..) LUTM20BL
Current transformers
8
Type of transformer
24 V DC 30 A 1A LUTC0301 LUTC0501 LUTC01001 LUTC02001 LUTC04001 LUTC05001 50 A 100 A 200 A 400 A 800 A
Above 32 A, the TeSys U controller provides a motor starter management system solution identical to that provided by the TeSys U starter-controller.
10
Used in conjunction with a short-circuit protection device and a contactor, it provides a motor starter whose functions are the same as those of a TeSys U starter-controller and, in particular, provides the following functions: overload protection, motor starter control and application monitoring. It comprises a control unit, whose adjustment range is compatible with the secondary of current transformers, and a control base that also enables the tting of a function module or communication module. It requires a 24 V DC external power supply.
Other versions: please consult your Schneider Electric agency.
5/38
TeSys
LUTM
+
Type of optional function
Compatible with LUCA Compatible with LUCL Compatible with LUCB, LUCD Compatible with LUCM Output signal Reset References
=
Thermal overload alarm
NO NO YES NO 1 NO NA LUFW10
1
Motor load indication
NO NO YES YES 420 mA NA LUFV2
Communication modules
5
Type of communication
Only compatible with 24 V DC control units LUCA..BL, LUCB..BL, LUCD..BL, LUCM..BL Transfer speed Number of slaves Pre-wired coil connection (A1 A2) Connecting cable to PC References 19.2 Kbps 31 per Modbus master LU9BN11C, LU9MRC VW3 A8 306 Rpp LU9RDDpp LUFC033 LULC15 LULC08 Dpg. on NIM (1) Dpg. on Network Interface Module LU9BN11L, LU9MRL LU9RCDpp, 20 K1 Mbps 128 per CANopen module LU9BN11L, LU9MRL TSXCANCpp 125500 Kbaud 63 per DeviceNet module LU9BN11L, LU9MRL DeviceNet standard LULC09 LUFC00 TSXCDPppp NA 8 per LU9GC02 splitter box LU9Rxx
Modbus
YES
Advantys STB
YES
CANopen
YES
DeviceNet
YES
Parallele wiring
YES
10
5/39
TeSys
1
Starters
D.O.L.
0.0637 kW GV2-ME GV3-PC GV3-CE LE2-K LE2-D 0.5530 kW GV2-LC GV-NGC 0.375.5 kW LE1-GVME 0.2545 kW LE1-M LE1-D
standard
Standard power ratings of 3-phase motors in category AC3 400/415 V Starters Isolating device manual auto switch-disconnector-fuse circuit-breaker fuse carrier Protection Communication Basic reference Non reversing short-circuit overload
Reversing
10
5/40
1
safety applications AS-i bus
2 stage
7.575 kW LE6-D LE3-D
0.0611 kW GV2-ME
10
5/41
TeSys
Quickt
Installation system
Presentation
TeSys Quickt is a modular system which standardises and simplies the implementation of motor starters with its pre-wired control and power circuits.
Installation of a motor starter becomes quick, simple, safe and exible. In addition, this system: b enables the motor starter to be customised at a later date, b reduces maintenance time and b optimises panel space by reducing the number of terminals and intermediate interfaces and the amount of ducting.
The motor starters concerned are those created by combining: GV2 ME or GV3 P circuit-breakers, with an operating limit of 80% of the maximum current at an ambient temperature of 60 C, up to 690 V with 9 to 65 A TeSys D (LC1) contactors. This offer comprises components for pre-wiring
b an upstream terminal block for a power supply up to 60 A (16 mm2), b a downstream terminal block for connecting the motor power supply cables and the earth cables (6 mm2).
each starter. This module integrates the status and control information of this particular motor starter. b a parallel wiring module enabling grouping of the information relating to each motor starter: v HE 10, intended for centralised applications. The information is transmitted to the PLC via the Advantys Telefast pre-wired system. v STB, intended for decentralised automation architectures. This module is integrated in an Advantys STB conguration for connection to the PLC via a eldbus.
7
Type
Maximum c.s.a. of connection Use
Downstream
6 mm2 Motor cables LAD331
9
Type Connection kit For D.O.L. starter (1)
1 mounting plate LAD311 for GV2ME 2 power connection modules LAD341 Reference (1) For a reversing starter order 2 connection kits LAD252
Other versions: please consult your Schneider Electric agency.
10
Composition
LAD252
5/42
1
Type
TeSys D coil voltage Type of coil control relay Type of motor starter Reference
Connection module
12250 V AC or 5130 V DC Electronic Direct LAD9AP31 Reversing LAD9AP32 24 V DC Without relay Direct LAD9AP3D1 Reversing LAD9AP3D2
4
Type
PLC/motor starter side connectors Reference
5
Accessories
7
Type
Connectors Gauge / c.s.a. Reference L = 0.3 m 0.5 m 1m 2m 3m 5m
(1) From connection module LAD9AP3p to splitter box LU9G02 or module STBEPI2145
9
Connecting cable Self-stripping
Between communication module APP1Cp and splitter box LU9GG02 APP2AH40H060
Type
Use Reference
10
5/43
Components
Sodium vapour lamps
low pressure
Non corrected P (W) 31.2 6 10 12 15 21 27 35 50 100 140 152 174 198 250 338 496
high pressure
With parallel compensation 90 2.4 3 5 6 7 10 13 17 25 50 70 76 88 98 124 168 248 400 5 1 2 3 3 5 6 8 12 24 34 36 42 48 60 80 118 135 3.1 2 3 4 6 8 10 13 19 38 54 58 68 76 96 130 192 700 8.8 1 1 2 2 3 4 6 12 18 20 24 26 34 46 68 150 3.2 2 3 4 5 8 10 13 18 36 52 56 66 74 94 126 186 1000 12.4 1 1 2 2 3 4 8 14 16 18 20 24 32 48 180 3.3 2 3 4 5 7 10 12 18 36 50 54 64 72 90 122 180 200 3.4 2 3 4 5 7 9 12 17 34 48 54 62 70 88 118 174 35 0.3 17 40 50 63 86 110 140 200 400 560 606 700 792 1002 1352 1982 150 0.84 20 17 22 30 39 50 71 142 200 216 250 282 358 482 708 55 0.4 17 30 37 47 65 82 105 150 300 420 454 524 594 752 1014 1488 250 1.4 32 13 18 23 30 42 84 120 130 150 170 214 290 424 90 0.6 25 25 31 43 55 70 100 200 280 302 350 396 502 676 992 400 2.2 48 8 11 15 19 27 54 76 82 94 108 136 184 270 135 0.9 36 21 28 36 46 66 132 186 202 232 264 334 450 660 700 3.9 96 6 8 10 15 30 42 46 54 60 76 104 152 150 1 36 19 26 33 42 60 120 168 182 210 238 300 406 594 1000 5.5 120 6 7 10 20 30 32 38 42 54 74 108 LC1K09 D09, D12 D18 D25 D32, D38 D40 D50, D65 D80, D95 D115, D150 F185 F225 F265 F330 F400 F500 F630, F800 180 1.2 36 15 21 27 35 50 100 140 152 174 198 250 338 496 200 1.3 36 14 20 25 32 46 92 128 140 162 182 252 312 458 LC1K09 D09, D12 D18 D25 D32, D38 D40 D50, D65 D80, D95 D115, D150 F185 F225 F265 F330 F400 F500 F600, F800
55 1.6 5 7 9 11 16 20 26 37 75 104 114 130 148 188 254 372 250 3.2 2 3 4 5 8 10 13 18 36 52 56 66 74 94 126 186
P (W) IB (A) C (F) Max. number of lamps accordint to P (W), per contactor
7
Metal iodine vapour lamps
P (W) IB (A) C (F) Max. number of lamps accordint to P (W), per contactor
1000 9.5 1 1 2 2 3 4 6 12 18 20 22 24 32 42 62
2000 20 1 1 2 3 6 8 10 12 14 16 20 30
2000 11.2 140 5 10 14 16 18 20 26 36 52 LC1K09 D09, D12 D18 D25 D32, D38 D40 D50, D65 D80, D95 D115, D150 F185 F225 F265 F330 F400 F500 F630, F800
10
5/44
4
With parallel correction 65 0.70 13 22 30 37 50 62 80 114 228 274 296 342 388 490 662 698 2x65 2x7 2x10 2x14 2x18 2x26 2x32 2x40 2x58 2x118 2x142 2x154 2x178 2x202 2x256 2x346 2x468 80 0.80 12 20 26 32 43 55 70 100 200 240 260 300 340 430 580 786 2x80 2x5 2x8 2x12 2x14 2x20 2x26 2x34 2x48 2x96 2x116 2x126 2x146 2x166 2x210 2x282 2x384 110 1.2 8 13 17 21 29 36 46 66 132 160 172 200 226 286 386 524 2x110 2x4 2x6 2x8 2x10 2x14 2x18 2x24 2x36 2x72 2x86 2x94 2x108 2x124 2x156 2x210 2x286 20 0.17 5 56 94 123 152 205 258 329 470 940 1128 1224 1412 1600 2024 2728 3700 2x20 2x36 2x60 2x80 2x100 2x134 2x168 2x214 2x306 2x614 2x738 2x800 2x922 40 0.26 5 36 61 80 100 134 169 215 367 614 738 800 922 1046 1322 1724 2418 2x40 2x20 2x32 2x42 2x54 2x72 2x90 2x116 2x166 2x332 2x400 2x432 2x500 65 0.42 7 22 38 50 61 83 104 133 190 380 456 490 570 648 818 1104 1498 2x65 2x12 2x20 2x26 2x32 2x44 2x56 2x70 2x102 2x204 2x246 2x266 2x308 2x348 2x440 2x594 80 0.52 7 18 30 40 50 67 84 107 153 306 368 400 462 522 662 892 1210 2x80 2x10 2x16 2x20 2x26 2x36 2x44 2x58 2x82 2x166 2x200 2x216 2x250 2x282 2x358 2x482 2x654 110 0.72 16 22 29 36 48 61 77 111 222 266 288 332 378 478 644 874 2x110 LC1K09 D09, D12 D18 D25 D32, D38 D40 D50, D65 D80, D95 D115, D150 F185 F225 F265 F330 F400 F500 F630, F800 2x7 2x12 2x16 2x20 2x26 2x32 2x42 2x60 2x122 2x148 2x160 2x184 2x208 2x264 2x356 2x484 LC1K09 D09, D12 D18 D25 D32, D38 D40 D50, D65 D80, D95 D115, D150 F185 F225 F265 F330 F400 F500 F630, F800 40 0.45 21 35 46 57 77 97 124 177 354 426 462 532 604 764 1030 1398 2x40 2x11 2x18 2x24 2x30 2x42 2x52 2x68 2x96 2x194 2x234 2x254 2x292 2x332 2x420
2x20 2x0.22 2x21 2x36 2x46 2x58 2x78 2x100 2x126 2x180 2x360 2x436 2x472 2x544 2x618 2x782
10
5/45
Components
Capacitor switching
01000 kVAR
1
On-load capacitor switching
for bar-mounted contactors, a.c. control circuit
Without damping resistor Rated operational voltage (V) Number of poles Max. operational current (A) 50 Hz 1300 1 80 160 240 2 80x2 160x2 240x2 3 80x3 160x3 240x3 1500 2 poles in series 2 x 2 poles in series 2000 2 poles in series 2 x 2 poles in series 3 poles in series 160 280 280x2 240 240x2 280 180 Hz 60 125 190 60x2 125x2 190x2 60x3 125x3 190x3 125 220 220x2 190 190x2 220 CE5-FB1111 CE5-GB1111 CE5-HB1111 CE5-FB2111 CE5-GB2111 CE5-HB2111 CE5-FB3111 CE5-GB3111 CE5-HB3111 CE5-GB1211 CE5-HB1211 CE5-HB2211 CS5-HB1211 CS5-HB2211 CS5-HB1311 Basic reference, to be completed
With damping resistor Number of poles Max.operational current (A) 50 Hz 1 + 1 staggered pole 80 160 240 180 Hz 60 125 190 CE6-FB1211 CE6-GB1211 CE6-HB1211 Basic reference, to be completed
2 + 2 staggered poles
240x2
190x2
CE6-HB2211
1 + 2 staggered poles 160 280 1 + 2 staggered poles 1 + 3 staggered poles 240 280 125 220 190 220 CE6-GB1311 CE6-HB1311 CS6-HB1311 CS6-HB1411
3000
110 F
125 -
127 G
200 L
220 M
240 U
250 -
380 Q
415 N
440 R
500 S
10
5/46
1
Maximum operational power of contactors
standard contactors
Operational power at 50/60 Hz 40 C 220 V 240 V kVAR 6 9 11 14 17 22 22 35 50 60 70 80 90 100 125 180 250 250 200 300 500 600
special contactors
55 C 400 V 440 V kVAR 11 15 20 25 30 40 40 60 90 110 125 140 160 190 220 300 400 400 350 550 8350 1100 600 V 690 V kVAR 15 20 25 30 37 50 50 75 125 135 160 190 225 275 300 400 600 600 500 650 950 1300 220 V 240 V kVAR 6 9 11 14 17 22 22 35 38 40 50 60 75 85 100 125 190 190 180 250 400 500 400 V 440 V kVAR 11 15 20 25 30 40 40 60 75 85 100 110 125 140 160 220 350 350 350 500 750 1000 600 V 690 V kVAR 15 20 25 30 37 50 50 75 80 90 100 110 125 165 200 300 500 500 500 600 750 1000
Peak current
Contactor size
A 560 850 1600 1900 2160 2160 3040 3040 3100 3300 3500 4000 5000 6500 8000 10000 12000 14200 25000 25000 25000 25000 LC1-D09, D12 LC1-D18 LC1-D25 LC1-D32, D38 LC1-D40A LC1-D50A LC1-D65A LC1-D80, D95 LC1-D115 LC1-D150 LC1-F185 LC1-F225 LC1-F265 LC1-F330 LC1-F400 LC1-F500 LC1-F630 LC1-F800 LC1-BL LC1-BM LC1-BP LC1-BR
Operational power at 50/60 Hz 55 C 220 V 240 V kVAR 6.7 8.5 10 15 20 25 40 400 V 440 V kVAR 12.5 16.7 20 25 33.3 40 60 660 V 690 V kVAR 18 24 30 36 48 58 92 N/O 1 1 1 1 1 1 1 N/C 1 2 1 2 1 2 1 2 2 2 2 N.m 1.2 1.2 1.7 1.7 1.9 1.9 2.5 2.5 5 5 9 LC1-DFK11 LC1-DFK02 LC1-DGK11 LC1-DGK02 LC1-DLK11 LC1-DLK02 LC1-DMK11 LC1-DMK02 LC1-DPK12 LC1-DTK12 LC1-DWK12 Instantaneous auxiliary contacts Tightening torque on cable end Basic reference, to be completed
10
5/47
Components
1
Maximum operational current (device in open air)
Contactors
3-pole 4-pole
LC1DT20
LC1D32 DT40 50 50 18 19 31 34 36 41 54
LC1D38
LC1D40A DT60A
LC2- changeover contactor pairs, factory assembled Operational current in AC-1, in A, according to ambient temperature 40 C 60 C 70 C Maximum operational power 60 C 220/230 V 240 V 380/400 V 415 V 440 V
K12004 25 25 9 9 15 17 18 20 27 20 20 8 8 14 14 15 17 22
50 50 18 19 31 34 36 41 54
60 60 21 23 37 41 43 49 65
500 V 660/690 V
Increase in operational current by parallel connection of poles Apply the following coefcients to the currents or powers above; these coefcients take into account an often unbalanced distribution of current between the poles: 2 poles in parallel K = 1.6 3 poles in parallel K = 2.25 4 poles in parallel K = 2.8
Reference 2 poles 4 poles 2 poles with screw clamp terminals with screw clamp terminals D09D38 DT20 and DT25 (4P) DT32DT40 (4P) D40AD65A D80 LA9-E01 LA9-E02 LA9-D2561 LA9-D1261 LAD-D96061 LAD-9P32 LA9-D80961 LAD-9P3 (1) LAD-9P33 LA9-D80962 LA9-D1263 2 x LAD-9P33 LA9-D80963 LA9-FF602 LA9-FG602 LA9-FH602 LA9-FK602 LA9-FL602
TeSys D
3 poles
4 poles
TeSys F
2 to 2
10
5/48
LC1D50A
LC1D65A DT80A
LC1D115
LC1F185
LC1F225 F2254 315 280 200 100 110 175 185 200 220 300
LC1F265 F2654 350 300 250 120 125 210 220 230 270 370
LC1F330
LC1F400
LC1F500
LC1F630
LC1F780
LC1F800
LC1BL
LC1BM
LC1BP
LC1BR
D115004 F1854 250 200 80 83 135 140 150 170 235 275 275 180 90 100 165 170 180 200 280
80 80 29 31 50 54 58 65 86
80 80 29 31 50 54 58 65 86
400 360 290 145 160 250 260 290 320 400
500 430 340 170 180 300 310 330 380 530
700 580 500 240 255 430 445 370 660 740
1000 850 700 350 370 600 630 670 750 1000
1600 1350 1100 550 570 950 1000 1050 1200 1650
1000 850 700 350 370 600 630 670 750 1000
800 700 600 300 330 500 525 550 600 800
1250 1100 900 425 450 800 825 850 900 1100
2000 1750 1500 700 800 1200 1250 1400 1500 1900
2750 2400 2000 1000 1100 1600 1700 2000 2100 2700
10
5/49
Components
1
Mounting accessories for changeover contactor pairs
(for customer assembly) Contactor type 2 contactors, vertically mounted
4-pole changeover pairs with locking device components
Mechanical interlock
Contactor type
Mechanical interlock
EZ2-LB0601
LC1-DT20DT40 LP1-D80004
without electrical interlocking (2)
LAD-T9R1V (1) LA9-D8070 LAD-T9R1 (2) LA9-D8070 LA9-D80978 LA9-D8002 LC1-D115004 LC1-DT40 and DT60 LA9-D11570 LAD-T9R2 (2) LA9-D11502
LC1-DT20DT32
LP1-D80004
4-pole changeover pairs
2 contactors of identical rating, horizontally mounted LC1-F1154 LC1-F1854 LC1-F2654 LA9-FF977 LA9-FG977 LA9-FH977 LA9-FJ977 LA9-FL977 LA9-D11571
(3)
At bottom LC1-F1154 or F1505 LC1-F1854 LC1-F2254 LC1-F2654 or F3304 LC1-F4004 (3) (3) (3) (3) (3) (3) (3) (4) LA9-FF4F LA9-FG4G LA9-FG4G LA9-FH4H LA9-FJ4J LA9-FK4K LA9-FL4L LA9-FX971 (4) LC1-F185 or F1854 or LC1-F225 or F2254 LC1-F115 or F1154 or LC1-F150 or F1504
At top LC1-F185 or F1854 LC1-F225 or F2254 LC1-F265 or F2654 LC1-F300 or F3304 LC1-F400 or F4004 LC1-F500 or F5004 LC1-F630, F6304 or F800 LC1-F265 or F2654 LC1-F330 or F3304 LC1-F400 or F4004 LC1-F500 or F5004 LA9-FG4F LA9-FG4F LA9-FH4F LA9-FH4F LA9-FJ4F LA9-FK4F LA9-FL4F LA9-FH4G LA9-FH4G LA9-FJ4G LA9-FK4G LA9-FL4G LA9-FJ4H LA9-FK4H LA9-FL4H LA9-FK4J LA9-FL4J LA9-FL4K
LC1-F630, F6304 or F800 LC1-F265 or F2654 or LC1-F330 or F3304 LC1-F400 or F4004 LC1-F400 or F4004 LC1-F500 or F5004 LC1-F630, F6304 or F800 LC1-F500 or F5004 LC1-F630, F6304 or F800 LC1-F630, F6304 or F800
LC1-F500 or F5004
(1) Including mechanical interlock, (2) Order separately 2 auxiliary contact blocks LAD-N1 to obtain electrical interlocking between the two contactors, (3) Power connections to be made by the customer. (4) Double mechanical interlock mechanism with 2 interlock connecting rods and 4 power connecting links.
10
5/50
TeSys
Notes
10