visualization and measurements. The species to be examined is excited with a laser. The wavelength is often selected to be the one at which the species has its largest cross section. The excited species will after some time, usually in the order of few nanoseconds to microseconds, de-excite and emit light at a wavelength larger than the excitation wavelength. This light, fluorescence, is measured. Two different kinds of spectra exist, disperse spectra and excitation spectra. The disperse spectra are performed with a fixed lasing wavelength, as above and the fluorescence spectrum is analyzed. Excitation scans on the other hand collect fluorescent light at a fixed emission wavelength or range of wavelengths. Instead the lasing wavelength is changed. An advantage over absorption spectroscopy is that it is possible to get two- and threedimensional images since fluorescence takes place in all directions (i.e. the fluorescence signal is isotropic). The signal-to-noise ratio of the fluorescence signal is very high, providing a good sensitivity to the process. It is also possible to distinguish between more species, since the lasing wavelength can be tuned to a particular excitation of a given species which is not shared by other species. LIF is useful in the study of the electronic structure of molecules and their interactions. It has also been successfully applied for quantitative measurement of concentrations in fields like combustion, plasma, spray and flow phenomena (such as Molecular tagging Velocimetry), in some cases visualizing concentrations down to nanomolar levels.
Field-screening methods do not eliminate the need for laboratory analyses, but they substantially reduce the number of samples and improve the efficiency of sample collection. The LIF technology has only been validated as a semi-quantitative methodology (detect/nondetect); it does not completely eliminate the need for traditional sampling. As the technology is now applied, random samples are taken to the laboratory to confirm that the results are accurate and to recalibrate the LIF sensor. Detection limits vary among sites. The range of detection levels is 10-100 parts per millions (ppm) in soil and 0.5-10 ppm in groundwater. Minerals such as calcite, naturally occurring organic matter, and man-made chemicals also can fluoresce, possibly causing interference problems. Extensive experience is required for proper system operation. The maximum depth for this technology is 150 feet, due to signal attenuation in the optical fiber cord. The space above the truck must be free of obstructions such as power lines, and the subsurface in the immediate vicinity of a cone penetrometer push must be free of buried objects such as utilities. The cone penetrometer probes will not penetrate boulders, cobbles, rubble, well compacted sediment, or sound bedrock. Cold weather may cause problems by freezing of parts of the cone penetrometer system. These systems may be expensive to use on small-scale projects. They have primarily been used at large sites such as Department of Defense (DoD) and Department of Energy (DOE) facilities. Some maintenance of the cone penetrometer tools and the LIF sensors is required. Downtime due to the breakage of fiber optic cables and push rods, as well as fogging of the sapphire window, may occur. Work performed at Dover Air Force Base indicated the potential for smearing as well as a memory effect on the sensor.
Applicability
The LIF sensor is attached to a cone penetrometer such as the SCAPS, to detect petroleum hydrocarbons in the soil. This approach partially replaces the slow, costly traditional approach, in which subsurface contaminant plumes are characterized using a drilling rig to install monitoring wells and collect soil and groundwater samples that are sent to a laboratory for analysis. The LIF system can also be to detect petroleum compounds in water. It is best used for screening petroleum compounds and polycyclic aromatic hydrocarbons and for monitoring cleanup performance.
The laser-induced fluorescence (LIF) petroleum sensor has been field-tested and is considered commercially available.