■ Overview
• 1LA8 for converter-fed operation
- Converter-fed operation, optimised for the SINAMICS and
SIMOVERT MASTERDRIVES drive systems
- Degree of protection: IP55
- Cooling method: IC411, self-ventilated
- Housing: Cast iron
3 - With standard insulation for voltages 500 V or with special
insulation for 690 V
Series 1PQ8
The motors are asynchronous squirrel-cage motors with com-
pact dimensions in fin-cooled design with a separately driven
fan. As these motors are forced-ventilated, no derating or only
relatively minor derating (depending on their speed range) is
required for operation at constant load torque and with wide
speed ranges. The motors are designed for converter-fed
operation with the SINAMICS and SIMOVERT MASTERDRIVES
drive system.
- Converter-fed operation
- Degree of protection: IP55
N compact three-phase asynchronous motors: Series 1LA8,
- Cooling method: IC416, forced-air cooling
1PQ8, 1LL8
- Housing: Cast iron
The three-phase motor series N compact covers outputs up to - With standard insulation for voltages 500 V or with special
1250 kW (at 50 Hz) in the non-standard range. A number of insulation for 690 V
technical features provide this motor series with its ruggedness
Series 1LL8
and long service life and ensure the highest level of availability.
The motors of series 1LL8 are asynchronous squirrel-cage mo-
N compact motors are also characterised by their high output for
tors with compact dimensions in an open fin-cooled design with
small frame size. The consequence of this is an extremely com-
self-cooling. They are similar in construction to 1LA8 motors.
pact design that can be used to save space in a number of in-
IP23 degree of protection is achieved by opening the internal
dustrial applications.
cooling circuit and supplying it with external cooling air. This can
N compact motors are not only optimised in terms of their con- increase the performance by up to 25% as compared to the
struction, but also in terms of their efficiency, so they also con- 1LA8. They are designed for direct connection to the three-
tribute towards lower energy consumption. phase supply and for converter-fed operation.
Apart from mains-fed operation, the motors of the series N com- Motors of the 1LL8 type series are intended for installation in-
pact are also specially designed for converter-fed operation. In doors. They must not be subjected to humid, salty or corrosive
combination with frequency converters from the SINAMICS and atmospheres.
SIMOVERT MASTERDRIVES product series, they build up per- • 1LL8 for mains-fed operation
fectly interacting drive systems for variable-speed drive applica- - Mains-fed operation
tions. - Degree of protection: IP23
Versions in the N compact series - Cooling method: IC01, self-ventilated
- Housing: Cast iron
Series 1LA8
• 1LL8 for converter-fed operation
The motors are asynchronous squirrel-cage motors with com- - Converter-fed operation
pact dimensions in fin-cooled design. They are designed for - Degree of protection: IP23
direct connection to the three-phase supply and for converter- - Cooling method: IC01, self-ventilated
fed operation. - Housing: Cast iron
• 1LA8 for mains-fed operation Versions with special insulation for >500V and operation without
- Designed for operation on the three-phase supply an output filter on the frequency converter are only possible on
- Degree of protection: IP55 request.
- Cooling method: IC411, self-ventilated
- Housing: Cast iron
■ Benefits
Non-standard motors from Siemens offer the user numerous • The bearings are designed for maximum reliability, which
advantages: results in good vibration characteristics, a long service life
• The optimised efficiency results in lower operating costs. and low maintenance costs.
• The high output/size ratio ensures low space requirements • The DURIGNIT IR 2000 insulation system with VPI or current-
combined with low weight. UV impregnation results in high reliability, a long service life
and high resistance to stress, for example, during starting or
• The cast-iron housing and bearing plates are extremely rigid under overload conditions.
and rugged and can therefore be subjected to considerable
stress and have excellent vibration damping properties and • Due to the low noise emission level, the stringent requirements
are resistant to corrosion. of worker protection are fulfilled without the need for additional
measures.
■ Application
Thanks to the many options, the three-phase motor series N The low-voltage motor series N compact is also available in a
compact covers applications in a wide range of different sec- through-ventilated version to IP23 degree of protection. This
tors: Chemicals, paper, water/waste water, steel and shipbuild- 1LL8 motor series boasts an output 25 % higher than that of the
ing are just a few examples. The available types of construction closed 1LA8 motor series for the same frame size.
are IM B3, IM B35 and IM V1 according to DIN EN 60034-7. The The 1LL8 motor is therefore useful for applications in which a
degree of protection is IP55 as standard, but IP23 for motor closed 1LA8 motor is not essential and when the ambient condi-
series 1LL8.
The 1PQ8 motors are specially designed for variable-speed ap-
tions permit the use of a through-ventilated machine (IC 01 cool-
ing method, IP23 degree of protection). Motors of the 1LL8 type 3
series are only intended for installation indoors. They must not
plications with constant torque. The mounted separately driven be subjected to humid, salty or corrosive atmospheres.
fan provides a constantly high cooling air flow at any speed.
These motors can therefore be continuously operated at low
speed and high torque simultaneously.
■ Design
The basic structure of the non-standard motors is shown in the In conventional fin-cooled motors, the one-sided external venti-
following sectional diagram. lation naturally results in an uneven temperature distribution -
this is however not the case with N compact motors with their
additional internal air-flow channels. This cools, in particular,
the stator winding heads, the rotor winding and the drive-end
bearings. The resulting reduction in thermal loading increases
the operating reliability and lengthens the service life.
The internal air-flow channels increase the efficiency of the ven-
tilation which means that the external air-flow can be reduced.
The lower volumetric flow and air-flow optimisation of all guide
channels results in a low level of fan noise.
G_D081_XX_00062
G_D081_XX_00063
G_D081_XX_00064
■ Technical specifications
The following table lists the most important technical specifica-
tions. For further information and details, see the "Introduction"
section of the catalogue.
Technical specifications at a glance
Type of motor Squirrel-cage induction motor
18 S.F . 1.10
conductor cross-sections permitted for the converter.
Ventilation/noise generation
The fan noise can increase at speeds that are higher than the
rated speed of self-ventilated motors (this is not the case for
forced-air cooled motors 1PQ8). To increase motor utilisation at
1 Motor type: 3-phase LV motor 9 Motor weight [kg] low speeds it is recommended that forced-air cooled motors are
2 Type of construction 10 Temperature class used, e.g. those of series 1PQ8.
3 Degree of protection 11 Rated speed [rpm]
4 Rated voltage [V] and circuit 12 Rated frequency [Hz] In general, for converter-fed operation, the noise level is higher
5 Rated current [A] 13 Power factor [cos φ] than that specified in the catalogue (exception: 1PQ8). The
6 Rated output [kW] 14 Maximum speed [rpm] increase depends on the converter type and can lie between
7 Standards and regulations 15 Motor type 5 and 10 dB(A) depending on the frame size and number of
e.g. explosion-proof motors 16 Rotor class poles for the motor.
8 Serial number 17 Additional details (optional)
18 Service factor Mechanical stress and grease lifetime
When motors are operated at speeds above the rated speed,
the running smoothness and the bearings are subjected to
Example of rating plate for 1LA8
greater mechanical stress. This reduces the grease lifetime and
the bearing lifetime. More detailed information on request.
Converter-fed operation Storage
The motors are equipped with standard rotors and are suitable To prevent damage being caused as a result of bearing currents,
for mains-fed or converter-fed operation. insulated bearings are used at the non-drive-end of 1LA8, 1LL8
All motors can therefore be operated with a converter, in princi- and 1PQ8 motors for converter-fed operation in the standard
ple. Special measures are necessary in the case of some version (this can be recognised when 9th position of Order No.
motors, especially when separately driven fans are used. = "P").
All data are applicable for a 50 Hz sinusoidal supply.
When operating multiphase induction machines on a converter,
Rated voltage an electrical bearing stress results from a capacitive induced
The tolerance for the rated voltage is in accordance with DIN voltage via the bearing lubricating film, depending on the princi-
EN 60034-1 in all cases, a rated voltage range is not specified. ple being used. The physical cause of this is the common-mode
voltage at the converter output that is inherent in the control
Motor protection method for a converter: the sum of the three-phase voltages is
– in contrast to straightforward mains-fed operation – not equal
A motor protection function can be implemented using the I2t
to zero at every point in time. The high-frequency, pulse-shaped
detection present in the converter software.
common-mode voltage brings about a residual current, which
If required, more precise motor protection can be afforded by closes back to the converter's DC link via the machine's internal
direct temperature measurement using KTY84 sensors, PT 100 capacitances, the machine housing and the earthing circuit. The
resistance thermometers or PTC thermistors in the motor wind- machine's internal capacitances include the main insulation
ing. Some converters from Siemens determine the motor tem- winding capacitance, the geometric capacitance between the
perature using the resistance of the temperature sensor. They rotor and stator, the lubricating film capacitance and the capac-
can be set to a required temperature for alarm and tripping. itance of any bearing insulation that may be present. The level
If PT 100 resistance thermometers are ordered for cooling tem- of the currents due to the internal capacitances is proportional
perature monitoring (order code A61) or KTY84 temperature to the gradients, i.e. the voltage variation of the DC voltage
sensors (order code A23), the standard thermistors are omitted. (i(t) = C ¼ du/dt).
0.8
0.7
Field weakening
0.6
0.5
0.4
0.3
0.2
0.1
0
0 0.2 0.4 0.6 0.8 1.0 1.2 f/frated 1.4
Frequency