Generating Set SIS-400

Stand-by Power at 50Hz: 352 kWe / 440 kVA Prime Power at 50Hz: 320 kWe / 400 kVA
General Features
Engine (IVECO aifo: C13 TE3) Governor: Electronic Alternator (STAMFORD or equivalent) Single bearing alternator IP 23 Radiator 50 C Skid and vibration isolators Electric control panel
o

Main line circuit breaker 24 V battery, rack and cable Flex exhaust connection (loose) Industrial silencer (loose) Subbase daily fuel tank User manual

Illustrations may include optional equipment and/or properties.

Generator Ratings
Voltage
415/240 400/230 380/220

Hz
50 50 50

Phase
3 3 3

P.F
0.8 0.8 0.8

Stand-by Amps
612 635 669

Stand-by Ratings kWe / kVA


352 / 440 352 / 440 352 / 440

Prime Ratings kWe / kVA


320 / 400 320 / 400 320 / 400

Stand-by ratings are available for the duration of any power outage. No overload capacity is specified at this ratings. Prime ratings are available per BS 5514, DIN 6271, ISO-3046 and IEC 34-1 with 10% overload capacity one hour in twelve hours.

Weight and Dimensions Open Type

Enclosure Type

L x W x H (mm): 3,310 x 1,390 x 1,900

Weight (kg): N.A.

Fuel Tank (lt): 600

L x W x H (mm): 4,100x 1,600 x 2,209

Weight (kg): N.A.

Fuel Tank (lt): 600

Generating Set SIS-400


Engine Data
Manufacturer Model Aspiration Cylinder Arrangement Displacement Bore and Stroke Rated Speed Max. stand-by Power (net) Governor type Fuel System 100% (Prime Power) 75% (Prime Power) 50% (Prime Power) Oil System Total oil capacity w/filters Oil Pressure rated RPM Oil consumption full load Air Intake Engine air flow Coolant System Radiator & engine capacity Max water temperature Fan power Fan air flow Restriction air flow Type of coolant 67 L o 98 C [208 F] N.A. N.A. N.A. antifreeze liquid coolant
o

Alternator Data
IVECO aifo C13 TE3, 4-cycle Turbocharger & Aftercooler 6 in line 12.9 L 135 mm X 150 mm 1,500 rpm 387 KWm Electronic Manufacturer Type Number of phase Power factor (cos ) Poles Insulation class Temperature rise Voltage regulator Volts regulation 0 to 100% load o Continuous rating at 40 C Efficiencies at 4/4 load Air flow STAMFORD HCKI 444 F 3 0.8 4 H H SX440 +/-1% 400 kVA 93.4 % 0.68 m3/s

81.3 l/h 63.8 l/h 41.9 l/h

Compliance with CEI 2-3, EN 60034-1, IEC 34-1, VDE 0530, BS 4999-5000

35 L N.A. <0.1% of fuel consumption

Control Panel Data


Specifications Frequency meter, Ammeter, Voltmeter Alarms and faults Oil pressure, Water temperature, Start failure, Overspeed, Min/max battery voltage, Low fuel level, Emergency stop Engine parameters Hours counter, Oil pressure, Water temperature, Engine speed, Battery voltage, Fuel level

N.A.

Options
Engine and radiator Battery charger Coolant heater Exhaust Residential silencer Alternator Anti condensation heater
SUNLIGHT SYSTEMS S.A. reserves the right to modify any characteristics without prior notice.

Control panel Key start mode AMF mode Remote control Auto start mode

Enclosure Silent

SUNLIGHT SYSTEMS S.A. Headquarters 23rd klm. National Road Athens-Lamia 145 65 Ag. Stefanos Attica, Greece Tel.: +30 210 6242000 Fax: +30 210 6216911

Manufacturing Plant Neo Olvio 67 200 Xanthi, Greece Tel.: +30 25410 48100 Fax: +30 25410 95446

www.sunlight.gr