PLASMA TOP 10 TIPS MODELS

PDP-433CMX Page 3 PDP-434CMX Page 5 PDP-4300HD Page 3 PDP-4304HD Page 5 PDP-4310HD Page 3 PDP-4314HD Page 5 PDP-4330HD Page 3 PDP-4331HD Page 3 PDP-4340HD Page 5 PDP-502MX Page 6 PDP-505HD Page 6 (ADDITIONAL INFORMATION) Page 4 (ADDITIONAL INFORMATION) Page 4 (ADDITIONAL INFORMATION) Page 4 (ADDITIONAL INFORMATION) Page 4

PDP-503CMX Page 3 PDP-504CMX Page 5 PDP-5004HD Page 5 PDP-5014HD Page 5 PDP-5030HD Page 3 PDP-5031HD Page 3 PDP-5040HD Page 5 PRO-800HD Page 3 PRO-810HD Page 5 PRO-910HD Page 5 PRO-1000HD Page 3 PRO-910HD Page 5 PRO-1010HD Page 5 PRO-1110HD Page 5

(ADDITIONAL INFORMATION) Page 4 (ADDITIONAL INFORMATION) Page 4

(ADDITIONAL INFORMATION) Page 4 (ADDITIONAL INFORMATION) Page 4

(ADDITIONAL INFORMATION) Page 4

(ADDITIONAL INFORMATION) Page 4

1. Red LED slowly blinks 1 time continuously. - Trap switch detect. Unit powered up with back off and trap switch open. Unit must be put in factory mode to clear. From standby, Menu, Enter and Power. (Enter, Display, Power some units). 2. Power supply from parts dept. is different part #. Power supply is upgraded with new # AXY1064. 3. Screen displays E06. - Remove AC, then power on. If still get E06, replace power supply. 4. Unit shuts down and LED blinks Red or Green. Unit is in protection mode. See bulletin SK-D03001 to diagnose. 5. Fan is always on. - Check connector CN5505 (R8) on RGB board. 6. Scan ICs are different. - Units originally had SN755860PJ. Units with serial #s _ _ SS use SN755864APZP. 7. No audio from any input. - Reset media receiver by opening door, hold down switch while powering on. 8. Unit shuts down, red LED blinks 5 times. - Replace power supply 9. After approx. 15 minutes horizontal white band . - Check R6020 on scan A assy. 10. Alternate red and green box on screen. - System cable between panel and media receiver unplugged.
3

1. Display says out of range. - Unit must have video card to use. Without card only computer video input can be used.

1. Red LED blinks continuously. - Trap switch detect. Unit powered up with back cover off. - Enter factory service mode, go to initialize page and hold down display button 3 seconds. 2. Factory service mode. - From standby with remote display key, wait 4 seconds, then rapidly with arrow keys left, up, left, right then power on. 3. HDMI input doesn't work. - HDMI must be inputs 1 or 3 and enabled. Open user menu, select option, select HDMI input select setting and toggle enabled/disabled. 4. No video inputs 1 or 3. - Check HDMI enabled/disabled as above. 5. Powers up, stays on but no video. - Replace X Drive Assy. 6. Remote doesn't work. - From standby with remote key enter, power and select SR+ for remote or 232C for RS232. 7. Alternate red and green box on screen.- System cable between media receiver and panel unplugged. 8. Shuts down and red LED blinks 2 times. - Replace Power Supply Assy. 9. Shuts down and red LED blinks 5 times. - Replace Y Drive Assy. 10. Shuts down and red LED blinks 9 times. - Replace X Drive Assy.
5

1. Won't turn on, green LED blinks 5 times. - Replace Power Supply 2. Power Supply is Different - Power supply is upgraded, Part # by 1st number in serial #.0 = AWV2009, 1 = AWV2010 3. Intermittent Shutdown - Check LEDs on back. If D439 is lit replace Digital Video. If D437 is lit replace Y Drive Assy. 4. Display says Temperature Warning, Please Shut Down- Check Sensor Cable E27 on Control Assy. 5. Menu Items are "Grayed Out" - Unit must sense video at inputs for items to be selected. 6. Horizontal band 1/4 of picture is bad. - Replace Scan Module that corresponds to band location. 7. Pink or Orange Blotching. - Adj. Vofs and Vh voltages per Service Bulletin. 8. Service Mode - On Remote on side panel from Standby mode push "enter", "set" and "power" within 3 seconds. 9. Powers down when switching inputs. - Replace Digital Video Assy. 10. Bottom 1/4 of picture is repeated over 3rd 1/4 of picture. - Y Drive Assy.