Sunteți pe pagina 1din 20

Filter Retuning Demonstration

D i lF Daniel Fallon, ll S Sr. RF E Engineer i


GLOBAL INFRASTRUCTURE X PROCESS EQUIPMENT X DIAGNOSTIC TOOLS

COMPANY CONFIDENTIAL

Filter Tuning Retune 150 Watt Filter from ch 42 to ch 30 Uses Agilent Time Domain Tuning Technique Agilent AN1287-8 Simplified Filter Tuning Using Time Domain Requirements VNA with time domain option (8753ES / EN5071) ) 7/8 deep socket wrench wrench (deep socket preffered) 1/16 Allen Wrench
GLOBAL INFRASTRUCTURE X PROCESS EQUIPMENT X DIAGNOSTIC TOOLS

COMPANY CONFIDENTIAL

7/28/2012

Sequence Capture p memory y trace of tuned filter Set frequency of new channel and recalibrate Preset all coupling loop depths Set input coupling and resonator 1 (each side) Rough tune resonators 2 and 3 (each side) Time domain fine tune res 1 to 3 (each side) S21 fine tune cross coupling Time domain fine tune all F Frequency domain d i fi finishing i hi t touches h centering t i / bandwidth / frequency Lock down
GLOBAL INFRASTRUCTURE X PROCESS EQUIPMENT X DIAGNOSTIC TOOLS
COMPANY CONFIDENTIAL 7/28/2012 3

100/150/200 Watt Filter

COMPANY CONFIDENTIAL

Resonators, Fine matchers and Loops

COMPANY CONFIDENTIAL

Initial Channel Measurement

Span 30 MHz Full two Port Cal Shown with limits LPTV Stringent Mask
6

COMPANY CONFIDENTIAL

Coupling Presets

All coupling loops and Cross coupler position pre-set to height off case from chart

COMPANY CONFIDENTIAL

Coupling Heights

Cross Coupler Height

Coupling Loop Height

COMPANY CONFIDENTIAL

Loosen all resonators

COMPANY CONFIDENTIAL

Resonator # 1 and input coupling tune

COMPANY CONFIDENTIAL

10

Rough In Resonator #2

COMPANY CONFIDENTIAL

11

Rough In Resonator #3

COMPANY CONFIDENTIAL

12

Initial Time Domain Tune

COMPANY CONFIDENTIAL

13

Adjust Cross Coupling

COMPANY CONFIDENTIAL

14

Bandwidth Adjust

COMPANY CONFIDENTIAL

All loops deeper = wider filter


15

Frequency Adjust

All fine matchers into cavity= tune down


16

COMPANY CONFIDENTIAL

Fine Tune in Time Domain


COMPANY CONFIDENTIAL

S11 Log Mag Mag, display data and memory Band-pass time domain transform Start time -20 ns, stop time ~650 ns
17

Polar Plot Centering

Input coupling and resonator 1


18

COMPANY CONFIDENTIAL

Lock Down Tuned Filter

Put tuned filter into memory, do one screw at a time


19

COMPANY CONFIDENTIAL

CONCLUSIONS Tuned filter can serve as a template for new channel Time domain option on VNA makes tuning much easier Dielectric offers one time re-tuning with low power filters

COMPANY CONFIDENTIAL

20