SPC Series SPC42xx/43xx/52xx/53xx/63xx Firmware Release Note


SPC42xx43xx52xx53xx63xx_V3.2.2
CONTENT No storage of firmware on SPCX410 Fast Programmer .......................... 2 No direct upgrade possible for firmware versions 2.0.x or older .............. 2 SPC Pro (PC Programming Software) requirements ............................... 2 New Region option added for Spain........................................................ 2 New Fault Input types to handle Fault Conditions ................................... 2 New confirmation mode EN50131-9 added............................................. 2 New Menu Option Failed to Set added ................................................. 4 Viewing of Inhibited, Isolated Zones or Zones in Soak Test .................... 4 Multiple Input Activations are Logged 8 Times in a Set Period ................ 4 Various alterations for EN50131 compliance .......................................... 5 Antimask in Unset will now Cause Trouble by default ............................. 5 ZONE Masking Latched .......................................................................... 5 Change to Zone Attributes for Holdup and Tamper ................................. 5 Change to Operation of Line Fault Zone Type ........................................ 5 Selectable User Rights for Seismic Test ................................................. 5 Change to minimum timer for Strobe/Bells for Belgium ........................... 6 Zone Alerts Display Changed on Keypad................................................ 6 Random Test Call Times ........................................................................ 6 Added Access Events Reported over EDP or to SPC Pro....................... 7 EDP zone status expanded..................................................................... 7 Fast Format Low Battery Option ............................................................. 7 Change to CID code for hold up zone ..................................................... 7 Web Page Language not latched ............................................................ 7 Panel Doesnt Send the Panel Unset Flag over EDP .............................. 7 X-Bus node reporting AC Power Failure over EDP ................................. 7 Fail to set not reported for CID ................................................................ 7 Modem Fault not reported over SIA or EDP ............................................ 7 No correct Toggling of test Channels of Redcare Modem ....................... 7 SMS Stops working after 5 Minutes of SMS messages........................... 8 No manual Test Call to ARC when selected from Keypad....................... 8 SPC Safe Reporting Timer not Working .................................................. 8 Time Locked Areas Not Unsetting........................................................... 8 Line fault zone type causing bells when full set....................................... 8 Unset with Card Reader not possible if Part Set ..................................... 8 Users reset changes Engineer PIN ......................................................... 8 Using pace did not update user language ............................................... 8
01.03.2012 Updates since: SPC42xx43xx52xx53xx63xx_V3.1.0

Feature type
(related languages)

s Building Technologies Division: Security Products

Page: 1 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

No storage of firmware on SPCX410 Fast Programmer This firmware cannot be stored on SPCX410 Fast Programmer with 1 MB memory due to file size. Download only via Web-Browser or SPC Pro. No direct upgrade possible for firmware versions 2.0.x or older The direct upgrade from firmware version 2.0.x (or older) to V3.x is not possible. In this case its necessary to upgrade to V2.1.x first. Note: The firmware can be found on product CD in the same folder as the V3.x firmware release. Note: When upgrading older panels with new firmware not all new SPC features are supported (see release note for V3.1.0) SPC Pro (PC Programming Software) requirements This firmware is supported with SPCS310 SPC Pro release 3.2.0 or higher. New Region option added for Spain The Spanish Region can now be selected in order to comply with Spanish standard requirements, in particular the alarm confirmation. New Fault Input types to handle Fault Conditions There are three new trouble types for detectors and signalling devices, namely: Detector Fault Holdup Fault Warning Fault Detector Fault is a rename of the existing Fault input type. Holdup Fault and Warning Fault (an abbreviation for Warning Device Fault) are new input types.These new types will be available to all types of installations and all grades. Reporting Open, Disconnect, Short Detector Fault Hold-up device Fault Warning Device Fault BT HT YA SIA Restore BJ HJ YH CID Open, Disconnect, Short 380 380 380

IMPORTANT

GENERAL

GENERAL

NEW
ES

NEW
All

New confirmation mode EN50131-9 added The following new attributes have been added to system setting options: New confirmation mode EN50131-9 (in addition to GARDA and DD243) to enable alarm confirmation according to EN50131-9. New option Confirmation Zones in order to define the number of zone activations for confirmed alarm when confirmation mode EN50131-9 is selected.
s Building Technologies Division: Security Products

NEW
All

Page: 2 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

Default operation of confirmation mode EN50131-9: In order to be considered a confirmed alarm there must be three activations (resp. as configured with Confirmation Zones), these activations can be either an open or a tamper condition. Therefore a single zone may supply two activations to the confirmation. The following activations will cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 1 tamper + ZONE 2 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 2 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 alarm - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper, The following activations will NOT cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 2 alarm + ZONE 1 alarm - ZONE 1 alarm + ZONE 1 alarm + ZONE 1 alarm The alarm must be confirmed within 30 minutes in order to be considered a confirmed alarm. If an alarm is not confirmed within this 30 minute window, the zone will either be restored if it is closed or inhibited if it is open. The activation of the following events (in addition to alarm and tamper) will also start a 30 minute timer and during this window any further alarm activations will be considered a confirmed alarm: Modem fault System tamper (e.g Bell tamper, Antenna tamper, Jamming, Cabinet tamper, Aux tamper, Aux 2 tamper, Xbus Tamper, Xbus communications) In the case that the entry route zone has been inhibited a special entry procedure is enabled in order to prevent false alarms. The first alarm zone that is activated in the entry route is inhibited and this will start the entry timer. Configuration: Confirmation Mode EN50131-9 can be selected in all Regions and all Grades. If EN50131-9 is selected the Confirmation Zones can be changed from 2 to 10 (default = 3). Exception for Spanish Region For EN50131 grade 2: Three unique zones must be activated however the activation can be an alarm or tamper condition. The following activations will cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 alarm - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper,
s Building Technologies Division: Security Products

Page: 3 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

The following activations will NOT cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 1 tamper + ZONE 2 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 2 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 1 alarm - ZONE 1 alarm + ZONE 1 alarm + ZONE 1 alarm For EN50131 grade 3: There must be three activations from 2 detectors and these activations can be of any type. Therefore a single zone may contribute two open conditions to the confirmation however a second zone must supply another alarm condition in order to be considered confirmed. The following activations will cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 1 tamper + ZONE 2 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 2 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 alarm - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 alarm - ZONE 1 tamper + ZONE 2 tamper + ZONE 3 tamper - ZONE 1 alarm + ZONE 2 alarm + ZONE 3 tamper, - ZONE 1 alarm + ZONE 2 alarm + ZONE 1 alarm The following activations will NOT cause a confirmed alarm (examples). - ZONE 1 alarm + ZONE 1 alarm + ZONE 1 alarm New Menu Option Failed to Set added In system status, a new menu, called Fail to Set, will appear when an area that keypad and user has access to, has failed to set. The menu will list all areas that have failed to set. When the area is selected, the reason will be displayed. Viewing of Inhibited, Isolated Zones or Zones in Soak Test Additional functionality has been added to the keypads for bypassing zones so that when zones are bypassed, a user can press the up or down arrow to view the zones that have been bypassed. This functionality will also be available for soak test, inhibits and isolates. A new keypad soak menu option has also been added to the system status menu for both user and engineer. This menu will allow a user to view any zones on soak, but will not allow the user to un-soak or isolate the zones. Multiple Input Activations are Logged 8 Times in a Set Period The limit for multiple activations on the same input during the same SET period has been increased from one to eight. This means that if an input activates multiple times during the same SET period, the maximum number of times that it will be recorded in the LOG and reported to a central station will be eight. Note: There has been no change to the fire input so this will still only be logged and reported once. CHANGE
All

NEW
All

NEW
All

s Building Technologies Division: Security Products

Page: 4 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

Various alterations for EN50131 compliance There has been a review of alert operation in order to comply with EN50131-3:2009. This will affect prevention of setting and warning device operation prevent. Antimask in Unset will now Cause Trouble by default The event ZONE masked in the unset state will produce a trouble event by default to comply with the EN50131 standard. New default settings are: Ireland: Antimask in Unset Disabled Antimask in Set Alarm All other countries: Antimask in Unset Trouble Antimask in Set Alarm ZONE Masking Latched The ZONE Masked event is now latched. This means that if a ZONE Masked event occurs, it will remain active until restored by a level 2 user. The operation of the ZONE Masked output has changed so that the output will remain active until restored. ZONE Masking will be logged by default. The number of log entries will not exceed 8 between arming periods. For an EN50131 Grade 3 system a ZONE masked event will prevent arming so a user must force set or clear the alert in order to set the system Change to Zone Attributes for Holdup and Tamper Change to zone attributes so that tamper and hold up zones can now be inhibited. Change to Operation of Line Fault Zone Type Change to operation of line fault zone type so now follows the fault type: SIA reports Modem Fault + Zone number CID reports Telco 1 Fault + Zone number Outputs turns on fault output Activates the fault led on keypad Raises as info on keypad not alarm. Selectable User Rights for Seismic Test Before this version there was no user rights to allow a user to start a Seismic test. A user right was implemented as follows: User right is available for Standard User and Manager For Manager the option is set by default, for standard user the option is not set by default Only affects a MANUAL test (from keypad). Users without this attribute will still cause a seismic test to initiate when setting an area if that is how the panel is configured.
Page: 5 / 23

CHANGE
All

CHANGE
All

CHANGE

CHANGE
All

CHANGE
All

CHANGE
All

s Building Technologies Division: Security Products

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

Change to minimum timer for Strobe/Bells for Belgium When Region Belgium is selected the following default values have been changed in accordance to Belgium TO-15 standard: Default Grade= TO-14 Unrestricted Grade= External TO-14 Bell Strobe Unrestricted Grade= External TO-14 Bells Unrestricted 0 min =infinite (old: 15 min) 0 min =infinite (old: 15min) 0 min =infinite (old: 15 min) 0 min = infinite (old: 15 min) 3 min (old: 15 min) 3 min (old: 15 min) Minimum 0 min =infinite (old: 1 min) 0 min =infinite (no change) 0 min =infinite (old: 1 min) 0 min =infinite (no change) 0 min = infinite (old: 1 min) 0 min =infinite (no change) Maximum 999 min (old: 15 min) 999 min (no change) 999 min (old: 15 min) 999 min (no change) 999 min (old: 15 min) 999 min (no change)

CHANGE
BE

Internal Bells

Zone Alerts Display Changed on Keypad When there was a zone alert on the system which was subsequently cleared, the user could see the fault LED flashing on the Keypad. However, the menu View Alerts would only show the zone description and so the user had no way of seeing what the problem was. The user can now use a Toggle key (the * key) to view the alarm condition in the View Alerts menu. For Example, if a tamper occurred on Hall ZONE, then on entering the View Alerts menu, the user will see Hall ZONE. Upon pressing the * key, the keypad will display Zone 3 <T>. In General, the Zone <Alert Type> is one of the following: Alarm Tamper Trouble Masked =A =T = TR =M

CHANGE
All

Post alarm = PAX Random Test Call Times Change to the time that automated test calls and test SMS were being sent. SMS tests will be transmitted between 9:00am and 6:00pm. ARC test calls will be transmitted between 1:00am and 5:00am. Previously the automated test calls were always done at 2:00am which could lead to a resending of test calls when receiver was busy when many panels transmit test calls at the same time.
s Building Technologies Division: Security Products

CHANGE
All

Page: 6 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

Added Access Events Reported over EDP or to SPC Pro The following access events are now reported over EDP or to SPC Pro: Card Format Invalid Card is Void Unknown Card Incorrect Site Code Clock and data reversed EDP zone status expanded A new element has been added to the zone status LOGIC_INPUT. This is to address the issue of normally open zones reporting over EDP causing issues for external systems. Fast Format Low Battery Option Low Battery option has been added to ARC filter configuration for the Fast Format page. Change to CID code for hold up zone There has been a change to the CID code for hold up zone, the zone will now transmit CID code 376 instead of 380.

CHANGE
All

CHANGE
All

CHANGE
All

CHANGE
All

Web Page Language not latched CORRECTION All No matter what language you select on the panel, the browser is always English unless manually changed. Now the system language will be used by default. Panel Doesnt Send the Panel Unset Flag over EDP CORRECTION All If the panel is unset after an alarm activation the panel would inform SPC Com XT (or any EDP receiver) that it was part set and not unset. The panel now correctly informs SPC Com XT (or any other EDP receiver) that the panel is unset. X-Bus node reporting AC Power Failure over EDP CORRECTION All X-Bus devices didnt report node ID over EDP when AC power failed. This is now corrected. Fail to set not reported for CID CID (contact ID) change that Late to Set and Early to Set will now use CID codes 452 and 451. Fail to set will now be reported as 454. Modem Fault not reported over SIA or EDP The modem fault was not transmitted over SIA. The transmitted codes are: Event: YS + modem number Restore: YK + modem number No correct Toggling of test Channels of Redcare Modem When testing an external Redcare modem the channels being tested were not toggled correctly. This is now corrected. CORRECTION
UK

CORRECTION
All

CORRECTION
All

s Building Technologies Division: Security Products

Page: 7 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

SMS Stops working after 5 Minutes of SMS messages If the panel was send SMS messages for more than 5 minutes, SMS will no longer work until the panel is power cycled. No manual Test Call to ARC when selected from Keypad Selecting test call in the keypad ARC menu would not make a test call. This is now corrected.

CORRECTION
All

CORRECTION
All

SPC Safe Reporting Timer not Working CORRECTION All Automated Reporting after configuration change from the panel to SPC Safe (Reporting Timer) was not working. Time Locked Areas Not Unsetting A bug has been fixed where if a Financial area was "TIME LOCKED" by calendar and had "UNSET DELAY" enabled, the area would not unset after the calendar unset timer started, the area remained Fullset. Line fault zone type causing bells when full set The line fault zone type has changed so that when Fullset it will no longer activate bells and will now only activate the buzzer on the keypads when unset. CORRECTION
All

CORRECTION
All

Unset with Card Reader not possible if Part Set CORRECTION All It was not possible to unset an area from a card reader (connected to 2-door expander) if an area was part set. This is now corrected. Users reset changes Engineer PIN If users had 6 or more digits in their PINs and used the reset all users utility, the Engineer PIN defaulted to 000585. The Engineer PIN is now correctly reset to default 001111. Using pace did not update user language When using Pace the user language was set to the system language and not to the user language. This has been corrected END CORRECTION
All

CORRECTION
All

s Building Technologies Division: Security Products

Page: 8 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

SPC42xx43xx52xx53xx63xx_V3.1.0

06.09.2011

Updates since: SPC42xx43xx52xx53xx63xx_V2.1.3

Feature type
(related languages)

No storage of firmware on SPCX410 Fast Programmer This firmware cannot be stored on SPCX410 Fast Programmer with 1 MB memory due to file size. Download only via Web-Browser or SPC Pro. No direct upgrade possible for firmware versions 2.0.x or older The direct upgrade from firmware version 2.0.x (or older) to V3.x is not possible. In this case its necessary to upgrade to V2.1.x first. Note: The firmware can be to be found on product CD in the same folder as the V3.x firmware release. When upgrading older panels with new firmware not all new SPC features are supported (details see further below). SPC Pro (PC Programming Software) requirements This firmware is supported with SPCS310 SPC Pro release 3.1.0 or higher. Default PINs / Change Number of digits in PIN Following rule is strictly applied across the system. Default Engineer PIN is 1111 for 4-digit PIN (e.g in EN50131 Grade 2 systems). Increasing the number of digits will add the relevant number of zeros to the front of an existing Engineer / User PIN. As an example, Default Engineer PIN is 01111 for 5-digit PIN (e.g in EN50131 Grade 3 systems). Supported languages Supported languages in this release are English (en), German (de), Italian (it), Spanish (es), Swedish (sv), Dutch (nl), Flemish (vls), French (fr) Import of external language file New options have been added to support import of an external language file via Web Browser and Fast Programmer. The imported language can be used in the same way as the core languages available on the panel. WEB browser: New File option Import Language File to make the language available for WEB browser and Keypads. Fast Programmer: New option in Keypad Engineer menu. Note: The system supports language files with ISO code page 1250/1252. Individual assignment of language to a user New options have been added to support individual use of languages in the panel for multi-lingual applications. Previously it was only possible to apply the same language to all system users. Existing Language option "Language" to define system default language. New Language attribute "Idle Language" to display preferred language in idle state (options Use system language or last used) New System Timer "Keypad Language"(0-9999 seconds) to define
s Building Technologies Division: Security Products

IMPORTANT

GENERAL

GENERAL

GENERAL

NEW
en, de, es, it, sv, nl, vls, fr

NEW
All

NEW
All

Page: 9 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

waiting time in idle state before switching back to system default language. New User attribute Language to select language which is applied to this user. Note: For Engineer access the default language will be applied. New Financial function The installation type Financial has been added to the area options for easy configuration of typical applications used in financial segment. When this option is selected new configuration options are added to the system: New Area option "Area Type" to select area types "Standard", "ATM", "Vault" and "Advanced" to support typical use cases in financial segment with predefined area settings and timing functions. Depending on chosen financial area type, following new options are available: New Area timer "Delay Unset" (0-120 minutes) to delay unset (e.g. of an ATM). New User Right Bypass Delayed Unset to enable user to bypass Delayed Unset timer (e.g. for Cash in Transit users). New Area attribute "Interlock Group" (1-8) to enable only one area of this group to be unset (e.g. only one ATM is unset). New Area attribute "Time Locked" to lock Vault with a calendar New Area timer "Vault Access" (0-120 min) to enable Vault access only for a limited time after time locked unset. New Zone type and output type Seismic to support seismic detector testing (see separate feature description) IMPORTANT: Not all SPC panel types support the financial features. Please refer to the according datasheet of the specific panel type if financial features can be supported. IMPORTANT: KNOWN BUG: Following bug is known and will be corrected in one of the next releases: When a Financial area is "TIME LOCKED" by a calendar and "DELAY UNSET" timer is configured, the area will not unset after the calendar unset timer starts (resp. remains fullset). Digital Audio / Video alarm verification Audio trails and video images from pre-, post- and live-events can be sent via IP (over Ethernet) to CMS/ARC using the EDP protocol. This allows the CMS operator to verify and confirm an alarm in less time with a high true alarm rate. Additional options have been added to Web Browser to support the verification feature via IP (over Ethernet). New Verification option "Verification Zones" to create and configure verification zones. Maximum 1 audio device (SPCV320/321 Audio Expander or SPCK623 Comfort Keypad with Audio) and/or 1 IPs Building Technologies Division: Security Products

NEW
All

NEW
All

Page: 10 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

camera can be configured per verification zone. Maximum system capacity: SPC43xx: Max. 4 verification zones / 4 cameras / 4 audio devices SPC53xx: Max. 8 verification zones / 4 cameras / 8 audio devices SPC63xx: Max. 16 verification zones / 4 cameras / 16 audio devices New Zone option "Verification Zone" to configure the verification zone to be activated when input is triggered (supported zone types: "Alarm", "Entry-Exit", "Fire Exit", "Panic", "Hold-up" and "Seismic") Note: The verification event on Entry-Exit is triggered when the entry route starts. New Verification options Camera to configure camera settings: - IP-settings to connect to camera in same subnet. - Pre-defined settings for the Siemens cameras CCIC1410 and CFMC1315. - Configurable CGI command string to capture picture from generic cameras. - Up to 16 pre / 16 post event images (by JPEG resolution 320 x 240, max. 1 frame / sec.) per IP-camera. New Verification options Verification to configure audio settings: - Up to 60 sec. pre / 60 sec. post audio recording per audio device New System Option "Silence during Audio Verification" to switch off external bells, keypad buzzers and annunciation messages in case of post- and live event recording. New System Option "Audio Expander LED" to switch off LED on Audio Expander. LED of satellite (WAC11, WAS11) need to be configured with jumpers. Separate transmission of pre-/post events to provide operator already the pre-event information when post-event is still running. New User Right "View Video" to allow user to watch live pictures of all cameras via WEB interface New EDP receiver setting option Live Streaming to select privacy options for live streaming (Disabled / Only after Alarm event / Always). New EDP receiver setting option Verification to enable transmission of verification data to receiver. IMPORTANT: Limitations when using IP over GPRS The performance and feature set is limited when IP over GPRS is used as backup channel for verification. To activate GPRS channel the Ethernet connection must be down or disabled and the GPRS connection to EDP receiver has to be established and the GPRS IP address must be known to the EDP receiver (e.g. SPC Com XT). The pre / post event audio files and pictures can be retrieved via GPRS. The limited bandwidth of GPRS transmission must be taken into consideration (it may take up to several minutes to transmit pre event files). Live audio / Video over GPRS is not supported due to limited GPRS bandwidth. Seismic Detector Test (automatic / manual)
s Building Technologies Division: Security Products

NEW
Page: 11 / 23
release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

New options have been added to support testing of seismic detectors. Automatic seismic detector testing features: New Zone type "Seismic" to connect Seismic detectors. New Zone attribute "Automatic Sensor Test" for seismic detectors to include in manual or automatic seismic detector test. New Output type "Seismic Detector Test" to activate test vibrator of seismic detectors within an area. New System Timer "Seismic Sensor Auto test" (12-240 hrs) to define average time between random tests. New System Timer "Seismic Sensor Test Duration" (3-120 sec) to define max. waiting time for sensor after activation of test vibrator. New System Option "Seismic Test on Manual Set" to enable seismic sensor test before setting an area with seismic detectors. If area is set automatically (by calendar, key switch or input) or remotely (e.g. via EDP by SPC Com) the automatic test before setting will be skipped (only random automatic testing will be performed. If automatic seismic test fails a Trouble is reported: SIA: UT/UR (untyped trouble), CID: 150 (non burglary) Manual seismic detector testing features: A manual seismic test can only be triggered by the Engineer and User by the Keypad. A manual test is selected by Area and will test all seismic sensors in that area at the same time. All seismic sensors that fail are reported in the keypad. If a manual seismic test fails, no events are reported (only local message on keypad). IMPORTANT: Not all SPC panel types support the financial features. Please refer to the according datasheet of the specific panel type if financial features can be supported. Temporary unset of areas A new Area attribute "Unset duration" has been added to limit time (0-120 minutes) an area can be unset (e.g. an ATM). Reporting of Early/Late to Set/Unset of areas New attributes and timers for "Early to set, Early to Unset, Late to set and Late to unset have been added to the area options. This enables a report to be sent to CMS/ARC if the panel is manually Fullset/Unset before/after a scheduled Set/Unset and before/after the number of minutes (0-120 minutes) entered in the Timer field. Enhanced area auto-set options Additional options have been added respectively re-arranged in area settings for enhanced auto setting options. These options can be combined
s Building Technologies Division: Security Products

All

NEW
All

NEW
All

NEW
All

Page: 12 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

with the financial functions. Area attribute Auto Set Warning Time to define warning time 0 30 minutes before auto set. Note: The panel sets either at the scheduled time or at the time defined by the Delay Unset parameter. The first warning is displayed at the configured time before the scheduled time. New Area attribute Auto Set Delay to enable a user with enabled user right Delay Auto Set to delay Auto Setting for this area. New Area attribute Auto Set Cancel to enable a user with given user right Auto Set Delay to cancel Auto Setting for this area. New Area attribute Key Switch to enable a user to delay auto setting via key switch expander (SPCE110) by the time defined in Delay Interval. New Area timer Delay Interval to define the time [1-300 minutes] the auto setting can be delayed at once. New Area attribute Delay Counter to define the number of times [199, 0=unlimited] the auto setting can be delayed by the Delay Interval. New System Option Output Configuration to configure behavior for Auto Set output (SPC Pro: To be found under Advanced options in Advanced Output Options): New Output Configuration option "On" to permanently activate Auto Set output during warning time. New Output Configuration option "Keypad" to follow keypad beep pattern. New Output Configuration option "Progressive" to increase warning indication frequency during warning time before setting: - 20 Minutes before set: Buzzer will be activated every 30 Seconds. - 10 Minutes before set: Buzzer will be activated every 15 Seconds. - 3 Minutes before set. Buzzer will be activated every 5 Seconds If option is disabled the buzzer will be activate every minute (except last minute its every 10 seconds). New Output Configuration option "Pulse Time" (n x 100ms) to define the time the Auto Set output is active when pulsed.

All Okay entry procedure New options have been added to support All OK entry procedure. This is to enable the first employee in the morning to check the premises for any suspicious indications and inform the next employees about the result with visual indication. New Area option All OK required to enable All OK entry procedure. New Area timer "All Okay Verification Time (1-999 sec) to define the maximum time window until the "All Okay" button has to be pressed. New Zone type "All Okay" to be activated from first user (e.g. hidden
s Building Technologies Division: Security Products

NEW
All

Page: 13 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

push button) before All OK Verification Time expires. New Area attribute "All Okay event" to define the alarm type if "All Okay" entry procedure was not successfully terminated. New Output types "Entry Status" and "Warning Status" to indicate status (e.g. via LEDs) to other users after first user has entered the premises. IMPORTANT: This feature shall only be used for areas which are ALWAYS manually unset (unset by calendar or remotely will also require ALL OK button pressed). Additional linking options for areas Additional options have been added to the area settings to prevent setting / unsetting of linked areas: Prevent Fullset: Prevent this area from Fullset if any linked area is not Fullset Prevent Fullset All: Prevent linked areas from Fullset if this area is not Fullset. Prevent Unset: Prevent this area from Unset if any linked area is Fullset Prevent Unset All Prevent linked areas from Unset if this area is Fullset. Dual PIN for Set/Unset New Area attribute Dual PIN has been added. If this option is enabled, two PINs are required to Set or Unset the area with the keypad. Both PINs must belong to users who have the required user right for the operation (Setting or Unsetting). If the second PIN is not entered within 30 seconds, or it is wrong, then the area cannot be Set or Unset. NEW
All

NEW
All

Exit Route through Multiple Areas New Keypad attribute Delay Fullset has been added. If enabled, the exit timers are used across all areas the keypad is assigned to respectively the user has the user rights for. Previously (or if attribute is disabled) only the entry/exit timer of the particular area is running in which the keypad is located.

NEW
All

Door Interlock to prevent other doors from opening New Door attribute Interlock has been added. This prevents remaining doors from opening if one of the doors in the same Door Group is already open (e.g. people separation entries in banks). Reader locking after PIN / Card Tamper When presenting of an invalid card or three invalid PINs a PIN tamper on a reader will be generated and causes that reader to be locked out for 2 minutes. This is only if PIN or card are invalid and not if they dont have access. Set / Unset with Prefix for Card Readers with PIN pad
s Building Technologies Division: Security Products

NEW
All

CHANGE
All

NEW
release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

Page: 14 / 23

A new Door attribute Setting Prefix has been added to set/unset an area with a card reader using a prefix * resp. A or # resp. B. If enabled the area will be set (if reader is enabled and user rights are given) when keys */A or #/B are pressed before showing the card. This will work on readers with PIN pads which send a 10 for */A and 11 for #/B (e.g.Siemens PP500). Previously the set/unset of an area with a reader was only possible by presenting the card twice within a few seconds (double batching). Note: Using Setting Prefix is superseding the double batching procedure to set/unset an area. Different door modes depending on area setting state New options have been added to change security level an area can be accessed via door reader depending on the setting state of the area. E.g. during day (normally the area is unset) the users can present the card to open the door, but during night (area is set) the door requires Card + Pin to unset area / to open the door. New System Options "Door Mode Set" and "Door Mode Unset" to define security level to open the door. - Default: Will act as defined at individual doors - Card + PIN: Will require Card + Pin - Card or Pin: Will require Card or Pin Note: The Card + PIN " or " Card or PIN " are superseding system wide the individual door setting options "Card + PIN", "Pin only", "PIN or Card", "Pin to Exit", if area is set resp. unset. New system option "Override Reader Profile" to indicate required actions from or confirmations to the user via the reader LEDs: - No LED indication in idle state (independent if area is set or unset) - Fast flashing green LED when system expects the 2nd identification - If the user tries to set via reader the RED Led is permanently on for 10 sec. if area could be successfully set resp. RED Led is flashing for 10sec. if area could not be set for any reason. Note: This setting supersedes individual door setting options LED Reader Profiles. The status indication is optimized for readers with 2 individually controllable LEDs (e.g. Siemens PP500).

All

NEW
All

Additional Card Reader Profiles for HID Readers Additional Card Reader profiles Profile 3 [PIN/Site 0] and Profile 4 [PIN/Site 0] have been added to the door expander options. This is to support the PIN pad option of HID readers that send the PIN to the panel as a special card read with predefined site code. Note: To support this feature the 2-door expander in SPCA210, SPCP432 or SPCP433 requires firmware version 1.6 or higher New Zone attributes Unset Local and Silent New Zone attributes have been added to the zone options: Unset Local: When this attribute is set, an alarm generated by the zone opening when the area is Fullset or Partset will be reported in
s Building Technologies Division: Security Products

NEW
All

NEW
All

Page: 15 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

the usual way. However, if the area is unset there will be only a local alarm i.e. keypad buzzer, LED flash and zone display. This attribute is only applicable to Alarm, Fire and Seismic zones. If the Silent attribute is set then there will be no audible or visual indications of the Alarm. The alarm activation will be sent to the Receiver station. If the system is unset then a warning message is shown on the display. New options for Keyarm zone type New Zone attributes have been added to the Keyarm zone type: Open Only: If this attribute is set then the setting state of the area will toggle every time this zone is activated. If this attribute is disabled the area will set when zone is activated and unset when zone is deactivated. Fullset Enable: If this attribute is set then zone activation will only Fullset the system/area. Unset will not be possible. This is used if the user should have the ability to only FULLSET the system from a Keyarm zone and the unsetting of an area shall be prevented from a key arm zone. Unset Enable: If set then zone activation will only Unset the system/area. Fullset will not be possible. This is used if the user should have the ability to only UNSET the system from a Keyarm zone and the setting of area shall be prevented from a Keyarm zone. New Output types for system supervision New Output types have been added to signal additional system status: Modem 1 Line Fault: This output activates when there is a line fault on the primary modem. Modem 1 Failure: This output activates when the primary modem fails. Modem 2 Line Fault: This output activates when there is a line fault on the secondary modem. Modem 2 Failure: This output activates when the secondary modem fails. Battery Low: This output activates when the battery is low. Strobe infinite time New value 0 allowed in System Timer option External Bell Strobe to activate strobe permanently. Previously the strobe could only be activated during a finite time window. New output type Local Alarm A new Output type Local Alarm has been added to the output options. This output activates on a local intrusion alarm of zone types Alarm, Entry/Exit and Seismic until the a transmission takes place (if no transmission takes place the output remains on until alarm restore). Configuration of Latch Output CHANGE
All

NEW
All

NEW
All

NEW
All

NEW

s Building Technologies Division: Security Products

Page: 16 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

New System Option Output Configuration (SPC Pro: To be found under Advanced options in Advanced Output Options) to adapt behavior of the Latch output (used to reset latching sensors as smoke or inertia detectors) to various scenarios (multiple selections possible): New Output Configuration option "Entry Time" to turn Latch output on at end of exit time and off at beginning of entry time. New Output Configuration option "Fire Exit" to turn Latch output on if any Fire X zones are active. New Output Configuration option "Unset" to turn Latch output on if user Unsets systems, momentary. New Output Configuration option "Alarm Reset to turn Latch output on when an alarm is reset , momentary New Output Configuration option "Resetting Alarm to turn Latch output on during setting procedure if glass-break /smoke detectors are open and not in alarm. New Output Configuration option "Engineer Exit" to turn Latch output when engineer leaves engineer mode, momentary. Configurable Antimask behaviour New System Options have been added to select the event type reported resulting from antimask detection depending on area setting state. "Antimask Set": Select reported event type if area is set (alarm, tamper, trouble, disabled). "Antimask Unset": Select reported event type if area is unset (alarm, tamper, trouble, disabled). Note: The option can only be configured when the panel is in Unrestricted mode. In Grade 2 or 3 mode, the type of event reported is in accordance with the standards for the selected region: Ireland: Alarm on Set / Disabled on Unset All other regions: Alarm on Set / Tamper on Unset Wireless Timers moved Setting options for two wireless timers (Device Lost and Prevent Setting) was moved from the System Timer options to the Wireless Setting options. New Cause & Effect area triggers Delay Auto Set and Clear Alarms Additional Area trigger options have been added to the area option. Delay Autoset: The automatic setting of an area can be delayed by the Delay Interval time with a Cause&Effect trigger. Clear Alarm: The alarms of an area can be restored with a Cause&Effect trigger. WPA (Wireless Panic Alarm) support The IPAW8-10 provides additional security and comfort functions to people carrying the Wireless Panic Alarm. The number of WPAs (IPAW8-10) which can be addressed depends on
s Building Technologies Division: Security Products

All

NEW
All

CHANGE
All

NEW
All

NEW
All

Page: 17 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

panel type: SPC4xxx: max. 32 WPAs SPC5xxx: max. 128 WPAs SPC6xxx: max. 128 WPAs New options have been added to support the WPA device IPAW8-10. New Wireless section "WPA" to configure the IPAW8-10. New WPA attribute "Function Buttons to define function per button (red, green, yellow) and the combination of it. Configurable functions are Panic, Holdup, Suspicion, RF Output. New Trigger options "WPA Function" to use pressing of WPA button (or a combination of it) as a trigger for Cause & Effect. New WPA attribute "Transmitter ID" as unique reference for a specific WPA (printed on IPAW8 -10 housing) to address the device to the system without learning it in via keypad. New WPA attribute "Supervise" to enable supervision of device from panel (IPAW8-10 must be enabled to transmit supervision signals). New WPA attribute "Test" to enable test function. New Wireless timer option "WPA Test Schedule" (0-365 days) to define number of days between tests. New User Right "WPA test" to enable user to perform a WPA test anytime to check correct functioning of the device. All three buttons on WPA have to be pressed simultaneously. Note: The IPAW8-10 is compatible to following SiWay receivers: - SPCW111/112 with revision 5.0 or higher - SPCW110 with revision 5.0 or higher - SPCW130 with revision 5.0 or higher The IPAW8-10 is not supported via SPCK422 Firmware of wireless receivers (SPCW110 / SPCW111 / SPCW112 / SPCW130) cannot be upgraded.

RF unset during Entry time New Area option FOB Unset Entry has been added. If enabled, unset of area with wireless remote control (FOB) is only allowed when entry timer is running. If disabled the area can anytime be unset. Dedicated RF Outputs New options have been added to control a dedicated output by a wireless remote control without using cause & effect programming. New Output type "RF Output" to be activated by RF remote control. New User Right "RF Control" to allow user to control RF outputs New Area attribute "RF Output Time" (seconds) to define how long "RF Output" is activated (0=toggle).
s Building Technologies Division: Security Products

NEW
All

NEW
All

Page: 18 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

Activate Mapping Gate output by user New options have been added to enable a user to switch on/off mapping gate outputs via WEB browser. New User Right MG output control: If enabled, the end user is allowed to switch unprotected mapping gates when logged on to the Web Server. New Mapping Gate option Protected in Mapping Gate options: If enabled, the user CANNOT switch this mapping gate, even if the user right is given to do so. Alarm Abort Transmission after valid PIN New system timer Alarm Abort has been added. This defines the time window (0 999 seconds) after a reported alarm in which an alarm abort message can be reported after valid user PIN is entered. Restore state after power down Added support for storing state variables in flash, to allow panel to restore its state after a complete power down. Additional SMS event transmission / Time Stamp New functions have been added for SMS transmission: The attribute Others has been added to transmit the remaining events (System Restart, User PIN Tamper, Time Change, Full Engineer Mode enabled/disabled) which cannot be selected by other SMS event filters. Time stamp of event is also transmitted. Previously no time stamp was transmitted with the event. Automatic Padding of Contact ID account numbers The Contact ID account numbers are automatically padded : If number is less than 4 digits it will be padded to 4 digits If number is greater than 4 digits it will be padded to 6 digits Previously the Contact ID account numbers were not automatically padded. SIA Code ZS and UA changed to ZX and UT SIA code ZX is used instead of ZS for zone short, as ZS was already defined in the SIA standard for another purpose. This applies only to EDP. SIA code UT is used instead of UA for Trouble messages. Extended event filter settings Additional event filters options have been added to the event filter options: For CID, SIA and EDP protocol: Early/Late: If enabled, early and late openings and closings of areas (as defined in area options) are reported. Alarm Abort: If enabled, alarm abort messages are reported.

NEW
All

NEW
All

CHANGE
All

NEW
All

CHANGE
All

CHANGE
All

NEW
All

s Building Technologies Division: Security Products

Page: 19 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

For EDP protocol: Zone States: If enabled, all zone input state changes are reported independent of area setting state. Network: IP Network Polling Up/Down events are reported. Others (non standard): Non supported SIA codes used with SPC COM XT including Camera Online/Offline events are reported (CU: Camera online / CV: Camera offline). Other EDP Protocol enhancements The EDP protocol has been enhanced in particular aspects to support additional market needs. Overview: Support of audio / video verification features through EDP Time stamp of panel added to reported events. Reporting of physical zone states Reading Access Log Support of TCP/IP: New option Network Protocol in EDP receiver settings in WEB interface to configure UDP or TCP connection to receiver. Previously only UDP was supported. Note: This feature is only supported with SPCN310 GSM module with Wismo GSM chip fulfilling all the characteristics below: - Wismo chip fitted (visible on PCB), - PCB Revision E-PC142011 IE; Rev 1.1 PCB - Hardware Build Revision (seen on packaging label): A - Hardware Revision (seen on user Interface): 2 (Note: Rev 1.x with Enfora GSM Chip dont support this feature) - Firmware Release: V3.x Full EDP protocol description is available on request from product management. EDP receivers as poll master must send poll message first After a communication channel is opened by the EDP receiver, the poll master must send a poll message before any other message. With version 2.2.x and lower it was not necessary to send a poll message to get a response from the SPC control panel. Limited time synchronization request via EDP New System Timer Time Sync Limit has been added. If this option is enabled a time synchronization command via EDP is only accepted by the panel if the new time and actual time of control panel are outside of the defined time window (0-999 seconds). Otherwise, the command will be ignored without any time correction, confirmation message or log entry. Previously all time set commands coming via EDP have been accepted by the panel. Separate firmware file for peripherals / upgrade of modems The firmware of panel and peripherals (expanders, keypads, door controllers and modems) are delivered as separate files with extension .fw for panel and .pfw for peripherals (tb found on product CD in the same
s Building Technologies Division: Security Products

NEW
All

CHANGE
All

NEW
All

NEW
All

Page: 20 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

folder as panel firmware) Its now possible to upgrade also firmware of GSM and PSTN modems. This feature is supported for following modems: SPCN310 with Wismo GSM chip: Upgradable modems have to fulfill all of the characteristics below: - Wismo chip fitted (visible on PCB), - PCB Revision E-PC142011 IE; Rev 1.1 PCB - Hardware Build Revision (seen on packaging label): A - Hardware Revision (seen on user Interface): 2 (Note: Rev 1.x with Enfora GSM Chip cannot be upgraded) - Firmware Release: V3.x SPCN110: Upgradable modems have to fulfill all of the characteristics below: - PCB Revision E-PC137421 IE; Rev. 2.1 PCB, and - Hardware Build Revision (seen on packaging Label): A1 - Hardware Revision (seen on user Interface): 1 - Firmware Release 2.x Previously the firmware of peripherals and panel was packed in the same file. Update of GSM / PSTN modules was not possible. Note: Firmware of wireless receiver modules (SPCW110 / SPCW111 / SPCW112 / SPCW130 cannot be upgraded. Engineer Exit A new System Option Engineer Exit has been added. If enabled the Engineer can exit from Full Engineer even if faults are present. The Previously it was not possible to leave the Full Engineer mode without isolating or repairing the faults. View Alerts without clearing New Keypad Menu option View Alerts have been added to allow users (standard or manager) to view alerts without clearing them. Key switch Function The programming options for Key Switch Expander SPCE110 have been extended with programmable functions for each key switch position to align with Indication Expander SPCE120. Previously it was only possible to use key switch positions as trigger input for cause & effects. NEW
All

NEW
All

NEW
All

Retriggering of Panic and Duress alarms New System Options have been added to retrigger Duress and Panic alarms without restoring the alarm. Triggering/Retriggering of Panic or Duress will activate the according output types and activate the transmission. "Retrigger Duress" to enable retriggering of Duress alarms without restoring the alarm. "Retrigger Panic" to enable retriggering of Panic alarms without restoring the alarm. Previously the Duress and Panic alarms were only triggered once and had to be restored before they could be triggered again.
s Building Technologies Division: Security Products

NEW
All

Page: 21 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

Extended Policy options Extended System Options (WEB interface only) have been added to define system behavior (Policy) for specific aspects. These options are only available when Standards are set to Unrestricted. Available policies are (new and existing). System Alert Policy to configure processing of system alerts Zone Alarm Policy to configure processing of zone alarms. Zone Tamper Policy to configure processing of zone tampers. Keypad Display Policy to configure displayed event texts on keypad. Keypad LED Policy to configure displayed LEDs on keypad. System Policy to configure general system behavior. Timing Policy to view settings of system timers. These options are normally used to tune the system to pass local approvals. SWISSI standard requirement New options have been added to comply with the Swiss approval standard: New Regional setting option to comply with Swiss CAT1/CAT2 approval requirements. New System Option Alarm on Exit. If enabled, an alarm is raised if any entry/exit zone is still open when the exit timer expires. Otherwise the system will fail to set if any entry/exit zone is still open. Note: For all other regions than Switzerland this option is disabled and only available when Unrestricted grade is selected as setting is not in accordance with EN50131. New System Option Alert Forbid Set: If set a user cannot set an area with pending alerts or system alerts.. Note: For all other regions than Switzerland this option is disabled and only available when Unrestricted grade is selected User keypad lockout times for the Swiss standard for CAT1/CAT2 are the same as applied to EN Grade 3.

NEW
All

NEW
All

Alterations for EN50131 compliance The following functional changes were made due to change of interpretation to comply with EN50131-3:2009 when Grade 2 or 3 is selected. X-BUS expander and keypad communication loss events should be processed as tamper and not fault. Users are not allowed to restore faults in EN5031 Grade 3 configurations. Prevent from setting if Alarm Transmission fault Prevent from setting if Warning Device Fault (bell tamper) Prevent from setting if ATS (Alarm Transmission System) faults (e.g.
s Building Technologies Division: Security Products

CHANGE
All

Page: 22 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc

Communication Fault, Modem Fault, Line Fault) Connection to SPC control panel via USB port sometimes doesnt work When using the USB port for local connection of PC/Laptop to SPC control panel with PCB revision 1.4 or lower, the connection couldnt be established every time, even the SPC driver recognized that a panel was connected. This behavior is corrected with this version. CORRECTION
All

s Building Technologies Division: Security Products

Page: 23 / 23

release_note_spc42xx43xx52xx53xx63xx_v3.2. 2_en.doc