DRY BATHS
Features: Applications for incubating DNA specimens, cross matching and screens in blood bank, incubating melted agar, Enzyme assays, digestions, Residue tests for milk & also great for serology, hematology, pathology and biochemistry etc. Choose from various heating blocks that accommodate test tubes, cuvettes, and micro centrifuge tubes. Each block has a well to accommodate a removable thermometer, which monitors temperature of blocks. When solid block (no holes) is used, it can function as HOT PLATE.
Model Overall dimension (mm) Net weight (Not include blocks) Temp. setting Temp. reading Temp. range Temp. accuracy Uniformity (at 37C) Temp. sensor Temp. control Overheat alarm Heating element Timer Insulation DBD-003
370x245x135 3.9kg Digital (3-digit) Digital LED Ambient to 99.9C 0.1C 0.2C PT-100 PID Yes 450W Digital 99hr59min No
DBD-003E
290x290x110 6.0kg Digital (3-digit) Digital LED Ambient to 150C 0.1C 0.2C K-Type PID Yes 450W Digital 99hr59min Yes
DBA-001
210x235x115 2.1kg Analog thermometer 25-105C 0.2C 0.5C *NTC PID No 200W No No
DBA-001
DBD-003
DBD-003 & DBD-003E Activate auto-off function to automatically shut out heater at the end of timed cycle. Digital temperature display for actual temperature PV and setting Sv. Timer start working when the preset temperature has been stabilized ensures an accurate incubation effect. When complete the heat cycling, the timer will alarm and display END. Memory stores the set temperature and time of previous operation, use these set points to repeat the new operation and save time, or preset your new DBD-003E desired set points. DB-006E-150 features double wall construction with insulator by berglass for durability and good heat retention. Maximum temperature is designed up to 150C capable of functioning more applications. Safety devices: Over temperature alarm; Heating failure alarm; Double overheating protection.
Number 302-1-111101 302-1-111112 302-1-111113 302-1-111114 302-1-111115 302-1-111116 302-1-111117 302-1-111118 302-1-111119 302-1-1111110 302-1-111111 Block size Tube size
6mm 10mm 12 or 13mm 15 or 16mm 18mm 20mm 25mm 1.5ml Eppendorf 0.5ml Eppendorf 25+12+6mm or your request
Openings No. /
30/6.5mm 20/10.5mm 20/13.5mm 12/16.6mm 12/18.6mm 12/20.7mm 6/25.7mm 20 20 3+5+6 holes
Application: Solid anodized aluminium blocks resist the hardest environments and provide maximum heat retention. All blocks include thermometer well for easily measuring block temperature.
77
DRY BATHS
DBD-001
DBD-002
Model Display Heating power Unit dimension (WxLxH) Controller Heating chamber Temperature control range Temperature increment Temperature uniformity in working area at 37C Temperature accuracy in working area at 37C Temperature calibration Timer Safety device Operating temperature Special feature Block material Block type Data log Weight Rated voltage
DBD-001
LED Display 125W 200x290x80 mm
DBD-002
200W
Digital microprocessor controller Molded aluminum alloy chamber 5C Above ambient to 150C 0.1C 0.2C 0.2C Yes 1~999 mins, continuous Leakage proof for heating chamber, Over temperature protection, SSR failure detection Ambient to 40C Used as water bath incubator Aluminum alloy Standard and customized type are available RS232 approx. 2.6kg 110V or 220V selectable approx. 2.8kg
78
DRY BATHS
Specications:
Block material Dimensions (mm) Block lifter well Thermometer well
Aluminum alloy W79xL104xH50 Yes Yes (except microplate blocks)
300-1-111108: Well size 13mm,20 wells 300-1-111102: For Microplate;Titerplate (Dual Block unit only)
300-1-111109: For 15ml centrifuge tube, 12 wells 300-1-111103: For 96 wells Deep Microplate or PCR plate (for Single Block unit only)
300-1-111104: For 96 wells Deep Microplate or PCR plate (for Dual Block unit only)
300-1-111111: Well size 25mm, 6 wells 300-1-111105: For 0.2ml tube, 64 wells (or 0.2ml PCR Strip tbe for 8 weirs x 8)
79
DRY BATHS
DBC-001, Cool-Heater Dry Bath Incubator
Cool-Hotter Dry Bath Incubator is available with different temperature performance, along with a competitive range of interchangeable block. It is designed for a variety of applications including ligation, storage, restriction digests, denaturing DNA, BUN, melting agar, coagulation studies, hybridization and Hot Start thermo-cycled reaction. The fully programmability contains Constant Operation, Programmable Mode, and Annealing Mode. A 2.6" LCD screen, showing all the running / setting conditions. Microprocessor controller offers easy temperature selection, rapid heat up and cooling down with an excellent stability. The temperature can be set in 0.1C increments from -10C to 100C.Optional Function Control software is available for the control & real time data recording through a PC for specified user requirement. Features: Microprocessor control with digital performance for precise, accurate control. Wide temperature control range & great temperature controlled performance. Rapid temperature increasing rate. LCD screen shows all the parameters during run. User temp. calibration. Used as a water bath. Function Control software available.
DBC-001
Model Chamber dimensions (mm) Display Heating power Unit dimension (mm) Controller Heating chamber Temperature control range Temperature increment Temp. uniformity in working area at 37C Temp. accuracy in working area at 37C Temperature calibration Operation mode Safety device Operating temperature Special feature Block material Block type Data log Weight Rated voltage DBC-001
W125xL90xH50 2.6 LED 400W W200xL295xH140 Digital microprocessor controller Water-proof aluminum
-10C~100C In the environment of 25C 0.1C 0.2C 0.2C Yes Constant operation: constant temperature (-10C~100C), Timer: 1~9999 mins, Program opertion: 1~4 steps and up to 9 cycles, Timer: 1~9999 mins, Annealing program Leakage proof for heating chamber Ambient to 40C Used as water bath incubator Aluminum alloy Standard and customized type are available RS232 approx. 8kg 110V or 220V selectable
80
DRY BATHS
Model Block material Dimensions (mm) Block lifter well Thermometer well 300-1-11120x
Aluminum alloy W90xL127xH50 Yes Yes (except microplate blocks)
300-1-111202: For 96 wells Deep Microplate or PCR plate 300-1-111207: Well size 20mm,15 wells
300-1-111209: For 50ml centrifuge tube,6 wells 300-1-111205: Well size 13mm,30 wells
81
DRY BATHS
Gas Distribution
DBG-002
Parameter
6mm 7mm 10mm 12mm 13mm 15mm 15mm 16mm 16mm 19mm 19mm 20mm 26mm 28mm 40mm 0.5ml 1.5ml 2.0ml
Capacity
49 49 25 25 25 12 16 12 16 12 16 9 9 4 4 49 25 25
Dimension (mm)
96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49 96x96x49
DBD-004
Blocks
Type Temp. control range Homogeneity control discrepancy Display Temp. control discrepancy O @40~100 C Temp. control discrepancy O @100~150 C Display accuracy Heating time 40~150 C Standard blocks Nitrogen consuption Dimension (mm) Needles length
O
DBG-002
RT.+5 C~150 C 1min~99h59min 0.3 C 0.5 C 1 C 0.1 C 30min 2 0-10L/min L280xW240xH110 150mm
O O O O O O
DBD-004
RT.+5 C~120 C 1min~99h59min 0.3 C 0.5 C 1 C 0.1 C 30min 4 L380xW240xH110
O O O O O O
82
COD ThermoReactor
DRY BATHS
For The Digestion Of: COD (150C) TOC (120C) Total chrominum (100C) Total nitrogen (100C) Total phosphate (100C)
DBR-001
Chemical digestion of the samples is a prerequisite for, among other tests, determination of COD, TOC, total phosphate and total nitrogen. The required temperature and reaction time are programmed using the membrane keypad on the front of the reactor. When digestion is complete, the reactor automatically switches off and sounds an alarm. DBR-001 COD reactor is designed to meet USEPA 410.4 method. It can be used to digest closed I micro reux COD vial and other samples which diameter is 16mm. Further, it is safer and easier than traditional open macro reux method. Unique COD program let DBR-001 to be a truly automatic reactor. When the reactor is powered on, just click the start/stop button, then it starts to heat to 150C and keep for 2 hours then stop heating with a audio alarm. Samples are ready to be measured by colorimeter when they cool down. DBR-001 COD reactor is compatible with any COD detectors which use 16mm COD vials. In additional to COD program, DBR-001 is a microprocessor controlled block heater, with temperature range from 60C to 200C and timer from 0 to 999 minutes or continuous operation, and 3 extra self-made heating programs can be stored.
Model Read out Timer Accuracy Temperature Safety Block capacity Structure Power Dimensions Weight DBR-001 COD REACTOR
4 Digital LED of set temperature, set time, process temperature, residual time display 1~999 minutes with audible alarm and automatic shut off or contonuous operation 2C (at 150C) Fixed 150C (COD program) 60C~200C, adjustable
Hot top indicator (ashing when block temperature is over 70C), Automatic shut off when block temperature is over 210C)
25 of 16mm sample vials, Option block(with 8x20mm and 6x25mm vial holes) is available Housing: stainless steel with power paint coating, Block: Anodized aluminum AC110 or AC220V, 50/60Hz, 220Watt W18.9xH11.6xD31.5mm Net 4.5kg Gross 6.1kg
83
DRY BATHS
Shakers
Features: Clear, easy to use LCD display. Soft touch key pads. Small footprint. Accurately control and display time, temperature and speed. Over-heating protection device ensures safety & reliability. Audible signal to indicate end of run after program completion. Temperature can be calibrated to meet user's needs. Low noise working even under the speed of 1,500rpm. Conforms to CE safety standards.
Model Temp. setting range Temp. control range Timing range Mixing speed Mixing orbit Temp. control accuracy Display accuracy Heating time (from 20 C to 100 C)
O O
DBS-001
5 C ~100 C
O O O O
DBSC-001
0OC ~ 100OC 0 C~100 C ambient temp.20OC 4OC~100OC ambient temp.25OC 10OC~100OC ambient temp.30OC 1 min ~ 99h59min 200 rpm ~ 1500 rpm 2 mm 0.3OC 0.1OC 15 min 30 min (from RT. to RT.-20OC) 15 min (from 100OC to 20OC) L300xW220xH170 8.5 kg
1500 1500 1500 1500 1500 1200 750 750 1500 1500
100OC 100 C
O
100OC 100 C
O O
100 C
84