UL:E203489
Input DC48V
Output AC100V
Stand-alone operationType S
Features
1High Efciency
86.6% (maximum) high efciency. It helps to conserve energy and reduce power charges.
Ease of connection.
Transfer signal
DC input
Filter
DC/DC inverter
Filter
DC input
Filter
DC/DC inverter
Filter
DC input
Filter
DC/DC inverter
Filter
AC output
Up to 6 inverter units
Inverter Unit
DC input
Filter
DC/DC inverter
Filter
AC output
Up to 6 inverter units
ON/OFF switch
AC input connector
IEC-60320-C14
Front
Simulated fault signal dip switch (for testing) Bypass/power receiving conrmation LED Overload alarm LED Status display LCD Display selection button
Rear
Model No. PD-D11AB16 Serial port for factory used only. (D-Sub 9-pin, male) AC output terminal block AC input terminal block DC input terminal block
Transfer signal terminal block Ground connection terminal DC input AC input terminal block terminal block
The photos show a unit with bypass circuit. An AC input connector and AC input terminal block are not present for inverters with no bypass circuit.
The inverter units are products for parallel operation.
Specication
Inverter Unit
Item Model No. Rating capacity Bypass circuit Rating Cooling system Life of device Acoustic noise Environment AC Input Standard or Performance D11A102B011 D11A102B011US D11A102B001 1kVA(1kW)
Notes D11A102B001US Parallel operationDC/AC inverter Apparent power and active power
DC Output
Continuous Forced Air 15years 55dBMax. 5 to 40 5 to 85 Rated Voltage 48 Variation Range 40.5V to 57V Max. Input Currency 29A Input Feedback Noise 2mV Number of phase / wire Single-phase / 2 wire Voltage 100V/120V 2% Voltage regulation Frequency 50 60Hz 0.5%(1% at parallel operation) Frequency Regulation Distortion factor of voltage waveform 8 Max. Transit Voltage Variation Rated voltage 10% Response time 100Max. Load Power Factor 1 105 100V/120V 100V15% 120V15% 12.5A 10.4A 20A E203489 E203489 UL /CE UL /CE VCCI Class-AIEC62040-2: 2005 CISPR22: 2005 Class-A FCC Part 15 sub B Class A CISPR24: 1997/A1: 2001/A2: 2002 IEC62040-2: 2005
1 meter (39.4 inch) in height at the front of the unit, A characteristic A short time0 to 50 (72 hours continuation/Annual less than 15 days) A short time5 to 90 (72 hours continuation/Annual less than 15 days)
During rated output Evaluated value (at rated input and output with a resistance load) Sine waveDependent on the DIP switch setting1 Dependent on the DIP switch setting 2 During rated output 0100% load variation Variation range 0.7 (lag) to 1.0Load power factor should not exceed 1 kVA at 0.7 (lag). Sine waveDependent on the DIP switch setting
AC Input
During rated output During rated output UL 60950-1 , IEC 60950-1: 2005 2nd Edition
1: When you change the DIP switch settings, be sure to do so before the DC power is received. Even if you change the settings after the DC power is received, the changes will not become effective. 2: When the AC input power is received, the inverter output performs synchronization operation in the frequency variation range of 5% of the AC input so the frequency regulation is 5% of the rated frequency
Model numbers of inverter units with stand-alone operation cabinet D11A102B011S (For stand-alone unit with bypass circuit)D11A102B011SUS (For stand-alone unit with bypass circuit/UL certied unit) D11A102B001S (For stand-alone unit with no bypass circuit)D11A102B001SUS (For stand-alone unit with no bypass circuit/UL certied unit) Two service receptacles (NEMA5-15R)* equip as a standard (on the rear of the unit), and AC cable (with NEMA5-15P plug) equip as a standard (for standalone unit with bypass circuit only) Other specications are the same as those of the above inverter unit, except that the input circuit protector for bypass input is 15 A.
PD-D11AB16 PD-D11AB16US
Number of inverter units Device configuration N-unit configuration N+1-unit configuration N-unit configuration N+1-unit configuration N-unit configuration N+1-unit configuration N-unit configuration N+1-unit configuration N-unit configuration N+1-unit configuration DC Input Nominal voltage Voltage range to Rated input current Maximum input current Nominal voltage AC Input 100V or 120V Voltage range 85V to 115V or 102V to138V Maximum input current AC Output It dependent on the device setting Nominal voltage It dependent on the inverter unit Voltage range or to to Rated output current Rated output
Number of inverter units Device configuration N-unit configuration N+1-unit configuration N-unit configuration N+1-unit configuration N-unit configuration N+1-unit configuration N-unit configuration N+1-unit configuration N-unit configuration N+1-unit configuration Nominal voltage DC Input Voltage range to Rated input current Maximum input current It dependent on the device setting Nominal voltage AC Input It dependent on the inverter unit Voltage range or to to Rated output current Rated output NoteThe cabinet can be used without connecting to a commercial power source or AC power supply. In such a case, the unit operates at a frequency preset in the inverter. When connecting the cabinet to an AC power supply, a 3.5mA per unit of leakage current will occur. In parallel operation, total leakage current must be multiplied by the number of connected units, so please pay attention to the breaking current for the breaker in the distribution board.
Dimensions
Inverter with Stand-Alone Operation Cabinet
Model No. D11A102B011S
sizemm
sizemm
M4
M5
600 430
600
AWG126
AWG146
SANUPS
D11A
SANUPS
D11A
31.75
31.75
43.5
465 480
465 480
When these brackets are used to x the inverter unit in the rack, special rack support rails are not required.
23
23
38
43.5
430
450
450
18
M6
M8
23
18
M6
M8
23
410
440
440
88.9 75.9
88.9 75.9
465 480
177
410
465 480
Inverter Unit
10
sizemm
AWG124
M8
23
18
M6
M8
23
410
340.6
38
480 465
440
43.5
88.9 75.9
12.6 310.5
31 50 44
319
120.4
465 480
The dimensions show a unit with bypass circuit. An AC input connector and AC input terminal block are not present for inverters with no bypass circuit.
76.1
12.6 264.8
38
Eco Products
Sanyo Denki's ECO PRODUCTS are designed with the concept of lessening impact on the environment in the process from product development to waste.The product units and packaging materials are designed for reduced environmental impact.We have established our own assessment criteria on the environmental impacts applicable to all processes,ranging from design to manufacture.Those products that satisfy the criteria are accredited as ECO PRODUCTS.
http://www.sanyodenki.com
1-15-1, Kita-Otsuka, Toshima-ku, Tokyo 170-8451, Japan 468 Amapola Avenue Torrance, CA 90501 U.S.A. P .A. Paris Nord II, 48 Alle des Erables-VILLEPINTE, BP .57286, F-95958 ROISSY CDG Cedex, France Frankfurter Strasse 63-69, 65760 Eschborn, Germany Phone: +81 3 3917 5157
Rm2108-2109, Bldg A, Far East International Plaza, No.319, Xianxia Rd., Shanghai, 200051, China
Room 1208, 12F , No.96 Chung Shan N, Rd., Sec.2, Taipei 104, Taiwan, R.O.C.
Room 2305, 23/F , South Tower, Concordia Plaza, 1 Science Museum Rd., TST East, Kowloon, Hong Kong
The names of companies and/or their products specied in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. *Remarks : Specications Are SubjectTo Change Without Notice. CATALOG No.953-1 10.9