N304
N308
T302
T304
T305
T307
T308
3 3 3
3 3 3
1 1 1
UCONNMODETIMER
T309
5 5 5
N312
N313
N315
T312
T313
T314
T315
T316
6 6 6
D1 D1 D1
10 10 10
D0 D0 D0
D0 D0 D0
D1 D1 D1
T381
D1 D1 D1
N381
T323
MML_RNCID
CHANNELRETRYTIMERLEN
CHANNELRETRYHOTIMERLEN
RABMODIFYTIMERLEN
ZERORATEUPFAILTORELTIMERLEN
MML_RNCID
MML_RNCID
3 3 3
6 6 6
D1 D1 D1
1 2 3
UIDLEMODETIMER
1 3 1 2 1 3
UIUTIMERANDNUM
CNOPINDEX
0 0 0 0 0 0
CNID
N300
N312
T300
T312
2 2 2 2 2 2
1 1 2 2 3 3
20 20 20
UPSINACTTIMER
PSINACTTMRFORCON
STATEINDTMR
RSTRSNDNUM
MML_RNCID
RAFCTMR
RATCTMR
IGORTMR
INTRTMR
UPSINACTTIMER 20 20 20
PROTECTTMRFORCON
20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
PSINACTTMRFORSTR
PROTECTTMRFORSTR
PSINACTTMRFORINT
PROTECTTMRFORINT
PSINACTTMRFORBAC
PROTECTTMRFORBAC
PSINACTTMRFORIMSSIG
PROTECTTMRFORIMSSIG
PSINACTTMRFORPREFSTDRM
PSINACTTMRFORFSTDRMDCH
PSINACTTMRFORFSTDRMFACH
MML_RNCID
USTATETIMER
RRCUERSPTMR
RRCIURELCMDTMR
RRCRELRETRANTMR
RRCPAINGTYPE1TMR
RRCINITDTTMR
1000 1000 1000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000
RRCRLCACKCMPTMR
RBSETUPRSPTMR
UECAPENQRSPTMR
RBRECFGRSPTMR
RBRELRSPTMR
RLSETUPRSPTMR
RLRECFGREADYTMR
RLRELRSPTMR
RLRSTRTMR
5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000 5000
DRLAAL2ESTINDTMR
DRLRECFGCMITTMR
HOCELLUPDATERSPTMR
HORELOCREQTMR
HOPAGINGRSPTMR
HOASUTMR
HOWTTRCHRECFGRSPTMR
HOPHYCHRECFGTMR
RELOCCMDTMR
45000 45000 45000 20000 20000 20000 5000 5000 5000 15000 15000 15000 5000 5000 5000 5000 5000 5000 10000 10000 10000 5000 5000 5000
RELOCIURELCMDTMR
RELOCDATAFWDTMR
RELOCANOTHERTMR
RELOCCOMMITTMR
RELOCMOBILCONFTMR
RELOCPHYCHRECFGTMR
RELOCUTRANHOCMPTMR
RELOCFAILIURELCMDTMR
10 10 10
SYSHOPSRESUMETMR
5000 5000 5000 5000 5000 5000 5000 5000 5000 300 300 300 300 300 300 4 4 4 1 2 3
RRCSECRTMODECMPTMR
UECNTCHECKRSPTMR
CMCHRSRCRSPTMR
IUCSRELNORABTMR
IUPSRELNORABTMR
RRCCONNREJWAITTMR
MML_RNCID
CELLRESELECTTIMER
CELLRESELECTTIMER
UUESTATETRANSTIMER
BEF2PSTATETRANSTIMER
BED2FSTATETRANSTIMER
BEH2FSTATETRANSTIMER
RTDH2FSTATETRANSTIMER
BEE2FSTATETRANSTIMER
BECPC2FSTATETRANSTIMER
RTCPC2FSTATETRANSTIMER
BED2EFACHSTATETRANSTIMER
BEH2EFACHSTATETRANSTIMER
RTDH2EFACHSTATETRANSTIMER
BECPC2EFACHSTATETRANSTIMER
RTCPC2EFACHSTATETRANSTIMER
MML_RNCID
TIMER T302 N302 T304 N304 T305 T307 T308 N308 T309 T312 N312 T313 N313 T314
T315
N315
T316
T381 N381
T323
Details T302 is started after the UE transmits the CELL UPDATE/URA UPDATE message and stopped after the UE receives the CELL UPDATE CONFIRM/URA UPDATE CONFIRM message. CELL UPDATE/URA UPDATE will be resent upon Maximum number of retransmissions of CELL UPDATE/URA UPDATE.Protocol default value is 3. T304 is started after the UE sends the UE CAPABILITY INFORMATION message and stopped after the UE receives the UE CAPABILITY INFORMATION CONFIRM message. UE CAPABILITY INFORMATION will be resent upon the expiry of the timer if V304 less than or equal N304; otherwise the cell update procedure will be initiated. Maximum number of retransmissions of UE CAPABILITY INFORMATION. Protocol default value is 3 T305 is started after the UE receives CELL UPDATE CONFIRM/URA UPDATE CONFIRM in CELL_FACH, URA_PCH or CELL_PCH state. It is stopped after the UE enters another state. CELL UPDATE will be transmitted upon the expiry T307 is started after T305 has expired and the UE detects "out of service area". It is stopped after the UE detects "in service area". The UE will enter idle mode upon expiry. T308 is started after the UE transmits RRC CONNECTION RELEASE COMPLETE. This message will be sent upon the expiry of the Timer if V308 less than or equal to N308, otherwise, the UE will enter idle mode. Maximum number of retransmissions of CELL UPDATE/URA UPDATE.Protocol default value is 1 T309 is started after the UE is reselected to a cell belonging to another radio access system in connected mode, or the CELL CHANGE ORDER FROM UTRAN message is received. It is stopped after the UE is successfully connected in the new cell. The UE will continue the connection to UTRAN upon expiry. Protocol default value is T312 is started when UE starts to establish a DCH, and stopped when UE detects consecutive N312 "in sync" indications from L1. It indicates physical channel setup failure upon the expiry of the timer. Maximum number of successive "in sync" indications received from L1. T313 is started after the UE detects consecutive N313 "out of sync" indications from L1. T313 is stopped after the UE detects consecutive N315 "in sync" indications from L1.It indicates Radio Link (RL) failure upon expiry. Maximum number of successive "out of sync" indications received from L1. T314 is started when the criteria for radio link failure are fulfilled and only radio bearers (RBs) associated with T314 exist.T314 is stopped after the Cell Update procedure has been completed. In case of the RL failure when the UE is in CELL_DCH state, If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corresponding T314 (or T315), CELL UPDATE will be resent for RL reconfiguration (this operation T315 is started when the criteria for radio link failure are fulfilled, and only the radio bearer associated with T315 exists.T315 is stopped after the Cell Update procedure has been completed. In case of the RL failure when the UE is in CELL_DCH state, T315 (or T314) is started and CELL UPDATE is sent. If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corresponding T315 (or T314), CELL UPDATE will be resent for RL reconfiguration (this operation relates to T302 and N302). T315 should be set greater than T315 is started when the criteria for radio link failure are fulfilled, and only the radio bearer associated with T315 exists.T315 is stopped after the Cell Update procedure has been completed.In case of the RL failure when the UE is in CELL_DCH state, T315 (or T314) is started and CELL UPDATE is sent. If the RL cannot be successfully reconfigured by CELL UPDATE CONFIRM before the expiry of the corresponding T315 (or T314), CELL UPDATE will be resent for RL reconfiguration (this operation relates to T302 and N302). T315 should be set greater than T316 is started after the UE detects "out of service area" in URA_PCH or CELL_PCH state.T316 is stopped after the UE detects "in service area".The cell update procedure will be initiated upon the expiry of the timer if "in service area" is detected; otherwise, T317 will be started. The UE will enter CELL_FACH state and initiate cell T381 is started after the RNC send message "RRC CONNECTION SETUP"(or "CELL UPDATE CONFIRM"). If T381 expire and RNC does not receive "RRC CONNECTION SETUP COMPLETE"(or the response of "CELL UPDATE CONFIRM") and V381 is smaller than N381, RNC resend "RRC CONNECTION SETUP"(or "CELL UPDATE CONFIRM") and restart timer T381 and increase V381. If RNC receive "RRC CONNECTION SETUP COMPLETE"(or the response Maximum number of resend times of message "RRC CONNECTION SETUP" or "CELL UPDATE CONFIRM". default
If the UE checks that no PS/CS data is transmitted, the UE will send the SIGNALLING CONNECTION RELEASE INDICATION message to the RNC, informing the RNC to terminate the PS data session. Meanwhile, the UE starts T323. The UE shall be inhibited from sending the SIGNALLING CONNECTION RELEASE INDICATION message with the IE "Signalling Connection Release Indication Cause" set to "UE Requested PS Data session end" whilst timer
D0
D1
D30
D600 D1
INVALID