Sunteți pe pagina 1din 20

Sepam Model Selection Tool v3.

0
For interactive model selection, price quotation, specification sheet generation and BOM list click the button below.

On the Interactive sheet, use the dropdown menues to select the particular device you would like, then add it to the BOM, or click Specification Generator to create the device's Square-D now offers a 10 year specification sheet.
warranty on all new Sepam Protective Relays For Sales Support Contact Inside Sales Support: For Technical Issues Contact Technical Support: (866) 466-7627 (615) 287-3400 (option #3)

Note: To return to this front page, click the FrontPage tab or click the 'GoTo Front Page' button on the Interface & PriceSheet tabs. While using the "Interactive Sheet" the (*) symbol denotes the most cost effective option for a particular model.

Capacitor
C86 C86 80 Series Capacitor Protection Relay, 24-250Vdc (includes 5 digital outputs) $3,825.00

Compare Substation Relays


S24 S40 S42 S24 S40 S42 20 Series Substation Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 40 Series Substation Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 40 Series Substation Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) Applincation: Substation - S40A + Directional 67, 67N protection. Parallel main protection. ZSI and ATS 40 Series Substation Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 50 Application Substation Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 50 Application Substation Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 50 Application Substation Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 80 Series Substation Protection Relay, 24-250Vdc (includes 5 digital outputs) 80 Series Substation Protection Relay, 24-250Vdc (includes 5 digital outputs) 80 Series Substation Protection Relay, 24-250Vdc (includes 5 digital outputs) $1,483.00 $2,713.00 $3,559.00

S43 S50 S52 S53 S80 S82 S84 B21 B22 B80 B83

S43 S50 S52 S53 S80 S82 S84 B21 B22 B80 B83

$1,990.00 $2,843.00 $3,689.00 $2,120.00 $3,570.00 $3,880.00 $4,480.00 $1,953.00 $2,266.00 $3,750.00 $3,950.00

Compare Busbar Relays


20 series Busbar Protection Relay 24-250Vdc & 120-240Vac (includes 4 digital outputs) 20 series Busbar Protection Relay 24-250Vdc & 120-240Vac (includes 4 digital outputs) 80 Series Busbar Protection Relay, 24-250Vdc (includes 5 digital outputs) 80 Series Busbar Protection Relay, 24-250Vdc (includes 5 digital outputs)

Compare Generator Relays


G40 G82 G87 G88 M20 M41 M81 M87 M88 T24 T40 T42 T50 T52 T81 T82 T87 G40 G82 G87 G88 M20 M41 M81 M87 M88 T24 T40 T42 T50 T52 T81 T82 T87 40 Series Generator Protection relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 80 Series Generator Protection Relay, 24-250Vdc (includes 5 digital outputs) 80 Series Generator Protection Relay, 24-250Vdc (includes 5 digital outputs) 80 Series Generator Protection Relay, 24-250Vdc (includes 5 digital outputs) $3,609.00 $3,870.00 $4,220.00 $5,222.00 $2,009.00 $3,129.00 $3,240.00 $3,550.00 $3,840.00 $1,957.00 $2,961.00 $3,808.00

Compare Motor Relays


20 series Motor Protection Relay 24-250Vdc & 120-240Vac (includes 4 digital outputs) 40 Series Motor Protection Relay, 24-250Vdc & 120-240Vac, (includes 4 digital outputs) 80 Series Motor Protection Relay, 24-250Vdc, (includes 5 digital outputs) 80 Series Motor Protection Relay, 24-250Vdc, (includes 5 digital outputs) 80 Series Motor Protection Relay, 24-250Vdc, (includes 5 digital outputs)

Compare Transformer Relays


20 series Transformer Protection Relay 24-250Vdc & 120-240Vac (includes 4 digital outputs) 40 Series Transformer Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 40 Series Transformer Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 50 Application Transformer Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 50 Application Transformer Protection Relay, 24-250Vdc & 120-240Vac (includes 4 digital outputs) 80 Series Transformer Protection Relay, 24-250Vdc (includes 5 digital outputs) 80 Series Transformer Protection Relay, 24-250Vdc (includes 5 digital outputs) 80 Series Transformer Protection Relay, 24-250Vdc (includes 5 digital outputs)

$3,091.00 $3,938.00
$3,830.00 $4,130.00 $4,580.00

Display
A Advanced display included in base unit MimicBus Graphical Display (for series 80 only) $100.00

MimicBus DSM303 (Series 20 & 40 Only)

$450.00

R C DSM303 80 Only) (Series

Remote Display includes 6.5' connection CAT5 cable and Base Mount kit for Series 20/40 AMT840 (Replaces integrated display) Remote Display includes 6.5' connection CAT5 cable and Base Mount kit for Series 80 AMT880 (Replaces integrated display)

$540.00 $654.00

Current
0 1 2 3 A B C D E F G H I J K L 1 2 3 4 5 6 CCT640 CCA634 CCA630 CCA671 This option is for Series 20 Busbar devices. These devices (B21/B22) do not have current inputs. 1A/5A input standard on relays for current measurement, not included on voltage only relays Only for use with CSH120, 200 ground fault sensor, and CSH30 25/3150A LPCT Connector for All SEPAM Series (Except C86) Note: Used with80) Motorpact or other medium voltage starter, includes CSH30 work with model 10 Inputs + 4 Outputs Module, 24-48Vdc and 120-250V ac Capacitor Trip application 10 Inputs + 4 Outputs Module, 110-125 Vdc, 110Vac 10 Inputs + 4 Outputs Module, 220-250Vdc, 220-240Vac $0.00 $0.00 $0.00 $531.00 $616.00 $200.00 $785.00 $770.00 $1,540.00 $2,310.00 $770.00 $1,540.00 $2,310.00 $200.00 $770.00 $1,540.00 $50.00 $275.00 $771.00 $1,000.00 $325.00 $450.00 $0.00 $695.00 $1,390.00

I/O for models 20 & 40 (will not


MES114 MES114E MES114F MES120 MES120 MES120 MES120G MES120G MES120G MES120H MES120H MES120H

I/O for models 80 Max. 3 per base unit

(will not work with models 20 & 40)

14 Inputs + 6 Outputs Module, 24-48Vdc (Model 80 Only) 28 Inputs + 12 Outputs Module, 24-48Vdc (Model 80 Only) 42 Inputs + 18 Outputs Module, 24-48Vdc (Model 80 Only) 14 inputs + 6 outputs, 220-250Vdc/hi p.u. (Model 80 Only) 28 inputs + 12 outputs, 220-250Vdc/hi p.u. (Model 80 Only) 42 inputs + 18 outputs, 220-250Vdc/hi p.u. (Model 80 Only) 14 inputs + 6 outputs, 110-125Vdc/mid p.u. (Model 80 Only) 28 inputs + 12 outputs, 110-125Vdc/mid p.u. (Model 80 Only) 42 inputs + 18 outputs, 110-125Vdc/mid p.u. (Model 80 Only) 1 RS 485 Modbus Port (12 or 24 VDC Power) included with all relays (2)RS485 2wire ports, Port 1 Modbus, Port 2 Modbus, DNP3 or IEC 60870 (requires 110-240VAC/ 24250DC ext. power). Includes CCA612 CAT5 cable. (1) RS485 2wire Modbus + (1) Fiber Modbus, DNP3 or IEC 60870 (requires110-240VAC/ 24-250DC). Includes CCA612 CAT5 cable. 1 x RS485 IEC 61850 protocol port 2 Ethernet 10/100 BaseT ports (Protocol: Modbus or IEC61850 for Sepam 40/50/80, GOOSE/GSSE for Sepam 80 only) does not require ACE Com Card 2 Ethernet 100 Base FL ports (Protocol: Modbus or IEC61850 for Sepam 40/50/80, GOOSE/GSSE for Sepam 80 only) does not require ACE Com Card

Communications
ACE959 ACE969TP2 ACE969FO2 ECI850MG ACE850TP ACE850F0

RTD
A B C

used only for the following applications: Motor, Generator, Capacitor or Transformer without MET1482 (One Module) MET1482 (Two Modules)

No RTD module
8 temperature sensor input module PT_100, NI_100 & NI_120, Includes 2' connection CAT5 cable. Note: Series 20, 40 & 80 16 temperature sensor input module PT_100, NI_100 & NI_120, Includes 2' connection CAT5 cable. Note: Series 40 & 80 only

Analog Output
0 1 without MSA141 No Analog Output 1 Analog output module, software selectable 0/10mA, 0/20mA or 4/20mA (includes CCA77X cable) $0.00 $631.00 $0.00 $250.00 $0.00 $1,540.00

Series 80 Options
A B 0 1 without SFT080 without MCS025 No Logipam Logipam firmware for ladder logic programming (PLC base) No Synch Check Module Sync-check Module_ANSI-25 for model 80 only (includes ATM840 Surface Mount Plate)

SQ1 T87 A 1 J 1 A 0 A

0 Accessories - Not to be included in the relay part number


RTM CSH30 CSCT120 CSCT200 EGX100SD EGX300SD ECI850MG ACE850TP ACE850FO 3090RTM317 CSH30 CSH120 CSH200 EGX100SD EGX300SD ECI850MG ACE850TP ACE850FO ABL8RPS24030 ABL8RPS24050 Ride Through Module Recommented for AC control voltage application (for all series 20, 40 and 80) Interposing CT for Residual ground current input, use with LPCT Ground sensor CT - 120mm window (zsct) Ground sensor CT - 200mm window (zsct) Ethernet Gateway; RS-485/RS-232, 10/100 BASE TX Transparent ready Ethernet Gateway; RS-485/RS-232 serial port,10/100T Ethernet port, Webpage data interface for upto 64 devices, Modbus Protocol 1 x RS485 IEC 61850 protocol port 2 Ethernet 10/100 BaseT ports (Protocol: Modbus or IEC61850 for Sepam 40/50/80, GOOSE/GSSE for Sepam 80 only) does not require ACE Com Card 2 Ethernet 100 Base FL ports (Protocol: Modbus or IEC61850 for Sepam 40/50/80, GOOSE/GSSE for Sepam 80 only) does not require ACE Com Card Power Supply: Input 110-480VAC, Output 24VDC 3A_for upto 15 comm module Power Supply: Input 110-480VAC, Output 24VDC 5A_for upto 25 comm module $574.00 $116.00 $235.00 $378.00 $950.00 $1,895.00 $1,000.00 $325.00 $450.00 $180.00 $240.00

Software
SFT2841KIT SFT2841KIT Relay Programming Software includes CD w/relay connector cable & USB / Serial cable, necessary for programming and troubleshooting relays) Relay Programming Software includes SFT 2841 CD & SFT 2885 Logipam programming CD w/relay connector cable & USB / Serial cable Note: must have Logipam option on a series 80 relay to use Logipam programming software $275.00

SFTKIT

$495.00

Note: SFT2841 to be a free download (like ION Setup). The kit includes the program on a disk and the connection cables. Kit price may be reduced

General Selection Guide


Protection Functions
Base Current Protections Breaker Failure & Cold Load Pickup Voltage and Frequency Protection Specific

Applications
Substation S20 S24 B21 Bus Transformer T20 T24

disconnection by "rate of change of frequency" Specific Substation S40 S50 (1) directional ground fault directional ground fault and phase overcurrent S43 S53 (1) S42 S52 (1) Substation S80 directional ground fault directional ground fault and phase overcurrent disconnection by "rate of change of frequency" S82 S84

B22

Base Current, Voltage and Frequency Protection

Bus

Transformer T40 T50 (1)

T42 T52 (1) Bus B80 T81 T82 Transformer

Base Current, Voltage and Frequency Protection

Specific

Current, Voltage and Frequency Protection

Transformer and transformermachine unit differential Machine Differential

T87

Current, Voltage and Frequency Protection Current, Voltage and Frequency Protection

Voltage and frequentcy protection for two sets of bus Capacitor bank unbalance

B83

(1) Include Cold Load Pickup and Broken Wire Detection.

Motor M20

Generator

Capacitor

Motor

Generator G40

Capacitor

M41

Motor

Generator

Capacitor

M81 G82

M88 M87

G88 G87

C86

SEPAM Links: SEPAM Software downloads SEPAM Tech Library; docs, curves and specifications SEPAM Knowledgebase and FAQ's Series 20 control voltage 24-250V DC, or 110-220V AC (for AC use RTM #3090RTM317) SEPAM Relays Series 20 Voltage/Frq Protection Only SQ1B21A Bus - Voltage and Frequency
protection and ATS

Series 40 control voltage 24-250V DC, or 110-220V AC (for AC use RTM #3090RTM317) SEPAM Relays Series 40 SQ1G40A Generator - Current, Voltage and
Frequency Protection of a separate generator. For Gen-self-balance Diff "87M" add Basler BE3-50/51.

Series 80 control voltage 24-250V DC, for 110-220V AC (use RTM #3090RTM317) SEPAM Relays Series 80 SQ1B80A Busbar - Voltage protection with current
monitoring.

Voltage/Frq Protection Only SQ1B22A Bus - Voltage and Frequency


protection and ATS

SQ1M41A

Motor, FVNR, RVAT, FVR, FV2S, FR


500- 5000HP - Current protection with voltage monitoring. For motor self-balance Diff "87M" add Basler BE3-50/51.

SQ1B83A

Busbar - Two sets of Voltage inputs &


one set of Current inputs. Provides line and bus voltage monitoring.

Current Protection Only SQ1M20A Motor, FVNR, FVR 100-1500HPCurrent protection without voltage monitoring

SQ1S40A

Substation - Current & Voltage,


protection of low-capacitance Feeders / Mains in impedance grounded or solidly grounded neutral systems. Capacitor bank (delta connection)

SQ1C86A

Generator Protection coupled to other


generators or to a network

Current Protection Only SQ1S24A Substation - Current, protection of lowcapacitance Feeders / Mains in impedance grounded or solidly grounded neutral Only systems. Capacitor feeder bank Current Protection SQ1T24A Transformer - Current protection without voltage monitoring

SQ1G82A SQ1S42A Substation - (S40A + Directional 67,


67N) protection. Parallel main protection, ZSI and ATS

Generator - Current protection with


voltage monitoring and gen self-balance Diff "87M" or full percentage diff

SQ1G87A SQ1S43A Substation - (S40A + Directional 67,


67N) protection. Parallel main protection, ZSI and ATS

Generator-transformer unit differential


protection

SQ1G88A SQ1T40A Transformer - Current and voltage


protection.

Motor feeder - Current protection with


voltage monitoring. For motor self balance Diff "87M" add Basler BE3-50/51.

SQ1M81A SQ1T42A Transformer - (T40A + Directional 67,


67N). Current and voltage + Directional. Parallel transformer main protection

Motor - (M81 + 87M)Current protection


with voltage monitoring and motor self balance Diff "87M" or full percentage diff

SQ1M87A SQ1S50A Substation - Current & Voltage


protection. Same features as SQ1S40A plus 50/51 Cold Load Pickup, 50N/51N Cold Load Pickup and 46BC Broken Conductor.

Motor-transformer unit differential


protection

SQ1M88A Substation - Current & Voltage,


protection of low-capacitance Feeders / Mains in impedance grounded or solidly grounded neutral systems

SQ1S52A

Substation - (S50A + Directional 67,


67N) protection. Same features as SQ1S42A plus 50/51 Cold Load Pickup, 50N/51N Cold Load Pickup and 46BC Broken Conductor.

SQ1S80A Substation - (S80A + Directional 67,


67N). Protection of main or tie CB with load shedding, ZSI & ATS

SQ1S53A

Substation - (S50A + Directional 67,


67N) protection. Same features as SQ1S43A plus 50/51 Cold Load Pickup, 50N/51N Cold Load Pickup and 46BC Broken Conductor.

SQ1S82A Substation - (S80A + Directional 67,


67N, 27,59, 59N, 81L, 81R, 32P, 37P). Protection of main or tie CB with load shedding, ZSI & ATS

SQ1T50A

Transformer - Current and voltage


protection. Same features as SQ1T40A plus 50/51 Cold Load Pickup, 50N/51N Cold Load Pickup and 46BC Broken Conductor.

SQ1S84A Transformer - Current and voltage +


Directional. Parallel transformer main protection

SQ1T52A

Transformer - (T40A + Directional 67,


67N). Same features as SQ1T42A plus 50/51 Cold Load Pickup, 50N/51N Cold Load Pickup and 46BC Broken Conductor.

SQ1T82A Transformer - (T82 + 87T). Current and


voltage + Directional. Parallel transformer main & differential protection

SQ1T87A

Comparison of ANSI features on Substation Protection Relays


ANSI Protection Functions S24 S40 S50 S42 25 Synch-check 27 Undervoltage (L-L) 27/27S Undervoltage (L-L or L-N) 2 2 2 27D Positive sequence undervoltage 27R Remanent undervoltage 30 Annunciation Y Y Y Y 32P Directional active overpower 1 37P Directional active underpower 46 Negative sequence unbalance 1 2 2 2 46 BC Broken conductor 1 47 Negative sequence overvoltage 1 1 1 49RMS Thermal overload 50/51 Phase overcurrent 4 4 4 4 50/51 CLPU Phase overcurrent cold load pickup/blocking 1 1 50BF Breaker failure 1 1 1 1 50N/51N Ground fault / Sensitive ground fault 50G/51G 4 4 4 4 50N/51N Ground fault / Sensitive ground fault cold load pickup/blocking CLPU 1 1 59 Overvoltage (L-L or L-N) 2 2 2 59N Neutral voltage displacement 2 2 2 60/60FL CT/VT supervision Y Y Y 67 Directional phase overcurrent 2 67N/67NC Directional ground fault 2 68 Zone selective interlock (ZSI) 2 2 2 2 74 Trip circuit supervision 79 Recloser ( 4 shots ) 81H Overfrequency 2 2 2 81L Underfrequency 4 4 4 81R Rate of change of frequency 86 Latching, lockout Y Y Y Y 94/69 CB control logic Y Y Y Y The numbers in the matrix denote the number of trip points that can be configured for this ANSI code. Note: Optional Modules (1) Protection functions with 2 groups of settings (2) According to parameter setting and optional input/output modules (3) With optional MET1482 temperature input modules (4) With optional MCS025 synchro-check module

ection Relays
S52 S43 S53 S80 4 2 2 2 Y 4 2 2 Y 2 2 2 1 8 1 8 4 2 2 Y 2 2 2 2 1 8 1 8 Current peak demand Current demand Current residual Voltage L-N & L-L Voltage residual Neutral point voltage Voltage neg. sequence 1,2,3 Voltage pos. sequence 1,2,3 KW KVA KVAr KWh (calculated) KVArh (calculated) KWh (pulse counting) KVArh (pulse counting)
Frequency Temperature Harmonic distortion (I THD & V THD) Peak KW demand Peak KVAr demand

S82

S84

Metering Values
Current 1,2,3

Y 1 2 1 1 4 1 1 4 1 2 2 Y 2 2 2

Y 1 2

Y 1 2 1

2 2

4 1 4

4 1 1 4 1

8 1 8

Y 2 2

Y 2 2

4 2 Y

2 Y 2 4

4 2 Y 2 2 2 Y 2 4 Y Y

4 2 Y 2 2 2 Y 2 4 2 Y Y

Power factor

-1 - 0 - +1

2 4 Y Y Y Y

Y Y or this ANSI code.

Y Y

Metering Parameters
Acc.
+ - .5%

S24 X

S40 X X

S50 X X X X X X X X X X X X X X X X

S42 X X X X X X X X X X X X X X X X

S52 X X X X X X X X X X X X X X X X

S43 X X X X X X X X X X X X X X X X

S53 X X X X X X X X X X X X X X X X

S80 X X X X X X X X X X X X X X

S82 X X X X X X X X X X X X X X

S84 X X X X X X X X X X X X X X

+-1%
+ - .5%

+-1%
+ - .5%

X X X X X X X X X X X X X X X X X

+-1% +-1%
+ - .5%

+-1% +-1% + - 2% + - 2% +-1% +-1% +-1% +-1% +-1% +-1% +-1%


.01Hz + - 1 Deg

X
+- 1 Deg C

X
+- 1 Deg C

X
+- 1 Deg C

+-1% +-1% +-1% 0.01

X X X

X X X

X X X

X X X

X X X

X X X

X X X X

X X X X

X X X X

Comparison of ANSI features on Busbar Protection Relays


ANSI 25 27 27D 27R 27S 30 46 47 50/51 50BF 50N/51N 50G/51G 59 59N 60/60FL 68 81H 81L 81R Protection Functions Synch-check Undervoltage (L-L) Positive sequence undervoltage Remanent undervoltage Undervoltage (L-N) Annunciation Negative sequence / unbalance Negative sequence overvoltage Phase overcurrent Breaker failure Ground fault Sensitive ground fault Overvoltage (L-L or L-N) Neutral voltage displacement CT/VT supervision Zone selective interlock (ZSI) Overfrequency Underfrequency Rate of change of frequency (df/dt) _ (SQ1B22A
only_use with Gen application)

B21 2/1 (3) 2 1 Y Y 2

B22 2/1 (3) 2 1 Y Y 2

B80 4 2 2 Y Y 2 2 8 1 8 8 4 2 Y 2 2 4

B83 4 2 2 Y Y 2 2 8 1 8 8 4 2 Y 2 2 4

2 2

2 2

1 2

1 2

1 86 Latching, lockout Y Y Y Y 94/69 CB control logic Y Y Y Y Note: The numbers in the matrix denote the number of trip points that can be configured for this ANSI code.
Optional (1) Protection functions with 2 groups of settings (2) With optional MSC025 Synch Check Module (3) 2 Undervoltage (L-L) and 1 undervoltage (L-N)

The Difference between B80 and B83? B83: monitors Line and Bus voltage (2 sets of VT's)

Metering Parameters
Metering Values
Current 1,2,3

Acc.
+ - .5% + - .5% + - .5%

B21

B22

Current peak demand Current demand Current residual Voltage L-N & L-L Voltage residual Neutral point voltage Voltage neg. sequence 1,2,3 Voltage pos. sequence 1,2,3 KW KVA KVAr KWh (calculated) KVArh (calculated)
Frequency Temperature Harmonic distortion (I THD & V THD) Peak KW demand Peak KVAr demand

+-1%
+ - .5%

B80 X X X X X X X X X X X X X X X
+- 1 Deg C

B83 X X X X X X X X X X X X X X X
+- 1 Deg C

+-1% +-1% +-1% + - 2% + - 2% +-1% +-1% +-1% +-1% +-1%


.01Hz + - 1 Deg

X X

X X

X X

X X

+-1% +-1% +-1% 0.01

X X X X

X X X X

Power factor

-1 - 0 - +1

Comparison of ANSI features on Generator Protection Relays


ANSI 12 14 21B 24 25 26/63 27/27S 27D 27R 27TN/64G2 64G 30 32P 32Q 32Q/40/55 37P 38/49T 40 46 47 49RMS 50/27 50/51 50BF 50N/51N 50G/51G 50V/51V 59 59N 60/60FL 64G 64REF 67 67N/67NC 68 74 78PS 81H 81L 86 87M 87T 94/69 Protection Functions Overspeed (2 set points) Underspeed (2 set points) Underimpedance Flux control (V/Hz) Synch-check Thermostat / Buchholz Undervoltage (L-L or L-N) Positive sequence undervoltage Remanent undervoltage Third harmonic undervoltage & 100% stator ground fault Annunciation Directional active overpower Directional reactive overpower Directional reactive overpower Directional active underpower Temperature monitoring Field loss underimpedance Negative sequence unbalance Negative sequence overvoltage Thermal overload Inadvertant energization Phase overcurrent Breaker failure Ground fault / Sensitive ground fault G40 G82 G87 G88

1 2

1 2

1 2

4 2 2 2 Y 2 1 2

4 2 2 2 Y 2 1

4 2 2 2 Y 2 1

Y 1 1

8 RTD's 2 1 2 4 1

16 RTD's 16 RTD's 16 RTD's 1 1 1 2 2 2 2 2 2 2 2 2 1 1 1 8 8 8 1 1 1

4 8 8 8 Voltage restrained phase overcurrent 1 2 2 2 Overvoltage (L-L or L-N) 2 4 4 4 Neutral voltage displacement 2 2 2 2 CT/VT supervision Y Y Y Y 100% stator ground fault 2 2 2 Restricted ground fault 2 2 Directional phase overcurrent 2 2 2 Directional ground fault 2 2 2 Zone selective interlock (ZSI) 2 2 2 2 Trip circuit supervision Y Pole slip (loss of synch) 1 1 1 Overfrequency 2 2 2 2 Underfrequency 4 4 4 4 Latching, lockout Y Y Y Y Machine differential 1 Transformer differential 1 CB control logic Y Y Y Y Note: The numbers in the matrix denote the number of trip points that can be configured for this ANSI code.

Optional Modules (1) Protection functions with 2 groups of settings (2) According to parameter setting and optional input/output modules (3) With optional MET1482 temperature input modules

(4) With optional MCS025 synchro-check module

Metering Parameters
Metering Values
Current 1,2,3

Accuracy
+ - .5% + - .5% + - .5%

Current peak demand Current demand Current residual Voltage L-N & L-L Voltage residual Neutral point voltage Voltage neg. sequence 1,2,3 Voltage pos. sequence 1,2,3 KW KVA KVAr KWh (calculated) KVArh (calculated) KWh (pulse counting) KVArh (pulse counting)
Frequency Temperature Harmonic distortion (I THD & V THD) Peak KW demand Peak KVAr demand

+-1%
+ - .5%

+-1% +-1% + - 2% + - 2% +-1% +-1% +-1% +-1% +-1% +-1% +-1%


.01Hz + - 1 Deg

G40 X X X X X X X X X X X Op Op Op Op X Op X X X X

G82 X X X X X X X X X X X X X X

G87 X X X X X X X X X X X X X X

G88 X X X X X X X X X X X X X X

X X X X X

X X X X X

X X X X X

+- 1 Deg C +- 1 Deg C +- 1 Deg C

Power factor

-1 - 0 - +1

+-1% +-1% +-1% 0.01

Comparison of ANSI features on Motor Protection Relays


ANSI 12 14 26/63 27/27S 27D 27R 30 32P 32Q 32Q/40/55 37 38/49T 40 46 47 48 49RMS 50/51 50BF 50N/51N 50G/51G 51LR 59 59N 60/60FL 66 67N/67NC 68 74 78PS 81H 81L 86 87M 87T 94/69 Protection Functions Overspeed (2 set points) Underspeed (2 set points) Thermostat / Buchholz Undervoltage (L-L or L-N) Positive sequence undervoltage Remanent undervoltage Annunciation Directional active overpower Directional reactive overpower Directional reactive overpower Phase undercurrent Temperature monitoring Field loss underimpedance Negative sequence unbalance Negative sequence overvoltage Excessive starting time Thermal overload Phase overcurrent Breaker failure Ground fault / Sensitive ground fault M20 M41 M81 M87 M88

2 2 1 Y 1 1 1

4 2 2 Y 2 1 1

4 2 2 Y 2 1 1

4 2 2 Y 2 1 1

1 8 RTD's 1 1 2 4

16 RTD's 16 RTD's 16 RTD's 16 RTD's 1 1 1 2 2 2 2 1 2 2 2 1 1 1 1 2 2 2 2 4 8 8 8 1 1 1 1

4 4 8 8 8 Lock rotor 1 1 1 1 1 Overvoltage (L-L or L-N) 2 4 4 4 Neutral voltage displacement 2 2 2 2 CT/VT supervision Y Y Y Y Starts per hour 1 1 1 1 1 Directional ground fault 2 2 2 2 Zone selective interlock (ZSI) 2 2 2 2 2 Trip circuit supervision Y Y Y Pole slip (loss of synch) 1 1 1 Overfrequency 2 2 2 2 Underfrequency 4 4 4 4 Latching, lockout Y Y Y Y Y Machine differential 1 Transformer differential 1 CB control logic Y Y Y Y Y Note: The numbers in the matrix denote the number of trip points that can be configured for this ANSI code.

Optional Modules (1) Protection functions with 2 groups of settings (2) According to parameter setting and optional input/output modules (3) With optional MET1482 temperature input modules (4) With optional MCS025 synchro-check module

Metering Parameters
Metering Values
Current 1,2,3

Acc.
+ - .5% + -1% + - .5% + -1% + - .5% + -1% + -1% + - .5%

M20 X

M41 X X

M81 X X X X X X X X X X X X X X

M87 X X X X X X X X X X X X X X

M88 X X X X X X X X X X X X X X

Current peak demand Current demand Current residual Voltage L-N & L-L Voltage residual Neutral point voltage Voltage neg. sequence 1,2,3 Voltage pos. sequence 1,2,3 KW KVA KVAr KWh (calculated) KVArh (calculated) KWh (pulse counting) KVArh (pulse counting)
Frequency Temperature Harmonic distortion (I THD & V THD) Peak KW demand Peak KVAr demand

X X X X X X X X X X X X X X X X X

+-1% +-1% + - 2% + - 2% +-1% +-1% +-1% +-1% +-1% +-1% +-1%


.01Hz + - 1 Deg

X
+- 1 Deg C

X
+- 1 Deg C

X
+- 1 Deg C

Power factor

-1 - 0 - +1

+-1% +-1% +-1% 0.01

X X X

X X X X

X X X X

X X X X

Comparison of ANSI features on Transformer Protection Relays


ANSI 24 25 26/63 27/27S 27D 27R 30 32P 38/49T 46 47 49RMS Protection Functions Flux control Synch-check Thermostat / Buchholz Undervoltage (L-L or L-N) Positive sequence undervoltage Remanent undervoltage Annunciation Directional active overpower Temperature monitoring Negative sequence unbalance Negative sequence overvoltage Thermal overload T24 T40 T50 T42 T52

8 RTD's 1

16 RTD's 16 RTD's 16 RTD's 16 RTD's 2 2 2 2 1 1 1 1

2 2 2 2 2 50/27 Inadvertant energization 50/51 Phase overcurrent 4 4 4 4 4 50/51 CLPU Phase overcurrent cold load pickup/blocking 1 1 1 50BF Breaker failure 1 1 1 1 1 50N/51N Ground fault / Sensitive ground fault 50G/51G 4 4 4 4 4 50N/51N Ground fault / Sensitive ground fault cold load pickup/blocking CLPU 1 1 1 59 Overvoltage (L-L or L-N) 2 2 2 2 59N Neutral voltage displacement 2 2 2 2 60/60FL CT/VT supervision Y Y Y Y 64REF Restricted ground fault 67 Directional phase overcurrent 2 2 67N/67NC Directional ground fault 2 2 68 Zone selective interlock (ZSI) 2 2 2 2 2 74 Trip circuit supervision 81H Overfrequency 2 2 2 2 81L Underfrequency 4 4 4 4 86 Latching, lockout Y Y Y Y Y 87T Transformer differential 94/69 CB control logic Y Y Y Y Y Note: The numbers in the matrix denote the number of trip points that can be configured for this ANSI code. Optional Modules (1) Protection functions with 2 groups of settings (2) According to parameter setting and optional input/output modules (3) With optional MET1482 temperature input modules (4) With optional MCS025 synchro-check module

Metering Parameters
T81 T82 T87 2 Metering Values
Current 1,2,3

Acc.
+ - .5%

T24 X

T40 X X

+-1% Current peak demand 4 2 2 Y 2 4 2 2 Y 2 4 2 2 Y 2 Current demand Current residual Voltage L-N & L-L Voltage residual Neutral point voltage Voltage neg. sequence 1,2,3 Voltage pos. sequence 1,2,3 KW KVA KVAr KWh (calculated) KVArh (calculated) KWh (pulse counting) KVArh (pulse counting) 4 2 Y 2 2 2 2 4 Y 4 2 Y 2 2 2 2 Y 2 4 Y Y 4 2 Y 2 2 2 2 Y 2 4 Y 1 Y
Frequency Temperature Harmonic distortion (I THD & V THD) Peak KW demand Peak KVAr demand + - .5%

+-1%
+ - .5%

X X X X X X X

+-1% +-1%
+ - .5%

16 RTD's 16 RTD's 16 RTD's 2 2 2 2 2 8 1 8 2 2 8 1 8 2 2 8 1 8

+-1% +-1% + - 2% + - 2% +-1% +-1% +-1% +-1% +-1% +-1% +-1%


.01Hz + - 1 Deg

X X X X X X X X X X

Power factor

-1 - 0 - +1

+-1% +-1% +-1% 0.01

X X X

Y d for this ANSI code.

T50 X X X X X X

T42 X X X X X X

T52 X X X X X X

T81 X X X X X X X X X X X X X X

T82 X X X X X X X X X X X X X X

T87 X X X X X X X X X X X X X X

X X X X X X X X X X

X X X X X X X X X X

X X X X X X X X X X

X
+- 1 Deg C

X
+- 1 Deg C

X
+- 1 Deg C

X X X

X X X

X X X

X X X X

X X X X

X X X X

S-ar putea să vă placă și