Documente Academic
Documente Profesional
Documente Cultură
July 2001
Processes
MIG (GMAW) Welding With Optional Equipment: Pulsed MIG (GMAW-P)
Description
Invision 456P
www.MillerWelds.com
Miller offers a Technical Manual which provides more detailed service and parts information for your unit. To obtain a Technical Manual, contact your local distributor. Your distributor can also supply you with Welding Process Manuals such as SMAW, GTAW, GMAW, and GMAW-P.
Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual catalog sheets. To locate your nearest distributor or service agency call 1-800-4-A-Miller, or visit us at www.MillerWelds.com on the web.
TABLE OF CONTENTS
SECTION 1 SAFETY PRECAUTIONS - READ BEFORE USING . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Arc Welding Hazards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3. Additional Symbols For Installation, Operation, And Maintenance . . . . . . . . . . . . . . . . . . . . . 1-4. Principal Safety Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5. EMF Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 1 CONSIGNES DE SECURITE LIRE AVANT UTILISATION . . . . . . . . . . . . . . . . . . . . . 1-1. Signification des symboles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2. Dangers relatifs au soudage larc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3. Dangers supplmentaires en relation avec linstallation, le fonctionnement et la maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4. Principales normes de scurit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5. Information sur les champs lectromagntiques . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 2 DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1. Manufacturers Warning Label Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2. Symbols And Definitions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3. Manufacturers Rating Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 3 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1. Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2. Duty Cycle And Overheating . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3. Volt-Ampere Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4. Selecting A Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5. Weld Output Terminals And Selecting Cable Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6. Remote 14 Receptacle Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7. 115 Volts AC Duplex Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8. Electrical Service Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-9. Connecting Input Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 4 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1. Front Panel Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2. Mode And Voltage Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3. Meter Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 5 MAINTENANCE & TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1. Routine Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2. Blowing Out Inside Of Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3. Removing Case And Measuring Input Capacitor Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-3. Voltmeter/Ammeter Help Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4. Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 6 ELECTRICAL DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SECTION 7 PARTS LIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WARRANTY 1 1 1 3 3 4 5 5 5 7 8 8 9 9 11 11 12 12 12 13 14 15 16 17 17 18 19 19 19 20 21 21 21 22 23 24 26 28
WARNING
This product, when used for welding or cutting, produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.)
The following terms are used interchangeably throughout this manual: TIG = GTAW Stick = SMAW
OM-185 648
Invision 456P
Directives Electromagnetic compatibility Directives: 89/336/EEC, 92/31/EEC Low Voltage Directive: 73/23/EEC
Machinery Directives: 89/392/EEC, 91/368/EEC, 93/C 133/04, 93/68/EEC Standards Electromagnetic compatibility (EMC) Product standard for arc welding equipment: EN50199: December 1995 Safety Requirements for Arc Welding Equipment part 1: EN 60974-1: 1989 Degrees of Protection provided by Enclosures (IP code): IEC 529: 1989 Insulation coordination for equipment within low-voltage systems: Part 1: Principles, requirements and tests: IEC 664-1: 1992
European Contact:
Mr. Danilo Fedolfi, Managing Director MILLER Europe S.r.l. Via Privata Iseo 20098 San Giuliano Milanese, Italy 39(02)98290-1 39(02)98281-552
Telephone: Fax:
dec_con1 10/95
D If earth grounding of the workpiece is required, ground it directly with a separate cable. D Do not touch electrode if you are in contact with the work, ground, or another electrode from a different machine. D Use only well-maintained equipment. Repair or replace damaged parts at once. Maintain unit according to manual. D Wear a safety harness if working above floor level. D Keep all panels and covers securely in place. D Clamp work cable with good metal-to-metal contact to workpiece or worktable as near the weld as practical. D Insulate work clamp when not connected to workpiece to prevent contact with any metal object. D Do not connect more than one electrode or work cable to any single weld output terminal.
D Pacemaker wearers keep away. D Wearers should consult their doctor before going near arc welding, gouging, or spot welding operations.
D D D D
D D
. Signifie NOTA ; nest pas relatif la scurit. 1-2. Dangers relatifs au soudage larc
Y Les symboles prsents ci-aprs sont utiliss tout au long du prsent manuel pour attirer votre attention et identifier les risques de danger. Lorsque vous voyez un symbole, soyez vigilant et suivez les directives mentionnes afin dviter tout danger. Les consignes de scurit prsentes ci-aprs ne font que rsumer linformation contenue dans les normes de scurit numres la section 1-4. Veuillez lire et respecter toutes ces normes de scurit. Y Linstallation, lutilisation, lentretien et les rparations ne doivent tre confis qu des personnes qualifies. Y Au cours de lutilisation, tenir toute personne lcart et plus particulirement les enfants.
D Nutiliser quun matriel en bon tat. Rparer ou remplacer sur-lechamp les pices endommages. Entretenir lappareil conformment ce manuel. D Porter un harnais de scurit quand on travaille en hauteur. D Maintenir solidement en place tous les panneaux et capots. D Fixer le cble de retour de faon obtenir un bon contact mtal-mtal avec la pice souder ou la table de travail, le plus prs possible de la soudure.
D Isoler la pince de masse quand pas mis la pice pour viter le contact avec tout objet mtallique.
Il y a DU COURANT CONTINU IMPORTANT dans les convertisseurs aprs la suppression de lalimentation lectrique.
D Arrter les convertisseurs, dbrancher le courant lectrique, et dcharger les condensateurs dalimentation selon les instructions indiques dans la partie entretien avant de toucher les pices.
D D D D
D Couper lalimentation ou arrter le moteur avant de procder linstallation, la rparation ou lentretien de lappareil. Dverrouiller lalimentation selon la norme OSHA 29 CFR 1910.147 (voir normes de scurit). D Installer et mettre la terre correctement cet appareil conformment son manuel dutilisation et aux codes nationaux, provinciaux et municipaux. D Toujours vrifier la terre du cordon dalimentation Vrifier et sassurer que le fil de terre du cordon dalimentation est bien raccord la borne de terre du sectionneur ou que la fiche du cordon est raccorde une prise correctement mise la terre. D En effectuant les raccordements dentre fixer dabord le conducteur de mise la terre appropri et contre-vrifier les connexions. D Vrifier frquemment le cordon dalimentation pour voir sil nest pas endommag ou dnud remplacer le cordon immdiatement sil est endommag un cble dnud peut provoquer une lectrocution. D Mettre lappareil hors tension quand on ne lutilise pas. D Ne pas utiliser des cbles uss, endommags, de grosseur insuffisante ou mal pisss. D Ne pas enrouler les cbles autour du corps. D Si la pice soude doit tre mise la terre, le faire directement avec un cble distinct. D Ne pas toucher llectrode quand on est en contact avec la pice, la terre ou une lectrode provenant dune autre machine.
LES RAYONS DE LARC peuvent provoquer des brlures dans les yeux et sur la peau.
Le rayonnement de larc du procd de soudage gnre des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des brlures dans les yeux et sur la peau. Des tincelles sont projetes
pendant le soudage.
D Porter un casque de soudage muni dun cran de filtre appropri pour protger votre visage et vos yeux pendant le soudage ou pour regarder (voir ANSI Z49.1 et Z87.1 numr dans les normes de scurit). D Porter des protections approuvs pour les oreilles si le niveau sondre est
trop lev.
D Utiliser des crans ou des barrires pour protger des tiers de lclair et de lblouissement; demander aux autres personnes de ne pas regarder larc. D Porter des vtements de protection constitu dans une matire durable, rsistant au feu (cuir ou laine) et une protection des pieds.
D D D D D
Consignes relatives aux stimulateurs cardiaques : Les personnes qui portent un stimulateur cardiaque doivent avant tout consulter leur docteur. Si vous tes dclar apte par votre docteur, il est alors recommand de respecter les consignes cidessus.
SECTION 2 DEFINITIONS
2-1. Manufacturer s Warning Label Definitions
Warning! Watch Out! There are possible hazards as shown by the symbols. 1 1.1 Electric shock from welding electrode or wiring can kill. Wear dry insulating gloves. Do not touch electrode with bare hand. Do not wear wet or damaged gloves. Protect yourself from electric shock by insulating yourself from work and ground. Disconnect input plug or power before working on machine. Breathing welding fumes can be hazardous to your health. Keep your head out of the fumes. Use forced ventilation or local exhaust to remove the fumes. Use ventilating fan to remove fumes. Welding sparks can cause explosion or fire. Keep flammables away from welding. Do not weld near flammables. Welding sparks can cause fires. Have a fire extinguisher nearby, and have a watchperson ready to use it. Do not weld on drums or any closed containers. Arc rays can burn eyes and injure skin. Wear hat and safety glasses. Use ear protection and button shirt collar. Use welding helmet with correct shade of filter. Wear complete body protection. Become trained and read the instructions before working on the machine or welding. Do not remove or paint over (cover) the label.
1.2
1.3
2 1 1.1 1.2 1.3 2.1 2.2 2.3 2 2.1 2.2 2.3 3 3.1
3.1
3.2
3.3
3.2
3.3 4 4.1 4
+
5
+
6
4.1
+
S-179 310
1/96
2 3 1 2 3 4 5 6 4 V V > 60 s 5 V
S-179 190-A
Warning! Watch Out! There are possible hazards as shown by the symbols. Electric shock from wiring can kill. Disconnect input plug or power before working on machine. Hazardous voltage remains on input capacitors after power is turned off. Do not touch fully charged capacitors. Always wait 60 seconds after power is turned off before working on unit, OR Check input capacitor voltage, and be sure it is near 0 before touching any parts.
4/96
2 1 2 3 4 5
S-179 304-A
Warning! Watch Out! There are possible hazards as shown by the symbols. When power is applied failed parts can explode or cause other parts to explode. Flying pieces of parts can cause injury. Always wear a face shield when servicing unit. Always wear long sleeves and button your collar when servicing unit. After taking proper precautions as shown, connect power to unit.
4/96
1 1 2 3
= <60
4 5
Warning! Watch Out! There are possible hazards as shown by the symbols. Falling equipment can cause injury and damage to unit. Always lift and support unit using both handles. Keep angle of lifting device less than 60 degrees. Use a proper cart to move unit. Do not use one handle to lift or support unit.
S-179 309-A
5
1/96
Amperage
Positive
Remote
Voltage
Output
Circuit Breaker
Negative
On
Off
Inductance
Voltage Input
S-184 765
SECTION 3 INSTALLATION
3-1. Specifications
Amperes Input At Rated Load Output 60 Hz, Three-Phase 400 V KVA KW
Input Power
Voltage Range
Three Phase
450 A @ 38 Volts DC, 100% Duty Cycle; 565 A @ 38 Volts DC, 60% Duty Cycle
10 38
95
31
21.6
19.4
6 Minutes Welding
4 Minutes Resting
A/V
15
Minutes
Movement 2
OR
Location 5
Lifting Forks
Use lifting forks to move unit. Extend forks beyond opposite side of unit. 2 3 4 Lifting Handles Hand Cart Use handles to lift unit. Use cart or similar device to move unit. 4 Rating Label Use rating label to determine input power needs. 5 Line Disconnect Device Locate unit near correct input power supply. Y Special installation may be required where gasoline or volatile liquids are present see NEC Article 511 or CEC Section 20.
18 in (460 mm)
18 in (460 mm)
Total Cable (Copper) Length In Weld Circuit Not Exceeding 100 ft (30 m) Or Less Weld Output Terminals Welding Amperes
100 150 200 250 300 350 Positive (+) Negative () 400 500 600
150 ft (45 m)
200 ft (60 m)
250 ft (70 m)
300 ft (90 m)
350 ft (105 m)
400 ft (120 m)
Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
Socket Information
24 volts ac. Protected by circuit breaker CB2. Contact closure to A completes 24 volts ac contactor control circuit. 115 volts ac. Protected by circuit breaker CB1. Contact closure to I completes 115 volts ac contactor control circuit. Output to remote control; +10 volts dc in MIG mode. Remote control circuit common. 0 to +10 volts dc input command signal from remote control. Mode select. Remote inductance control. Current feedback; +1 volt dc per 100 amperes. Voltage feedback; +1 volt dc per 10 arc volts. Circuit common for 24 and 115 volts ac circuits. Chassis common.
24 VOLTS AC
115 VOLTS AC
I J
H C L N D M G E F
M N
A/V
Ref. ST-801 718
F H G
AMPERAGE VOLTAGE
GND
K *The remaining sockets are not used.
CB1 protects 115 volts ac portion of duplex receptacle and Remote 14 receptacle from overload. CB2 protects 24 volts ac portion of Remote 14 receptacle from overload. Press button to reset breaker.
L2
L1 L2 L3 1
Tools Needed:
5/16 in
Y Turn Off welding power source, and check voltage on input capacitors according to Section 5-3 before proceeding. Check input voltage available at site. Remove left side panel.
1 Input And Grounding Conductors See Section 3-8. Install ring terminals of proper size onto input conductors for connection to input filter board terminals (see illustration). 2 Line Disconnect Device
Select type and size of overcurrent protection using Section 3-8. Connect input and grounding conductors to a deenergized line disconnect device. Reinstall left side panel.
SECTION 4 OPERATION
4-1. Front Panel Controls
1 2 3 4
ST-184 761
Power On/Off Switch fan motor is thermostatically controlled and only runs when cooling is needed.
2 3 4
Inductance Control
. The
Inductance determines the wetness of the weld puddle. When set higher, wetness (puddle fluidity) increases.
ST-801 192
NOTE
Mode
MIG
The meters display the actual weld output values for approximately three seconds after the arc is broken.
Meter Reading At Idle
V A
24.5
Preset Volts V Blank A
24.5
Actual Volts V
250
Actual Amps A
Pulsed MIG
PPP
Pulse Display
PPP
Pulse Display
24.5
Actual Volts
250
Actual Amps
3 Months
Replace Damaged Or Unreadable Labels Repair Or Replace Cracked Cables Replace Cracked Torch Body
6 Months
Blow Out Inside
ST-801 718
Measure the dc voltage across the screw terminals on RC3 and RC5 as shown until voltage drops to near 0 (zero) volts. Proceed with job inside unit. Reinstall cover when finished.
2 3
V
1
HE.L
V
2
P1
A
Indicates a malfunction in the primary power circuit. If this display is shown, contact a Factory Authorized Service Agent. 2 Help 2 Display Indicates a malfunction in the thermal protection circuitry located on the left side of the unit. If this display is shown, contact a Factory Authorized Service Agent. 3 Help 3 Display Indicates the left side of the unit has overheated. The unit has shut down to allow the fan to cool it (see Section 3-2). Operation will continue when the unit has cooled. 4 Help 4 Display Indicates a malfunction in the thermal protection circuitry located on the right side of the unit. If this display is shown, contact a Factory Authorized Service Agent. 5 Help 5 Display Indicates the right side of the unit has overheated. The unit has shut down to allow the fan to cool it (see Section 3-2). Operation will continue when the unit has cooled. 6 Help 6 Display Indicates that the input voltage is too low and the unit has automatically shut down. Operation will continue when the voltage is within 15% of the operating range. If this display is shown, have an electrician check the input voltage. 7 Help 7 Display Indicates that the input voltage is too high and the unit has automatically shut down. Operation will continue when the voltage is within 15% of the operating range. If this display is shown, have an electrician check the input voltage. 8 Help 8 Display Indicates a malfunction in the secondary power circuit of the unit. If this display is shown, contact a Factory Authorized Service Agent.
HE.L
V
3
P2
A
HE.L
V
4
P3
A
HE.L
V
5
P4
A
HE.L
V
6
P5
A
HE.L
V
7
P6
A
HE.L
V
8
P7
A
HE.L
P8
5-5. Troubleshooting
Trouble
No weld output; unit completely inoperative.
Remedy
Place line disconnect switch in On position (see Section 3-9). Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 3-9). Check for proper input power connections (see Section 3-9).
Check, repair, or replace remote control. Unit overheated. Allow unit to cool with fan On (see Section 3-2).
Use proper size and type of weld cable (see Section 3-5). Clean and tighten all weld connections.
No 115 volts ac output at duplex receptacle, Remote 14 receptacle. No 24 volts ac output at Remote 14 receptacle.
Reset circuit breaker CB1 (see Section 3-7). Reset circuit breaker CB2 (see Section 3-7).
Notes
SD-185 518
2 9 3 8 4 PC1 5 11 12 7 18 15 14 13 16 17 19 20 21 6 10
. Hardware is
65
64 59 61
63
62 58 66 60 36 38
53
22
57
52
54
55
4 23 37 24 36 25
56
51
46
50
26 PC2 28 29 31 30 27
49
48
47
801 930-C
Item No.
Dia. Mkgs.
Part No.
Quantity
. . . 1 . . . . . . . . . . . . . . . . 187 234 . . . COVER, top . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 . . . . . . . . . . . . . . . . 195 585 . . . HANDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 . . . . . . . . . . . . . . +190 373 . . . PANEL, side RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 178 551 . . . INSULATOR, side . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 . . . . . . . . . . . . . . . . 185 835 . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 . . . . PC7 . . . . . . 185 697 . . . CIRCUIT CARD, filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 . . . . . . . . . . . . . . . . 185 210 . . . BRACKET, mtg filter board . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 . . . . . T1 . . . . . . . 185 524 . . . TRANSFORMER, HF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . . FM2 . . . . . . 183 918 . . . MOTOR, fan 24VDC 3000RPM 43CFM w/10 ohm resistor . . . . . . . . . . . . . 9 . . . . PC1 . . . . . . 203 309 . . . CIRCUIT CARD ASSEMBLY, control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 . . . . . . . . . . . . . . . . 194 371 . . . SPACER, al 3.500 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 . . . . . . . . . . . . . . . . 194 450 . . . BRACKET, mtg capacitor/PC board/fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 . . . . C3-6 . . . . . . 192 935 . . . CAPACITOR, elctlt 2700uf 420 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 . . . . . . . . . . . . . . . . 181 925 . . . INSULATOR, stabilizer lead . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 . . . . . Z1 . . . . . . . 180 029 . . . STABILIZER, output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 . . . . . L1 . . . . . . . 180 026 . . . INDUCTOR, input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 . . . . . T2 . . . . . . . 185 231 . . . TRANSFORMER, control 200/400VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 . . . . . . . . . . . . . . . . 180 105 . . . BRACKET, mtg transformer aux . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 . . . . CB2 . . . . . . 093 995 . . . CIRCUIT BREAKER, man reset 15A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 . . . . CB1 . . . . . . 161 078 . . . CIRCUIT BREAKER, man reset 7A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 . . . . RC2 . . . . . . 604 176 . . . RECEPTACLE, str dx grd 3W 15A 120V . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 . . . . . . . . . . . . . . . . . . . . . . . . . . . PLATE, identification (order by model & serial number) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 282 . . . COVER, receptacle weatherproof . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 . . . . . . . . . . . . . . +187 233 . . . PANEL, rear . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 526 . . . LABEL, warning electric shock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 . . . . . . . . . . . . . . . . 153 403 . . . BUSHING, snap-in nyl .750 ID x 1.000mtg hole . . . . . . . . . . . . . . . . . . . . . . 24 . . . . . . . . . . . . . . . . 025 248 . . . STAND-OFF, insul .25020 x 1.250 lg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 . . . . . W1 . . . . . . . 180 270 . . . CONTACTOR, def prp 40A 3P 24VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 . . . . C1,2 . . . . . . 188 446 . . . CAPACITOR, polyp film .5uf 900VAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 . . . . . . . . . . . . . . . . 185 992 . . . BUS BAR, capacitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 . . . . CT1 . . . . . . 181 271 . . . TRANSFORMER, current 500 turns . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 . . . . . . . . . . . . . . . . 177 547 . . . BUSHING, snap-in nyl CTMT 1.125mtg hole . . . . . . . . . . . . . . . . . . . . . . . . 30 . . . . . T4 . . . . . . . 185 208 . . . CHOKE, common mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 . . . . PC2 . . . . . . 187 243 . . . CIRCUIT CARD ASSEMBLY, interconnect . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 . . . . . . . . . . . . . . . . 179 276 . . . BUSHING, snap-in nyl 1.000 x 1.375mtg hole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 214 . . . BUS BAR, interconnecting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 . . . . . . . . . . . . . . +194 449 . . . WINDTUNNEL, RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 . . . . SR1 . . . . . . 184 260 . . . KIT, diode power module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 . . . PM1,2 . . . . . 186 656 . . . KIT, transistor IGBT module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 . . . . RT1,2 . . . . . 173 632 . . . THERMISTOR, NTC 30K ohm @ 25deg C . . . . . . . . . . . . . . . . . . . . . . . . . . 37 . . . . . . . . . . . . . . . . 179 930 . . . HEAT SINK, power module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 . . . . . . . . . . . . . . . . 204 165 . . . HEAT SINK, rect quad diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 . . . . . . . . . . . . . . . . 190 272 . . . BASE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 . . . . . . . . . . . . . . . . 180 271 . . . BRACKET, mtg choke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 . . . . . . . . . . . . . . . . 182 654 . . . GASKET, DIDT rubber . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42 . . . . L3,4 . . . . . . 180 103 . . . COIL, DIDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 . . . . . . . . . . . . . . . . 176 844 . . . CORE, ferrite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 . . . . PC3 . . . . . . 190 688 . . . CIRCUIT CARD ASSEMBLY, front panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 . . . . . . . . . . . . . . . . 182 707 . . . TERMINAL, power output black . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 . . . . C7,8 . . . . . . 186 543 . . . CAPACITOR ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47 . . . . RC1 . . . . . . 143 976 . . . RECEPTACLE W/SOCKETS, (service kit) . . . . . . . . . . . . . . . . . . . . . . . . . . 48 . . . . . . . . . . . . . . . . 180 732 . . . BOOT, neg output stud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 . . . . . . . . . . . . . . . . 179 848 . . . BOOT, pos output stud . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 . . . . . . . . . . . . . . . . 179 898 . . . PANEL, front . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 . . . . . . . . . . . . . . . . 181 245 . . . TERMINAL, power output red . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 . . . . . . . . . . . . . . . . . . . . . . . . . . . NAMEPLATE, (order by model and serial number) . . . . . . . . . . . . . . . . .
1 2 1 2 3 1 1 1 1 1 1 1 4 1 1 1 1 1 1 1 1 1 1 1 1 2 4 1 2 2 1 1 1 1 1 1 1 1 1 2 1 1 1 1 1 2 2 1 1 2 1 1 1 1 1 1
Item No.
Dia. Mkgs.
Part No.
Quantity
. . . 53 . . . . HD1 . . . . . . 168 829 . . . 54 . . . . . S1 . . . . . . . 128 756 . . . . . . . . . . . . . . . . . . . . . . 176 226 . . . 55 . . . . . . . . . . . . . . . . 174 992 . . . 56 . . . . . . . . . . . . . . . . 179 851 . . . 57 . . . . . . . . . . . . . . . . 179 928 . . . 58 . . . . FM1 . . . . . . 175 084 . . . . . . . . . C13-16 . . . . . 180 778 . . . 59 . . . . R1,2 C9,10,11,12 . . . 175 194 . . . 60 . . . . D1-4 . . . . . . 201 531 . . . 61 . . . . . . . . . . . . . . . . 179 826 . . . 62 . . . . . . . . . . . . . . +179 902 . . . 63 . . . . . . . . . . . . . . . . 183 827 . . . . . . . . . . . . . . . . . . . . . . 179 276 . . . 64 . . . . . . . . . . . . . . . . 179 310 . . . . . . . . . . PLG4 . . . . . . 131 056 . . . . . . . . . . RC10 . . . . . . 166 679 . . . . . . . . . . PLG2 . . . . . . 115 092 . . . . . . . . PLG7,19 . . . . 115 094 . . . . . . . . PLG9,11 . . . . 115 091 . . . . . . . . PLG3,12 . . . . 180 776 . . . . . . . PLG5,15,16 . . . 175 026 . . . . . . . . . PLG21 . . . . . 181 410 . . . 65 . . . . . . . . . . . . . . +190 271 . . . 66 . . . . . . . . . . . . . . . . 199 840
. . . TRANSDUCER, current 1000A max . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SWITCH, tgl 3PST 40A 600VAC scr . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INSULATOR, switch power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOB, pointer .840dia x .250 ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KNOB, pointer 1.670dia x .250 ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SHROUD, fan . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOTOR, fan 24VDC 3000RPM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAPACITOR ASSEMBLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RESISTOR/CAPACITOR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . KIT, diode ultra fast recovery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . INSULATOR, rectifier . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WINDTUNNEL, LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BUS BAR, output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BUSHING, snap-in nyl 1.000 x 1.375mtg hole . . . . . . . . . . . . . . . . . . . . . . . . LABEL, warning general precautionary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HOUSING RECEPTACLE & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HOUSING RECEPTACLE PINS & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . HOUSING PLUG & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HOUSING PLUG & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . HOUSING PLUG & SOCKETS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLUG, w/leads voltage feedback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLUG, w/leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PLUG, w/leads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PANEL, side LH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BUS BAR, diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 1 1 1 1 1 1 4 2 4 1 1 1 2 2 1 1 1 1 1 1 1 1 1 4
+When ordering a component originally displaying a precautionary label, the label should also be ordered. To maintain the factory original performance of your equipment, use only Manufacturer s Suggested Replacement Parts. Model and serial number required when ordering parts from your local distributor.
* * * * * *
APT, ZIPCUT & PLAZCUT Model Plasma Cutting Torches Remote Controls Accessory Kits Replacement Parts (No labor) Spoolmate 185 & Spoolmate 250 Canvas Covers
Millers True Blue Limited Warranty shall not apply to: 1. Consumable components; such as contact tips, cutting nozzles, contactors, brushes, slip rings, relays or parts that fail due to normal wear. Items furnished by Miller, but manufactured by others, such as engines or trade accessories. These items are covered by the manufacturer s warranty, if any. Equipment that has been modified by any party other than Miller, or equipment that has been improperly installed, improperly operated or misused based upon industry standards, or equipment which has not had reasonable and necessary maintenance, or equipment which has been used for operation outside of the specifications for the equipment.
2.
3.
* *
2.
Original main power rectifiers Inverters (input and output rectifiers only) Transformer/Rectifier Power Sources Plasma Arc Cutting Power Sources Semi-Automatic and Automatic Wire Feeders Inverter Power Supplies Intellitig Engine Driven Welding Generators (NOTE: Engines are warranted separately by the engine manufacturer.) DS-2 Wire Feeder Motor Driven Guns (w/exception of Spoolmate 185 & Spoolmate 250) Process Controllers Positioners and Controllers Automatic Motion Devices RFCS Foot Controls Induction Heating Power Sources Water Coolant Systems HF Units Grids Maxstar 140 Spot Welders Load Banks Miller Cyclomatic Equipment Running Gear/Trailers Plasma Cutting Torches (except APT & SAF Models) Field Options (NOTE: Field options are covered under True Blue for the remaining warranty period of the product they are installed in, or for a minimum of one year whichever is greater.)
* * * * * *
MILLER PRODUCTS ARE INTENDED FOR PURCHASE AND USE BY COMMERCIAL/INDUSTRIAL USERS AND PERSONS TRAINED AND EXPERIENCED IN THE USE AND MAINTENANCE OF WELDING EQUIPMENT. In the event of a warranty claim covered by this warranty, the exclusive remedies shall be, at Millers option: (1) repair; or (2) replacement; or, where authorized in writing by Miller in appropriate cases, (3) the reasonable cost of repair or replacement at an authorized Miller service station; or (4) payment of or credit for the purchase price (less reasonable depreciation based upon actual use) upon return of the goods at customer s risk and expense. Miller s option of repair or replacement will be F.O.B., Factory at Appleton, Wisconsin, or F.O.B. at a Miller authorized service facility as determined by Miller. Therefore no compensation or reimbursement for transportation costs of any kind will be allowed. TO THE EXTENT PERMITTED BY LAW, THE REMEDIES PROVIDED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES. IN NO EVENT SHALL MILLER BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING LOSS OF PROFIT), WHETHER BASED ON CONTRACT, TORT OR ANY OTHER LEGAL THEORY. ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY IMPLIED WARRANTY, GUARANTY OR REPRESENTATION AS TO PERFORMANCE, AND ANY REMEDY FOR BREACH OF CONTRACT TORT OR ANY OTHER LEGAL THEORY WHICH, BUT FOR THIS PROVISION, MIGHT ARISE BY IMPLICATION, OPERATION OF LAW, CUSTOM OF TRADE OR COURSE OF DEALING, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE, WITH RESPECT TO ANY AND ALL EQUIPMENT FURNISHED BY MILLER IS EXCLUDED AND DISCLAIMED BY MILLER. Some states in the U.S.A. do not allow limitations of how long an implied warranty lasts, or the exclusion of incidental, indirect, special or consequential damages, so the above limitation or exclusion may not apply to you. This warranty provides specific legal rights, and other rights may be available, but may vary from state to state. In Canada, legislation in some provinces provides for certain additional warranties or remedies other than as stated herein, and to the extent that they may not be waived, the limitations and exclusions set out above may not apply. This Limited Warranty provides specific legal rights, and other rights may be available, but may vary from province to province.
miller_warr 7/00
3.
* * * * * * * * * * * * * * * * *
4. 5.
* *
Owners Record
Please complete and retain with your personal records.
Model Name Purchase Date Distributor Address City State Zip Serial/Style Number
(Date which equipment was delivered to original customer.)
For Service
Call 1-800-4-A-Miller or see our website at www.MillerWelds.com to locate a DISTRIBUTOR or SERVICE AGENCY near you.
PRINTED IN USA
1/01