Introduction To obtain an Excel spreadsheet for activated sludge/secondary clarifier design calculations, click here to go to our download page. Obtain a convenient, easy to use primary and secondary clarifier design spreadsheet for only $10.95. Read on for information about the use of an Excel spreadsheet for secondary clarifier design calculations. Secondary Clarifier Design Parameters The parameters typically used for activated

sludge/secondary clarifier design are the surface overflow rate (SOR), solids loading rate (SLR), and weir overflow rate (WOR). Activated sludge parameters are shown in the flow diagram at the right. The equations defining these three parameters are: SOR = Qo/A, SLR = (Qo + Qr)X/A, and WOR = Qo/L, where: Qo = primary effluent flow rate in MGD (U.S.) or m3/d (S.I.) A = total surface area for secondary clarifier(s) in ft2 (U.S.) or m2 (S.I.) Qr = recycle activated sludge flow rate in MGD (U.S.) or m3/d (S.I.) X = mixed liquor activated sludge solids concentration in mg/L (U.S. or S.I.) L = length of secondary clarifier effluent weir Typical values of surface overflow rate and solids overflow rate for activated sludge secondary clarifier design are shown in the tables below:

1 of 3

4/18/2013 12:44 PM

Blog Print

http://www.engineeringexceltemplates.com/blog_print.aspx?blogitemid=23

Calculation of Required Secondary Clarifier Surface Area The equation for calculating the needed secondary clarifier surface area from a design SOR value with units as shown above is: A = Qo*106/SOR The formula for calculating secondary clarifier surface area from a design value of SLR with parameter units as shown above is: A = (Qo + Qr)*8.34*X/SLR An Excel Spreadsheet as a Secondary Clarifier Design Calculator The Excel spreadsheet template shown below can be used to carry out the secondary clarifier design calculations described above. Why bother to make these calculations by hand? This Excel spreadsheet can handle the secondary clarifier surface area calculations and determine diameter for circular clarifier(s) or length and width for rectangular clarifier(s) and is available in either U.S. or S.I. units at a very low cost (only $10.95) at our download page. These spreadsheets also make weir overflow calculations to aid in effluent weir design.

2 of 3

4/18/2013 12:44 PM

Blog Print

http://www.engineeringexceltemplates.com/blog_print.aspx?blogitemid=23

Reference 1. Metcalf & Eddy, Inc, (revised by Tchobanoglous, G, Burton, F.L., Stensel, H.D., Wastewater Engineering Treatment and Reuse, 4th Edition, New York, NY, 2003.