The Instron 3300 Series addresses the needs of standardized and routine testing, providing the user Instron quality at the most affordable price. The 3380 oor model testing systems are suited for tension, compression, peel, ex, and other applications with load requirements that require testing up to 250 kN (56,200 lbf). They are typically used for heavy-duty quality control and production testing. Three models are available in load capacities of 100, 150, and 250 kN.
Instron
1838 1838
Brand C
1836
1836
1834
1834
1832
1832
1830
1830
Variability
1828
1828
*Reference paper available upon request or you can visit the literature section of www.instron.com
Specications
3382
Load Capacity kN kgf lbf mm/min in/min mm/min in/min kN lb mm/min in/min mm/min in/min mm in mm in mm in mm in mm in mm in kg lb VA 100 10,000 22,500 500 20 0.005 0.0002 50 11,250 250 10 600 24 1,235 48.5 1,323 51.3 575 22.6 2,393 94.2 1,124 44.3 779 30.7 766 1,690 1,500 100 120 220 230 240
3384
150 15,000 33,750 500 20 0.005 0.0002 75 16,850 250 10 600 24 1,235 48.5 1,323 51.3 575 22.6 2,393 94.2 1,124 44.3 779 30.7 769 1,700 1,700 120 200/208 220 230 240
3385H
250 25,000 56,200 500 20 0.005 0.0002 100 22,500 200 8 500 20 1,180 46.6 1,282 50.5 575 22.6 2,393 94.2 1,124 44.3 779 30.7 866 1,910 2,950 200/208 220 230 240
Maximum Speed
Common Specications
Load Measurement Accuracy 0.5% of reading down to 1/100 of load cell capacity. Meets or exceeds ASTM E4, BS 1610, DIN 51221, ISO 7500/1, EN 10002-2. JIS B7721, JIS B7733, and AFNOR A03-501 standards. Strain Measurement Accuracy: 0.5% of reading down to 1/50 of full scale with ASTM E83 class B or ISO 9513 class 0.5 extensometers. Meets or exceeds ASTM E83, BS 3846, ISO 9513, and EN 10002-4 standards. Crosshead Speed Accuracy (Zero or constant load): 0.2% of set speed Power Suppply 47 to 63 Hz. Must be free of spikes, surges, or sags exceeding 10% of the nominal voltage. Operating Temperature: +10 to +38C (+50 to +100F) Storage Temperature: -40 to +66C (-40 to +150F) Humidity Range: +10 to +90%, non-condensing Atmosphere: Designed for use under normal laboratory conditions. Protective measures may be required if excessive dust, corrosive fumes, electromagnetic elds, or hazardous conditions are encountered.
Minimum Speed
Return Speed
Height
Width
Depth
VAC
Notes: 1. All systems conform to all relevant European standards and carry a CE mark. 2. Total vertical test space on all systems is the distance from the top surface of the base platen to the bottom surface of the moving crosshead, excluding load cell, grips,and xtures. The above specications were developed in accordance with Instrons standard procedures and are subject to change without notice.
www.instron.com
Worldwide Headquarters 825 University Ave, Norwood, MA 02062-2643, USA Tel: +1 800 564 8378 or +1 781 575 5000 European Headquarters Coronation Road, High Wycombe, Bucks HP12 3SY, UK Tel: +44 1494 464646 Instron Industrial Products 900 Liberty Street, Grove City, PA 16127, USA Tel: +1 724 458 9610
Instron is a registered trademark of Illinois Tool Works Inc. (ITW). Other names, logos, icons and marks identifying Instron products and services referenced herein are trademarks of ITW and may not be used without the prior written permission of ITW. Other product and company names listed are trademarks or trade names of their respective companies. Copyright 2010 Illinois Tool Works Inc. All rights reserved. All of the specications shown in this document are subject to change without notice.