Sunteți pe pagina 1din 14

LITERATURE REVIEW doi: 10.1111/j.1478-5153.2010.00430.

The ventilator care bundle and its impact on ventilator-associated pneumonia: a review of the evidence
Petra Lawrence and Paul Fulbrook
ABSTRACT Aims and objectives: The aim of this review was to critically analyse recent research that has investigated ventilator care bundle (VCB) use, with the objective of analysing its impact on ventilator-associated pneumonia (VAP) outcomes. Background: The VCB is a group of four evidence-based procedures, which when clustered together and implemented as an all or nothing strategy, may result in substantial clinical outcome improvement. VAP is a nosocomial lung infection associated with endotracheal tube use in ventilated patients. Since the VCB was introduced there have been several studies that have reported signicant VAP rate reductions. Search strategy: A comprehensive search for research, published between 2004 and 2009, was conducted using Medline and PubMed. Key words were used to identify English language studies reporting VCB implementation within adult intensive care units (ICU) and associated clinical outcomes. Studies that implemented bundle variations that did not include all four elements were excluded. Conclusions: Because of the limitations of the observational designs used in the studies retrieved, a denitive causal relationship between VCB use and VAP reduction cannot be stated. However, the evidence to date is strongly indicative of a positive association. Several studies reported the use of additional VCB elements. In these cases it is difcult to establish which elements are related to the measured outcomes. Further research is recommended to establish baseline outcome measures using the four-element VCB, before adding further processes singly, as well as research investigating the effect of audit and feedback on VCB compliance and its effect on clinical outcomes. Relevance to clinical practice: A reduction in VAP is associated with VCB use. The evidence to date, whilst not at the highest experimental level, is at the highest ethically permissible level. In the absence of contradictory research, the current evidence suggests that use of the VCB represents best practice for all eligible adult ventilated patients in ICU.
Key words: Microaspiration Nosocomial lung infection Ventilator-associated pneumonia Ventilator care bundle

INTRODUCTION
It is important for those working in critical care environments to examine their practices to ensure they are evidence based. The purpose of evidence-based practice is to apply existing research evidence (to practice). Evidence to inform practice comes in a variety of forms and there are many ways that evidence can be applied in a practice setting, for example, through the development of evidence-based protocols or care pathways (Fulbrook, 2003). One method that has been gaining

Authors: P Lawrence, RN, BN, Research Assistant, Nursing Research & Practice Development Centre, The Prince Charles Hospital, Brisbane, Australia; P Fulbrook, RN, PhD, MSc, PGDipEduc, BSc (Hons), Professor of Nursing, National Centre for Clinical Outcomes Research, Australian Catholic University, Brisbane, Australia; Nursing Director Research & Practice Development, Nursing Research & Practice Development Centre, The Prince Charles Hospital, Brisbane, Australia. Address for correspondence: P Fulbrook, The Prince Charles Hospital, Rode Road, Chermside, Brisbane 4032, Queensland, Australia E-mail: paul_fulbrook@health.qld.gov.au

ground over the last decade is the care bundle. It was originally described in the critical care nursing literature by Fulbrook and Mooney (2003) as a group of several evidence-based practices: The idea is that several practices, when used in combination, or as a cluster, all of the time, have a greater effect on the positive outcome of patients (p. 250). This holistic principle is familiar to nurses: the whole is greater than the sum of its parts. Care bundles provide a method for establishing best clinical practice, which in theory will improve clinical effectiveness of interventions (Fulbrook and Mooney, 2003). A variety of care bundles has been reported in the literature including those covering sepsis management, cardiovascular risk reduction, antibiotic use and management of central venous catheters (Cooke and Holmes, 2007; Fong et al., 2007; Poe et al., 2007; Smith, 2007). However, the most well known, which has been implemented widely, is the ventilator care bundle (VCB). The primary purpose of this paper is to present

222

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses Vol 16 No 5

Ventilator care bundle and its impact on ventilator-associated pneumonia

a review of the evidence associated with use of the VCB and its effect on VAP rates.

BACKGROUND Care bundles


A bundle usually consists of three to ve interventions which are grouped together into a single quality measure (Aboelela et al., 2007). The process measures relate to a common disease and together provide a more robust picture of quality than any single measure (Berenholtz et al., 2004). Berenholtz et al. (2002) conceptualized the idea of bundling evidence-based interventions, with each element of the bundle being well dened and based on strong evidence. Their systematic review of the literature between 1965 and 2000 identied all studies that provided a potential measure of quality of intensive care. Six outcome measures were identied: intensive care unit (ICU) mortality rate; ICU length of stay (LOS) greater than seven days; average ICU LOS; average days on mechanical ventilation; optimal pain management; and patient/family satisfaction. In general, processes are easier to measure than outcomes and can be used to provide immediate feedback to providers regarding their performance. Six process measures were also identied, and these were: effective assessment of pain; appropriate use of blood transfusions; prevention of VAP; assessment of sedation; appropriate gastric ulcer prevention; and deep vein thrombosis prophylaxis (DVTP). The latter four measures were grouped together by the Joint Commission on Accreditation of Healthcare Organisations (JCAHO) to form the VCB (see IHI, 2006): head of bed elevation; daily interruption of sedation and assess readiness to wean; gastric ulcer prevention; DVTP. The VCB clustered together four evidence-based interventions that were based on evidence that was sufciently strong to suggest that they should be applied to all ventilated intensive care patients all the time. To test these process measures, the VCB was implemented in a 14-bed ICU for one year (Berenholtz et al., 2004). The results showed that increased compliance with all four elements of the VCB resulted in reduced mortality, ICU LOS, hospital days, and costs. Around this time, the Institute for Healthcare Improvement (IHI) launched the Saving 100 000 lives campaign and conducted a multi-centre ICU study in the USA and Canada from 2002 to 2004, to investigate the relationship between compliance with the VCB and its

effects on clinical outcomes (OKeefe et al., 2008). This landmark study was signicant because it demonstrated that the VCB not only reduced ventilator days and ICU LOS, but also dramatically reduced VAP rates. Since the VCB was rst introduced it has been adopted in many ICUs throughout the world. Berenholtz et al. (2002) emphasized the importance of linking process with outcome measures, and several research studies have been conducted to evaluate the impact of the VCB on related measurable outcomes. To date, the research evidence suggests that the most signicant impact of the VCB is its effect on reducing ventilator-associated pneumonia (VAP).

VAP
VAP is a nosocomial infection of the lung parenchyma that is associated with the use of endotracheal tubes in ventilated patients; however, the association is with the use of articial airways as opposed to mechanical ventilation itself (Valencia and Torres, 2009). Patients are predisposed to VAP because the endotracheal tube mechanically breaches the bodys normal defence mechanisms which resist the entry of pathogens into the lungs. Colonization of the oropharynx and the stomach with potentially pathogenic organisms precedes the development of VAP (Collard et al., 2003) and the articial airway acts as a pathway for bacteria to enter the respiratory tract. Secretions which may harbour pathogenic bacteria accumulate below and above the endotracheal tube cuff, and may become dislodged and enter further into the lower lungs during ventilation ow, tube manipulation or suctioning (Tablan et al., 2003). The mucocilliary transport system is hindered because of the suppression of cough reex by the use of sedatives and muscle relaxants, and the normal closure of the epiglottis is impaired, resulting in an incomplete seal of the laryngeal structures that protect airways (Berenholtz et al., 2004; Pruitt and Jacobs, 2006; OKeefe et al., 2008). In summary, the most important mechanism of VAP is the colonisation of the aero digestive tract with pathogenic bacteria and the subsequent aspiration of the contaminated secretions into the lower airways (Collard et al., 2003; Tablan et al., 2003; Shaw, 2005; Pruitt and Jacobs, 2006). Additional risk factors that predispose patients to VAP include pre-existing comorbidities, such as malnutrition, chronic obstructive pulmonary disease, poor oral hygiene, and chronic sinusitis (Shaw, 2005; OKeefe et al., 2008). A comprehensive review of 13 VAP studies revealed an ICU incidence of between 5% and 67% (mean 236%) with crude reported mortality of between 24% and 76% (mean 465%) (Chastre and Fagon, 2002). An earlier
223

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

Ventilator care bundle and its impact on ventilator-associated pneumonia

Canadian study found that VAP-attributable mortality of around 30% was variable depending on the population and infecting organism (Heyland et al., 1999). VAP may increase ICU patients LOS by 4361 days and hospitalization may be extended by 49 days; it is estimated that this represents an added cost of $40 000 (US) per patient per hospital admission (Tablan et al., 2003; American Thoracic Society, 2005). VAP can be difcult to diagnose, and there is still no consensus about the best microbiological diagnostic method (Bouza and Burillo, 2009). In the USA, the Centers for Disease Control (CDC, 2009) advises the use of a combination of radiological, clinical and laboratory criteria, which includes observation of the development of new or progressive pulmonary inltrates, with fever, leukocytosis and purulent tracheobronchial secretions. Clinical criteria together with cultures of sputum or tracheal specimens may be sensitive for bacterial pathogens but they are highly non-specic, which makes diagnosis difcult (Lisboa and Rello, 2008). Diagnosis can also be problematic because of the difculty of separating the infection from other lower respiratory infections such as tracheobronchitis (American Thoracic Society, 2005). Bronchoscopic techniques are therefore recommended to retrieve lung samples for histology review; however, this is invasive and can cause complications such as hypoxaemia, bleeding or arrhythmia (Tablan et al., 2003). Time of onset is an important variable for specic pathogens and outcomes (Shaw, 2005). Pneumonia is considered to be ventilator associated if the patient was intubated at the time or within 48 h of the onset of infection; there is no minimum period that the ventilator must be in place in order for the pneumonia to be considered ventilator associated (IHI, n.d.). The pathogen associated is usually a community-acquired pathogen such as Streptococcus pneumoniae, Haemophilus inuenzae and Morazella catarrhalis, which has a better prognosis as these bacteria are usually antibiotic sensitive (Pruitt and Jacobs, 2006). Late-onset VAP is associated with increased morbidity and mortality and generally occurs 72 h or more after intubation. The development of VAP at this time is usually caused by antibiotic-resistant organisms such as Staphylococcus aureus, Acinetobacter baumannii, Pseudomonas aeruginosa, Klebsiella pneumonia and the enterobacter species (Pruitt and Jacobs, 2006; Westwell, 2008). These antibiotic-resistant pathogens also vary between hospitals and within hospitals (Tablan et al., 2003).
224

METHOD Search strategy


A comprehensive search for primary research articles was conducted using the Medline and PubMed databases, using the keywords ventilatorassociated pneumonia, VAP, ventilator bundle and care bundle, and combining searches using VAP with guideline, implementation, adherence, compliance, feedback and audit. The reference lists of retrieved articles were also examined as a potential source. Data were extracted by sample and setting, study design, type of intervention, methodological quality and reported outcomes.

Inclusion criteria
Primary studies were included if they met the following criteria: English language experimental research published between 2004 and 2009; studies which implemented the VCB (including those that used additional elements) in an ICU setting; clinical outcome measures were reported.

Exclusion criteria
Studies were excluded if clinical outcomes were not measured. For example, studies which examined the effectiveness of an education intervention targeted at health care personnel but did not investigate clinical outcomes associated with VCB use. Other exclusions included research conducted in paediatric settings, and other variations of the VCB such as those with less than four of the required elements.

RESULTS
The search strategy yielded 10 research studies, which are summarized in Table 1, and two literature reviews, which were excluded from this review. OKeefe et al. (2008) evaluated six studies but also included VCBs which did not incorporate all four elements of the VCB, and Zilberberg et al. (2009) evaluated four studies with all four elements of the VCB.

Bundle elements
The four elements of the VCB are based upon the highest level of evidence, i.e. systematic review of randomized controlled trials (RCT) and single RCTs (Berenholtz et al., 2002). Several of the studies reviewed employed additional elements (interventions) that were bundled with the original VCB (see Table 1). The VCB used by Papadimos et al. (2008) was part of

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

Table 1 Summary of studies reviewed Additional bundled elements Feedback Measures VAP/1000 days Morbidity/mortality Comparisons to NNIS rates: 2004 From 17 to 027/1000 days (85% reduction) Not reported but likely to result in decreasing LOS, morbidity and mortality and improving patient safety Medical ICU: 027/1000 days NNIS 49/1000 days NHSN: not available NNIS rates: 2004 From 193 to 73/1000 days (p = 00004) (62% reduction) NNIS rates 2004 No difference No difference No difference (although trend to signicance p = 007) Higher severity of illness index (p = 0001) No difference Outcomes

Authors (Country)

Interventions

Khorfan (2008) (USA)

Multi-disciplinary teams Daily checklist (every shift) and review Staff education

Oral care Out of bed

Sharing results with staff

Papadimos et al. (2008) (USA) VAP/1000 days Patient demographics Surgical ICU days LOS Severity of illness index Medical diagnostic categories

FASTHUG mnemonic Multi-disciplinary teams (intensivist-led) Daily patient evaluation (a.m. and p.m.) Allowing procedural changes

Feeding evaluation Blood glucose monitoring Pain assessment

None described

DuBose et al. (2008) (USA)

Multi-disciplinary teams Daily checklist Daily review of non-compliance with


VAP/1000 days Ventilation duration Self-extubation rate Compliance (process)

None

None described

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses From 163 to 89/1000 days (45% reduction) >24 h: pre 901%; 1 month 864%; 3 month 867% >48 h: pre 817%,;1 month 722%; 3 month 722% >72 h: pre 740%; 1 month 609%; 3 month 617% From 78 to 22/1000 days Trend improvement HOB: 352845% (p < 005) SEDHOL: 7886% (p < 005) GUP: 762923% (p < 005) DVTP: 912928% (p = ns) VAP/1000 days

immediate correction

Staff education Monthly review of deciencies Allowing procedural changes Visual reminders

Youngquist et al. (2007) (USA) and feedback

None

Monthly compliance audit

Involved in the IHI collaborative Multi-disciplinary teams Daily checklist and review All or nothing approach to VCB Constant presence of nurse specialist

ICU LOS Compliance (process)

for informal assessments

Mercy: from 601 to 22/1000 days (63% reduction) Unity: from 266 to 0/1000 days (100% reduction) NNIS rates: 2004 Mercy: p = ns Unity: p = 002 100%

Ventilator care bundle and its impact on ventilator-associated pneumonia

Written communication Fact sheets, in services Visual reminders Allowing procedural changes

225

226

Table 1 (Continued) Interventions Additional bundled elements Feedback Measures VAP/1000 days Outcomes From 133 to 88/1000 days (34% reduction)

Authors (Country)

Unahalekhaka et al. (2007) (Thailand)

Collaborative of 18 Thai hospitals Hospital directors signed approval Multi-disciplinary teams Forms for data collection Staff education including national and

None

None described

regional workshops and face-to-face meetings

Self-administered questionnaire Allowing procedural changes Monthly feedback


VAP/1000 days From 82 to 33/1000 days (60% reduction) (p = 002) NNIS rates 2004 Decreased Average: 8049 days

Berriel-Cass et al. (2006) (USA) Average ventilator days ICU LOS

Ventilator care bundle and its impact on ventilator-associated pneumonia

Involved in the IHI collaborative Oral care Multi-disciplinary teams Hand-washing Daily checklist and review Daily audit of DVTP and gastric ulcer prophylaxis

with immediate follow-up Allowing procedural changes Staff education Train the trainer approach

Hatler et al. (2006) (USA)

Oral care

Poster of weekly results of

11453/1000 days (54% reduction) Average: 44359 days 73986%

HOTSPUD mnemonic Multi-disciplinary teams Patient goals Allowing procedural changes Staff education: newsletters, reports Visual reminders Cognitive theory of change Recognition activities Identication of barriers

VAP/1000 days compliance and VAP rates, ICU LOS improvements and transitions, Compliance (process) and with efforts for next month

Resar et al. (2005) (Canada and USA)

VAP/1000 days Compliance (process) ICU mortality ICU LOS

Collaborative for IHI None Multi-disciplinary teams Daily goals Staff education All or nothing approach to VCB ICU teams posted data monthly on a web-based

35 units overall: (VAP 45% reduction): 6627/ 1000 days (59% reduction) (p < 001) 21 units with 95% compliance Not reported Not reported

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

extranet and submitted narrative descriptions describing the changes tested and strategies implemented Monthly review of data

Table 1 (Continued) Additional bundled elements Feedback Measures Outcomes

Authors (Country)

Interventions

Hampton et al. (2005) (USA) goals and desired outcomes, and weekly quality data. Weekly graph compliance monitoring Monthly report card Number of re-intubations ICU LOS Mortality Compliance

Plan-do-check-act quality improvement

None

Bulletin board with evidence, aims, Ventilator days

methodology Multi-disciplinary teams Nurse and physician champions Allowing procedural changes Staff education: In services Visual reminders (posters) Compliance monitoring three times/week Implementation of one intervention at a time

Average: 6135 days (43% reduction) No increase Average: 40359 days (18% reduction) Decreased more than 50% Near 100%

Crunden et al. (2005) (UK) ICU LOS

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

Multi-disciplinary teams Daily checklist Two audits to assess compliance (baseline

None

Ventilator days (survivors)

and after 7 months) Monthly feedback Data collected using WordWatcher database Education sessions

Compliance (process)

Average: 10861 days (p < 005) (44% reduction). Median ventilator days fell from 3 to 2 days Average: 137 days (SD 1911) to 83 days (SD 1021) (reduction of 39%) (p < 005) Mean duration 108 days (SD 1558) to 61 days (SD 888) (43% reduction) Overall compliance: 702791% HOBE: 7183% SEDHOL: 2963% GUP: 100100% DVTP: 8171%

Ventilator care bundle and its impact on ventilator-associated pneumonia

DVTP, deep vein thrombosis prophylaxis; GUP, gastric ulcer prophylaxis; HOBE, head of bed elevation; ICU, intensive care unit; LOS, length of stay; NHSN, National Healthcare Safety Network; NNIS, National Nosocomial Infections Surveillance; SEDHOL, sedation hold; VAP, ventilator-associated pneumonia.

227

Ventilator care bundle and its impact on ventilator-associated pneumonia

the FASTHUG bundle (Vincent, 2005) and included feeding assessment, blood glucose monitoring and pain assessment elements. The evidence for these additional elements is not based on research of patients who are mechanically ventilated and therefore they may not be suitable as VCB components. Rather, they are better suited as an addition to a daily patient goals checklist, where the VCB is also a component (DuBose et al., 2008; Khorfan, 2008). Another addition to the VCB in several of the studies was oral care (Berriel-Cass et al., 2006; Hatler et al., 2006; Khorfan, 2008), which is supported by strong evidence. A metaanalysis of chlorhexidine oral care indicated a VAP reduction of 30%, with the benet most marked in cardiac surgery patients (Chlebicki & Safdar, 2007). Berriel-Cass et al. (2006) included hand-washing as a part of their VCB; however, as reported by the authors, hand-washing was the hardest part of the bundle to measure. Different methods were used in an attempt to gather rigorous data, including peer observations, charge nurse observations, and sign in sheets. However, in practice, hand-washing fell to an honour system with auditing performed by a senior nurse.

local barriers and facilitation of behaviour change (Sinuff et al., 2008). Two studies used mnemonics to help to promote change. Hatler et al. (2006) used HOTSPUD and Papadimos et al. (2008) used FASTHUG. The latter authors considered this an important aspect of the intervention, suggesting that use of the mnemonic created a heightened awareness across disciplines regarding the details of the interventions.

VCB compliance
Compliance with the VCB is an important factor, as it may take some time before a level of compliance is achieved that impacts on outcomes. Half of the studies reviewed reported VCB compliance rates. The large multi-centre study by Resar et al. (2005) demonstrated that increased compliance with the VCB resulted in greater reduction in VAP rates. ICUs with over 95% compliance rates had a 59% decrease of VAP, whereas across all 35 units, there was a 45% decrease. Unahalekhaka et al. (2007) also reported that increased compliance with the VCB decreased incidence of VAP. Two studies (Hatler et al., 2006; Youngquist et al., 2007) included compliance audit and feedback in their intervention; however, the effect of feedback was not measured. Youngquist et al. (2007) provided monthly compliance feedback to staff with a target compliance of 95%, implementing a variety of strategies to improve compliance, including education events. Compliance at two months was 93%, and at six months into the study 100% compliance was achieved. Papadimos et al. (2008) extended their data collection period for an extra year because of initially poor results. In their rst data collection period the VAP rate fell from 193/1000 to 166/1000. However, during their extended data collection period, which also involved reinforcement of procedural interventions (which implied that compliance improved), the VAP rate fell signicantly to 73/1000. Certain components of the VCB were harder to implement than others. Four studies had difculty with head of bed elevation compliance but commented that extra education resulted in increased compliance (Hampton et al., 2005; Berriel-Cass et al., 2006; Youngquist et al., 2007; DuBose et al., 2008). DuBose et al. (2008) reported that at month 1, head of bed elevation education was their primary focus and with the use of visual reminders they were able to increase compliance from 32% to 845%. Head of bed elevation compliance was also problematic for Hampton et al. (2005). Near 100% compliance was not achieved for nearly a year and extra education was needed for staff, family members and support staff. Berriel-Cass et al. (2006) did not include compliance as one of their process measures, but

Implementation strategies
The studies reviewed applied a variety of implementation strategies, which included using multidisciplinary teams to review ventilated patients, daily reviews, staff education and written education materials, visual reminders, and compliance audits (see Table 1). Most studies used the VCB protocol guidelines and measurement tools dened by IHI. Six studies included audit and feedback as part of their implementation strategy. Two studies used posters for weekly feedback, using graphs and other descriptions (Hampton et al., 2005; Hatler et al., 2006), and three other studies provided feedback monthly (Crunden et al., 2005; Berriel-Cass et al., 2006; Youngquist et al., 2007). Khorfan (2008) described sharing results but provided little detail about how it was done. Crunden et al. (2005) commented that monthly feedback was important because it reminded clinical staff about their accountability and helped to maintain a priority focus on the intervention. Hatler et al. (2006) presented a novel way to implement the VCB, focussing on behaviour change strategies. This approach enabled researchers to identify barriers and promote recognition activities such as thankyou notes and movie tickets to establish the new behaviour (the VCB) as the norm. However, the impact of this intervention was not investigated. Hampton et al. (2005) included nurse and physician champions to provide direction and inuence but did not measure their effect, which may be related to their knowledge of
228

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

Ventilator care bundle and its impact on ventilator-associated pneumonia

commented that staff resisted head of bed elevation for reasons which included concerns about pressure ulcer development and blood pressure complications. Compliance with sedation holds was also difcult because of minimal physician support. Khorfan (2008) reported perfect compliance with both DVT and gastric ulcer prophylaxis, whereas Crunden et al. (2005) reported decreased compliance with their DVT protocol.

VCB outcomes
A variety of outcome measures was used across the 10 studies to indicate effects associated with use of the VCB (see Table 1). Those reported most frequently were VAP rates, ventilator days, ICU LOS, and mortality. Half of the studies also reported on VCB compliance (process measure).

ndings. In three studies, VAP rates per 1000 days were higher than both NNIS and NHSN data (Hatler et al., 2006; Papadimos et al., 2008; Unahalekhaka et al., 2007). However, these studies still demonstrated VAP reductions of 54%, 62% and 34%, respectively. NHSN claims that a high rate of VAP does not necessarily dene a problem but it does suggest an area for further investigation (Edwards et al., 2008). Also, a low VAP rate may be the result of inadequate infection surveillance (Edwards et al., 2008). Khorfan (2008) and Youngquist et al. (2007) both reported VAP rates/1000 days below both the NNIS and the NHSN VAP averages, with the former study reporting a VAP reduction of 85% and the latter reporting zero postintervention VAP incidence in one centre.

Ventilator days VAP rates


VAP surveillance was reported in all but two studies (Crunden et al., 2005; Hampton et al., 2005). Overall, there was a trend in the reduction of VAP incidence per 1000 days with lowest and highest reductions being 34% (Unahalekhaka et al., 2007) and 85% (Khorfan, 2008). Of the eight studies reporting VAP rates, most used the CDC diagnosis guidance (Tablan et al., 2003; CDC, 2009). In the USA, both the National Nosocomial Infections Surveillance (NNIS, 2004) and National Healthcare Safety Network (NHSN) (Edwards et al., 2008) provide VAP rate data, according to ICU type (see Table 2), and several studies used these data to benchmark their Five studies (Crunden et al., 2005; Hampton et al., 2005; Berriel-Cass et al., 2006; DuBose et al., 2008; Khorfan, 2008) reported pre- and post-data about ventilator days, revealing an overall decrease. Hampton et al. (2005) reported a similar reduction of 426% to Crunden et al.s (2005) reported 435%. However, the latter study reported on surviving patients only. DuBose et al. (2008) reported a 37131% decrease in duration of mechanical ventilation at month 1, but at month 3 found little or no further reductions. Khorfan (2008) reported the number of ventilator days, but did not report on the sample size, so average ventilator days was not recorded. Berriel-Cass et al. (2006) reported a decrease but did not quantify it.

Table 2 NNIS 20022004 and NHSN 20062007 average VAP rates/1000 days: by type of ICU. In 2005, NNIS became amalgamated with other CDC surveillance departments to become NHSN Medical/surgical: major teaching 54 33 Pre Medical/surgical: all others 51 23 Pre

Medical NNIS: January 2002June 2004 NHSN: January 2006Dec 2007 Results Khorfan (2008) Papadimos et al. (2008) DuBose et al. (2008) Youngquist et al. (2007) Unahalekhaka et al. (2007) Berriel-Cass et al. (2006) Hatler et al. (2006) Resar et al. (2005) 4 9 2 5 Pre 17

Surgical 93 53 Pre 193

Trauma 152 93 Pre

Pooled average 75 51 Pre

Post 027

Post

Post

Post 73

Post

Post

601 266 82 33

22 00

163

89

133 114 66

88 53 27

NHSN, National Healthcare Safety Network; NNIS, National Nosocomial Infections Surveillance; VAP, ventilator-associated pneumonia. Mercy. Unity.

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

229

Ventilator care bundle and its impact on ventilator-associated pneumonia

ICU LOS and mortality


Six studies reported ICU LOS. Papadimos et al. (2008) found no difference, whereas the remaining ve studies all reported reductions ranging from 15% to 392% (Crunden et al., 2005; Hampton et al., 2005; Berriel-Cass et al., 2006; Hatler et al., 2006; Youngquist et al., 2007). Only two studies provided specic information about mortality rates, indicating a trend in its reduction. Hampton et al. (2005) reported a large decrease in mortality of 50%, whereas Crunden et al. (2005) found a 9% reduction. However, in the latter study there was an increase in the number of ventilated patients during the study period. Khorfan (2008) indicated that one of the project goals was to reduce mortality; however the mortality data were not reported, suggesting somewhat vaguely that the VAP bundle was likely to result in . . . decreasing morbidity and mortality (p. 17).

data from retrospective chart reviews (Crunden et al., 2005; Hampton et al., 2005; Youngquist et al., 2007). Of these, only Youngquist et al. reported an attempt to control selection bias. In their study, the patients charts were reviewed by a clinical nurse specialist and a respiratory care advisory team, who attempted to benchmark performance using a revised set of CDC guidelines for nosocomial surveillance. The limitation of retrospective comparison is that the two groups are never likely to be totally comparable with respect to all factors, and there is often missing or incomplete information or inaccuracies in the data (Polit and Beck, 2007). Furthermore, there may be other variables affecting the outcome in one period that were not present in another.

Samples
Three of the studies were multi-centred ones; Youngquist et al. (2007) used two sites, Unahalekhaka et al. (2007) used 18 sites, with the largest study by Resar et al. (2005) collecting data from 35 sites. Of these, only Youngquist et al. identied its ICU sample group (medical/surgical) and reported on the number of patient days. The two largest multi-centre studies (Resar et al., 2005; Unahalekhaka et al., 2007) did not provide information about individual ICUs, such as the type of ICU or the size of the sample drawn from each. This information is important for benchmarking, as NNIS and NHSN aggregate data, across several years, reveal differences between different types of ICU (NNIS, 2004; Edwards et al., 2008). The other seven research settings were single ICUs ranging in size from 6 to 18 beds. Of the single-centre studies, ve reported their sample size (Crunden et al., 2005; Hampton et al., 2005; Youngquist et al., 2007; DuBose et al., 2008; Khorfan, 2008). Prospective studies may require large samples if the variable of interest is rare. The VAP rate is normally described in terms of its incidence per 1000 ventilation days. Although the majority of studies reported this outcome, there was a large variance in the number of ventilator days for which data were recorded. For example, Youngquist et al. (2007) reported on 205 patient ventilator days in 2003 and 224 days in 2004, whereas DuBose et al. (2008) reported 810 ventilator days over the three months of their study and Khorfan et al. (2008) recorded 3681 ventilator days over three years.

CRITIQUE Design
The research design for all 10 studies was prospective, observational, pre- and post-intervention. All used non-randomized samples, with no concurrent controls for comparison. Resar et al. (2005) commented on their prospective observational design and stated that given its design and lack of bias controls, the research could not establish a causal link between the use of the bundle and a reduction in VAP. They noted that, historically, only experimental research study had been able to support the concept of causality. However, the IHI and JCAHO consider RCTs for this type of research to be unethical because the interventions have already been demonstrated to be effective (Papadimos et al., 2008). Nevertheless, well-controlled prospective observational studies are considerably stronger than retrospective studies and are best for examining causal relationships and to test a hypothesis, especially when the phenomenon is not amenable to randomized controlled experimental designs. In addition, samples for prospective designs may be more representative and investigators may be able to impose tighter controls for bias and confounding factors to rule out competing explanations of the results and to ensure the validity of the research (Polit and Beck, 2007). In an attempt to benchmark their data, Unahalekhaka et al. (2007) used a time-series approach with the pre-intervention period representing baseline data, whereas Khorfan (2008) used NNIS (2004) data for their baseline. A limitation of the latter form of benchmarking is the relevance of the compared data; the NNIS average VAP rate may be different to that of a particular ICU. Three studies gathered baseline
230

Data collection
Although all 10 studies reported some information about data collection processes, the details were not uniform, comprehensive or complete. For example,

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

Ventilator care bundle and its impact on ventilator-associated pneumonia

Papadimos et al. (2008) reported that hand-washing compliance was aggressively enforced by infection control employees; however, they did not report on data collection of the other process measures such as VAP surveillance and patient demographics. Hampton et al. (2005) reported on compliance monitoring which was performed three times per week: once by the clinical nurse specialist, again by the unit manager and a third time by a manager from another unit. However, they did not detail how and by whom VAP surveillance, ICU LOS, and mortality data were collected. The tools used for data collection were also not comprehensively reported. Only three studies provided examples of their data collection tools (Hatler et al., 2006; DuBose et al., 2008; Khorfan, 2008). Two studies used a computer-based information system as a data source (Crunden et al., 2005; Resar et al., 2005) and seven studies stated that data were collected using either a daily checklist or daily goals sheet (Crunden et al., 2005; Berriel-Cass et al., 2006; Hatler et al., 2006; Youngquist et al., 2007; DuBose et al., 2008; Khorfan, 2008; Papadimos et al., 2008).

DISCUSSION
All of the 10 studies that were reviewed are limited by their research designs in that they did not have control groups. However, it is argued that this would be unethical because the VCB is known to improve outcomes. In addition, the studies employed various methods to collect data, of which several were subject to potential collector bias. If no specic control is imposed on data collection and recording, the possibility for incomplete data or inaccurate data is increased. Another limiting factor, in terms of the research design, was that the studies were unblinded. Although it is conceded that it would be very difcult to blind the VCB intervention, this can mean that people who are aware that they are part of an audited study alter their recording of events and their practices in such a way that it does not reect their usual practice. This is especially the case with observational designs and can impact on the true nature of results. The four elements of the VCB are based on strong evidence, i.e. systematic reviews of RCTs and single RCTs (Berenholtz et al., 2002). Compared to when they are implemented individually, the premise is that when the four elements are bundled together as a suite of practices, it will lead to signicantly improved outcomes for ventilated patients. The ndings from this review support this: the measures employed in each of the studies demonstrated improved outcomes

for patients. As noted above, there was a variety of outcome measures recorded. Nevertheless, there were demonstrably positive results in all studies, with reported decreases in VAP days per 1000 ventilator days, average ventilator days and average ICU LOS. Only one study reported mortality data, which demonstrated a signicant reduction of 50%. Whilst this reduction was large, there are many other variables that may have impacted, and further multicentre research is needed to evaluate the impact of VCB implementation and compliance on mortality. A recent meta-analysis of audit and feedback found that despite mixed ndings in previous reviews, they are reasonably effective tools for changing provider behaviour and quality of care, if designed correctly (Hysong, 2009). Improving compliance with the VCB has been shown to improve VAP outcomes. For example, Cocanour et al. (2006) demonstrated that daily audit of compliance with a modied VCB and weekly feedback reporting of results was associated with a statistically signicant decrease in VAP rates. In a more recent multi-centre improvement study, increased VCB compliance from 50% to 82% was associated with a 41% reduction in VAP (Bonello et al., 2008). Several of the studies reviewed reported different rates of compliance with each of the VCB elements. However, it is important to note that compliance with the VCB is an all or nothing measure. It is dened by IHI (2006, p. 1) as The percentage of intensive care patients on mechanical ventilation for whom all four elements of the ventilator bundle are implemented and documented on the daily goals sheet and/or elsewhere in the medical record. Some studies reported their overall VCB compliance rates, and where these data were available, there was a clear trend to suggest that the better the adherence to the VCB, the greater the reduction in VAP incidence and ventilator days. Thus, if a relationship between process measures (i.e. VCB compliance) and improved outcome measures (e.g. VAP reduction) can be demonstrated, health care providers may be able to monitor performance using process measures rather than the more resource-intensive outcome measures (Resar et al., 2005). It is important to also note that if a bundle element is contra-indicated for a particular patient (for example, DVTP in a patient with a bleeding disorder) then that element should still be regarded as compliant (IHI, 2006). The value of the VCB as a cluster of interventions has been questioned in relation to VAP reduction, on the basis that only one element (head of bed elevation) is directly associated (Wip and Napolitano, 2009). Head of bed elevation between 30 and 45 decreases the risk of aspiration of gastric and oropharyngeal secretion plus aids ventilation and minimizes atelectasis.
231

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

Ventilator care bundle and its impact on ventilator-associated pneumonia

Its inclusion in the VCB is based on the research by Drakulovic et al. (1999) who showed that the semirecumbent body position reduced frequency and risk of nosocomial pneumonia in mechanically ventilated patients, especially those receiving enteral nutrition. However, if sedation hold and assessment of readiness to wean result in earlier extubation then the risk of VAP may be reduced. In several of the studies that were reviewed, additional elements were added to the VCB. This makes it difcult to determine what proportion of the outcome effect was attributable to the VCB itself. Although it is conceded by IHI that there are several adjunct elements which have been added to the VCB in many ICUs that are supported by strong evidence, e.g. subglottic drainage (Dezfulian et al., 2005), it does not wish to add further elements to the existing bundle because of its demonstrated effectiveness in achieving zero rates of VAP (IHI, 2008). It is argued that although there is a tendency for ICUs to implement all possible interventions, this may be unnecessary, as a select few is effective in minimizing risks. Furthermore, it is difcult to make comparisons between ICUs in which different elements have been added to the VCB. IHI (2008) encourages researchers to maximize implementation of the existing VCB before adding other components. Thus, when baseline measures are obtained with the VCB, further components can be added singly, and their additional effect on outcomes can be measured. There was a variety of implementation strategies used in the VCB studies reviewed. All used several methods to implement the VCB, including the use of staff education sessions, supportive written material, reminders and multi-disciplinary team meetings. A recent meta-analysis suggested a multifaceted approach to guideline implementation such as an active educational strategy combined with a reminder and audit, and feedback system is an effective approach for knowledge transfer in the ICU (Sinuff et al., 2008). However, the authors also stated that further research is needed to increase the understanding of effective strategies to improve clinical outcomes for critically ill patients. Signicant gaps remain in the transfer of research into clinical practice and, although clinical guidelines may improve processes of care, their use alone is insufcient to change clinician behaviour (Sinuff et al., 2008). Although not specically related to VCB implementation, some studies have demonstrated signicant VAP reduction when structured multi-disciplinary education programs were implemented (Babcock et al., 2004; Salahuddin et al., 2004). Although use of the VCB has demonstrated reduced VAP rates, there are other interventions that have been shown to reduce VAP, and it should not be assumed
232

that the VCB is the only appropriate intervention. Other evidence-based interventions have been comprehensively reported by the Canadian Clinical Trials Group (Muscedere et al., 2008). However, of particular interest is the degree of head of bed elevation, and further studies are warranted to test a more easily achievable 1030 position (Wip and Napolitano, 2009).

CONCLUSIONS
Because of the limitations of the observational design used in the studies reviewed, a denitive causal link between the VCB and VAP incidence, length of ventilation, and ICU LOS cannot be proved. However, the weight of evidence in terms of the magnitude of difference in the measured outcomes especially with regard to VAP reduction suggests a strong relationship. As noted above, the association is considered to be so strong that it is considered by IHI and JCAHO to be unethical not to use the VCB. It should also be emphasized that, individually, each of the VCB elements is supported by its own experimental evidence at the highest level and, on this basis, each in its own right should be implemented for ventilated patients. In the absence of rigorous research evidence suggesting otherwise, standard practice should involve the use of the VCB for all adult ventilated ICU patients. A limited number of studies suggests that VCB compliance impacts on outcomes. Thus, when the VCB is used, it is important to audit compliance rates and accordingly implement processes that help ensure sustained outcomes. In terms of further research, it would be advisable to develop further prospective studies, which are controlled tightly in order to be able to measure VCB effects. In particular, further research is needed to demonstrate the effect of regular feedback on VCB compliance, and its subsequent effect on outcomes. In general, processes are easier to measure than outcomes and can be used to provide immediate feedback to providers regarding their performance. However, further research would be helpful to demonstrate which implementation and audit/feedback strategies are most effective in achieving clinician behaviour change that results in improved clinical outcomes. With respect to the VCB, rigorous research is needed to establish the supplementary benet of other elements such as tight glucose control, which others have added. This requires the use of good baseline data with the VCB alone, followed by individual implementation and outcome monitoring of additional elements. Thorough evaluation strategies are needed to establish best practice and create a benchmark against which other process measures can be assessed.

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

Ventilator care bundle and its impact on ventilator-associated pneumonia

WHAT IS KNOWN ABOUT THIS TOPIC The VCB is a group of four evidence-based procedures, which when clustered together and implemented as an all or nothing strategy, may result in substantially greater clinical improvement. VAP is a nosocomial lung infection associated with microaspiration via an endotracheal tube in ventilated patients. Since the VCB was introduced there have been several studies that have reported signicant VAP rate reductions associated with its implementation. WHAT THIS PAPER ADDS This paper has reviewed the evidence from studies that have investigated outcomes associated with VCB implementation. It is concluded that the VCB is associated with improved VAP outcomes. This review has identied that there is a lack of consistency in methodological approach in the various studies reviewed. This review has identied that some studies have used the VCB with added elements, which make it difcult to determine which elements are responsible for the measured outcomes. This review has identied that the level of compliance with the VCB impacts on outcomes, and therefore further research is required in this area.

REFERENCES
Aboelela SW, Stone PW, Larson EL. (2007). Effectiveness of bundled behavioural interventions to control healthcareassociated infections: a systematic review of the literature. Journal of Hospital Infection; 66: 101108. American Thoracic Society. (2005). Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia. American Journal of Respiratory Critical Care Medicine; 171: 388416. Babcock HM, Zack JE, Garrison T, Trovillion E, Jones M, Fraser VJ, Kollef MH. (2004). An educational intervention to reduce ventilator-associated pneumonia in an integrated health system. Chest; 125: 22242231. Berenholtz S, Dorman T, Ngo K, Provonost PJ. (2002). Qualitative review of intensive care quality indicators. Journal of Critical Care; 17: 112. Berenholtz SM, Milanovich S, Faircloth A, Prow DI, Earsing K, Lipsett P, Dorman T, Pronovost PJ. (2004). Improving care for the ventilated patient. Joint Commission Journal on Quality and Safety; 30: 195204. Berriel-Cass D, Adkins FW, Jones P, Fakih MG. (2006). Eliminating nosocomial infections as Ascension Health. Joint Commission Journal on Quality and Patient Safety; 32: 612620. Bonello RS, Fletcher CE, Becker WK, Clutter KL, Arjes SL, Cook JJ, Petzel RA. (2008). An intensive care unit quality improvement collaborative in nine Department of Veteran Affairs hospitals: reducing ventilator-associated pneumonia and catheter-related bloodstream infection rates. Joint Commission Journal on Quality and Safety; 34: 639645. Bouza E, Burillo A. (2009). Advances in the prevention and management of ventilator-associated pneumonia. Current Opinion in Infectious Diseases; 22: 345351. Centers for Disease Control (CDC). (2009). Ventilator-associated pneumonia (VAP) event. In: NHSN Manual: Patient Safety Component Protocols. [Online]. Available at: http://www.cdc. gov/nhsn/PDFs/pscManual/6pscVAPcurrent.pdf (accessed 20/04/10). Centers for Disease Control and Prevention, Atlanta GA, USA. Chastre J, Fagon J. (2002). Ventilator-associated pneumonia. American Journal of Respiratory and Critical Care Medicine; 165: 867903.

Chlebicki MP, Safdar N. (2007). Topical chlorhexidine for prevention of ventilator associated pneumonia: a meta analysis. Critical Care Medicine; 35: 595602. Cocanour CS, Peninger M, Domonoske BD, Li T, Wright B, Valdivia A, Luther KM. (2006). Decreasing ventilator associated pneumonia in a trauma ICU. The Journal of Trauma, Injury, Infections, and Critical Care; 61: 122130. Collard HR, Saint S, Matthay MA. (2003). Prevention of ventilatorassociated pneumonia: an evidence-based systematic review. Annals of Internal Medicine; 138: 494501. Cooke FJ, Holmes AH. (2007). The missing care bundle: antibiotic prescribing in hospitals. International Journal of Antimicrobial Agents; 30: 2529. Crunden E, Boyce C, Woodman H, Bray B. (2005). An evaluation of the impact of the ventilator care bundle. Nursing in Critical Care; 10: 242246. Dezfulian C, Shojania K, Collard HR, Kim HM, Matthay MA, Saint S. (2005). Subglottic secretion drainage for preventing ventilator associated pneumonia: a meta analysis. The American Journal of Medicine; 118: 1118. Drakulovic MB, Torres A, Bauer TT, Nicolas JM, Nogue S, Ferrer M. (1999). Supine body position as a risk factor for nosocomial pneumonia in mechanically ventilated patients: a randomised trial. Lancet; 354: 18511858. DuBose JJ, Inaba K, Shiett A, Trankiem C, Teixeira PGR, Salim A, Rhee P, Demitriades D, Belzberg H. (2008). Measurable outcomes of quality improvement in the trauma intensive care unit: the impact of a daily quality rounding checklist. The Journal of Trauma, Injury, Infection and Critical Care; 64: 2229. Edwards JR, Peterson KD, Andrus ML, Dudeck MA, Pollock DA, Horan TC. (2008). National Healthcare Safety Network (NHSN) Report, data summary for 2006 through 2007, issued November 2008. American Journal of Infection Control; 36: 609626. Fong JJ, Cecere K, Unterborn J, Garpestad E, Klee M, Devlin JW. (2007). Factors inuencing variability in compliance rates and clinical outcomes among three different severe sepsis bundles. The Annals of Pharmacotherapy; 41: 929936. Fulbrook P. (2003). Developing best practice in critical care nursing: knowledge, evidence and practice. Nursing in Critical Care; 8: 96102.

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

233

Ventilator care bundle and its impact on ventilator-associated pneumonia

Fulbrook P, Mooney S. (2003). Care bundles in critical care: a practical approach to evidence-based practice. Nursing in Critical Care; 8: 249255. Hampton DC, Grifth D, Howard A. (2005). Evidence-based clinical improvements for mechanically ventilated patients. Rehabilitation Nursing; 30: 160165. Hatler CW, Mast D, Corderella J, Mitchell G, Howard K, Aragon J, Bedker D. (2006). Using evidence and process improvement strategies to enhance healthcare outcomes for the critically ill: a pilot project. American Journal of Critical Care; 15: 549554. Heyland DK, Cook DJ, Grifth L, Keenan SP, Brun-Buisson C for the Canadian Critical Care Trials Group. (1999). The attributable morbidity and mortality of ventilator-associated pneumonia in the critically ill patient. American Journal of Respiratory and Critical Care Medicine; 159(4 Pt 1): 12491256. Hysong SJ. (2009). Meta-analysis: audit and feedback features impact effectiveness on quality care. Medical Care; 47: 356363. Institute for Health Care Improvement (IHI). (n.d.). Ventilatorassociated pneumonia (VAP) rate per 1,000 ventilator days. [Online]. Available at: http://www.ihi.org/IHI/Topics/ CriticalCare/IntensiveCare/Measures/VentilatorAssociated PneumoniaRateper1000VentilatorDays.htm (accessed 25/02/10). Institute for Health Care Improvement (IHI). (2006). Measure Information Form: Ventilator Bundle Compliance. V06-11/27/2006. Cambridge: IHI. [Online]. Available at: http://www.ihi.org/ NR/rdonlyres/C545E638-CD5A-411B-B265-E06DD0025C1B/ 0/MIFVAPVentilatorBundleCompliance.pdf (accessed 24/02/10). Institute for Health Care Improvement (IHI). (2008). Protecting 5 million lives from harm. Getting started kit: prevent ventilator associated pneumonia. How to guide. v05 10/01/2008. [Online]. Available at: http://www.ihi.org/nr/rdonlyres/ d823e3fd-d10b-493e-a6a8-37c767825780/0/vaphowtoguide. doc (accessed 26/02/10). Khorfan F. (2008). Daily goals checklist - a goal directed method to eliminate nosocomial infection in the intensive care unit. Journal for Healthcare Quality; 30: 1317. Lisboa T, Rello J. (2008). Diagnosis of ventilator associated pneumonia: is there a gold standard and a simple approach? Current Opinion in Infectious Diseases; 21: 174178. Muscedere J, Dodek P, Keenan S, Fowler R, Cook D, Heyland D; VAP Guidelines Committee and the Canadian Critical Care Trials Group. (2008). Comprehensive evidence-based clinical practice guidelines for ventilator-associated pneumonia: diagnosis and treatment. Journal of Critical Care; 23: 138147. National Nosocomial Infections Surveillance (NNIS). (2004). National Nosocomial Infections Surveillance (NNIS) system report, data summary from January 1992 through June 2004, issued October 2004. American Journal of Infection Control; 32: 470485. OKeefe S, Santiago C, Lau G. (2008). Ventilator-associated pneumonia bundled strategies: an evidence-based practice. Worldviews on Evidence-Based Nursing; 5: 193204. Papadimos TJ, Hensley SJ, Duggan JM, Khuder SA, Borst MJ, Fath JJ, Oakes LR, Buchman D. (2008). Implementation of the FASTHUG concept decreases the incidence of ventilatorassociated pneumonia in a surgical intensive care unit. Patient Safety in Surgery; 2: 3.

Poe SS, Dawson PB, Cafeo C, Sedlander D, Curtis C, Meyer P, Blumenthal R, Baumgartner W, Allen J. (2007). Use of the ABC care bundle to standardise guideline implementation in a cardiac surgical population: a pilot study. Journal of Nursing Care Quality; 22: 247254. Polit D, Beck C. (2007). Nursing Research: Generating and Assessing Evidence for Nursing Practice, 8th edn. Sydney: Lippincott Williams and Wilkins. Pruitt B, Jacobs M. (2006). Best-practice interventions: how can you prevent ventilator-associated pneumonia? Nursing; 36: 3641. Resar R, Provonost P, Haraden C, Simmonds T, Rainey T, Nolan T. (2005). Using a bundle approach to improve ventilator care processes and reduce ventilator-associated pneumonia. Joint Commission Journal on Quality and Patient Safety; 31: 243248. Salahuddin N, Zafar A, Sukhyani L, Rahim S, Noor MF, Hussain K, Siddiqui S, Islam M, Husain SJ. (2004). Reducing ventilator-associated pneumonia rates through a staff education programme. Journal of Hospital Infection; 57: 223227. Shaw MI. (2005). Ventilator-associated pneumonia. Current Opinion in Pulmonary Medicine; 11: 236241. Sinuff T, Muscedere J, Cook D, Dodek P, Heyland D. (2008). Ventilator-associated pneumonia: improving outcomes through guideline implementation. Journal of Critical Care; 23: 118125. Smith M. (2007). A care bundle for management of central venous catheters. Paediatric Nursing; 19: 3944. Tablan OC, Anderson LJ, Besser R, Bridges C, Hajjeh R. (2003). Guidelines for preventing health-care-associated pneumonia, 2003. Recommendations of CDC and the Healthcare Infection Control Practices Advisory Committee. Part 1. Issues on preventing health care associated pneumonia, 2003. [Online]. Available at: https://www.vha.com/Solutions/ClinicalImprovement/ HAI/Documents/cdc_guidelines_preventing_associated_ pneumon.pdf (accessed 18/04/10). Centers for Disease Control, Atlanta GA, USA. Unahalekhaka A, Jamulitrat S, Chongsuvivatwong V, Ovretveit J. (2007). Using a collaborative to reduce ventilator-associated pneumonia in Thailand. The Joint Commission on Quality and Patient Safety; 33: 387394. Valencia M, Torres A. (2009). Ventilator-associated pneumonia. Current Opinion in Critical Care; 15: 3035. Vincent JL. (2005). Give your patient a fast hug (at least) once a day. Critical Care Medicine; 33: 12251229. Westwell S. (2008). Implementing a ventilator care bundle in an adult intensive care unit. Nursing in Critical Care; 13: 203207. Wip C, Napolitano L. (2009). Bundles to prevent ventilatorassociated pneumonia: how valuable are they? Current Opinion in Infectious Diseases; 22: 159166. Youngquist P, Carroll M, Farber M, Macy D, Madrid P, Ronning J, Susag A. (2007). Implementing a ventilator bundle in a community hospital. The Joint Commission on Quality and Patient Safety; 33: 219225. Zilberberg MD, Shorr AF, Kollef MH. (2009). Implementing quality improvements in the intensive care unit: ventilator bundle as an example. Critical Care Medicine; 37: 305330.

234

2011 The Authors. Nursing in Critical Care 2011 British Association of Critical Care Nurses

Copyright of Nursing in Critical Care is the property of Wiley-Blackwell and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use.

S-ar putea să vă placă și