Documente Academic
Documente Profesional
Documente Cultură
COMPLETELY
SAVINGS
Consistent high quality internal surface > CLEAN AIR Full flow connection and low friction internal surface of the pipe > HIGH FLOW RATE PERFORMANCE Calibrated pipe diameter > OPTIMUM SEALING
ENERGY
EASIER
HANDLING
Pipes and fittings are supplied ready for immediate installation > NO PREPARATION REQUIRED Quick assembly - no need to weld, glue or crimp > TIME SAVING Easy to assemble > NO IN-DEPTH TRAINING REQUIRED Lightweight, easy to cut pipe material > EASIER WORKING ON SITE Immediate Start-up > SYSTEM QUICKLY READY FOR TEST AND USE
RESISTANCE
TO
HIGH
> corrosion > aggressive environments > mechanical shocks > thermal variations > U.V.
10 YEARS
SAFETY
> non-flammable materials
Legris has a policy of continual product development and, therefore, reserves the right to modify any products shown in this catalogue, without notification. All dimensions are indicative.
> Contents
> Introduction
Technical specifications ABCDE FGHIJ Sizing KLMNO Flow rates and pressure drop PQRST Z U V W X Y Transair Flow Calculator
02 03 04 05 06 07 08 09 10
Rigid aluminium pipe Flexible hose Pipe-to-pipe and stud connectors Quick assembly brackets Wall brackets Ball valves and butterfly valves Tools Fixture accessories Hose reels - blowgun Tubes and hoses Automatic couplers Connection accessories FRLs, automatic drains and accessories Air distribution columns
14 15 16 22 26 28 30 34 38 39 40 44 48 52
Essential instructions Aluminium pipe Pipe-to-pipe and stud connectors Quick assembly brackets Flexible hose Air distribution columns Fixture accessories Practical data Transair in situ
56 58 64 76 82 87 88 94 102
> Index
106 107
>Technical specifications
>Fluids
13 bar from -20C to +60C 16 bar from -20C to +45C Maximum working pressure versus operating temperature
Pressure (bar)
Temperature (C)
98,7 % (13 mbar absolute pressure) from -20C to +60C from -40C to +80C
corrosion aggressive environments
>Resistance to
>Environment
Materials are 100% recyclable. For silicone free applications: please consult us.
2/3
>Sizing
Select the TRANSAIR diameter for your application based on required flow against pressure drop.
Estimated values for: a closed loop network, a pressure of 8 bar with 5% pressure drop. Velocity is not taken into account.
Flow rate Nm /h
3
Length 164ft cfm 6 18 29 41 59 88 147 206 294 441 589 736 883 1030 1177 1471 1766 2060 2354 2649 2943 3237 3531 50m 16,5 16,5 16,5 25 25 25 40 40 40 40 63 63 63 63 63 63 76 76 76 76 76 100 100 328ft 100m 16,5 16,5 25 25 25 40 40 40 40 63 63 63 63 63 76 76 76 76 100 100 100 100 100 492ft 150m 16,5 16,5 25 25 25 40 40 40 63 63 63 63 63 76 76 76 76 100 100 100 100 100 100* 984ft 300m 16,5 25 25 25 40 40 40 63 63 63 63 63 76 76 76 76 100 100 100 100* 100* 100* 100* 1640ft 500m 16,5 25 25 40 40 40 63 63 63 63 63 63 76 76 100 100 100 100* 100* 100* 100* 100* 100* 2460ft 750m 16,5 25 25 40 40 40 63 63 63 76 76 100 100 100 100 100* 100* 100* 100* 100* 100* 100* 100* 3280ft 1000m 16,5 25 40 40 40 40 63 63 63 76 76 100 100 100 100 100* 100* 100* 100* 100* 100* 100* 100* 4265ft 1300m 25 25 40 40 40 63 63 63 76 76 100 100 100 100 100* 100* 100* 100* 100* 100* 100* 100* 100* 5249ft 1600m 25 25 40 40 40 63 63 63 76 76 100 100 100 100* 100* 100* 100* 100* 100* 100* 100* 100* 100* 6561ft 2000m 25 40 40 40 63 63 63 76 76 100 100 100 100* 100* 100* 100* 100* 100* 100* 100* 100* 100* 100*
Compressor (Kw)
Nl/min 167 500 833 1167 1667 2500 4167 5833 8333 12500 16667 20833 25000 29167 33333 41667 50000 58333 66667 75000 83333 91667 100000
10 30 50 70 100 150 250 350 500 750 1000 1250 1500 1750 2000 2500 3000 3500 4000 4500 5000 5500 6000
1,5 - 7,5
7,5 - 30
30 - 75
75 - 315
> 315
>Example
Main network length (ring main): 300 metres Compressor power: 30 kW Required flow rate: 250 Nm3/h (147 cfm) Working pressure: 8 bar The most suitable Transair diameter is: 40.
To size your air pipework system, you can also use the TRANSAIR FLOW CALCULATOR. For more information, refer to page 4 of this catalogue.
Pressure (bar)
Pressure (bar)
4/5
The TRANSAIR FLOW CALCULATOR helps you to choose the most suitable diameter for your installation. Enter the flow of your compressor, the system pressure rating and the total equivalent length of the system. Select ring main or straight line layout, enter your preferred unit of calculation and then click for an immediate indication of the most suitable Transair diameter (with a pressure drop of less than 5%).
>Example
> Flow rate: 1 445 Nm3/h (850 cfm) at 7,5 bar (109 psi) > Ring main: 545 metres > The recommended TRANSAIR diameter is 76mm (pressure drop of 0,10 bar = less than 5 %)
>Download
The new TRANSAIR FLOW CALCULATOR from our web site : www.transair.legris.com
>Safety
>Fire resistance
All TRANSAIR components are non-flammable with no propagation of flame. pipe-to-pipe and stud connectors, ball valves and butterfly valves : conform to UL94HB standard fixture clips : conform to UL94V-2 standard flexible hoses : conform to ISO 8030 norm for compressed air applications, and to EN 12115 norm for vacuum applications pipe lacquer finish classified M0
>Electrical conductivity
In areas of potential risk, the earthing and electrical continuity of metallic components are obligatory. The Transair system can be used in such environments by undertaking the appropriate precautions. For more information, please consult us.
>CE conformity
Transair conforms to European standard 97/23 CEE - 3.3 (equipment under pressure).
g d as pipin onsidere c r e o b e ld ip u p S.A. sho icular a pros in part by LEGRIS p e a d d lu s re c a tu in c ponents Piping manufa aring com TP Commission nnectors practice. working ssure-be nsair co G a re d e p Tr n u r ll th o e a y s t th b tha rding to es, or o 99 and y declare ints, hos ned acco 8/01/19 jo ig 2 s n d e We hereb io d te s a h n d group nts whic gs, expa working ing, ttin compone ressure ipes, tub p p f e o th m y b syste tance cf accep priate 8. 9 9 1 / 1 /1 dated 27 e. 0 of practic the code 76 - 10 to g in rd 63 - o c c 0 a 4 d e design - 25 Products rs 16.5 connecto ir a s n on: Tra descripti Product 001 EN ISO 9 pproval, A f o te a Certic ls: AFAQ le approva b a c li p p A
6/7
>TV certification
A product certified TV is a pledge of safety and quality. The Group TV thus certifies independent test results in particular, the properties of the products and the standards whereby they were examined.
>QUALICOAT certification
QUALICOAT certification is a guarantee of the quality of the lacquer finish applied to Transair aluminium pipe.
>ASME B31.1
whic ponent ir com stallation. a s n ra e any T date of the in ed. identi e of charg bviously ce free years from th o la p d n re a es to of 10 clearly f Legris e. period SA agre ust be at issu ontrol o Legris fect, within a n that : the products component m e the c io id it ts d u n e o o d c e terial defects tion. alid on ss to examin other Transair installa nt, are e tee is v nsair laceme guaran asonable acc the tting or p ra t T n re e e t s c th u The pre A is given re bly defect in rnal to of prod S e cost em ent exte - Legris rial or an ass ed to th ny elem ndations. it a m h li it is w e t - A mate , which contac and recomm Legris SA. due to arantee s this gu r wear As guideline its dened by o ts conm s o n fr o roduc ti d S sair p s, vibra g with Legris e technical lim by Legris SA. Exclude r ticular: n k c ra o T h s e a in th e m r of th iar y SA, in p resulting fro n not comply sed outside ed in advanc istributo sid u v o ts to the d , and its sub ly - Defec due installati llation being ons not appro s u o e e c n ta n a ti ts s a lt c ra c in u F fe i n e im x7 .... s -D to a mod .......... writing Rennes Cede ts due roduct .......... sed in .. s 4 - Defec caused by p .. 0 re .. 7 d .. 5 d a 3 .... ts uld be 0411 .......... - Defec tee sho s, BP 7 .......... Guaran 4,r ue de Pari .......... .. .. is .. th .. r .. .. .......... A, 7 unde .......... .......... Claims nd to Legris S .......... .......... .................... .. .. .. .. .. .. a .. .. d .. .. .. cerne .......... .................... .......... .......... .......... .......... .................... .......... .. .. .. .. .. .. .. .. .. .. .. ........ .......... .................... ner .... .......... Site ow dress .......... .................... . .. .. .. .. .. .. d .. .. a .. .. Exact ........ .................. y ................ ....... r ........ it .......... Numbe .................... .....Town / C .......... .. .. .. .. .. .. .. .. .. Street e .............. ...... .......... d .. .......... Post Co .................. .......... New .. .. .. .. .. y ion ...... Countr type: Extens tion .......... g .......... a Buildin Modic .................... ........ ineers ign eng ... s e D / .. .. cts Archite r : .............. ..... ...... ibuto
rin nufactu NTEE to a ma e GUARA u d n ctio SAIR not fun - TRAN h does
g or ma
>Material
16,5 - 25 - 40
1003A 1006A 1001E air 1001E vacuum 4002 - 4012 4089 - 4099 - 4230 4981 6602 - 6604 6605 6606 6612 6621 6625 6651 6661 6662 6666 6676 6680 - 6681 6685 - 6686 EA98 RA69 RA65 Clip - Spacer Adaptor Fixture accessories Column Module Composite coupler Metal coupler Hose reel Blow gun Connections accessories Anti whip-lash strap lacquered aluminium lacquered aluminium hose and coating : black SBR reinforcement : synthetic braiding hose and coating : black SBR / NBR reinforcement : spiral steel wire engineering grade plastic body: treated brass nut: engineering grade plastic body: plated brass seal: PTFE and nitrile engineering grade plastic body : treated brass nut : polymer HR / NBR engineering grade plastic engineering grade plastic treated aluminium engineering grade plastic body : treated brass nut: engineering grade plastic body: engineering grade plastic insert : brass engineering grade plastic body : treated aluminium nut: engineering grade plastic engineering grade plastic body: treated brass nut: engineering grade plastic treated brass body : treated iron ball valve : plated brass engineering grade plastic body: engineering grade plastic insert : brass engineering grade plastic brass
63
lacquered aluminium lacquered aluminium hose and coating : black SBR reinforcement : synthetic braiding hose and coating : black SBR / NBR reinforcement : spiral steel wire body: engineering grade plastic nut: treated aluminium treated aluminium body : treated brass nut: treated aluminium / NBR treated aluminium treated aluminium treated aluminium body : engineering grade plastic insert : brass polymre HR treated aluminium body : treated aluminium nut : polymer HR engineering grade plastic galvanized steel - brass anodized aluminium aluminium TA03 TA06 EW05 FP01 RP01 RR01 RR05 RR61 RX02 RX12 RX04 RX23 RX24 RX64 RX66 RX30 VR02 VR03 Bracket
76 - 100
lacquered aluminium lacquered aluminium seal: EPDM hose and connector: black SBR/NBR reinforcement : spiral steel wire body and pushing ring : engineering grade plastic - seal: NBR clamp : treated steel cartridge : engineering grade plastic seal : NBR treated brass body: iron (EN 1563) - seal : NBR screw : treated stainless steel lining : elastomer stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 stainless steel 304 body: iron disc and shaft : stainless steel nickel-plated brass zinc steel - rubber EPDM
body : polymer HR / Zamac - sleeve : polymer HR - spring and ball bearings : stainless steel - seal : nitrile - probe : treated steel body : anodized duralumin - sleeve: treated nickel-plated steel - spring : stainless steel - seal : nitrile - probe : treated steel, treated brass plastic/metal case - fixing : metal reinforced polyamide - treated aluminium - insert brass plated brass steel
8/9
>Transair Technology
Innovative technology at the heart of TRANSAIR enables rapid and easy assembly: quick connection of components to the aluminium pipe. This technology takes into account the specific requirements of each diameter and provides the user with an optimum safety coefficient and easy connection.
Pipe-to-pipe and stud connectors in 16,5, 25 et 40 can be immediately connected to Transair pipe - simply push the pipe into the connector up to the connection mark. The gripping ring of each fitting is then automatically secured and the connection is safe.
seal
body
nut
pipe
seal
> 63
Pipe-to-pipe and stud connectors in 63 can be quickly connected to Transair aluminium pipe by means of a double clamp ring. This secures the connection between the nut and the pipe - tightening of the nuts secures the final assembly.
body nut pipe
lug
Pipe-to-pipe and stud connectors in 76 et 100 can be quickly connected to Transair aluminium pipe. Position the pipes to be connected within the Transair cartridge and close/tighten the Transair clamp.
seal cartridge clamp pipe
>Services
Internally Our CUSTOMER SERVICE teams will co-ordinate a quick response to your requirements.
Order processing and follow-up Delivery time-phasing and modification Technical information
>
Wherever you are in the world, you can contact us : by phone by fax by post by e-mail
To find the address of your nearest TRANSAIR contact, please see the INDEX of this catalogue.
10 / 11
Installation sizing System layout and drawing Shopping list Available on CDROM
Practical information
Downloadable literature files: catalogues, information on new products, introductory leaflet, instruction guidelines, newsletter.
www.transair.legris.com
All TRANSAIR CAD drawings are available on a CDROM - in formats DWG, DXF and PS.
L G D
Formal technical specifications for the TRANSAIR system are available in either Word or PDF format and can be directly integrated into your own documents.
SAVINGS
Consistent high quality internal surface > CLEAN AIR Full flow connection and low friction internal surface of the pipe > HIGH FLOW RATE PERFORMANCE Calibrated pipe diameter > OPTIMUM SEALING
ENERGY
SAFETY
COMPONENTS GUARANTEED FOR
> non-flammable materials
10 YEARS
12 / 13
Rigid aluminium pipe Flexible hose Pipe-to-pipe and stud connectors Quick assembly brackets Wall brackets Ball valves and butterfly valves Tools Fixture accessories Hose reels - blowgun Tubes and hoses Automatic couplers Connection accessories FRLs, automatic drains and accessories Air distribution columns
14 15 16 22 26 28 30 34 38 39 40 44 48 52
Blue pipe
L1
Transair
1003A17 04 00 1003A25 04 00 1006A25 04 00 1003A40 04 00 1006A40 04 00
out.
16,5 25 25 40 40
in
13 22 22 37 37
L1 (m)
3 3 6 3 6
L (m)
2,930 2,903 5,903 2,885 5,885
16,5 25 40
L1
Grey pipe
Transair
1003A17 06 00 1003A25 06 00
out.
16,5 25 25 40 40
in
13 22 22 37 37
L1 (m)
3 3 6 3 6
L (m)
2,930 2,903 5,903 2,885 5,885
L1
Blue pipe
Transair
1003A63 04 1006A63 04
out.
63 63
in
59 59
L1 (m)
3 6
L (m)
2,950 5,950
63
L1
Grey pipe
Transair
1003A63 06 1006A63 06
out.
63 63
in
59 59
L1 (m)
3 6
L (m)
2,950 5,950
Blue pipe
L
Transair
TA03 L1 04 TA06 L1 04 TA03 L3 04 TA06 L3 04
out.
76,3 76,3 101,8 101,8
in
72,3 72,3 97,2 97,2
L (m)
3,000 6,000 3,000 6,000
76 100
L
Grey pipe
Transair
TA06 L1 06 TA06 L3 06
out.
76,3 101,8
in
72,3 97,2
L (m)
6,000 6,000
EW07 00 01
0000 01 68
14 / 15
Vacuum : 98,7% (13 mbar absolute pressure) Working temperature : -20C to +60C Resistant to mineral and synthetic compressor oils Fire resistant (conforms to ISO 8030 standard for compressed air flexible hose and to EN 12.115 standard for vacuum flexible hose)
D1
38 38 38 54 54 54
D2
25 25 25 40 40 40
L (m)
0,570 1,500 2,000 1,150 2,000 3,000
For use Min. bend radius with Transair pipe diameter (mm)
25 40
L D2 D1
25 25 25 40 40 40
D1
36 36 36 52 52 52
D2
25 25 25 40 40 40
L (m)
0,570 1,500 2,000 0,950 2,000 3,000
For use Min. bend radius with Transair pipe diameter (mm)
25 25 25 40 40 40
D2
63 63 63
L (m)
1,400 3,000 4,000
For use Min. bend radius with Transair pipe diameter (mm)
63
L D2 D1
63 63 63
D1
79 76 76
D2
63 63 63
L (m)
1,400 3,000 4,000
For use Min. bend radius with Transair pipe diameter (mm)
63 63 63
76 100
L D1
Transair
FP01 FP01 FP01 FP01 L1 L1 L3 L3 01 02 02 03
D1
91 91 116 116
D2
75 75 100 100
L (m)
1,500 2,000 2,000 3,000
For use Min. bend radius with Transair pipe diameter (mm)
D2
76 76 100 100
16,5 25 40
Pipe-to-pipe connector
Transair
6606 17 00
D
16,5 25 40
G
34,0 44,5 67,0
L
120,5 151,5 205,0
Z
33,0 48,0 57,0
6606 25 00 6606 40 00
63
Transair
6606 63 00
D
63
G
91,0
L
171,5
Z
25,0
Transair
RR01 L1 00 RR01 L3 00
D
76 100
L
146 146
E1
104 128
E2
132 157
76 100
D
Transair
RP01 L1 00 RP01 L3 00
D
76 100
M
88,7 123
N
51,4 52,7
25 40
D
25 40
G
44,5 67,0
L
151,5 205,0
Z
48,0 57,0
6676 40 00
63
Transair
6676 63 00
D
63
G
91,0
L
171,5
Z
25,0
Model supplied with 1/4 threaded fitting and 8 mm push-in connection, complete with blanking plug.
16 / 17
> Max. working pressure : -13 bar from -20C to +60C -16 bar from -20C to +45C (please consult us for higher temperature requirements) > Vacuum : 98,7% (13 mbar absolute pressure) > Working temperature : -20C to +60C
90 elbow
16,5 25 40
Transair
Z
D
16,5 25 40
G
34,0 44,5 67,0
L
58,0 68,0 107,0
Z
31,0 40,0 62,0
L G D
L Z
63
D Z L G
Transair
6602 63 00
D
63
G
91,0
L
122,0
Z
61,0
76 100
D 90 Z D H H
Transair
RX02 L1 00 RX02 L3 00
D
76 100
H
227 278
Z
189 221
45 elbow
25 40
L
Z
Transair
G D
D
25 40
G
44,5 67,0
L
57,0 90,0
Z
29,0 45,0
6612 25 00 6612 40 00
76 100
L1
Transair
RX12 L1 00 RX12 L3 00
D
D
76 100
L1
235,5 271,4
L2
151,4 184,3
135 L2
Equal tee
16,5 25 40
L
Z1
Z1
Transair
6604 17 00
Z2
D
16,5 25 40
G
34,0 44,5 67,0
H
58,0 67,5 102,5
L
120,5 151,5 205,0
Z1
34,0 48,0 57,0
Z2
31,0 40,0 57,0
6604 25 00 6604 40 00
Z1
Z1 G Z2
63
D H
Transair
6604 63 00
D
63
G
91,0
H
122,0
L
245,0
Z1
61,0
Z2
61,0
76 100
Z1 D
Transair
RX04 L1 00 RX04 L3 00
D
76 100
L
290 310
Z1
145 155
Z2
145 135
Z2
Reducing tee
L
Z1
63
Transair
Z2
D1
63
D2
40
G
91,0
H
161,0
L
245,0
Z1
61,0
Z2
116,0
G
D2
D1
6604 63 40
Transair
D1
76 76 100 100
D2
40 63 40 63
L
290 290 310 310
Z1
145 145 155 155
Z2
104 163 116,5 175,8
76 100
RX24 L1 40
Z1 D1
Z2 D2
Use 2 connectors RR01 to connect reducing tee RX24 to Transair pipes 76 and 100 and to connect pipe-to-pipe connector 6606 to Transair pipes 40 and 63.
18 / 19
Threaded tee
76 100
Z1
Transair
D Z2 C
D
76 100
C
G1/2 G1/2
L
290 310
Z1
145 155
Z2
63 75,8
RX23 L1 04 RX23 L3 04
Plug-in reducer
16,5 25 40
L Z
Transair
6666 17 25 6666 25 40
D1
25 40
D2
16,5 25
G
34,0 44,5
Z
50,0 71,0
L
77,0 99,0
D1
G D2
Transair
6666 40 63
L
D1
63
D2
40
G
67,0
L
112,5
D2
63
25
63
63
61
116
80
40
40
76 100
Transair
RX64 L1 63 RX64 L3 63
D2
D1
76 100 100
D2
63 63 76
L
230 250 192,5
D1
RX66 L3 L1
Use 1 connector RR01 to connect plug-in reducer RX64 to Transair pipes 76 or 100 and 1 pipe-to-pipe connector 6606 to connect to Transair pipe 63.
16,5 25 40
Transair
6625 17 00 6625 25 00
D
16,5 25 40
E
25,5 33,0 34,5
G
34,0 44,5 67,0
H
45,5 47,0 55,0
L
62,5 75,0 98,5
6625 40 00
G D
Model 16,5 : supplied with 6 mm plug. Model 25, 40 and 63 : supplied with 8 mm plug.
63
G H
Transair
6625 63 00
D
63
E
31,0
G
91,0
H
74,0
L
111
End-cap
76 100
Transair
RX25 L1 00
D
D
76 100
L
99,6 107,4
RX25 L3 00
16,5 25 40
Transair
D G E
C
D
16,5 16,5 25 25 25 40 40 40
C
R1/4 R1/2 R1/2 R3/4 R1 R1 R11/4 R11/2
E
9,5 15,0 15,0 15,0 16,0 16,0 21,5 24,5
G
34,0 34,0 44,5 44,5 44,5 67,0 67,0 67,0
H
62,5 68,0 70,5 71,5 71,5 111,5 111,5 114,5
G D
63
H E C
Transair
6605 63 48 6605 63 47
D
63 63
C
R2 R21/2
E
20,0 25,0
G
91,0 91,0
H
118,5 130,5
20 / 21
16,5 25 40
Transair
6621 17 21 6621 25 21 6621 25 27 6621 25 34
D
16,5 25 25 25 40 40
C
R1/2 R1/2 R3/4 R1 R11/4 R11/2
L
42,2 49,0 49,0 49,0 73,7 75,7
H
5,0 7,0 7,0 7,0 8,0 10,0
L H
6621 40 42 6621 40 49
76
Transair
L H C
D
76
C
R21/2
L
125
H
20
RR05 L1 20
Manifold
25 40
L
L2 N L1 N N 12
Transair
6651 25 12 04 6651 40 12 04
D
25 40
G
44,5 67,0
L
271,0 400,0
L1
151,0 204,0
L2
23,0 27,0
N
35,0 50,0
Z
107,0 150,0
D3
D2
Flange
Transair
D1 D
D
76 76 100
DN
D1
185 200 220
D2
145 160 180
D3
18 18 18
E
10 10 10
L
75 75 75
65 80 100
76 100
Flange gasket
Transair
EW05 L1 00 EW05 L1 00 01 EW05 L3 00
D
76 76 100
C
M16
L
60
25 40
D2
D1 M Z G
Transair
RA69 25 17 RA69 40 25
D1
25 40
D2
16,5 25
M
92 117
G
34 44,5
L
37 37
N
52 74
Z
47,5 61
To drill Transair pipe, use drilling tools 6698 02 01 and 6698 02 02.
D2
76 100
C1 L
C2
Transair
RR61 L1 08 RR61 L3 08
D
75 110
C1 1 1
C2
M12 M12
E
50 80
L
137 137
Supplied with 25 - 1 adaptor (6605 25 34). To drill Transair pipe, use drilling tool EW09.
25 40
C
D
M
Transair
RA65 25 04 RA65 40 04
D
25 40
C
G1/2 G1/2
L
37 37
N
52 74
M
86 100
Supplied with blanking plug. To drill Transair pipe, use drilling tools 6698 02 01 and 6698 02 02.
22 / 23
> Integral water retention device > Quick installation without any cutting of pipe
25 40
Transair
6662 25 17 6662 25 00 6662 40 17 6662 40 25
D1
25 25 40 40
D2
16,5 25 16,5 25
M
139,5 134 154 149,5
G
34 44,5 34 44,5
L
36 36 37,5 37,5
N
63,5 63,5 76,5 76,5
Z
82 74 89 82
To drill Transair pipe, use drilling tools 6698 02 01 and 6698 02 02.
63
D1 Z
G
D2
Transair
6662 63 25
D1
63
D2
25
M
166,5
G
44,5
L
50
N
108,5
Z
75
25 40
Transair
6661 25 21 6661 40 21 6661 40 27
D1
25 40 40
C
G1/2 G1/2 G3/4
M
117,5 132 132
L
36 37,5 37,5
N
63,5 76,5 76,5
Supplied with blanking plug. To drill Transair pipe, use drilling tools 6698 02 01 and 6698 02 02.
63
Transair
6661 63 21 6661 63 27
D1
63 63
C
G1/2 G3/4
M
138,9 138,9
L
50 50
N
98,5 98,5
Supplied with blanking plug. To drill Transair pipe, use drilling tool 6698 02 02.
Quick assembly mini-brackets with pre-assembled coupler allow time savings during installation.
Transair
6660 25 U1
D
25 25 25 25 40 40 40 40
C
G1/2 G1/2 G1/2 G1/2 G1/2 G1/2 G1/2 G1/2
Profile
ISO B ISO B EURO ARO ISO B ISO B EURO ARO
Bore (mm)
5,5 8 7,2 5,5 5,5 8 7,2 5,5
16,5 25 40
63
Transair
6660 63 U1 6660 63 U2 6660 63 E4 6660 63 A1
D
63 63 63 63
C
G1/2 G1/2 G1/2 G1/2
Profile
ISO B ISO B EURO ARO
Bore (mm)
5,5 8 7,2 5,5
ISO B 6
ISO B 8
EURO 7,2
ARO 5,5
24 / 25
> The drilling tool can be used with most standard drills.
We recommend, however, that the pipe work network is drained prior to the addition of an outlet. Thanks to the lateral dismantling capability of Transair pipe and the use of quick assembly brackets, this operation can be completed very quickly (less than 7 min. for a new outlet) and guarantees the interior cleanliness of the circuit.
16,5 25 40
Transair
EA98 06 01 EA98 06 02
D
25 40
63
Transair
EA98 06 03
D
63
Transair
EA98 06 00
C
G1/2
D
13
L
330,0
E
154,0
N
30,5
Transair
6680 17 21
19,5
D
16,5 25
C1
G1/2 G1/2
C2
G1/4 G1/4
G
34 44,5
H
65 81
K
70,5 70,5
N
82 82
C1
6680 25 21
C2
16,5 25
D
66.5
Transair
6681 17 21
19,5
D
16,5 25
C1
G1/2 G1/2
C2
G1/4 G1/4
G
34 44,5
H
65 81
K
74,5 74,5
N
82 82
C1
6681 25 21
C2
C1
Transair
19,5
H
C1
G1/2
C2
G1/2
C3
G1/4
H
48
K
72,5
M
66,5
N
82
6685 21 21
C2
C3
C1
Transair
6686 21 21
H
C2
C1
G1/2
C2
G1/2
C3
G1/4
H
48
K
72,5
M
66,5
N
82
19,5
C3
26 / 27
Transair
6670 17 U1 6670 17 U2 6670 17 E4 6670 17 A1 6670 25 U1 6670 25 U2 6670 25 E4 6670 25 A1
D
16,5 16,5 16,5 16,5 25 25 25 25
Profile
ISO B ISO B EURO ARO ISO B ISO B EURO ARO
Bore (mm)
5,5 8,0 7,2 5,5 5,5 8,0 7,2 5,5
1/2 BSP parallel connection between the wall bracket and the composite safety coupler.
16,5 25
Transair
6671 17 U1 6671 17 U2 6671 17 E4 6671 17 A1 6671 25 U1 6671 25 U2 6671 25 E4 6671 25 A1
D
16,5 16,5 16,5 16,5 25 25 25 25
Profile
ISO B ISO B EURO ARO ISO B ISO B EURO ARO
Bore (mm)
5,5 8,0 7,2 5,5 5,5 8,0 7,2 5,5
1/2 BSP parallel connection between the wall bracket and the composite safety coupler. Couplers supplied with each wall bracket are ready for immediate use.
ISO B 6
ISO B 8
EURO 7,2
ARO 5,5
Transair
4089 17 00 4089 25 00
D
16,5 25
G
34,0 44,5
L
120,0 152,0
N
69,5 108,5
Z1
29,0 40,0
Z2
42,0 55,0
16,5 25
Z1 L
Z2
Model 4089 17 00 : supplied with 6 mm plug. Model 4089 25 00 : supplied with 8 mm plug.
D
16,5 25
G
34,0 44,5
L
121,0 151,7
N
69,0 108,3
Z1
29,0 40,0
Z2
42,0 55,0
Model 4099 17 00 : supplied with 6 mm plug. Model 4099 25 00 : supplied with 8 mm plug.
40
Transair
4002 40 00
D
40
G
67,0
L
205,0
N
122,0
Z
57,0
L Z Z
Transair
4002 63 00
Z1
D
63
G
91,0
L
278,0
N
185,0
Z1
84,0
Z2
98,0
63
G
D
Z2
Lockable valve
Transair
4012 63 00
D
63
G
91,0
L
278,0
N
185,0
Z1
84,0
Z2
98,0
Z1
Z2
76 100
Butterfly Valve
Transair
VR02 L1 00 VR02 L3 00
D
76 100
DN
G
145 180
M
300 270
N
250 210
E
50 56
80 100
28 / 29
> Max. working pressure : - 13 bar from -20C to +60C - 16 bar from -20C to +45C (please consult us for higher temperature requirements) > Vacuum : 98,7% (13 mbar absolute pressure) > Working temperature : -20C to +60C
C
G1/4 G3/8 G1/2 G3/4 G1
DN
E
11,4 11,4 13,5 12,5 15 17 28 22 24
F
20 20 25 31 38 48 54 66 84
H
43 43 47 58 60 77 83 95 95
L
51,5 51,5 55 57,5 69,5 81,5 95 113 132,5
M
98 98 98 122 122 153 153 162 24
10 10 15 20 25 32 40 50 61
VR03 00 10* G11/4 VR03 00 12* G11/2 VR03 00 16* G2 VR03 00 20* G21/2
H C L C
Transair
4981 10 21TR
C
R1/2
DN
F
25
H
31
L
46
M
20,5
10
Transair
4230 00 40
G
D
40
G
67
L
261
Z
85,0
Min. working pressure : 4 bar Max. working pressure : 13 bar The Transair remote control shut-off valve is supplied with a plugged vent hole. This allows venting of the downstream network, after closing the valve.
40
L
Pilot kit
Transair
H
H
145
K
106
K1
70
L
82
4299 03 01
K1
This pilot kit comprises : pneumatic ON/OFF switch (maximum 10 bar operating pressure), twin 4 mm OD polyurethane tube (length 10 m) and plastic box.
> Tools
> Practical tools for the installation and extension of Transair air pipe networks. > Presented in a carrying case, or available as separate parts.
Tool case
Transair
6698 00 04
H
315
L
290 - Chamfer tool 6698 04 01 - Deburring tool 6698 04 02 - Marking tool 6698 04 03
I
105
Transair
6698 00 03
H
315
L
290
I
105
L
230 360
H
98 155
>
Spare rotary cutter blade for Transair cutter 6698 03 01 : EW08 00 99 Spare rotary cutter blade for Transair cutter EW08 00 01 : EW08 00 02
H
120
L
80
H
134
L
155
30 / 31
25
D1
16
D2
12
H
71
Drilling tool 6698 02 02 allows the installation of 25 Transair brackets.. Can be used with all types of drill. Rotation speed : 650 rev/min.
Transair
6698 02 01
D1
22
D2
12
H
71
Drilling tool 6698 02 01 allows the installation of 40 and 63Transair brackets.. It is also used to create the 2 holes needed for double-clamp ring connectors when cutting to length 63 Transair pipe.
Transair
EW09 00 30
D1
30
D2
12
H
71
Drilling tool EW09 00 03 allows the installation of 76 and 100 Transair direct feed brackets. After drilling, it is important to de-burr and clean the pipe.
L
140
16,5 25 40
H
64
> Tools
16,5 25 40
L1
Transair
6698 04 03
H
88
L1
73
L2
33
L2
The marking tool enables connection guidelines to be marked on cut lengths of Transair pipe, These marks indicate the insertion limits of the pipe into each fitting in order to ensure good airtight connection and security of grip.
Transair
63
6698 05 03
Transair
EA98 06 00
C
G1/2
D
13
L
330,0
E
154,0
N
30,5
32 / 33
Transair
EW01 00 01 EW01 00 03
V
220 110
This case contains : 1 portable tool, 1 12V battery and battery charger.
76 100
E1 L1 E2 L2
Transair
EW02 L1 00 EW02 L3 00
D
76 100
E1
103 103
E2
52 71
L1
154 154
L2
46 46
Transair
EW03 00 01
16,5 25 40
K H1
Transair
6697 17 00 6697 25 00 6697 40 00
D
16,5 25 40
C
M6X1 M6X1 M6X1
H1
46 46 46
H
61 65,5 74,5
K
30 30 30
L
32,5 38,5 50
H L
To ensure good stability of the network, we recommend the use of at least 2 clips per pipe. Use only this clip for fixing Transair rigid pipe, all other types of clip are to be avoided.
63
Transair
D H L H1
D
63
C
M10X1,5
H1
90
H
127,5
K
30
L
73,5
6697 63 00
To ensure good stability of the network, we recommend the use of at least 2 clips per pipe. Use only this clip for fixing Transair rigid pipe, all other types of clip are to be avoided.
76 100
Transair
ER01 L1 00
D
D
76 100
C
M8 / M10 M8 / M10
ER01 L3 00
To ensure good stability of the network, we recommend the use of at least 2 clips per pipe. Use only this clip for fixing Transair rigid pipe, all other types of clip are to be avoided.
Spacer
16,5
H
Transair
D
D
11
H
49,5
H1
44
K
34
L
33
6697 00 03
H1
63
This spacer, in association with a Transair pipe clip, allows consistent alignment of pipes when different diameters of pipe are run concurrently in the same line.
63
>
40
46mm 46 mm 44mm 44 mm
m 90 90m mm
C2
C2
M8X1,25 M10X1,5
E
16 16
F
13 13
H
30 30
6697 00 01 6697 00 02
C1
The use of this adaptor facilitates the suspension of Transair with M8 or M10 threaded rod.
34 / 35
U-channel
Transair
6699 01 01
L H L1
H
25
L(m)
2
L1
25
Transair
H
H
106
L
40
6699 01 02
This set comprises : 1 bracket 1 fixing bolt & nut 1 nut 1 rail profile end cap
C
M10
H
35
K
20
L
50
6699 01 03
This set comprises : 1 U-channel threaded bracket + M10 threaded rod 1 washer 1 locknut
H
49
L
41
N
25
Supplied with one 8x25 needle bolt for each suspension arm.
H N N L
11 mm maxi.
Horizontal assembly
Vertical assembly
16,5 25 40
Transair
6699 02 01 6699 02 02 6699 02 03 6699 02 04 6699 02 05 6699 02 06
H
44 46 54 66 44 46
K
1,5 to 3 3 to 8 8 to 14 14 to 20 1,5 to 3 3 to 8
T
M6 M6 M6 M6 M10 M10
63
76 100
Transair
6699 03 01
T2
10,7
T
6,5
T1
10,7
K
18
16,5 25 40
36 / 37
Transair
6699 10 01
H
200
K
60
N
37
Transair
6699 10 02
H
200
K
60
N
30
L 10 x 30
Transair
6699 10 03
L
140
M
22
16,5 10 m 25 40
Transair
H
D
11,5
Max. Pressure(bar)
12
H
251
L
300
6698 10 01
Enclosed case Hose clutch with free return Outlet connection G1/4 male
16 m 1 63
Transair
H
D
12
Max. Pressure(bar)
15
H
251
L
390
6698 10 02
Enclosed case Hose clutch with free return Outlet connection G1/4 male
76 100 21 m 16,5 25 40
Transair
H
D
13,5
Max. Pressure(bar)
20
H
430
L
600
6698 11 01
Open case with roller guides Hose outlet with free return Outlet connection G1/2 male
Pivoting bracket
Transair
6698 11 98
Blowgun
76 100
DN
Transair
EA59 00 13
C
G1/4
DN
H
125,5
L
223,0
3,5
38 / 39
Polyurethane recoil tubing > Perfectly suited to installations requiring flexibility in a reduced space. > Fluid : compressed air > Max. working pressure at 20C : 10 bar
L3
2m
L1 L2
out. in.
6 8 10 12 4 5 7 8
C
R1/4 R1/4 R1/4 R3/8
L1
300 500 500 500
L2
100 100 100 100
L3
630 780 780 780
32 42 62 65
L3
Transair
out.
6 8 10 12
in.
4 5 7 8
C
R1/4 R1/4 R1/4 R3/8
L1
300 500 500 500
L2
100 100 100 100
L3
850 1000 1000 990
32 42 62 65
4m
1471U06 04 13TR
L1 L2
L3
Transair
out.
8 10 12
in.
5 7 8
C
R1/4 R1/4 R3/8
L1
500 500 500
L2
100 100 100
L3
1230 1140 1190
42 62 65
6m
L1 L2
out.
12 14 16 20 24
in.
6 8 10 13 16
25 m
L H
L1
D
D
12 14 16 20 24
H
12 12 12 12 12
K
9 9 9 9 9
L
21 21 24 24 24
L1
13 13 13 13 13
For heavy duty or dusty applications, we recommend the use of the automatic metal couplers (page 42/43)
ISO B 5,5 mm
Safety
C
G1/4 G3/8 G1/2
C
G1/4 G3/8 G1/2
D
6 8 10
ISO B 8 mm
Safety
C
G1/4 G3/8 G1/2
C
G1/4 G3/8 G1/2
D
8 10 13
EURO 7,2 mm
Safety
C
G1/4 G3/8 G1/2
C
G1/4 G3/8 G1/2
D
8 10 13
ARO 5,5 mm
Safety
C
G1/4 G3/8 G1/2
C
G1/4 G3/8 G1/2
D
6 8 10
Safety
ISO B 5,5 mm ISO 6150 B AFNOR NF 49-053 US.MIL.C4109 CEJN 310 RECTUS 23-24
Pressure loss in bar
ISO B 5,5 mm
ARO 5,5 mm ARO 210 CEJN 300 ORION 44510 PARKER 50 RECTUS 14-22
Pressure loss in bar Flow in Nm3/h To convert Nm3/h to cfm, use a coefficient of 0.588
ISO B 8 mm
40 / 41
Transair composite automatic couplers comply with worldwide ISO 4414 and European EN 983 safety standards. Disconnection is by a double twist of the sleeve a safety feature that breaks deliberately with common practice in order to avoid accidental disconnection.
1st rotation in direction of the arrow : circuit rapidly flushed out, probe side. 2nd rotation in direction of the arrow : safe disconnection of body and probe.
ISO B 5,5 mm
C
G1/4 G3/8 G1/2
C
G1/4 G3/8 G1/2
D
6 8 10
ISO B 8 mm
C
G1/4 G3/8 G1/2
C
G1/4 G3/8 G1/2
D
8 10 13
EURO 7,2 mm
C
G1/4 G3/8 G1/2
Transair
CA86 E4 02 CA86 E4 03 CA86 E4 04
C
G1/4 G3/8 G1/2
D
8 10 13
ARO 5,5 mm
C
G1/4 G3/8 G1/2
C
G1/4 G3/8 G1/2
D
6 8 10
Probe adaptor
Transair
CA90 U1 01
Pressure loss in bar
EURO 7,2 mm
Profile
ISO C6 PCL
Pressure loss in bar
Profile
to to ISO B6 ISO B6
CA90 U1 03
CA90 U1 01 CA90 U1 03
ARO 5,5 mm
> Vacuum :
- models ISO B 6 and 8 mm safety version: 98,7% (13 mbar absolute pressure) - models ISO C 6, 8 and 11 mm safety version : 98,7% (13 mbar absolute pressure) - models ISO C 6 mm single shut-off version : 98,7% (13 mbar absolute pressure)
ISO B 6 8 mm
Safety
Transair
9D05 09 13P4 9D05 09 17P4 9D05 09 21P4 9D05 10 13P4 9D05 10 17P4 9D05 10 21P4
Transair
9D14 09 13P4 9D14 09 17P4 9D14 09 21P4 9D14 10 13P4 9D14 10 17P4 9D14 10 21P4
DN
D
6 8 10 8 10
DN
ISO C 6 8 11 mm
Safety
D
6 8 9 13 10 13 13 16
DN
9D14 01 13P483 G1/4 5,5 9D14 01 17P483 G3/8 5,5 9D14 01 21P483 G1/2 5,5 9D14 02 13P483 G1/4 9D14 02 17P483 G3/8 9D14 02 21P483 G1/2 8 8 8
9D01 01 13P483 G1/4 5,5 9D01 01 17P483 G3/8 5,5 9D01 01 21P483 G1/2 5,5 9D01 02 13P483 G1/4 8 9D01 02 17P483 G3/8 8 9D01 02 21P483 G1/2 8
ISO C 6 mm
Single shut-off
Transair
DN
DN
D
10
DN
9D01 01 13P183 G1/4 5,5 9D01 01 17P183 G3/8 5,5 9D01 01 21P183 G1/2 5,5
9D14 01 10P183 G1/8 5,5 9D14 01 13P183 G1/4 5,5 9D14 01 17P183 G3/8 5,5
5,5
Safety
ISO B 6 mm & 8mm ISO 6150 B US.MIL.C4109 CEJN 310-430 RECTUS 23-24-30
ISO C 6mm, 8mm & 11mm ISO 6150 C NF E49-053 CEJN 29-381 RECTUS 18-84
m3/h 100 80 60
Safety
150
100
40
50
20
bar bar
42 / 43
> Working temperature : - models ISO B 6, 8 mm safety version : from -20C to +90C - models ISO C 6, 8 and 11 mm safety version : from -20C to +60C - models ISO C 6 mm single shut-off version : from -20C to +60C > Max. working pressure : - models ISO B 6 and 8 mm safety version : 16 bar - models ISO C 6, 8 and 11 mm safety version : respectively 12, 10 and 8 bar - models ISO C 6 mm single shut-off version : 10 bar
ISO B 6 8 mm
Transair
9084 23 13TR 9084 23 17TR 9084 30 13TR 9084 30 17TR 9084 30 21TR
DN
DN
Transair
9085 23 06TR 9085 23 08TR 9085 23 10TR 9085 30 08TR 9085 30 10TR 9085 30 13TR
D
6 8 10 8 10 13
DN
Transair Transair
D
6 8 10 13 6 8 10 13 8 13 16
DN
DN
Transair
DN
ISO C 6 8 11 mm
9A87 01 10X099 G1/8 5,5 9A87 01 13X099 G1/4 5,5 9A87 01 17X099 G3/8 5,5 9A87 02 13X099 G1/4 9A87 02 17X099 G3/8 9A87 02 21X099 G1/2 8 8 8
9A86 01 10X099 9A86 01 13X099 9A86 02 13X099 9A86 02 17X099 9A86 02 21X099 9A86 03 17X099 9A86 03 21X099
G3/8 11 G1/2 11
9A94 01 06X099 9A94 01 08X099 9A94 01 10X099 9A94 01 13X099 9A94 02 06X099 9A94 02 08X099 9A94 02 10X099 9A94 02 13X099 9A94 03 08X099 9A94 03 13X099 9A94 03 16X099
Single shut-off
m3/h 100 80 60 40 20
m3/h 100 80 60
m3/h 200
m3/h 200
m3/h 400
m3/h 400
150
150
300
300
Single shut-off
100
40
100
200
200
50
20
bar bar
50
100
100
20
06
17
28
0 5
1 6
2 7
3 8
06
17
28
bar
0 5
1 6
2 7
3 8
bar
06
17
28
bar
bar
bar
C1
R1/4 R1/4 R3/8 R1/4 R3/8 R1/2 R1/2 R3/4 R3/4 R1 R1 R11/4 R11/4 R11/4 R11/2 R11/2 R11/2 R2 R2 R21/2
C2
R1/4 R3/8 R3/8 R1/2 R1/2 R1/2 R3/4 R3/4 R1 R1 R11/4 R11/4 R11/2 R2 R11/2 R2 R21/2 R2 R21/2 R21/2
F
14 17 17 22 22 22 27 27 34 34 42 42 48 60 48 60 75 60 75 75
L
27 27,5 28 30,5 31 33,5 37,5 40 43 45,5 40,5 43 44 49 44 49 52,5 52 54,5 58
EF00 04 06 EF00 00 06 EF00 06 08 EF00 00 08 EF00 08 10 EF00 00 10 EF00 10 12 EF00 10 16 EF00 00 12 EF00 12 16 EF00 12 20 EF00 00 16 EF00 16 20 EF00 00 20
C1
C2
Transair
EF02 01 02 EF02 00 02
L
C1
G1/8 G1/4 G1/8 G1/4 G3/8 G1/4 G3/8 G1/2 G1/2 G3/4
C2
G1/4 G1/4 G3/8 G3/8 G3/8 G1/2 G1/2 G1/2 G3/4 G3/4
F
17 17 22 22 22 27 27 27 30 30
L
19,5 22 20 23 24 27 27,5 30 30 32
C2 F
44 / 45
C1
R1/8 R1/8 R1/4 R1/4 R1/4 R3/8 R3/8 R1/2 R1/2 R1/2 R3/4 R3/4 R1 R1 R11/4 R11/4 R11/4 R11/2 R11/2 R11/2 R2 R2 R21/2
C2
G1/4 G3/8 G1/4 G3/8 G1/2 G3/8 G1/2 G1/2 G3/4 G1 G3/4 G1 G1 G11/4 G11/4 G11/2 G2 G11/2 G2 G21/2 G2 G21/2 G21/2
E1
6 6 8 8 8 9 9 10 11,5 11,5 13 13 15 15 17,5 17,5 17,5 17,5 17,5 17,5 20,5 20,5 23
E2
11,5 11,5 11,5 11,5 15 11,5 15 15 10,5 12 10,5 12,5 12,5 14 14 15 16 15 16 19 16 19 19
F
17 22 17 22 27 22 27 27 29 36 29 36 36 45 45 52 64 52 64 80 64 80 80
L
14 14,5 14 14,5 18 14,5 18 18 24 26,5 25,5 28 30 32 34,5 35,5 36,5 35,5 36,5 39,5 39,5 42,5 45
EF06 04 06 EF06 04 08 EF06 00 06 EF06 06 08 EF06 00 08 EF06 08 10 EF06 00 10 EF06 10 12 EF06 10 16 EF06 00 12 EF06 12 16 EF06 12 20 EF06 00 16 EF06 16 20 EF06 00 20
C1
R1/4 R3/8 R3/8 R1/2 R1/2 R3/4 R3/4
C2
G1/8 G1/8 G1/4 G1/4 G3/8 G3/8 G1/2
F
14 17 17 22 22 27 27
L
16 16,5 16,5 19,5 19,5 23,5 23,5
C1
Transair
C
C
G1/4 G3/8 G1/2 G3/4
E
11 11,5 14 15
G
17 21 26 31
J
13 17 21 27
L
25,5 28 33,5 36,5
Transair
EF13 00 02 EF13 00 03 EF13 00 04 EF13 00 06
C1
R1/4 R3/8 R1/2 R3/4
C2
G1/4 G3/8 G1/2 G3/4
E
11 11,5 14 15
G
17 21 26 31
H
23,5 26 31 35
J
13 17 21 27
L
25,5 28 33,5 36,5
C1
Transair
EF14 00 02 EF14 00 03
C
C
R1/4 R3/8 R1/2 R3/4
H
23,5 26 31 35
J
13 17 21 27
L
23,5 26 31 35
EF14 00 04 EF14 00 06
Transair
EF10 00 02
F C E H
C
G1/4 G3/8 G1/2
E
11 11,5 14
F
17 20 25
H
14 16 19
EF10 00 03 EF10 00 04
C2
90
C2
E
C2
G1/2
E
14
F
25
H
19
H
C1
EF11 00 04
46 / 47
L 2
Transair
EF15 00 02
E
H
C
G1/4 G3/8 G1/2 G3/4
E
11 11,5 14 15
G
17 21 26 31
H
25,5 28 33,5 36,5
J
13 17 21 27
L/2
25,5 28 33,5 36,5
C
J
Transair
EF16 00 02
E H
C1
R1/4 R3/8 R1/2 R3/4
C2
G1/4 G3/8 G1/2 G3/4
E
17 11,5 14 15
G
17 21 26 31
H
23,5 26 31 35
J
13 17 21 27
L/2
25,5 28 33,5 36,5
L 2
C2
G1/4 G3/8 G1/2 G3/4
E
11 11,5 14 15
G
17 21 26 31
H
23,5 26 31 36,5
J
13 17 21 27
L/2
25,5 28 33,5 36,5
C2 H J
C1
D
6 6 8 8 10 10 10 13 13 13 16 16
C
G1/8 G1/4 G1/4 G3/8 G1/4 G3/8 G1/2 G1/4 G3/8 G1/2 G3/8 G1/2
E
6 8 8 9 8 9 10 8 9 10 9 10
F
12 17 17 19 14 19 22 17 19 24 19 24
L
20 21 21 21 20 20 20 21 22 25 21 25
Supplied with captive sealing washer. Ideally suited for use with Transair PVC hose.
> Air quality at FRL inlet : dry, damp, lubricated > Transair FRL products are guaranteed silicone free
> Chemical resistance to compressor oils To convert Nm3/h to cfm use a coefficient of 0.588
Filter regulator
Transair
6700 00 13 6700 00 21
C
G1/4 G1/2
Recommended flow
Bowl capacity
TC at 10 bar
Filtration
Associated gauge
33m3/h 114m3/h
22cm3 50cm3
16 bar 16 bar
8 bar 8 bar
0C to +50C 0C to +50C
30 m 30 m
6798 00 05 6798 00 06
Pressure regulator
Transair
6701 00 13 6701 00 21
C
G1/4 G1/2
Recommended flow
Temperature
Associated gauge
33m3/h 114m3/h
16 bar 16 bar
8 bar 8 bar
0C to +60C 0C to +60C
6798 00 05 6798 00 06
Transair
6707 00 13 6707 00 21
C
G1/4 G1/2
Recommended flow
Bowl capacity
TC at 10 bar
Filtration
Associated gauge
33m3/h 114m3/h
22cm3 50cm3
16 bar 16 bar
8 bar 8 bar
0C to +50C 0C to +50C
30 m 30 m
6798 00 05 6798 00 06
48 / 49
All these products can be easily connected to Transair compressed air pipework systems using the following Transair stud fittings : -6605 17 13 for G1/4 port -6605 17 21 or 6605 25 21 for G1/2 port
Transair
6708 00 13 6708 00 21
C
G1/4 G1/2
Recommended flow
Bowl capacity
TC at 10 bar
Filtration
33m3/h 114m3/h
22cm3 50cm3
16 bar 16 bar
8 bar 8 bar
0C to +50C 0C to +50C
30 m 30 m
Filter separator
Transair
6702 00 13 6702 00 21
C
G1/4 G1/2
Recommended flow
Bowl capacity
TC at 10 bar
Filtration
33m3/h 114m3/h
22cm3 50cm3
16 bar 16 bar
8 bar 8 bar
0C to +50C 0C to +50C
30 m 30 m
Transair
6703 00 13 6703 00 21
C
G1/4 G1/2
TC at 10 bar
Oil capacity
16 bar 16 bar
8 bar 8 bar
0C to +50C 0C to +50C
45cm3 112cm3
Automatic drain
Transair
6706 00 21
C
G1/2
Transair
6704 00 13 6704 00 21
C
G1/4 G1/2
Recommended flow
Min. pressure
Max. pressure
33m3/h 114m3/h
0 bar 0 bar
16 bar 16 bar
Transair
6705 00 13 6705 00 21
C
G1/4 G1/2
To be used when assembling 2 elements front and rear entry G1/8 and G1/4. Can also be used when oil-free air is required install prior to lubricator
50 / 51
Pressure gauge
Transair
6798 00 05 6798 00 06
C
G1/8 G1/4
Face mm
40 50
Associated FRL
6700 00 13 - 6701 00 13 - 6707 00 13 6700 00 21 - 6701 00 21 - 6707 00 21
To be mounted on the front face of filter regulator 6700, regulator 6701 and filter regulator lubricator set 6707.
Protection bowl
Transair
6798 00 07 6798 00 08
C
G1/4 G1/2
To be used with filter regulator, filter separator and filter regulator lubricator set. Equipped with snap mounting.
Mounting brackets
Transair
6798 00 01 6798 00 02
C
G1/4 G1/2
For wall or machine fixing. Screws supplied Wall fixing-to-centre : 46 mm (compatible with Transair fixing clips).
Assembly kit
Transair
6798 00 03 6798 00 04
C
G1/4 G1/2
Transair
6699 04 01
H
2500
P
60
Transair
6699 04 02
L
H
2450
H1 (maxi)
600
L
100
Transair
6699 04 60
D
14
C
G1/4 G1/2
F
24 24
H
62 75,5
H1
29,5 33
H2
8,5 18,5
L
136,5 137
L1
109,5 103
L2
20 23
6699 04 60 01 14
Transair
6699 04 63
D
14
H
82,5
H1
29,5
H2
29
L
136,5
L1
109,5
L2
20
M
69,5
52 / 53
40
H2 H
Transair
6699 04 64
D
14
F
24
H
28
H1
29,5
H2
44,5
L
136,5
L1
109,5
L2
20
D L2 L1 L H1
29 H2
4
Transair
H
H
82
H2
25
L
124,5
6699 04 65
Plug
L
Transair
G
D
14
G
16
L
49
L1
23,5
3126 14 00TR
L1
Transair
H E C F
D
14
C
G3/8
E
14
F
22
H
42,5
3114 14 17TR
To connect module stem to braided PVC hose for unit air supply, using hosetail adaptor EF26.
EASIER
HANDLING
Pipes and fittings are supplied ready for immediate installation > NO PREPARATION REQUIRED Quick assembly - no need to weld, glue or crimp > TIME SAVING Easy to assemble > NO IN-DEPTH TRAINING REQUIRED
RESISTANCE
TO
HIGH
> thermal variations > U.V. > compressor oil carry over
ADAPTABLE
> Dismountable and reusable components
54 / 55
Essential instructions
Installation instructions Sound engineering practice for the optimization of an air pipework system
56 57
Aluminium pipe
General Aluminium pipe section
58 60
64 66 69 74/75
76 77 80
Flexible hose
General Network connection Dos / Donts
82 83 86
87
Fixture accessories
Attachments Supporting a Transair system
88 90
Practical data
Z dimensions Expansion / contraction Conversion charts
94 95 100 102
Transair in situ
> General
Prior to the installation of a Transair compressed air distribution system, the installer should ensure that the installation area complies with any regulations applicable to areas exposed to explosive hazards (in particular the effect of static electricity in a silo area). Transair should be installed downstream of the compressed air receiver, or after the dryer. Flexible Transair hose can be installed at the start of the system in order to eliminate any sources of vibration and to facilitate maintenance operations. When maintaining or modifying a Transair system, the relevant section should be vented prior to the commencement of any work. Installers should use only Transair components and accessories, in particular Transair pipe clips and fixture clamps. The technical properties of the Transair components, as described in the Transair catalogue, must be respected.
56 / 57
> Sound engineering practice for the optimization of an air pipework system
> When installing a Transair system, the work should be performed in accordance with good engineering practice.
> Bends and bypasses represent sources of pressure drop To avoid excessive pressure loss, use modular consoles to offset the network and to bypass obstacles. Keep in-line pipe diameter reductions to a minimum.
> Maintain a consistent level of good quality air by use of adequate filtration at the compressor outlet.
> The diameter of the pipe will influence pressure drop and the operation of point-of-use equipment Select the diameter according to the required flow rate and acceptable pressure drop at the point of use.
> General
16,5
25
40
> Presentation
Pipe pre-drilled at each end with two 22 mm diameter holes, deburred and chamfered
Transair aluminium pipe is supplied ready for use. No particular preparation (cutting, deburring, chamfering, etc.) is required. Thanks to the rigidity of Transair aluminium pipe, temperature-related expansion / contraction phenomena are reduced to a minimum. The Transair network retains its straightness, and hence its performance, over time (reduction of pressure drop caused by surface friction). Transair aluminium pipe is calibrated and fits perfectly with all Transair components. Each connection is automatically secured and the seal is optimized. The use of Transair aluminium pipe minimises corrosion to the internal surface (self-protection of the pipe by the formation of alumina oxide).
Transair aluminium pipe has a protective lacquer coating (QUALICOAT certified) and is thus protected from external aggression. It s colour allows the network to be immediately identified and gives a clean and aesthetic overall appearance. Standard colours available: blue (RAL 5012/BS1710) grey (RAL 7001) (please contact us for other colours) Transair aluminium pipe is available in 6 diameters and 2 lengths: 3 metres and 6 metres (please contact us for other lengths).
> Applications
Transair 16.5 - 25 - 40 - 63 - 76 - 100 aluminium pipe has been specially designed for the creation of primary and secondary networks for compressed air, vacuum and neutral gases (argon, nitrogen) - please contact us for other fluids
58 / 59
> Marking
Pipe calibration is a guarantee of secure connection and sealing Type of pipe
Manufacturing batch
The transported fluid can be instantly identified by the colour of the pipet Blue pipe Grey pipe > Identification compressed air network vacuum network
This identification may also be done by applying adhesive labels directly onto the pipe
Connection indicator
Locator
Drilling locators are used to correctly position Transair brackets onto the pipe. There are two locators on each pipe. The second locator is used to position a second bracket perpendicular to a first bracket.
> 16,5 25 - 40
> Tools
Pipe cutter for aluminium pipe ref. 6698 03 01 Chamfer tool for aluminium pipe ref. 6698 04 01 Deburring tool for aluminium pipe ref. 6698 04 02 Marking tool for aluminium pipe ref. 6698 04 03
2 1
> Procedure
1 - Cutting the pipe : - place the pipe in the pipe cutter - position the blade onto the pipe - rotate the pipe cutter around the pipe while gently tightening the wheel.
2 - Carefully chamfer the outer edges. 3 - Also deburr the inner end of the pipe 4 - Trace the connection indicator using the marking tool.
The insertion lengths for 16,5 - 25 - 40 connectors are 25 mm, 27 mm and 45 mm respectively, with the exception of the end cap, ref. 6625, for which the insertion lengths are of 39 mm, 42 mm and 64 mm respectively.
60 / 61
> 63
File
> Tools
Drill
2 3
> Procedure
1 - Cutting the pipe : - place the pipe in the pipe cutter - position the blade on the pipe - rotate the pipe cutter around the pipe while gently tightening the wheel. 2 - Carefully chamfer the outer edges. 3 - Also deburr the inner end of the pipe
4 - Drill the two clamp holes using the drilling jig (6698 01 02) and the 22 mm drilling tool (6698 02 01). Loosen the jig, release the pipe, then deburr both holes. Ensure that all outer and inner surfaces are smooth and clear of swarf and potential sharp edges.
> 76 - 100
> Tools
Pipe cutter for aluminium pipe ref. EW08 00 01 File Portable tool kit ref. EW01 00 01 (220V) or EW01 00 03 (110V) Pipe forming jaw set ref. EW02 L1 00 ( 76) or EW02 L3 00 ( 100)
1 - Cutting the pipe : - place the pipe in the pipe cutter - position the blade on the pipe - rotate the pipe cutter around the pipe while gently tightening the wheel. 3
2 Carefully deburr and chamfer the outer and inner edges of the pipe with a file.
> Procedure
>
>
Open the retaining pin at the front of the machine by pressing the jaw release button*
62 / 63
>
Manually open the jaws of the clamp and insert the aluminium pipe into the clamp as far as it will go.
Release the jaws. Press the trigger and crimp the tube until a snap sound is heard.
> Procedure
>
Re-open the two jaws to remove the pipe and rotate the pipe slightly.
Renew the operation until the required minimum number of lugs for each diameter is achieved.
76
100
> General
> 16,5 25 40
Pipe
16,5, 25 and 40 connectors secure instantly to Transair aluminum pipe. Simply insert the pipe into the connector up to the connector inser tion mark.
The internal gripping ring is then automatically secured and the connection is complete.
> 63
63 connectors are quickly secured to Transair aluminum pipe by means of a double clamp which makes the connector
fully integrated with the pipe. Connection is achieved by simply tightening the nut.
Retaining screw
Pipe
> 76 100
Cartridge Clamp
76 and 100 clamps secure instantly to Transair aluminium pipe. Simply position the formed pipe within the Transair cartridge, which acts as a
seal. Close the Transair clamp to secure the connection and finally tighten the 4 retaining screws.
64 / 65
There are important visual markings on the bodies and nuts of Transair 16,5, 25 and 40 connectors. These are represented by solid and empty arrows and indicate the optimum torque. When assembling Transair connectors,
the nuts are tightened to a pre-defined torque on the body of the connector. This torque guarantees the seal and safety of each connection.
There is no need to loosen the nuts prior to joining 16,5, 25 and 40 connectors to Transair aluminum pipe.
Before using 16,5, 25 or 40 connectors, ensure that these arrow marks are correctly aligned with each other.
Connection
> 16,5 25 40
Disconnection
Simply insert the pipe into the connector up to the connection mark. To disconnect, unscrew the nut by one half turn and remove the pipe.
Lateral dismantling: see page 72 of this guide.
The insertion length is greater for end caps than for other Transair connectors. The connection mark should be applied to the pipe by means of a marker and tape measure, using the following values:
66 / 67
Connection
1 2
5 6
> 63
Disconnection
1 - Unscrew one of the connector nuts and fit over the pipe. 2 - Position the double clamp ring in the appropriate housings (2 holes at the end of the pipe). 3 - Bring the nut towards the body, that has been previously positioned at the end of the pipe, until it stops against the double clamp. Lateral dismantling: see page 72 of this guide.
4 - Tighten the nut.by hand 5 - Bring the two pipes together. 6 Complete the assembly by 1/2 rotation with Transair tightening spanners ref. 6698 05 03. 7 - To disconnect, perform the same operations in reverse order.
Connection
1 2
> 76 100
1 - Slip the cartridge over the end of the first pipe fully up to the shoulder. 2 - Bring the second pipe to the cartridge and slide fully up to the shoulder. 3 - Position the clamp over the cartridge / pipe assembly.
4 - Hand tighten the pre-fitted screws with an Allen key. 5 - Pull the pipes fully back towards the outside of the clamp. 6 - Fully tighten the clamp screws. tightening torque mini:10Nm Maximum tightening torque : final closure of clamps
For effective clamp sealing, screw tightening should be performed on alternate sides of the clamp as shown below :
1
4
68 / 69
76
100
63
40
25
16,5
Minimum pipe centre-to centre mounting distances for 76 and 100 tees
D1(mm) D2(mm) A(mm) Bmini(mm) 100 100 90 470 100 76 80 410 100 63 90 327 100 40 46 225 100 25 46 215 100 16,5 46 200 76 76 80 420 76 63 90 314 76 40 46 212 76 25 46 202 76 16,5 46 187
D1
B mini
Minimum pipe centre to centre mounting distances for 76 and 100 brackets
D1(mm) D2(mm) A(mm) Bmini(mm) 100 25 46 250 76 25 46 240
D2 A
70 / 71
1 3
2 4
1 - Loosen the 2 nuts. 2 - Slide them along the pipe on either side of the connector. 3 - Remove the body of the connector, together with the nuts. Slide on the ball valve nuts.
4 - Position the body of the tee between the 2 pipes so that the empty and solid arrows are facing each other 5 - Re-tighten the nuts until the empty and solid arrows are aligned with each other.
> 16,5 25 40
Loosen the nuts located on the side of the pipe to be removed and slide them along the pipe. Then remove the pipe
> 63
1 - Loosen the connector nuts on the ends of the pipe to be removed 2 - Slide them along the pipe. 3 - Remove the clamp rings from their housings.
4 - Slide the clamps and the connector body along the pipe which is to be removed. 5 - Repeat the operation at the other end of the pipe and laterally remove the pipe, complete with the assembly components.
72 / 73
> Application
Assembled by simple and fast connection to aluminium pipe, the Transair 40 remote shut-off valve allows network supply to be rapidly and safely opened and closed either at ground level or by remote control. The Transair remote shut-off valve thus guarantees : Personal safety, by eliminating all hazards related to working at heights. Servicing speed, by removing the need for special access equipment (ladder, platform etc) Single acting valve - normally closed. For compressed air networks : the valve control pressure can be taken upstream of the isolating valve, with no external power supply. Control is per formed through the control unit connected to the valve by means of a push-in connector.
For vacuum networks : a compressed air supply external to the control unit is required, and the corresponding valve por t must be closed in order to prevent loss.
> Dos
> Connection
> Carefully chamfer and deburr the pipe after cutting or drilling
74 / 75
> Donts
> General
The easy addition of a new drop or bypass onto an existing length of pipe is an important consideration for any air pipework system. Transair quick assembly brackets are designed for this very purpose, without the need to cut the pipe. A swans neck built into the brackets retains condensate water in the main line. Thanks to its small size, the Transair quick assembly bracket facilitates new additions in the tightest places and can be
Vertical Drop
25 - 40
63
For 25 and 40 Transair quick assembly brackets, the pipe centre to wall distance is equal to the bracket centre to wall distance, i.e. 46mm. For 63 Transair quick assembly brackets the pipe centre to wall distance is 90mm and the 25 and 40 bracket centre distance is 46mm.
Furthermore, Transair clips should be fitted at a distance of at least 150mm from a quick assembly bracket in order to allow for the expansion / contraction of aluminium pipe
76 / 77
> To 25 40 pipe
> Procedure
1 - Mark the pipe at the desired position for the bracket, using the same locator mark when several takeoff points need to be aligned uniformly. Place the drilling jig ref. 6698 01 01 in a vice or on the floor. To drill a 40 hole, remove the retaining bolt in the jig using an allen key and place the pipe in the jig. The locator mark on the pipe should be aligned with the appropriate guide marks on the side of the jig. Two guide lines on either side of the jig provide a rapid indication of whether the pipe is correctly positioned (the guide lines match the locator marks on the pipe). Close the jig and drill a hole using the appropriate drilling tool : 25 : 16 hole > ref. 6698 02 02 drilling tool 40 : 22 hole > ref. 6698 02 01 drilling tool Recommended rotation speed: 650 rpm NB : drill without lubrication. 2 - Release the pipe, deburr and remove any swar f and the cut circular piece of pipe. Repeat the operation for the number of brackets that you wish to fit. 3 - Position the quick assembly bracket using its location pin 4 - Tighten the nut. Remark : the jigs second drilling guide corresponds to the minimum distance for fitting two adjacent brackets or a double hole quick assembly bracket ref 6662 25 00 / 6662 40 00
> On 63 pipe
Drill
4 2 3
> Procedure
1 - Mark the pipe at the desired position for the bracket. The mark should be placed on one of the locator marks so that multiple brackets are correctly aligned, when several take-off points are required. Place the 63 drilling jig in a vice or on the floor and place the pipe in the jig. Ensure that the line marked on the pipe is centred within the drilling guide: 2 marks on either side of the jigs upper side provide a rapid indication of the pipes positioning. Tighten the locking clamp to secure the pipe and drill using the 22 drilling tool. [Recommended rotation speed: 650 rpm] NB: drill without lubrication. 2 - Loosen the locking clamp and release the pipe, deburr and remove any swarf and the cut circular aluminum piece of pipe. Repeat the operation for the number of brackets that you wish to fit. 3 - Position the quick assembly bracket using its location hole. 4 - Tighten the nut.
78 / 79
Drill
> Procedure
3 4
1 - Drill the aluminum pipe at the desired position using drilling tool ref. EW09 00 30 2 - Carefully deburr the pipe
3 - Position bracket ref. RR61 and fully tighten the 2 screws 4 - Screw on male adapter ref. 6621 25 34
NB: adapter ref. 6621 25 34, in combination with bracket ref. RR61, is used to create a 25 take-off point from 76 or 100 pipe
80 / 81
Tool body
Use the under pressure drilling tool to fit a bracket to an existing pressurised system. This can be simply done with use of a standard drill
> Procedure
1 - Position the pressurised system bracket and fully tighten the 2 screws. 2 - Screw the assembly onto the ball valve. Ensure that the valve is open.
3 - Screw the drilling tool onto the ball valve. Drill fully. 4 - Remove the drill and close the ball valve immediately. Dismantle the drilling tool.
> General
Transair flexible hose can be easily connected to other Transair components and can be rapidly installed without prior preparation or cutting. Thanks to is small bend radius, it requires minimum space and avoids mechanical stress within the network. Robust, Transair flexible hose is resistant to both compressor oils and to fire
> Applications
(mm)
25 25 25 25 25 25 40 40 40 40 40 40 63 63 63 63 63 76 76 100 100
Length (mm)
570 1500 2000 570 1500 2000 1150 2000 3000 950 2000 3000 1400 3000 4000 3000 4000 1500 2000 2000 3000
Transair
1001E25 00 01 1001E25 00 03 1001E25 00 04 1001E25V00 01 1001E25V00 03 1001E25V00 04 1001E40 00 02 1001E40 00 04 1001E40 00 05 1001E40V00 07 1001E40V00 04 1001E40V00 05 1001E63 00 08 1001E63 00 05 1001E63 00 06 1001E63V00 05 1001E63V00 06 FP01 L1 01 FP01 L1 02 FP01 L3 01 FP01 L3 03
Rmini (mm)
100 100 100 75 75 75 400 400 400 160 160 160 300 650 650 250 250 350 350 450 450
> Safety
In order to avoid the risk of whiplash accidents Transair recommends the use of anti-whiplash straps, placed on either side of the connection. If Transair flexible tube is exposed to tear, the anti-whiplash assembly prevents it from snaking (safety device in accordance with ISO 4414 standard).
82 / 83
> 16,5 25 40
1 3 4
3 - Move the swaged end of the hose onto the exposed stud thread. 4 - Tighten the nut.
3 - Move the swaged end of the hose onto the connector thread. 4 - Tighten the nut.
3 - Move the swaged end of the hose onto towards the elbow thread 4 - Tighten the nut.
> 63
1 3 2 4 5
1 - Loosen the nut on the stud fitting and remove it 2 - Place the nut over the swaged end of the flexible hose 3 - Place the pipe connector clamps in the housings on the hose.
4 - Slide the nut forward to the end of the flexible hose ,and assemble onto the male thread. 5 - Tighten the nut using the 63 spanner set
1 - Loosen the nut on the connector and remove it 2 - Fit it over the swaged end of the flexible hose 3 - Place the pipe connector clamps in the housings on the hose.
1 3
4 - Slide the nut forward to the end of the flexible hose, until it touches the clamps. 5 - Tighten the nut using the 63 spanner set
> Using a 90 elbow 1 - Loosen the nut on the elbow and remove it 2 - Fit it over the swaged end of the flexible hose 3 - Place the elbow clamps in the housings on the hose 4 - Slide the nut forward to the end of the flexible hose, until it touches the clamps 5 - Tighten the nut using the 63 spanner set
84 / 85
> 76 - 100
> Dos
> Donts
86 / 87
> Installation
1
1
> Columns
3 1 - Fix the bracket to the wall 2 - Clip on the column 3 - Screw the base to the floor 1 - Fix the base to the floor
2 - Release the cylinder to lock the column in position PVC tube 1025V Tailpiece adaptor for PVC tube EF26 Female stud fitting ref. 3114 14 17TR 1 2
> Modules
3 Plug ref. 3126 14 00TR
The Transair fixing clip is the basic component for mounting pipe when installing. 16,5 25 40 63 Transair aluminium networks. Only this clip should be used since it since it allows expansion and contraction of the pipe to occur freely. To ensure good system stability, we recommend the use of at least 2 clips per pipe. Transair aluminium pipe should only be mounted using these clips. They should not be substituted by any other type of clip or fixing.
16,5 25 25 40 40 63 63
L (m)
3 3 6 3 6 3 6
Dmax (m)
2,5 2,5 3 2,5 4 2,5 4
> Properties
Transair fixing clips for 16,5 - 25 - 40: M6 nuts Transair fixing clips for 63 networks: M10 nuts
> Procedure
1 - Place the clip as required and open it using a screwdriver. 2 - Insert the pipe into the clip. 3 - Close the clip.
88 / 89
The Transair 6697 00 03 spacer is used for fitting a run of Transair pipe using different diameters.
> Spacer
Example :
76 76 100 100
L (m)
3 6 3 6
Dmax (m)
2,5 5 2,5 5
To ensure good network stability, we recommend the use of at least 2 fixing clips per length of pipe Transair fixing clips for 76 and 100 networks: M8/M10 thread
1 - Remove the nut at the base of the pipe clip using a screwdriver. Insert the screw by passing it through the clip. 2 - Tighten the screw.
U-channel assemblies are used to offset networks and to bypass obstacles. They comprise sectional rail ref. 6699 01 01 and a series of attachment accessories 66 99 01 02. For offsetting a 63 / 76 and 100 air system, we recommend the use of the rail clip attachment assembly ref. 6699 01 03.
63
76 - 100
90 / 91
Use the under-cabletray attachment ref. 6699 10 03 and suspend with threaded rod up to M10 diameter
16,5 - 25 - 40
63
76 - 100
C1 : M6 C2 : M8 ou M10
Handy! The Transair threaded rod adaptor allows 16,5 , 25 and 40 Transair pipe clips to be easily suspended under M8 or M10 threaded rod. C2: M8 or M10.
Position the clamps ref. 6699 02 onto the RSJ or beam in accordance with the minimum recommended number of attachments per length of pipe and the required distance between attachments, according to the diameter of the pipe
Push-on type beam clamps
> Using beam clamps Position the clamps ref. 6699 03 onto the RSJ or beam in accordance with the minimum recommended number of attachments per length of pipe and the required distance between attachments, according to the diameter of the pipe
Position the RSJ brackets ref. 6999 03 02 on either side of the girder profile, then slide through the U-channel sectional rail.
92 / 93
1 - Mount the Transair pipe clip onto the KN attachment. 2 - Suspend the attachment from the Canalis network and clip into place 3 - The support is ready.
1 - Mount the Transair pipe clip onto the KS attachment. 2 - Suspend the attachment from the Canalis network and secure with a screw. 3 - The support is ready.
> Z dimensions
Transair
4002 40 00 4002 63 00 4012 63 00 4089 17 00 4089 25 00 4099 17 00 4099 25 00 4230 00 40 6612 25 00 6612 40 00 6602 17 00 6602 25 00 6602 40 00 6602 63 00 6604 17 00 6604 25 00 6604 40 00 6604 63 00 6604 63 40 6606 17 00 6606 25 00 6606 40 00 6606 63 00 6651 25 12 04 6651 40 12 04 6662 25 00 6662 25 17 6662 40 17 6662 40 25 6662 63 25 6666 17 25 6666 25 40 6676 17 00 6676 25 00 6676 40 00 6676 63 00 RA69 25 17 RA69 40 25 RX02 L1 00 RX02 L3 00 RX04 L1 00 RX04 L3 00 RX04 L3 L1 RX23 L1 04 RX23 L3 04 RX24 L1 40 RX24 L1 63 RX24 L3 40 RX24 L3 63 RX64 L1 63 RX64 L3 63 VR02 L1 00 VR02 L3 00
Z (mm)
85 29 45 31 40 62 61 33 48 57 25 107 150 52 59 75 68 75 50 71 33 48 57 25 47,5 61 189 221 145 155 352 372 116 123
Z1 (mm)
57 84 84 29 40 29 40 34 48 57 61 61 145 155 155 145 145 155 155 -
Z2 (mm)
57 98 98 42 55 42 55 31 40 57 61 116 145 135 135 228 285 241 298
94 / 95
L : length of Transair straight line to be installed (in m) T : difference between temperature when installing and maximum operating temperature (in C) L: line length variation (in mm) For Transair 16.5 - 25 - 40 - 63 - 76 - 100 aluminium pipe networks : L = (a x L) + (0.024 x L x T)
1 2
1 - Expansion related to pipe retraction in the connector 2 - Expansion related to temperature variations
16,5 25 40 63 76 100
3 m pipe 6 m pipe
a=0,06 -
a=0,20 a=0,10
a=0,40 a=0,20
a=0,73 a=0,38
a=1,0 a=0,50
a=1,0 a=0,50
The following tables give the length variations in mm according to network length, diameter and temperature variation, for Transair aluminium pipe
3 m pipe
L (m) 16,5
13 17 21 25 29 34
6 m pipe
76
37 50 62 74 87 99
25
17 22 28 34 36 45
40
23 30 38 46 53 61
63
34 45 56 67 78 90
100
37 50 62 74 87 99
L (m)
30 40 50 60 70 80
25
14 18 23 28 29 37
40
17 22 28 34 39 45
63
22 30 37 44 52 59
76
22 30 37 44 52 59
100
22 30 37 44 52 59
T = 15C
30 40 50 60 70 80
3 m pipe
L (m) 16,5
16 22 27 32 38 43
6 m pipe
76
40 53 66 79 92 106
25
20 27 34 41 43 54
40
26 35 44 53 62 70
63
37 50 62 74 87 99
100
40 53 66 79 92 106
L (m)
30 40 50 60 70 80
25
17 23 29 35 36 46
40
20 27 34 41 48 54
63
26 34 43 52 60 69
76
25 33 41 49 57 66
100
25 33 41 49 57 66
T = 20C
30 40 50 60 70 80
3 m pipe
L (m)
30
6 m pipe
76
42 56 70 84 98 112
16,5
20 26 33 40 46 53
25
24 32 40 48 50 64
40
30 40 50 60 70 80
63
41 54 68 82 95 109
100
42 56 70 84 98 112
L (m)
30 40 50 60 70 80
25
21 28 35 42 43 56
40
24 32 40 48 56 64
63
29 39 49 59 69 78
76
27 36 45 54 63 72
100
27 36 45 54 63 72
T = 25C
40 50 60 70 80
3 m pipe
L (m)
30 40 50 60 70 80
6 m pipe
76
44 59 74 89 104 118
16,5
23 31 39 47 55 62
25
28 37 46 55 57 74
40
34 45 56 67 78 90
63
44 59 74 89 104 118
100
44 59 74 89 104 118
L (m)
30 40 50 60 70 80
25
25 33 41 49 50 66
40
28 37 46 55 64 74
63
33 44 55 66 77 88
76
29 39 49 59 69 78
100
29 39 49 59 69 78
T = 30C
96 / 97
3 m pipe
L (m) 16,5
27 36 45 54 63 72
6 m pipe
76
47 62 78 94 109 125
25
31 42 52 62 64 83
40
37 50 62 74 87 99
63
48 64 80 96 112 128
100
47 62 78 94 109 125
L (m)
30 40 50 60 70 80
25
28 38 47 56 57 75
40
31 42 52 62 73 83
63
37 49 61 73 85 98
76
32 42 53 64 74 85
100
32 42 53 64 74 85
>
T = 35C
30 40 50 60 70 80
Dmax (m)
Case no. 1: Maximum distance, without expansion loop, from a fixed point dependant on Transair diameter (2 elbows)
Transair Dmax. (m) 16,5 50 25 40 40 30 63 24 76 15 100 15
Case no. 2: Maximum distance, without expansion loop, dependant on Transair diameter (2 elbows - 1 fixed point)
Transair Dmax. (m) 16,5 50 25 40 40 30 63 25 76 15 100 15
Dmax (m)
Dmax (m)
> Example
H Pipe: 3 m length TC = 20C - H = 1,5m H Pipe: 3 m length TC = 20C - H = 1,5m
Case no. 3: Maximum distance for fitting a bracket, without expansion loop, dependant on Transair diameter (1 elbow - 1 bracket)
Transair Dmax. (m) 16,5 48 25 38 40 30 63 25 76 100 7,5 7,5
Case no. 4: Maximum distance for fitting a bracket, without expansion loop, dependant on Transair diameter (2 brackets)
Transair Dmax. (m) 16,5 80 25 70 40 55 63 40 76 15 100 15
> For Transair 16.5 - 25 - 40 - 63 aluminium pipe networks H= 0,75 m H= 1,50 m L1= 15 mm L1= 30 mm
> Using an elbow > For Transair 76 - 100 aluminium pipe networks H= 0,75 m H= 1,50 m L1= 10 mm L1= 20 mm
1
25 25 40 40 63
2
16,5 25 16,5 25 25
H (m)
1,5 1,5 1,5 1,5 1,5
L2 (mm)
13 13 13 13 13
L3 (mm)
26 26 26 26 26
The length variation L, calculated for the Transair line, must always be equal to or less than L2 and If this is not the case, then an expansion loop, using Transair flexible hose, must be added.
L3.
98 / 99
76 100
H (m)
0,75 0,75
L2 maxi (mm)
10 10
L3 maxi (mm)
10 10
millimetre (mm)
10 20 30 40 50 60 70 80 90 100
metre (m)
0,01 0,02 0,03 0,04 0,05 0,06 0,07 0,08 0,09 0,10 0,15 0,20 0,25 0,30 0,35 0,40 0,45 0,50 0,55 0,60 0,70 0,80 0,90 1,00
inch (in)
0,39 0,79 1,18 1,57 1,97 2,36 2,76 3,15 3,54 3,94 5,91 7,87 9,84 11,81 13,78 15,75 17,72 19,69 21,65 23,62 27,56 31,50 35,43 39,37
foot (ft)
0,03 0,07 0,10 0,13 0,16 0,20 0,23 0,26 0,30 0,33 0,49 0,66 0,82 0,98 1,15 1,31 1,48 1,64 1,80 1,97 2,30 2,62 2,95 3,28
yard (yd)
0,01 0,02 0,03 0,04 0,05 0,07 0,08 0,09 0,10 0,11 0,16 0,22 0,27 0,33 0,38 0,44 0,49 0,55 0,60 0,65 0,76 0,87 0,98 1,09
> Length
150 200 250 300 350 400 450 500 550 600 700 800 900 1 000
Bar
1 2 3 4 5 6 7
Atmosphere (atm)
0,99 1,97 2,96 3,95 4,93 5,92 6,91 7,90 8,88 9,87 10,86 11,84 12,83 13,82 14,80 15,79 19,74
PSI
14,50 29,00 43,50 58,00 72,50 87,00 101,50 116,00 130,50 145,00 159,50 174,00 188,50 203,00 217,50 232,00 290,00
> Pressure
8 9 10 11 12 13 14 15 16 20
100 / 101
Paint spray gun, small impact wrench, light/medium drill, blowgun Polisher, screwdriver Sheet metal cutter, large impact wrench, automatic plane Small automatic machines, miscellaneous tooling Large tools, power machines and associated equipment Air hoist, grinder
102 / 103
Laboratory (Chemistry)
Transair 40 Instant connection
104 / 105
Laboratory (Packaging)
Transair 63 and 25 Offset drops from a quick assembly bracket
Machinery (Watchmaking)
Transair 25
Transair
6605 6605 6605 6605 6606 6606 6606 6606 6612 6612 6621 6621 6621 6621 6621 6621 6625 6625 6625 6625 6651 6651 6660 6660 6660 6660 6660 6660 6660 6660 6660 6660 6660 6660 6661 6661 6661 6661 6661 6662 6662 6662 6662 6662 6666 6666 6666 6670 6670 6670 6670 6670 6670 6670 6670 6671 6671 6671 6671 6671 6671 6671 6671 6676 6676 6676 6680 6680 6681 6681 6685 6686 6697 6697 6697 6697 6697 6697 6697 6698 40 40 63 63 17 25 40 63 25 40 17 25 25 25 40 40 17 25 40 63 25 40 25 25 25 25 40 40 40 40 63 63 63 63 25 40 40 63 63 25 25 40 40 63 17 25 40 17 17 17 17 25 25 25 25 17 17 17 17 25 25 25 25 25 40 63 17 25 17 25 21 21 00 00 00 17 25 40 63 00 42 49 47 48 00 00 00 00 00 00 21 21 27 34 42 49 00 00 00 00 12 04 12 04 A1 E4 U1 U2 A1 E4 U1 U2 A1 E4 U1 U2 21 21 27 21 27 00 17 17 25 25 25 40 63 A1 E4 U1 U2 A1 E4 U1 U2 A1 E4 U1 U2 A1 E4 U1 U2 00 00 00 21 21 21 21 21 21 01 02 03 00 00 00 00 03 20 20 20 20 16 16 16 16 17 17 21 21 21 21 21 21 20 20 20 20 21 21 24 24 24 24 24 24 24 24 24 24 24 24 23 23 23 23 23 23 23 23 23 23 19 19 19 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 27 16 16 16 26 26 26 26 26 26 34 34 34 34 34 34 34 30
Transair
6698 00 04 6698 01 01 6698 01 02 6698 02 01 6698 02 02 6698 03 01 6698 04 01 6698 04 02 6698 04 03 6698 05 03 6698 10 01 6698 10 02 6698 11 01 6698 11 98 6698 99 03 6699 01 01 6699 01 02 6699 01 03 6699 02 01 6699 02 02 6699 02 03 6699 02 04 6699 02 05 6699 02 06 6699 03 01 6699 03 02 6699 04 01 6699 04 02 6699 04 60 6699 04 60 01 6699 04 63 6699 04 64 6699 04 65 6699 10 01 6699 10 02 6699 10 03 6700 00 13 6700 00 21 6701 00 13 6701 00 21 6702 00 13 6702 00 21 6703 00 13 6703 00 21 6704 00 13 6704 00 21 6705 00 13 6705 00 21 6706 00 21 6707 00 13 6707 00 21 6708 00 13 6708 00 21 6798 00 01 6798 00 02 6798 00 03 6798 00 04 6798 00 05 6798 00 06 6798 00 07 6798 00 08 9084 23 13TR 9084 23 17TR 9084 30 13TR 9084 30 17TR 9084 30 21TR 9085 23 06TR 9085 23 08TR 9085 23 10TR 9085 30 08TR 9085 30 10TR 9085 30 13TR 9086 23 13TR 9086 23 17TR 9086 30 13TR 9086 30 17TR 9086 30 21TR 9A86 01 10X099 9A86 01 13X099 9A86 01 70X099 30 30 30 31 31 30 31 31 32 32 38 38 38 38 15 35 35 35 36 36 36 36 36 36 36 35 52 52 52 52 52 53 53 37 37 37 48 48 48 48 49 49 49 49 50 50 50 50 50 48 48 49 49 51 51 51 51 51 51 51 51 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43
Transair
9A86 02 13X099 9A86 02 17X099 9A86 02 21X099 9A86 03 17X099 9A86 03 21X099 9A87 01 10X099 9A87 01 13X099 9A87 01 17X099 9A87 02 13X099 9A87 02 17X099 9A87 02 21X099 9A87 03 17X099 9A87 03 21X099 9A94 01 06X099 9A94 01 08X099 9A94 01 10X099 9A94 01 13X099 9A94 02 06X099 9A94 02 08X099 9A94 02 10X099 9A94 02 13X099 9A94 03 08X099 9A94 03 13X099 9A94 03 16X099 9D01 01 13P183 9D01 01 13P483 9D01 01 17P183 9D01 01 17P483 9D01 01 21P183 9D01 01 21P483 9D01 02 13P483 9D01 02 17P483 9D01 02 21P483 9D05 09 13P4 9D05 09 17P4 9D05 09 21P4 9D05 10 13P4 9D05 10 17P4 9D05 10 21P4 9D14 01 10P183 9D14 01 13P183 9D14 01 13P483 9D14 01 17P183 9D14 01 17P483 9D14 01 21P483 9D14 02 13P483 9D14 02 17P483 9D14 02 21P483 9D14 03 17P483 9D14 03 21P483 9D14 09 13P4 9D14 09 17P4 9D14 09 21P4 9D14 10 13P4 9D14 10 17P4 9D14 10 21P4 9D21 01 06P483 9D21 01 08P483 9D21 01 09P483 9D21 01 10P183 9D21 01 13P483 9D21 02 10P483 9D21 02 13P483 9D21 03 13P483 9D21 03 16P483 9D21 09 06P4 9D21 09 08P4 9D21 09 10P4 9D21 10 08P4 9D21 10 10P4 CA86 A1 02 CA86 A1 03 CA86 A1 04 CA86 E4 02 CA86 E4 03 CA86 E4 04 CA86 U1 02 CA86 U1 03 CA86 U1 04 CA86 U2 02 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 41 41 41 41 41 41 41 41 41 41
Transair
CA86 U2 03 CA86 U2 04 CA87 A1 02 CA87 A1 03 CA87 A1 04 CA87 E4 02 CA87 E4 03 CA87 E4 04 CA87 U1 02 CA87 U1 03 CA87 U1 04 CA87 U2 02 CA87 U2 03 CA87 U2 04 CA90 U1 01 CA90 U1 03 CA94 A1 06 CA94 A1 08 CA94 A1 10 CA94 E4 08 CA94 E4 10 CA94 E4 13 CA94 U1 06 CA94 U1 08 CA94 U1 10 CA94 U2 08 CA94 U2 10 CA94 U2 13 CP01 A1 02 CP01 A1 03 CP01 A1 04 CP01 E4 02 CP01 E4 03 CP01 E4 04 CP01 U1 02 CP01 U1 03 CP01 U1 04 CP01 U2 02 CP01 U2 03 CP01 U2 04 CP14 A1 02 CP14 A1 03 CP14 A1 04 CP14 E4 02 CP14 E4 03 CP14 E4 04 CP14 U1 02 CP14 U1 03 CP14 U1 04 CP14 U2 02 CP14 U2 03 CP14 U2 04 CP21 A1 06 CP21 A1 08 CP21 A1 10 CP21 E4 08 CP21 E4 10 CP21 E4 13 CP21 U1 06 CP21 U1 08 CP21 U1 10 CP21 U2 08 CP21 U2 10 CP21 U2 13 EA59 00 13 EA98 06 00 EA98 06 00 EA98 06 01 EA98 06 02 EA98 06 03 EF00 00 02 EF00 00 03 EF00 00 04 EF00 00 06 EF00 00 08 EF00 00 10 EF00 00 12 EF00 00 16 EF00 00 20 EF00 02 03 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 38 25 32 25 25 25 44 44 44 44 44 44 44 44 44 44
Transair
EF00 EF00 EF00 EF00 EF00 EF00 EF00 EF00 EF00 EF00 EF02 EF02 EF02 EF02 EF02 EF02 EF02 EF02 EF02 EF02 EF04 EF04 EF04 EF04 EF04 EF04 EF04 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF06 EF10 EF10 EF10 EF11 EF12 EF12 EF12 EF12 EF13 EF13 EF13 EF13 EF14 EF14 EF14 EF14 EF15 EF15 EF15 EF15 EF16 EF16 EF16 EF16 EF17 EF17 EF17 EF17 EF26 EF26 02 03 04 06 08 10 10 12 12 16 00 00 00 00 01 01 02 02 03 04 01 01 02 02 03 03 04 00 00 00 00 00 00 00 00 00 01 01 02 02 03 04 04 06 08 10 10 12 12 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 06 06 04 04 06 08 10 12 16 16 20 20 02 03 04 06 02 03 03 04 04 06 02 03 03 04 04 06 06 02 03 04 06 08 10 12 16 20 02 03 03 04 04 06 08 08 10 12 16 16 20 20 02 03 04 04 02 03 04 06 02 03 04 06 02 03 04 06 02 03 04 06 02 03 04 06 02 03 04 06 01 02 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 44 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 47 47 47 47 47 47 47 47 47 47 47 47 47 47
Transair
EF26 08 02 EF26 08 03 EF26 10 02 EF26 10 03 EF26 10 04 EF26 13 02 EF26 13 03 EF26 13 04 EF26 16 03 EF26 16 04 ER01 L1 00 ER01 L3 00 EW01 00 01 EW01 00 03 EW02 L1 00 EW02 L3 00 EW03 00 01 EW05 L1 00 01 EW05 L1 00 EW05 L3 00 EW06 00 01 EW07 00 01 EW08 00 01 EW09 00 30 FP01 L1 01 FP01 L1 02 FP01 L3 02 FP01 L3 03 RA65 25 04 RA65 40 04 RA69 25 17 RA69 40 25 RP01 L1 00 RP01 L3 00 RR01 L1 00 RR01 L3 00 RR05 L1 20 RR61 L1 08 RR61 L3 08 RX02 L1 00 RX02 L3 00 RX04 L1 00 RX04 L3 00 RX12 L1 00 RX12 L3 00 RX23 L1 04 RX23 L3 04 RX24 L1 40 RX24 L1 63 RX24 L3 40 RX24 L3 63 RX25 L1 00 RX25 L3 00 RX30 L1 00 01 RX30 L1 00 RX30 L3 00 RX64 L1 63 RX64 L3 63 RX66 L3 L1 TA03 L1 04 TA03 L3 04 TA06 L1 04 TA06 L1 06 TA06 L3 04 TA06 L3 06 VR02 L1 00 VR02 L3 00 VR03 00 02 VR03 00 03 VR03 00 04 VR03 00 06 VR03 00 08 VR03 00 10 VR03 00 12 VR03 00 16 VR03 00 20 47 47 47 47 47 47 47 47 47 47 34 34 33 33 33 33 33 21 21 21 21 14 30 31 15 15 15 15 22 22 22 22 16 16 16 16 21 22 22 17 17 18 18 17 17 19 19 18 18 18 18 20 20 21 21 21 19 19 19 14 14 14 14 14 14 28 28 29 29 29 29 29 29 29 29 29