Sunteți pe pagina 1din 2

Thomsit

DX

Product Information 3.Aug.2010(HK)
GEV = Association for the Control of Emissions in Products for Flooring Installation. EMICODE = Emission Code EC1 = Very Low Emission EC2 = Low Emission EC3 = Not Low Emission

FLOOR LEVELLING COMPOUND CSLM S C35 F7


For smoothing and levelling 0.5 - 10 mm in one application
especially for smoothing and levelling concrete and cement/sand screeds low dust generation during mixing low in tension Extra high strength and wear-resistant pumpable and suitable for heating subfloor quick drying in any thickness

Description
Thomsit DX is a universal and high strength smoothing and levelling compound for mineral based subfloors, especially cement/sand screed and concrete. Can be applied 0.5 - 10 mm in one application. Especially suitable for pump application. Roller castor resistant >1mm. Suitable for use over underfloor heating. Thomsit DX is suitable for levelling the subfloor before the application of the other flooring materials, e.g. PVC/Vinyl floorings, wooden flooring, carpet, etc. Thomsit DX is not recommended as a wearing surface for outdoor. For interior use only.

Properties
Special cement with selected additives. Very low emission GEV EMICODE EC1 certified product. Self-levelling, fast setting and fast drying. Set to foot traffic in approximately 2 hours. High final strength.

Substrates
The substrate must be free from structural defects, sound i.e. of adequate compressive and tensile strength, permanently dry and free from laitance, dust, surface treatments or contamination, which would impair the bond of the Thomsit product(s). It may be necessary to mechanically prepare the surface of the substrate. Prime absorbent, porous subfloors with Thomsit R777 multi-purpose primer, diluted 1:1 with water. Nonabsorbent, smooth subfloors should be primed with Thomsit R760 tunoprene primer. Substrate requirements: Strength C15; surface hardness > 1.2MPa; humidity of subfloor 4% Ensure the correct Thomsit primer is selected prior to the application of this product if in doubt please contact Thomsit Technical Services.

Application
Thomsit DX must be mixed in a clean container with clean water (6.5 ltrs to 25 kg bag of powder). Mix with an electric mixer (>750W and <600rpm) and suitable attachment. Mix to a lump-free consistency. Let it mature for approx. 2-3 minutes and mix again for 1 minute. Apply the product to the required thickness (<4mm) using a

THOMSIT DX

suitable finishing trowel. Alternatively, Thomsit DX can be applied with a proprietary continuous feed mixer pump. . Avoid drafts and direct sunlight. Warm ambient conditions, warm powder and/or mixing water will reduce the working and setting times; conversely, in cold conditions working and setting times will be extended. When applying above 10 mm (in one application), substitute with Thomsit DE 95 (3 40 mm).

Technical Information
Colour Supplied as Powder density Mixing ratio Consumption PH Initial setting to DIN 1164 Final setting to DIN 1164 Set to foot traffic Set to covering Application Time Compressive Strength Flexural/ Bending Strength Tensile Bonding Strength Storage Packaging Standard Grey powder 1.3 kg/ltr. 6.5 ltrs. clean water for 25 kg of DX approx. 1.5 kg/m2 per 1 mm thickness approx. 12 * 30 - 60 minutes * 60 - 120 minutes * approx. 5 8 hours * approx. 1 2 days approx. 30 minutes 1 day = 20.9 MPa; 28 days = 41 MPa 1 day = 7.1 MPa; 28 days = 10.3 MPa 1.81 MPa 6 months under normal conditions paper bag: 25kg pallet quantity: 48

Comply with JC/T 985-2005, DIN 19354

* The above information applies at normal ambient conditions, e.g. 23 C and 50-55% Relative Humidity.

Health & Safety


Contains cement. Strong alkali when mixed with water, protect eyes and skin. If the product comes into contact with skin rinse off with clean water. If the product comes into contact with eyes, rinse with clean water immediately and seek medical advice. Avoid inhalation of dry powder. Where appropriate, wear suitable Personal Protective Equipment (PPE) e.g. gloves, eye protection. For further advice, please read the relevant Thomsit Safety Data Sheets, available upon request.
Apply with a suitable finishing trowel Suitable for pump application Care should be taken to inform & protect others during use VOC emission below 200 g/m3 For improved Indoor & Environmental Air Quality

Disposal
Do not pour directly into drains. Retain the product for later use, or if beyond shelf life, mixes with water allow to cure and then dispose have in accordance with local regulations. Dispose of empty packaging in accordance with local regulations, or where appropriate recycle.
The information contained herein is general and not intended to be specific to any substrate, project or product system. The information is based on our experience to-date and the results of continuous and careful testing. Varying conditions and methods of use will influence the practical application of this product. The products optimum performance is also dependent upon the professional judgement of the user and their conformity to proper trade practice, relevant standards and codes of practice for installation, which are factors outside of our control. The issue of this Thomsit Product Information Sheet supersedes all previous information relevant to this product.