Hi all, API 2000 gives the relieving rate required in terms of Nm3/hr of air.

I am a bit confused over the equations to be used for converting this Nm3/hr of air to the actual vapour flow rate. The options given are: 1. Gas Law equation PV = ZnRT. Equating the terms for Air & gas at required temp & pressure & solving for the flow rate 2. W2 = W1 x SQRT ((Z1 x T1 x M2) / (M1 x Z2 x T2)) W2, Mass Flow rate of Air (Kg / hr) W1, Mass Flow rate of Gas (Kg / hr) Z1, Compressibility factor for Gas T1, Temperature of Gas in K M1, Molecular Weight of Gas (Kg / Kmole) M2, Molecular Weight of Air (Kg / Kmole) Z2, Compressibility Factor for air T2, Temperature of air in K 3. As mentioned in the link below http://www.enardo.com/solutions/solutions_equations.htm Of course all three gives different results. It would be quite helpful if anybody can explain me which equation to be used & more importantly WHY. Thanks in advance Kirangparihar, I'm not quite sure what you're asking. Please try to better explain what your problem is, as I don't think that I can address it properly without more help from you. I believe you're asking how to convert back and forth between Nm3/hr of air and Nm3/hr of a vapor stream that could be vented from a tank. Equations 1 & 2 are essentially the same, and are probably not enough to get you where you want to go. The Enardo equations are also very basic, but aren't going to get you any closer to what you need to know. I suggest that you start with understanding the characteristics of the device you are dealing with. Let's say you're interested in a relieving scenario where you want to vent process vapors from an atmospheric tank. (This is what I think you're interested in.) So you have somehow determined the flow rate of your vapor stream that will pass through a PSV to atmosphere. Now you look at the vendor's literature and discover that their devices are rated in Nm3/hr of air. Is this the situation you are facing? To delve into this further, I need your confirmation that I'm moving in the correct direction. Is this what you seek? If not, please correct my misunderstanding of your problem.

Thanks, Doug

Hi Doug First of all, thanks for your reply. The problem that I am facing is simple and will I try to explain although it may seem that I should have started the topic in Students Forum indeed!!! I have to size a Vapour Recovery Unit for the tank farm area. I have calculated the vapour loading for the VRU from API 2000 & essentially it gives the results in Nm3/hr of air (or SCFH of air). When I started converting back this flow rate to Kg/hr (mass flow rate), I used the Enardo equations for the same wherein the term "Volumetric Flow is inversely proportional to the square root of the Molecular Weight (MW) of the vapor". This thing raised the eyebrow of the Engineers here and asked me why can't we use simple PV = nRT wherein no square root term comes into picture! I had a vague answer for that.

I tried to derive the term sqrt (M2/M1) by using the continuity equation Q = A x v wherein v (velocity) is replaced using the equation Del. P = v^2 / 2g. From here I got the term "under root of Del.P" which again can be replaced by P = nRT/V. Somewhere I got close to term sqrt (M2/M1).

Hence Proved!!!. But I got no takers for my derivation since it contains other terms too & also I am not too confident. Also if we simply look API 520 equations we have flow rate proportional Sqrt (Temp, & 1/M.W). Now here the problem is that the along with Molecular weight, temperature is also a term in Sqrt. I got a lot of confusion! In simple words, for converting Nm3/hr of Air to Actual m3/hr (or Kg/hr), which of the 3 equations should I use

Thanks in advance

Kiran Parihar Kiran Parihar:

You are making some simple conversions much harder than they are by looking at too many confusing references. So let's forget all the equations you've looked at and start from fundamentals!!

Converting Nm3/h to actual m3/hr:

First of all, you must find out what reference temperature (Tr) and reference pressure (Pr) were used for defining the Nm3/h that you obtained. A Nm3 is usually (but not always) defined as being at 273.15 K and 101.325 kPa (kilopascals). Since other reference conditions may have been used, you should find out exactly what reference temperature and pressure was used to define your Nm3/h ... I want to stress that most strongly.

Now, using the universal gas law twice:

(1) ... (Pa)(Va) = (Za)(n)(R')(Ta) (2) ... (Pr)(Vr) = (Zr)(n)(R')(Tr)

Dividing equation (1) by equation (2), we get:

Va = (Vr)(Za/Zr)(Ta/Tr)(Pr/Pa)

where: Va = actual m3/hr Vr = Nm3/h Za = compressibility factor at Ta and Pa, dimensionless Zr = compressibility factor at Tr and Pr, dimensionless Ta = the absolute temperature at which you want the actual m3/h, in K Pa = the absolute pressure at which you want the actual m3/h, in kPa (i.e., kiloPascals) Tr = the absolute reference temperature that applies to your Nm3/h, in K Pr = the absolute reference pressure that applies to your Nm3/h, in kPa (i.e., kiloPascals)

Unless your actual condition pressure (Pa) is quite high or you need some very high accuracy, in most cases you can ignore using the compressibility factors.

Converting either Nm3/h or actual m3/h to kg/h:

Again, start with the universal gas law:

(3) ... (P)(V) = (Z)(n)(R')(T) ..... and since n = w/M, we get: (4) ... w = (M)(P)(V) / [(Z)(R')(T)]

where: w = kg/h M = molecular weight of the gas T = absolute temperature, in K P = absolute pressure, in kPa (i.e., kiloPascals) R' = the universal gas law constant of 8.3145 Z = the compressibility, dimensionless

Equation (4) could be used to get kg/h based on using either the Z, P and T of your actual m3/h or the reference Z, P and T of your Nm3/h. Either way should give the same answer.

I am assuming that up to this point, everything is based on air (M = 28.96). So finally, to convert to your actual gas: kg/h of gas = (kg/h of air)(M of gas) / (M of air) To clear up confusion about square root term:

If your Nm3/h of air was obtained from a flow meter of some type that works by measuring a P across an orifice or some other device and you want to re-calibrate the meter to use a different set of reference temperature and pressure, then the square root term comes into play. But, in this case, it seems to me that you are not trying to re-calibrate a meter. You are simply tring to convert the Nm3/h of air (that you got from a meter or some other way) to kg/h of your actual gas. In that case, the above equations are all you need! -------------------Milton Beychok Kiran:

There's not much I can add to Milton's excellent and comprehensive reply to your question. In fact, your question alerted me to my own ignorance of the principles involved in venting devices. Though I'm finding this question a bit difficult to express, I am curious if a conservation vent, PSV, etc. would be considered to be mass or a volumetric devices. I know that for gases conservation vent and PSV's and rupture disks, etc. tend to be rated in Nm3 or SCF per unit of time. If they were volumetric devices, then if the molecular weight changed, they would still be capable of passing the same Nm3 or SCF as before (constant volume = constant moles). If they are mass flow devices, then if the molecular weight were to increase, then the Nm3 or SCF rating would have to decrease to keep the kg/hr or lb/hr constant (but moles vary). Could anyone explain how these devices operate? Thanks, Doug