Product data
Introduction Performance range of CR, CRI, CRN Performance range of CRE, CRIE, CRNE Applications Product range Pump Motor Terminal box positions Ambient temperature Viscosity 3 4 4 5 6 8 8 9 9 9
CR, CRE 90 CRN, CRNE 90 CR 120 CRN 120 CR 150 CRN 150
50 52 54 56 58 60
Control of E-pumps
Examples of E-pump applications Central management system Remote control Control panel Control modes for E-pumps CRE, CRIE, CRNE with integrated pressure sensor CRE, CRIE and CRNE without sensor 10 11 11 11 12 12 12
Motor data
Standard motors for CR, CRI, CRN, 50 Hz E-motors for CRE, CRIE, CRNE, 50 Hz 63 63
Motor starting
Motor starting 64
Accessories
Counter flanges for CRI(E) and CRN(E) PJE couplings for CRN(E) FlexiClamp base connections Pipework connection Counter flanges for CR(E) Potentiometer for CRE, CRIE, CRNE G10-LON interface for CRE, CRIE, CRNE LiqTec for CR(E), CRI(E) and CRN(E) Remote control, R100 EMC filter for CRE, CRIE, CRNE Sensors for CRE, CRIE, CRNE 67 69 69 71 71 72 72 72 72 72 73
Variants
Lists of variants - on request 74
Product data
Introduction
This data booklet deals with CR, CRI and CRN as well as CRE, CRIE and CRNE pumps. CRE, CRIE, CRNE
GR5381
CRE, CRIE and CRNE pumps are built on the basis of CR, CRI, CRN pumps. CRE, CRIE and CRNE pumps belong to the so-called E-pump family. CRE, CRIE and CRNE pumps are referred to as E-pumps. The difference between the CR and the CRE pump range is the motor. CRE, CRIE and CRNE pumps are fitted with an E-motor, i.e. a motor with built-in frequency control. The CRE pump motor is a Grundfos MGE or MMGE motor designed to EN standards. Frequency control enables continuously variable control of motor speed, which makes it possible to set the pump to operation at any duty point. The aim of continuously variable control of the motor speed is to adjust the performance to a given requirement. CRE, CRIE and CRNE pumps are available with an integrated pressure sensor connected to the frequency control. The pump materials are identical to those of the CR, CRI and CRN pump range. Selecting a CRE pump Select a CRE pump if the following features are required: Controlled operation, i.e. consumption fluctuates Constant pressure Communication with the pump. Adaptation of performance through frequency-controlled speed control offers obvious benefits such as: energy savings increased comfort control and monitoring of the pump performance.
CR, CRI, CRN CR, CRI and CRN pumps are vertical multistage centrifugal pumps. The in-line design enables the pump to be installed in a horizontal one-pipe system where the suction and discharge ports are in the same horizontal plane and have the same pipe dimensions. This design provides a more compact pump design and pipework. Grundfos CR pumps are available in various sizes and various numbers of stages to provide the flow and pressure required. CR pumps are designed for a variety of applications from the pumping of potable water to the pumping of chemicals. The pumps are therefore suitable for a wide diversity of pumping systems where the performance and material of the pump meet specific demands. The CR pumps consist of two main components: The motor and the pump unit. The CR pump motor is a Grundfos motor designed to EN standards. The pump unit consists of optimised hydraulics, various types of connections, an outer sleeve, a pump head and various other parts. CR pumps are available in various material versions according to the pumped liquid.
Product data
Performance range of CR, CRI, CRN
H [m]
400 300 200
CR 32 CRN 32
50 Hz
CR 64 CRN 64
CRI 1 CRN 1
CRI 5 CRN 5
CRI 15 CRN 15
CR 45 CRN 45
CR 90 CRN 90
Eta [%]
80 60 40 20 0 0.8 1 1 2 3 4 High pressure range 5 6 8 10 20 30 40 50 60 80 100
Q [m/h]
200
Q [m/h]
50 Hz
200
100 80
CRIE 1 CRIE 5 CREN 5 CRIE 15 CRNE 15 CRNE 1
CRE 32 CRNE 32
CRE 64 CRNE 64
60
CRE 45 CRIE 3 CRNE 3 CRIE 10 CRNE 10 CRIE 20 CRNE 20 CRNE 45 CRE 90 CRNE 90
40
30
TM03 1689 2705
20 0.8 1 1 2 3 4 5 6 8 10 20 30 40 50 60 80 100
Q [m/h]
Product data
Applications
Application Water supply Filtration and transfer at waterworks Distribution from waterworks Pressure boosting in mains Pressure boosting in high-rise buildings, hotels, etc. Pressure boosting for industrial water supply Industry Pressure boosting Process-water systems Washing and cleaning systems Vehicle-washing tunnels Fire-fighting systems Liquid transfer Cooling and air-conditioning systems (refrigerants) Boiler-feed and condensate systems Machine tools (cooling lubricants) Aquafarming Special transfer duties Oils and alcohols Acids and alkalis Glycol and coolants Water treatment Ultra-filtration systems Reverse-osmosis systems Softening, ionising, demineralising systems Distillation systems Separators Swimming baths Irrigation Field irrigation (flooding) Sprinkler irrigation Drip-feed irrigation z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z z CR, CRI CRN
CRE, CRNE z z z z z
z z z z z
Recommended version. Alternative version. CRT, CRTE version available. For further information about CRT, CRTE pumps, see "Pumped liquids", page 65, or related CRT, CRTE data booklet.
Product data
Product range
Range Nominal flow rate [m3/h] Temperature range [C] Temperature range [C] on request Max. pump efficiency [%] CRI pumps Flow range [m3/h] Max. pressure [bar] High pressure [bar] on request Motor power [kW] CRIE pumps Flow range [m3/h] Max. pressure [bar] Motor power [kW] Version CRI, CRIE: Stainless steel EN 1.4301/AISI 304 CRN, CRNE: Stainless steel EN 1.4401/AISI 316 CRT, CRTE: Titanium CRI, CRIE pipe connection Oval flange (BSP) Oval flange (BSP) on request Flange Flange on request PJE coupling (Victaulic) Clamp coupling (L-coupling) Union (+GF+) CRN(E) pipe connection Flange Flange on request PJE coupling (Victaulic) Clamp coupling (L-coupling) Union (+GF+) DN 25/ DN 32 R 1 DN 32 48.3 G2 DN 25/ DN 32 R 1 DN 32 48.3 G2 DN 25/ DN 32 R 1 DN 32 48.3 G2 DN 25/ DN 32 R 1 DN 32 48.3 G2 DN 40 DN 50 R2 DN 50 60.3 G 2 R 1 DN 32 48.3 G2 R 1 DN 32 48.3 G2 R 1 DN 32 48.3 G2 R 1 DN 32 48.3 G2 DN 50 R2 DN 50 60.3 G 2 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 1 Rp 2 z z z z z 0.7-2.4 22 0.37-2.2 1.2-4.5 24 0.37-3 2.5-8.5 24 0.37-5.5 5-13 22 0.37-7.5 0.3-1.1 21 0.37-1.1 0.7-2.4 22 47 0.37-2.2 1.2-4.5 24 41 0.37-3 2.5-8.5 24 47 0.37-5.5 5-13 22 44 0.37-7.5 35 48 58 CRI 1s 0.8 CRI, CRIE 1 1 CRI, CRIE 3 3 CRI, CRIE 5 5 20 to +120 40 to +180 66 70 CRI, CRIE 10 10
CRI, CRIE 15 15
CRI, CRIE 20 20
DN 50 R2 DN 50 60.3 G 2
DN 50 R2 DN 50 60.3 G 2
DN 50 R2 DN 50 60.3 G 2
DN 50 R2 DN 50 60.3 G 2
Product data
Range Nominal flow rate [m3/h] Temperature range [C] Temperature range [C] on request Max. pump efficiency [%] CR pumps Flow range [m3/h] Max. pressure [bar] High pressure [bar] on request Motor power [kW] CRIE pumps Flow range [m3/h] Max. pressure [bar] Motor power [kW] Version CR, CRE: Cast iron and stainless steel EN 1.4301/AISI 304 CRN, CRNE: Stainless steel EN 1.4401/AISI 316 CRT, CRTE: Titanium CR, CRE pipe connection Oval flange (BSP) Oval flange (BSP) on request Flange Flange on request CRI, CRIE pipe connection Oval flange (BSP) Oval flange (BSP) on request Flange Flange on request PJE coupling (Victaulic) Clamp coupling (L-coupling) Union (+GF+) CRN(E) pipe connection Oval flange (BSP) Oval flange (BSP) on request Flange Flange on request PJE coupling (Victaulic) Clamp coupling (L-coupling) Union (+GF+)
1) 2)
CR, CRE 32 32
CR, CRE 45 45
CR, CRE 64 64
CRI CRE 90
CR 120 120
CR 150 150
40 to +180 78 15-40 28 39 1.5-30 15-40 28 1.5-22 79 22-58 33 39 3-45 22-58 26 3-22 80 30-85 22 39 4-45 30-85 20 4-22
75 60-160 21 41 11-75 -
72 75-180 19 39 11-75 -
z -
z -
DN 65 DN 80 DN 65 DN 80 3" 2) -
CRN 32 to CRN 90 with HQQE shaft seal: 40 C to 120 C On request. See the CR "Custom-built pumps" catalogue.
Product data
Pump
The CR and CRE pumps are non-self-priming, vertical multistage centrifugal pumps. The pumps are available with a Grundfos standard motor (CR pumps) or a frequency-controlled motor (CRE pumps). The pump consists of a base and a pump head. The chamber stack and the outer sleeve are secured between the pump head and the base by means of staybolts. The base has suction and discharge ports on the same level (in-line). All pumps are equipped with a maintenance-free mechanical shaft seal of the cartridge type.
Frequency-controlled motors: MGE CRE, CRIE and CRNE pumps are fitted with a totally enclosed, fan-cooled, 2-pole frequency-controlled motor with principal dimensions to EN standards. Electrical tolerances comply with EN 60034. CRE, CRIE, CRNE pumps from 0.37 to 1.1 kW are fitted with single-phase MGE motors as standard. CRE, CRIE, CRNE pumps from 0.75 to 1.1 kW are also available with three-phase MGE motors. See Win-/ WebCAPS. Electrical data CR, CRI, CRN
MG motor Mounting designation Up to 4 kW: V 18 From 5.5 kW: V 1 F EFF 1 (0.37-0.75 kW pumps are EFF 2) IP 55 P2: 0.37-1.5 kW: 3 x 220-240/380-415 V
Motor
Coupling
Enclosure class
Pump head
50 Hz
Base plate
Fig. 3 CR pump
Motor
Grundfos standard motors: MG and Siemens motors CR, CRI and CRN pumps are fitted with a totally enclosed, fan-cooled, 2-pole Grundfos standard motor with principal dimensions to EN standards. Electrical tolerances according to EN 60034. CR, CRI, CRN pumps are fitted with three-phase MG motors as standard. CR, CRI, CRN pumps from 0.37 to 2.2 kW are also available with single-phase motors (1 x 220-230/ 240 V). See Win-/WebCAPS.
Optional motors The Grundfos standard range of motors covers a wide variety of application demands. However, for special applications or operating conditions, custom-built motor solutions can be provided. For special applications or operating conditions, Grundfos offers custom-built motors such as: ATEX-approved motors MG motors with anti-condensation heating unit motors with thermal protection.
Product data
Motor protection MG and Siemens motors Single-phase Grundfos motors have a built-in thermal overload switch (IEC 34-11: TP 211). Three-phase motors must be connected to a motor starter in accordance with local regulations. Three-phase Grundfos motors from 3 kW and upwards have a built-in thermistor (PTC) according to DIN 44 082 (IEC 34-11: TP 211). MGE motors CRE, CRIE, CRNE pumps require no external motor protection. The MGE motor incorporates thermal protection against slow overloading and blocking (IEC 34-11: TP 211).
Ambient temperature
Motor power [kW] 0.37-0.75 1.1-11 15-75 Motor make Grundfos MG Grundfos MG Siemens Motor efficiency class EFF 2 EFF 1 EFF 1 Maximum ambient temperature [C] +40 +60 +55 Maximum altitude above sea level [m] 1000 3500 2750
If the ambient temperature exceeds the above temperature values or the pump is installed at an altitude exceeding the above altitude values, the motor must not be fully loaded due to the risk of overheating. Overheating may result from excessive ambient temperatures or the low density and consequently low cooling effect of the air. In such cases, it may be necessary to use a motor with a higher rated output.
P2 [%] 100 90 80
EFF 2, MG
60
Position 6 Standard
Position 9
Position 12
Position 3
Viscosity
The pumping of liquids with densities or kinematic viscosities higher than those of water will cause a considerable pressure drop, a drop in the hydraulic performance and a rise in the power consumption. In such situations the pump should be equipped with a larger motor. If in doubt, contact Grundfos.
Control of E-pumps
Examples of E-pump applications
CRE, CRIE and CRNE pumps are the ideal choice for a number of applications characterised by a need for variable flow at constant pressure. The pumps are suited for water supply systems and pressure boosting as well as for industrial applications. Depending on the application, the pumps offer energysavings, increased comfort and improved processing. E-pumps in the service of industry Industry uses a large number of pumps in many different applications. Demands on pumps in terms of pump performance and mode of operation make speed control a must in many applications. Below is listed some of the applications in which Epumps are often used. Constant pressure water supply washing and cleaning systems distribution from waterworks humidifying systems water treatment systems process boosting systems, etc. Example: Within industrial water supply, E-pumps with integrated pressure sensor are used to ensure a constant pressure in the piping network. From the sensor, the E-pump receives inputs about changes of pressure as a result of changes in the consumption. The E-pump responds to the input by adjusting the speed until the pressure is equalized. The constant pressure is stabilized once more on the basis of a preset setpoint. Constant temperature air-conditioning systems at industrial plants industrial cooling systems industrial freezing systems casting and moulding tools, etc. Example: In industrial freezing systems, E-pumps with temperature sensor increase comfort and lower operating costs compared with pumps without a temperature sensor. An E-pump continuously adapts its performance to the changing demands reflected in the differences in temperature of the liquid circulating in the freezing system. Thus, the lower the demand for cooling, the smaller the quantity of liquid circulated in the system and vice versa. Constant flow steam boiler systems condensate systems sprinkler irrigation systems chemical industry, etc.
Example: In a steam boiler, it is important to be able to monitor and control pump operation to maintain a constant level of water in the boiler. By using an E-pump with level sensor in the boiler, it is possible to maintain a constant water level. A constant water level ensures optimum and cost-efficient operation as a result of a stable steam production. Dosing applications chemical industry (i.e. control of pH-values) petrochemical industry paint industry degreasing systems bleaching systems, etc. Example: In the petrochemical industry, E-pumps with pressure sensor are used as dosing pumps. The Epumps helps to ensure that the correct mixture ratio is achieved when more liquids are combined. E-pumps functioning as dosing pumps improves processing and offer energy-savings. E-pumps in commercial building services Commercial building services use E-pumps to maintain a constant pressure or a constant temperature based on a variable flow. Constant pressure Water supply in high-rise buildings such as office buildings and hotels. Example: E-pumps with pressure sensor are used for water supply in high-rise buildings to ensure a constant pressure even at the highest draw-off point. As the consumption pattern and thus the pressure changes during the day, the E-pump continuously adapts its performance until the pressure is equalized. Constant temperature air-conditioning systems in hotels, schools, etc. building cooling systems, etc. Example: E-pumps are an excellent choice for buildings where constant temperature is essential. E-pumps keep the temperature constant in air-conditioned highrise glass buildings, irrespective of the seasonal fluctuations of the outdoor temperature and various heat impacts inside the building.
10
Control of E-pumps
Control options of E-pumps Communication with CRE, CRIE, CRNE pumps is possible by means of either of the following: a central management system remote control (Grundfos R100) a control panel. The purpose of controlling an E-pump is to monitor and control the pressure, temperature, flow and liquid level of the system.
Remote control
The R100 remote control produced by Grundfos is available as an accessory. The operator communicates with the E-pump by pointing the IR-signal transmitter at the control panel of the E-pump terminal box.
Communication with the E-pump is possible even if the operator is not present near the E-pump. Communication is enabled by connecting the E-pump to a central management system. This allows the operator to monitor the pump and to change control modes and setpoint settings.
On the R100 display it is possible to monitor and change control modes and settings of the E-pump.
Control panel
Control management system
The control panel of the E-pump terminal box makes it possible to change the setpoint settings manually.
Light fields
LON connection
E-pump
11
Control of E-pumps
Control modes for E-pumps
Grundfos offers CRE, CRIE and CRNE pumps in two different variants: CRE, CRIE and CRNE with integrated pressure sensor CRE, CRIE and CRNE without sensor.
In constant-curve mode, the pump is not controlled. It can be set to pump according to a preset pump characteristic within the range from min. curve to max. curve, see figure below.
H
Max.
TM00 9323 1204
Min.
Max.
A CRE, CRIE or CRNE pump with integrated pressure sensor facilitates installation and commissioning. CRE, CRIE and CRNE pumps with integrated pressure sensor can be set to either of these modes: constant-pressure mode (factory setting) constant-curve mode. In constant-pressure mode, the pump maintains a preset pressure after the pump, irrespective of the flow, see figure below.
H
Q set
In uncontrolled-operation mode, the pump operates according to the constant curve set, see figure below.
H
Max. Min.
TM00 9323 1204
Hset
CRE, CRIE and CRNE pumps can be fitted with sensor types meeting the requirements mentioned in the data booklet titled "Grundfos E-pumps".
12
Min.
Construction
CRI(E), CRN(E) 1s, 1, 3, 5, 10, 15 and 20
Sectional drawing
Sectional drawing
1
3
3 2 4 5 9 6 7
TM02 1195 1403
10
10
4 6 11 7 8 1 5 9
TM01 1836 1403
12
11
Materials, CR(E)
EN/DIN EN-JL1030 1.4408 1.4401 1.4460 3) 1.4408
2)
Materials Cast iron EN-GJL-200 1) Stainless steel Stainless steel Stainless steel
AISI/ASTM ASTM 25B CF 8M equal to AISI 316 AISI 316 AISI 329 CF 8M equal to AISI 316
Pos. Designation 1 2 3 4 5 6 7 Pump head Motor stool Shaft Impeller Chamber Outer sleeve O-ring for outer sleeve Base Neck ring Shaft seal Bearing ring Bottom bearing ring Rubber parts
Materials Cast iron EN-GJS-500-7 Cast iron EN-GJL-200 Stainless steel Stainless steel Stainless steel Stainless steel EPDM or FKM Cast iron EN-GJS-500-7 Carbon-graphitefilled PTFE Bronze Tungsten carbide/ tungsten carbide EPDM or FKM
AISI/ASTM ASTM 80-55-06 ASTM 25B AISI 431 AISI 304 AISI 304 AISI 304
Impeller Chamber Outer sleeve O-ring for outer sleeve Impeller Chamber Outer sleeve O-ring for outer sleeve
PTFE Cartridge type Cast iron EN-JL1030 EN-GJL-200 1) EPDM or FKM CRI(E) Stainless steel 1.4301 Stainless steel 1.4301 Stainless steel 1.4401 EPDM or FKM CRN(E) Stainless steel Stainless steel Stainless steel EPDM or FKM 1.4401 1.4401 1.4401
EN-JS1050
ASTM 80-55-06
Stainless steel available on request. CRI(E), CRN(E) 1S, 1, 3, 5 3) CRI(E), CRN(E) 10, 15, 20
13
Construction
CRN(E) 32, 45, 64 and 90 CR 120 and 150
Sectional drawing
Sectional drawing
3 10
4 6 11 7 8
1 5 9
12
13
Materials, CRN(E)
Pos. Designation Materials 1 2 3 4 5 6 7 8 9 10 11 12 13 Pump head Motor stool Shaft Impeller Chamber Stainless steel Cast iron EN-GJL-200 1) Stainless steel Stainless steel Stainless steel EN/DIN 1.4408 EN-JL1030 1.4462 1.4401 1.4401 1.4401 AISI 316 AISI 316 AISI 316 AISI/ASTM CF 8M equal to AISI 316 ASTM 25B
Materials, CR
Pos. Designation 1 Pump head Motor stool (11-45 kW) Motor stool (55-75 kW) Shaft Impeller Chamber Outer sleeve Materials Cast iron EN-GJS-500-7 Cast iron EN-GJL-200 Cast iron EN-GJS-500-7 Stainless steel Stainless steel Stainless steel Stainless steel EN/DIN EN-JS1050 EN-JL1030 EN-JS1050 1.4057 1.4301 1.4301 1.4401 AISI/ASTM A 536 65-45-12 A48-30 B A 536 65-45-12 AISI 431 AISI 304 AISI 304 AISI 316
3 4 5 6
Outer sleeve Stainless steel O-ring for EPDM or FKM outer sleeve Base Neck ring Shaft seal Bearing ring Bottom bearing ring Base plate Carbon-graphite filled PTFE Tungsten carbide/tungsten carbide Stainless steel 2) Stainless steel Carbon-graphite filled PTFE
1.4408
7 8 9 10 11
O-ring for outer EPDM or FKM sleeve Base Base plate Neck ring Shaft seal1) Cast iron EN-GJS-500-7 Cast iron EN-GJS-500-7 PTFE SiC/SiC (22) Carbon/SiC (32) PTFE SiC/SiC EPDM or FKM EN-JS1050 EN-JS1050 A 536 65-45-12 A 536 65-45-12
1.4408
12 13
Stainless steel available on request. Stainless steel available on request for CRNE pumps, standard base plate for CRNE is cast iron.
1)
14
GrA3731
Construction
CRN 120 and 150
Sectional drawing
Materials, CRN
Pos. Designation 1 Pump head Motor stool (11-45 kW) Motor stool (55-75 kW) Shaft Impeller Chamber Outer sleeve O-ring for outer sleeve Base Base plate Neck ring Shaft seal2) Materials Stainless steel Cast iron EN-GJL-200 Cast iron EN-GJS-500-7 Stainless steel Stainless steel Stainless steel Stainless steel EPDM or FKM Stainless steel Stainless steel 1) PTFE SiC/SiC (22) Carbon/SiC (32) 1.4408 1.4408 A 351 CF 8M A 351 CF 8M EN/DIN 1.4408 EN-JL1030 EN-JS1050 1.4462 1.4401 1.4401 1.4401 AISI/ASTM A 351 CF 8M A48-30 B A 536 65-45-12 SAF 2205 AISI 316 AISI 316 AISI 316
3 4 5 6 7 8 9 10 11 12 13 14
Support bearPTFE ing Bearing ring Base plate Rubber parts SiC/SiC Stainless steel 1) EPDM or FKM 1.4408 A 351 CF 8M
1) 2)
Cast iron available on request. 22 mm shaft, 11-45 kW. 32 mm shaft, 55-75 kW.
GrA3732 - GrA3735
15
Construction
Type keys
CR(E), CRI(E), CRN(E)
Example Type range: CR, CRI, CRN Pump with integrated frequency control Flow rate [m3/h] All impellers with reduced diameter (applies only to CR, CRI, CRN 1s) Number of impellers Number of reduced-diameter impellers (CR(E), CRN(E) 32, 45, 64, 90, 120 and 150) Code for pump version Code for pipe connection Code for materials Code for rubber parts Code for shaft seal CR E 32 (s) -4 -2 -A -F -G -E -HQQE
Codes
Example Pump version A B E F H HS I J K M N P R Basic version Oversize motor Pump with certificate/approval CR pump for high temperatures (aircooled top assembly) Horizontal version High-pressure pump with high speed MGE motor Different pressure rating Pump w/different max. speed Pump with low NPSH Magnetic drive Fitted with sensor Undersize motor Horizontal version with bearing bracket A -F -A -E -H QQ E
Pipe connection A B CA F G J N P X Oval flange NPT thread FlexiClamp (CRI(E), CRN(E) 1, 3, 5, 10, 15, 20) DIN flange ANSI flange JIS flange Changed diameter of ports PJE coupling Special version
Materials A D G GI I II K S X Basic version Carbon-graphite-filled PTFE (bearings) Wetted parts 1.4401/AISI 316 All parts stainless steel, wetted parts 1.4401/AISI 316 Wetted parts 1.4301/AISI 304 All parts stainless steel, wetted parts 1.4301/AISI 304 Bronze (bearings) SiC bearings + PTFE neck rings Special version
Shaft seal H Q U B E F K V Balanced cartridge seal Silicon carbide Tungsten carbide Carbon EPDM FXM FFKM FKM
16
Max. permissible operating pressure CRI, CRN 1s CRI(E), CRN(E) 1 CRI(E), CRN(E) 3 CRI(E), CRN(E) 5 CRI(E) 10-1 CRI(E) 10-17 CRN(E) 10 CRI(E) 15-1 CRI(E) 15-1 CRI(E) 15-12 CRN(E) 15 CRI(E) 20-1 CRI(E) 20-1 CRI(E) 20-12 CRN(E) 20 CR(E), CRN(E) 32-1-1 CR(E), CRN(E) 32-8-2 CR(E), CRN(E) 45-1-1 CR(E), CRN(E) 45-6-2 CR, CRN 45-12-2 CR(E), CRN(E) 64-1-1 CR, CRN 64-6-2 CR(E), CRN(E) 90-1-1 CR, CRN 90-5-2 CR, CRN 120 CR, CRN 150 32-7 32-14 45-5 45-11 45-13-2 64-5 64-8-1 90-4 90-6 20-7 20-10 20-17 15-7 15-10 15-17 10-16 10-22 16 bar 16 bar 16 bar 16 bar 16 bar 10 bar 10 bar -
Liquid Max. permissible temperature range operating pressure 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 25 bar 25 bar 25 bar 25 bar 16 bar 25 bar 25 bar 16 bar 25 bar 25 bar 16 bar 25 bar 25 bar 16 bar 30 bar 16 bar 30 bar 33 bar 16 bar 30 bar 16 bar 30 bar 30 bar 30 bar
Liquid temperature range 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 20 C to +120 C 30 C to +120 C 30 C to +120 C 30 C to +120 C 30 C to +120 C 30 C to +120 C 30 C to +120 C 30 C to +120 C 30 C to +120 C 30 C to +120 C 30 C to +120 C 30 C to +120 C
Description O-ring (cartridge) (balanced seal), SiC/SiC, EPDM O-ring (cartridge) (balanced seal), Carbon/SiC, EPDM O-ring (cartridge) (balanced seal), SiC/SiC, FKM O-ring (cartridge) (balanced seal), Carbon/SiC, FKM
40 C to +120 C
20 C to +90 C
See "Variants on request", page 74, in case of extreme temperatures: low temperatures down to 40 C or
TM03 8853 2807
17
Examples of operating and inlet pressures The values for operating and inlet pressures shown in the table should not be considered individually but should always be compared, see the following examples: Example 1: The following pump type has been selected: CRI 5-16 A-CA-A Max. operating pressure: Max. inlet pressure: 16 bar 10 bar
Discharge pressure against a closed valve: 10.6 bar, see page 30. This pump is not allowed to start at an inlet pressure of 10 bar, but at an inlet pressure of 16.0 10.6 = 5.4 bar. Example 2: The following pump type has been selected: CRI 10-2 A-CA-A Max. operating pressure: Max. inlet pressure: 16 bar 8.0 bar
CRI(E), CRN(E) 5
CRI(E), CRN(E) 10
CRI(E), CRN(E) 15
CRI(E), CRN(E) 20
Discharge pressure against a closed valve: 2.0 bar, see page 32. This pump is allowed to start at an inlet pressure of 8.0 bar, as the discharge pressure against a closed valve is only 2.0 bar, which results in an operating pressure of 8.0 + 2.0 = 10.0 bar. On the contrary, the max. operating pressure of this pump is limited to 16.0 bar, as a higher operating pressure will require an inlet pressure of more than 8.0 bar. In case the inlet or operating pressure exceeds the pressure permitted, see "Variants on request", page 74.
CR(E), CRN(E) 32
CR(E), CRN(E) 45
CR(E), CRN(E) 64
CR(E), CRN(E) 90
CR, CRN 120 120-1 120-2-1 120-2 120-5-1 120-6-1 120-7 CR, CRN 150 150-1-1 150-1 150-2-1 150-4-2 150-5-2 150-6
18
Pump efficiency Before determining the best efficiency point, the operation pattern of the pump needs to be identified. Is the pump expected to operate at the same duty point, then select a CR pump which is operating at a duty point corresponding with the best efficiency of the pump.
p H [MPa] [m]
280 260 2.4 240 220 2.0 200 180 1.6 160 140 1.2 120 100 0.8 80 60 0.4 40 20 -14 -13 -12 (E) -11 -10 (E) -10-2 -9 -8 (E) -7 -7-2 -6 (E) -5 -5-2 -4 (E) -4-2 -3 (E) -3-2 -2 (E) -2-2 (E) -1 (E) -1-1 (E) -6-2 -9-2 -8-2 -14-2 -13-2 -12-2 -11-2
CR, CRE 32
50 Hz
ISO 9906 Annex A
Duty point
p H [MPa] [m]
280 260 2.4 240 220 2.0 200 180 1.6 160 140 1.2 120 100 0.8 80 60 0.4 40 20 0.0 0 0 4 8 12 16 20 24 28 32 -14 -13 -12 (E) -11 -10 (E) -10-2 -9 -8 (E) -7 -7-2 -6 (E) -5 -5-2 -4 (E) -4-2 -3 (E) -3-2 -2 (E) -2-2 (E) -1 (E) -1-1 (E) -6-2 -14-2 -13-2 -12-2 -11-2
CR, CRE 32
50 Hz
ISO 9906 Annex A
0.0
0 0 4 8 12 16 20 24 28 32 36
Q [m/h] Q [l/s]
Best efficiency
Eta [%]
80
10
P2 [hp]
2.4
P2 [kW]
2.0 1.5
60 40 20 0
1.6
-9-2
0.8
-8-2
0.0
p [kPa]
200 160 120 80 40 0
H [m]
20 15 10 5 0 0
NPSH [m]
8 NPSH 6 4 2 0
12
16
20
24
28
32
36
Q [m/h]
36
10
P2 [hp]
2.4
P2 [kW]
2.0 1.5
Eta
p [kPa]
200 160 120 80 40 0
Q [m/h]
8 NPSH 6 4 2 0
20 15 10 5 0 0
H [m]
NPSH [m]
As the pump is sized on the basis of the highest possible flow, it is important always to have the duty point to the right on the efficiency curve (eta) in order to keep efficiency high when the flow drops.
12
16
20
24
28
32
36
Q [m/h]
Eta
TM00 9190 1303 TM02 6711 1403
Dimensional data When sizing a pump, take the following factors into account: Required flow and pressure at the draw-off point. Pressure loss as a result of height differences (Hgeo). Friction loss in the pipework (Hf). It may be necessary to account for pressure loss in connection with long pipes, bends or valves, etc. Best efficiency at the estimated duty point. NPSH value. For calculation of the NPSH value, see "Minimum inlet pressure, NPSH, page 22.
Hgeo NPSH Hf
Q [ m3 /h ]
Fig. 17 Best efficiency
Q [m/h]
19
H
Hn Hx nx
Q n n n ------- = -----Q n x x
nn
H n n 2 n ------- = ------ H n x x
Eta
Q
Qx Qn n ---- 1 x nx nn
Q P
Qx Qn nn nx Pn n n 3 ------ = ------ P n x x
TM00 8720 3496
Legend Hn Hx Qn Qx nn nx n x Rated head in metres Current head in metres Rated flow in m3/h Current flow in m3/h Rated motor speed in min-1 (nn = 2900 min-1) Current motor speed in min-1 Rated efficiency in % Current efficiency in %
In situations where it is not possible to select a duty point close to the 100 % curve the below affinity equations can be used. The head (H), the flow (Q) and the input power (P) are all the appropriate variables for the motor speed (n). Note: The approximated formulas apply on condition that the system characteristic remains unchanged for nn and nx and that it is based on the formula H = k x Q2, where k is a constant. The power equation implies that the pump efficiency is unchanged at the two speeds. In practice, this is not quite correct. To obtain a precise calculation of the power savings resulting from a reduction of pump speed, take into account the efficiencies of the frequency converter and the motor.
20
F (DIN)
P (PJE) A (oval)
TM02 1201 0601
21
tm (C)
190 180 170 160 150 140 130 120
Hv (m)
126 100 79 62 45 40 35 30 25 20 15 12 10 8,0 6,0 5,0 4,0 3,0 2,0 1,5 1,0 0,8 0,6
Hv
110 100 90 80 70 60 50 40 30 20 10 0
0,2 0,1
Note: To avoid cavitation, never select a pump with a duty point too far to the right on the NPSH curve. Always check the NPSH value of the pump at the highest possible flow.
22
0,4 0,3
CR, CRE 32
50 Hz
ISO 9906 Annex A
QH curve for the individual pump. The bold curves indicate the recommended duty range for best efficiency.
Number of stages. First figure: number of stages; second figure: number of reduced-diameter impellers.
The power curves indicate pump input power per stage. Curves are shown for complete (1/1) and for reduced-diameter (2/3) impellers.
The eta curve shows the efficiency of the pump. The eta curve is an average curve of all the pump types shown in the chart. The efficiency of pumps with reduced-diameter impellers is approx. 2 % lower than the eta curve shown in the chart.
10
P2 [hp]
2.4
P2 [kW]
2.0 1.5
Eta
p [kPa]
200 160 120 80 40 0
H [m]
20 15 10 5 0 0
The NPSH curve is an average curve for all the variants shown. When sizing the pumps, add a safety margin of at least 0.5 m.
TM02 7302 3103 TM01 2816 0303
12
16
20
24
28
32
36
Q [m/h]
QH curve for each individual impeller. Curves for complete (1/1) and reduced-diameter (2/3) impellers are shown.
Qmin [%]
30 20 10 0 40 60 80 100 120 140 160 180 t
CR
[C]
23
CRI, CRN 1s
p [kPa]
H [m]
220
CRI, CRN 1s
50 Hz
-36 ISO 9906 Annex A
2000
1600
160
140 1200
-21
-17
800
80 -12 60 -10 -8
-13 -11 -9
400
40
-7 -6 -5 -4 -3 -2
20
0 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Q [m/h]
0.30
0.00
0.05
0.10
0.15
0.20
0.25
Q [l/s]
Eta P2
P2 [hp]
0.04 0.03 0.02 0.01 0.00
P2 [kW]
0.03 0.02 0.01 0.00 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
Eta [%]
30 20 10 0
p [kPa]
60 40 20 0
H [m]
6 4 2 0 0.0 0.1
QH 2900 rpm
NPSH
2 0
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1.0
Q [m/h]
24
Technical data
Dimensional sketch
D2 D1
CRI, CRN 1s
B2
G 1/2 G 1/2
B1
P (PJE) G 1/2
CA (FlexiClamp)
4 x 13
89 105 140
22
34
180 210
32 85
22
250
162
32
141 109 16 141 109 16 141 109 17 141 109 17 141 109 18 141 109 18 141 109 18 141 109 19 141 109 19 141 109 19 141 109 20 141 109 20 141 109 22 141 109 23 141 109 23 141 109 26 141 109 27 141 109 28 141 109 31 141 109 32 141 109 33 141 109 34
CA is the code for the FlexiClamp coupling. CRI 1s pump models have a CA base up to the 1-19, suitable for use with two bolt oval flanges. CRI 1s pump models from 1-21 and above have a FGJ base for use with a four bolt DIN flange. CRN 1 models are available with either PJE of FGJ connections. CRI 1s and CRN 1s models with DIN flanges are rated DN25/32, PN25. The recommended connection size is DN25.
50
75
42.2
50
59
25
Performance curves
CRI, CRN, CRIE, CRNE 1
p [kPa]
H [m]
220 -36 (E) -33
2000
200
-30 (E)
-25 140 1200 -23 (E) -21 120 -19 (E) -17 -15 (E) 800 80 -12 60 -10 -8 400 40 -6 -5 20 -4 -3 (E) -2 0 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 -11 (E) -9 -7 (E) -13
100
0.0
0.1
0.2
0.3
0.4
0.5
0.6
P2 [kW]
0.06
0.03
20
0.00 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2
H [m]
6 QH 2900 rpm
NPSH 0 0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 0
Q [m/h]
26
Technical data
Dimensional sketch
D2 D1
B2
G 1/2 G 1/2
B1
P (PJE) G 1/2
CA (FlexiClamp)
4 x 13
89 105 140
22
34
180 210
32 85
22
250
162
32
141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 178 110 178 110 178 110 178 110 178 110
141 140
141 140
141 140
CA is the code for the FlexiClamp coupling. CRI(E) 1 pump models have a CA base up to the 1-19, suitable for use with two bolt oval flanges. CRI(E) 1 pump models from 1-21 and above have a FGJ base for use with a four bolt DIN flange. CRN(E) 1 models are available with either PJE of FGJ connections. CRI(E) 1 & CRN 1 models with DIN flanges are rated DN25/32, PN25. The recommended connection size is DN25.
50
75
42.2
50
59
27
Performance curves
CRI, CRN, CRIE, CRNE 3
p [kPa]
H [m]
240 220 -36 (E)
50 Hz
ISO 9906 Annex A
2000
200 180
1600
160 140
1200
120 -17 100 -15 (E) -12 -10 (E) 60 -8 -9 -7 (E) -6 -4 20 -2 -5 (E) -3 -13 -11
800
80
400
40
0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4
0.0
0.2
0.4
0.6
0.8
1.0
1.2
P2 [kW]
0.09 0.06 0.03 0.00 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 4.4
H [m]
6 4 2 0
QH 2900 rpm
NPSH
0.0
0.4
0.8
1.2
1.6
2.0
2.4
2.8
3.2
3.6
4.0
4.4
Q [m/h]
28
Technical data
Dimensional sketch
D2 D1
B2
G 1/2 G 1/2
B1
P (PJE) G 1/2
CA (FlexiClamp)
4 x 13
89 105 140
22
34
180 210
32 85
22
250
162
32
141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 141 109 178 110 178 110 178 110 178 110 178 110 178 110 178 110 198 120 198 120 198 120
178 167
178 167
198 177
CA is the code for the FlexiClamp coupling. CRI(E) 3 pump models have a CA base up to the 3-15, suitable for use with two bolt oval flanges. CRI(E) 3 pump models from 3-17 and above have a FGJ base for use with a four bolt DIN flange. CRN(E) 3 models are available with either PJE of FGJ connections. CRI(E) 3 & CRN 3 models with DIN flanges are rated DN25/32, PN25. The recommended connection size is DN25.
50
75
42.2
50
59
29
Performance curves
CRI, CRN, CRIE, CRNE 5
p [kPa]
2400
H [m]
260 -36 (E) 240 220
2000
200 180
-29 (E)
1600
160 140
-20 (E) -18 -16 (E) -15 -13 -11 -9 -8 (E) -6 -4 (E) -7 -5
1200
120 100
800
80 60
400
40 20
-3 -2 (E)
0 0 1 2 3 4 5 6 7 8
Q [m/h]
2.5
0.0
0.5
1.0
1.5
2.0
P2 [kW]
0.15 0.10 0.05 0.00 0 1 QH 2900 rpm 2 3 4 5 6
Eta P2
40 20 0 7 8 9Q
H [m]
6 4 2 0 0
NPSH
1 0 1 2 3 4 5 6 7 8 9Q
[m/h]
30
Technical data
Dimensional sketch
D2 D1
B2
B1
P (PJE) G 1/2
CA (FlexiClamp)
4 x 13
22
34
180 210
32 85
22
250
162
32
141 109 141 109 141 109 141 109 141 109 141 109 141 109 178 110 178 110 178 110 178 110 178 110 178 110 178 110 178 110 198 120 198 120 220 134 220 134 220 134 220 134
CA is the code for the FlexiClamp coupling. CRI(E) 5 pump models have a CA base up to the 5-12, suitable for use with two bolt oval flanges. CRI(E) 5 pump models from 5-13 and above have a FGJ base for use with a four bolt DIN flange. CRN(E) 5 models are available with either PJE of FGJ connections. CRI(E) 5 & CRN 5 models with DIN flanges are rated DN25/32, PN25. The recommended connection size is DN32.
50
75
42.2
50
59
31
Performance curves
CRI, CRN, CRIE, CRNE 10
p [kPa]
H [m]
240 -22 (E) 220 -20 200 -18 180
2000
1600
1200
-12 (E) 120 -10 100 -9 (E) -8 80 60 -7 -6 (E) -5 -4 (E) -3 (E) -2 (E) -1 (E)
800
400
40 20
0 0 1 2 3 4 5 6 7 8 9 10 11 12
Q [m/h]
3.5
0.0
0.5
1.0
1.5
2.0
2.5
3.0
P2 [kW]
0.4 0.3 0.2 0.1 0.0 0 1 2 3 4 5 6 7 8 9 10 11 12 Eta P2
H [m]
12 8 4 NPSH 0 0 1 2 3 4 5 6 7 8 9 10 11 12 2900 rpm
6 4 2 0
TM02 7297 3605
Q [m/h]
32
Technical data
Dimensional sketch
D2 D1
B2
G 1/2 G 1/2 D3 P (PJE) B1 G 1/2 G 1/2 FGJ (DIN-ANSI-JIS) PN 16-25 / DN 40 18.5 x 23.5 202 115 150 87 26 26 4 x 13 50 215 248 CA (Flexiclamp)
4 x 13
80
80
80
215 248
130 200
141 109 141 109 141 109 178 110 178 110 178 110 198 120 198 120 198 120 220 134 220 134
141 140 178 167 178 167 178 167 178 167
220 134 300 220 134 300 220 134 300 220 134 300
CA is the code for the FlexiClamp coupling. CRI(E) 10 pump models have a CA base up to the 10-9, suitable for use with two bolt oval flanges. CRI(E) 10 pump models from 10-10 and above have a FGJ base for use with a four bolt DIN flange. CRN(E) models are available with either PJE of FGJ connections. CRI(E) 10 & CRN 10 models with DIN flanges are rated DN40, PN16 up to and including model 10-16, and PN25 above.
60.1
26
33
Performance curves
CRI, CRN, CRIE, CRNE 15
p [kPa]
H [m]
240 220 -17 (E)
2000
200 180
-14 (E)
-12 1600 160 140 1200 120 100 800 80 -5 (E) 60 400 40 -2 (E) 20 0 0 0 2 4 6 8 10 12 14 16 18 20 22 -1 (E) -4 -3 (E) -10 -9 (E) -8 -7 (E) -6
P2 [kW]
0.8 0.6 0.4 0.2 0.0 0 2 4 6 8 10 12 14 16 18 20 22
H [m]
15 10 5 NPSH 0 0 2 4 6 8 10 12 14 16 18 20 22 2900 rpm
6 4
TM02 7299 3605
2 0
Q [m/h]
34
Technical data
Dimensional sketch
D2 D1
B2
G 1/2 G 1/2 D3 FGJ (DIN-ANSI-JIS) PN 16-25 / DN50 G 1/2 18.5 x 21.8 202 127 165 87 26 26 CA
P (PJE) B1 G 1/2 4 x 13
90
90
90
215 248
130 200
141 109 178 110 198 120 220 134 220 134
178 167
178 167 270 198 177 270 220 188 270 220 188 298 220 188 298
220 134 300 220 134 300 220 134 300 220 134 300
260 172 350 123 260 172 350 126 260 172 350 130 320 197 350 149
CRI(E) 15 pump models have a FGJ base for use with a four bolt DIN flange. CRN(E) 15 models are available with either PJE of FGJ connections. CRI(E) 15 & CRN 15 models with DIN flanges are rated DN50, PN16 up to and including model 15-10, and PN25 above.
60.1
26
35
Performance curves
CRI, CRN, CRIE, CRNE 20
p [kPa]
2400
H [m]
260 240 220 -14 (E) -17 (E)
2000
1600
1200
120 100
-8 -7 (E) -6
800
80 60
-5 (E) -4 -3 (E)
400
40 -2 (E) 20 -1 (E)
0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
Q [m/h]
8
P2 [kW]
1.6 1.2 0.8 0.4 0.0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28
H [m]
15 10 5 NPSH 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 2900 rpm
6 4 2 0
TM02 7301 3605
Q [m/h]
36
Technical data
Dimensional sketch
D2 D1
B2
G 1/2 G 1/2 D3 FGJ (DIN-ANSI-JIS) PN 16-25 / DN50 G 1/2 18.5 x 21.8 202 127 165 87 26 26 CA
P (PJE) B1 G 1/2 4 x 13
90
90
90
215 248
130 200
220 134 300 220 134 300 220 134 300 220 134 300
260 172 350 119 260 172 350 123 320 197 350 140 320 197 350 144 320 197 350 179
258 359 350 191 313 377 350 214 313 377 350 254
CRI(E) 20 pump models have a FGJ base for use with a four bolt DIN flange. CRN(E) 20 models are available with either PJE of FGJ connections. CRI(E) 20 & CRN 20 models with DIN flanges are rated DN50, PN16 up to and including model 20-10, and PN25 above.
60.1
26
37
Performance curves
CR, CRE 32
CR, CRE 32
p H [MPa] [m]
280 260 2.4 240 220 2.0 200 180 1.6 160 140 1.2 120 100 0.8 80 60 0.4 40 20 0.0 0 0 4 8 12 16 20 24 28 32 -14 -13 -12 (E) -11 -10 (E) -10-2 -9 -8 (E) -7 -7-2 -6 (E) -5 -5-2 -4 (E) -4-2 -3 (E) -3-2 -2 (E) -2-2 (E) -1 (E) -1-1 (E) -6-2 -9-2 -8-2 -14-2 -13-2 -12-2 -11-2
CR, CRE 32
50 Hz
ISO 9906 Annex A
36
10
P2 P2 [hp] [kW]
2.0 2.4 1.5 1.6 0.8 0.0 1.0 0.5 0.0 0 4 8 12 16 20 24 28
Eta
p [kPa]
200 160 120
32
36
H [m]
20 15 10 5 0 0
80 40 0
12
16
20
24
28
32
36
Q [m/h]
38
Technical data
Dimensional sketch
D2 D1
CR, CRE 32
B2
105
G 1/2
30
4 x 14 74 240 298
645 1036 220 134 300 645 1036 220 134 300 715 1106 220 134 300 715 1106 220 134 300 895 1394 260 172 350 895 1394 260 172 350 965 1464 260 172 350 965 1464 260 172 350 1035 1513 320 197 350 1035 1513 320 197 350 1105 1583 320 197 350 1105 1583 320 197 350 1175 1693 320 197 350 1175 1693 320 197 350 1245 1763 320 197 350 1245 1763 320 197 350 1315 1925 363 262 350 1315 1925 363 262 350 1385 1995 363 262 350 1385 1995 363 262 350 1455 2101 415 300 400 1455 2101 415 300 400 1525 2171 415 300 400 1525 2171 415 300 400
645 1036 220 188 298 715 1106 220 188 298
For information about maximum operating pressure, please see page 17.
39
Performance curves
CRN, CRNE 32
CRN, CRNE 32
p H [MPa] [m]
280 260 2.4 240 220 2.0 200 180 1.6 160 140 1.2 120 100 0.8 80 60 0.4 40 20 0.0 0 0 4 8 12 16 20 24 28 -14 -13 -12 (E) -11 -10 (E) -9 -8 (E) -8-2 -7 -7-2 -6 (E) -6-2 -5 -5-2 -4 (E) -4-2 -3 (E) -3-2 -2 (E) -2-2 (E) -1 (E) -1-1 (E) -14-2 -13-2 -12-2 -11-2 -10-2 -9-2
CRN, CRNE 32
50 Hz
ISO 9906 Annex A
32
36
10
P2 P2 [hp] [kW]
2.0 2.4 1.5 1.6 0.8 0.0 1.0 0.5 0.0 0 4 8 12 16 20 24 28
Eta
32
36
p [kPa]
160 120 80 40 0
H [m]
20 15 10 5 0 0
12
16
20
24
28
32
36
Q [m/h]
40
Technical data
Dimensional sketch
D2 D1
CRN, CRNE 32
B2
105
G 1/2
30
4 x 14
74 240 298
645 1036 220 134 300 645 1036 220 134 300 715 1106 220 134 300 715 1106 220 134 300 895 1394 260 172 350 895 1394 260 172 350 965 1464 260 172 350 965 1464 260 172 350 1035 1513 320 197 350 1035 1513 320 197 350 1105 1583 320 197 350 1105 1583 320 197 350 1175 1693 320 197 350 1175 1693 320 197 350 1245 1763 320 197 350 1245 1763 320 197 350 1315 1925 363 262 350 1315 1925 363 262 350 1385 1995 363 262 350 1385 1995 363 262 350 1455 2101 415 300 400 1455 2101 415 300 400 1525 2171 415 300 400 1525 2171 415 300 400
645 1036 220 188 298 715 1106 220 188 298
For information about maximum operating pressure, please see page 17.
41
Performance curves
CR, CRE 45
CR, CRE 45
p H [MPa] [m]
340 3.2 -13-2 320 -12 300 2.8 280 260 2.4 240 -9 220 2.0 200 180 1.6 160 140 1.2 -5 (E) 120 100 0.8 80 60 0.4 40 -1 (E) 20 0.0 0 0 5 10 15 20 25 30 35 40 45 50 -4 (E) -4-2 -3 (E) -3-2 -2 (E) -2-2 (E) -1-1 (E) -5-2 -8 -8-2 -7 -7-2 -6 (E) -6-2 -9-2 -11 -10 -10-2 -12-2 -11-2
CR, CRE 45
50 Hz
ISO 9906 Annex A
55
Q [m/h]
16
10
12
14
P2 P2 [hp] [kW]
4 4 2 1 0 0 0 5 10 15 20 25 30 35 40 45 50 55 3 2 Eta
Q [l/s]
Eta [%]
80 60 40 20 0
P2 1/1 P2 2/3
p H [kPa] [m]
25 200 150 100 50 0 20 15 10 5 0
Q [m/h]
NPSH [m]
5 4 3
TM02 7304 3605
2 1 0 0 5 10 15 20 25 30 35 40 45 50 55
Q [m/h]
42
Technical data
Dimensional sketch
D2 D1
CR, CRE 45
B2
G 1/2 140
80 266 331
639 1030 220 134 300 639 1030 220 134 300 829 1328 260 172 350 829 1328 260 172 350 909 1387 320 197 350 909 1387 320 197 350 989 1507 320 197 350 989 1507 320 197 350 1069 1679 363 262 350 1069 1679 363 262 350 1149 1795 415 300 400 1149 1795 415 300 400 1229 1875 415 300 400 1229 1875 415 300 400 1309 1955 415 300 400 1309 2012 415 300 400 1389 2092 415 300 400 1389 2092 415 300 400 1469 2178 442 325 450 1469 2178 442 325 450 1549 2258 442 325 450 1549 2258 442 325 450 1629 2338 442 325 450
639 1030 220 188 298 639 1030 220 188 298 829 1278 258 359 350 909 1370 313 377 350 989 1488 313 377 350 1069 1594 351 399 350
For information about maximum operating pressure, please see page 17.
45
4 x 14
43
Performance curves
CRN, CRNE 45
CRN, CRNE 45
p H [MPa] [m]
340 3.2 -13-2 320 -12 300 2.8 280 260 2.4 240 -9 220 2.0 200 180 1.6 160 140 1.2 -5 (E) 120 100 0.8 80 60 0.4 40 -1 (E) 20 0.0 0 0 5 10 15 20 25 30 35 40 45 -4 (E) -4-2 -3 (E) -3-2 -2 (E) -2-2 (E) -1-1 (E) -5-2 -8 -8-2 -7 -7-2 -6 (E) -6-2 -9-2 -11 -10 -10-2 -12-2 -11-2
CRN, CRNE 45
50 Hz
ISO 9906 Annex A
50
55
Q [m/h]
16
10
12
14
P2 P2 [hp] [kW]
4 4 2 1 0 0 0 5 10 15 20 25 30 35 40 45 50 55 3 2 Eta
Q [l/s]
Eta [%]
80 60 40 20 0
P2 1/1 P2 2/3
H p [kPa] [m]
25 200 150 100 50 0 20 15 10 5 0
Q [m/h]
NPSH [m]
5 4 3
TM02 7305 3605
2 1 0 0 5 10 15 20 25 30 35 40 45 50 55
Q [m/h]
44
Technical data
Dimensional sketch
D2 D1
CRN, CRNE 45
B2
G 1/2 140
80 266 331
639 1030 220 134 300 639 1030 220 134 300 829 1328 260 172 350 829 1328 260 172 350 909 1387 320 197 350 909 1387 320 197 350 989 1507 320 197 350 989 1507 320 197 350 1069 1679 363 262 350 1069 1679 363 262 350 1149 1795 415 300 400 1149 1795 415 300 400 1229 1875 415 300 400 1229 1875 415 300 400 1309 1955 415 300 400 1309 2012 415 300 400 1389 2092 415 300 400 1389 2092 415 300 400 1469 2178 442 325 450 1469 2178 442 325 450 1549 2258 442 325 450 1549 2258 442 325 450 1629 2338 442 325 450
639 1030 220 188 298 639 1030 220 188 298 829 1278 258 359 350 909 1370 313 377 350 989 1488 313 377 350 1069 1594 351 399 350
For information about maximum operating pressure, please see page 17.
45
4 x 14
45
Performance curves
CR, CRE 64
CR, CRE 64
p H [MPa] [m]
240 -8-1 220 2.0 -7 200 180 1.6 160 -5 140 1.2 120 100 -3 0.8 80 60 0.4 40 -1 (E) 20 0.0 0 0 10 20 30 40 50 60 -1-1 (E) -3-1 (E) -3-2 -2 (E) -2-1 -2-2 (E) -5-1 -5-2 -4 (E) -4-1 -4-2 (E) -7-1 -7-2 -6 -6-1 -6-2 -8-2
CR, CRE 64
50 Hz
ISO 9906 Annex A
70
80
Q [m/h] Q [l/s]
10
15
20
P2 P2 [hp] [kW]
10 8 6 4 2 0 2 0 0 10 20 30 40 50 60 70 80 8 6 4
Eta [%]
80 60 40 20 0
p [kPa]
300 200
H [m]
32 24 16 QH 2900 rpm 1/1
Q [m/h]
NPSH [m]
8 6 4 2 0
TM02 7306 3605
100 0
8 0 0 10 20 30 40 50 60 70 80
Q [m/h]
46
Technical data
Dimensional sketch
D2 D1 F (DIN) PN25-40/DN100 8 x 22 B2
CR, CRE 64
D3 G 1/2
45
100
B1
G 1/2
8 x 18
G 1/2 140
G 1/2
45
100
4 x 14
266 331
644 1035 220 134 300 754 1253 260 172 350 754 1253 260 172 350 836 1314 320 197 350 836 1314 320 197 350 836 1354 320 197 350 919 1437 320 197 350 919 1529 363 262 350 919 1529 363 262 350 1001 1647 415 300 400 1001 1647 415 300 400 1001 1647 415 300 400 1084 1730 415 300 400 1084 1787 415 300 400 1084 1787 415 300 400 1166 1869 415 300 400 1166 1869 415 300 400 1166 1875 442 325 450 1249 1958 442 325 450 1249 1958 442 325 450
644 1035 220 188 298 754 1203 258 359 350 836 1297 313 377 350 919 1418 313 377 350 919 1444 351 399 350
For information about maximum operating pressure, please see page 17.
47
Performance curves
CRN, CRNE 64
CRN, CRNE 64
p H [MPa] [m]
240 -8-1 220 2.0 -7 200 180 1.6 160 -5 140 1.2 120 100 -3 0.8 80 60 0.4 40 -1 (E) 20 0.0 0 0 10 20 30 40 50 60 -1-1 (E) -3-1 (E) -3-2 -2 (E) -2-1 -2-2 (E) -5-1 -5-2 -4 (E) -4-1 -4-2 (E) -7-1 -7-2 -6 -6-1 -6-2 -8-2
CRN, CRNE 64
50 Hz
ISO 9906 Annex A
70
Q [m/h] Q [l/s]
10
15
20
P2 P2 [hp] [kW]
10 8 6 4 2 0 2 0 0 10 20 30 40 50 60 70 8 6 4
Eta [%]
80 60 40 20 0
p [kPa]
300 200
H [m]
32 24 16 QH 2900 rpm 1/1
Q [m/h]
NPSH [m]
8 6 4 2 0
TM02 7307 3605
100 0
8 0 0 10 20 30 40 50 60 70
Q [m/h]
48
Technical data
Dimensional sketch
D2 D1 F (DIN) PN25-40/DN100 8 x 22 B2
CRN, CRNE 64
D3 G 1/2
45
100
B1
G 1/2
8 x 18
G 1/2 140
G 1/2
45
100
4 x 14
266 331
644 1035 220 134 300 754 1253 260 172 350 754 1253 260 172 350 836 1314 320 197 350 836 1314 320 197 350 836 1354 320 197 350 919 1437 320 197 350 919 1529 363 262 350 919 1529 363 262 350 1001 1647 415 300 400 1001 1647 415 300 400 1001 1647 415 300 400 1084 1730 415 300 400 1084 1787 415 300 400 1084 1787 415 300 400 1166 1869 415 300 400 1166 1869 415 300 400 1166 1875 442 325 450 1249 1958 442 325 450 1249 1958 442 325 450
644 1035 220 188 298 754 1203 258 359 350 836 1297 313 377 350 919 1418 313 377 350 919 1444 351 399 350
For information about maximum operating pressure, please see page 17.
49
Performance curves
CR, CRE 90
CR, CRE 90
p H [MPa] [m]
210 2.0 200 190 1.8 180 170 1.6 160 150 1.4 140 130 1.2 120 110 1.0 100 90 0.8 80 70 0.6 60 50 0.4 40 30 0.2 20 10 0.0 0 0 10 20 30 40 50 60 70 80 90 100 110 -2-2 (E) -1 (E) -1-1 (E) -3-2 (E) -2 (E) -3 (E) -4-2 -5-2 -4 -6-2 -5 -6
CR, CRE 90
50 Hz
ISO 9906 Annex A
10
15
20
25
30
P2 P2 [hp] [kW]
10 8 6 4 2 0 2 0 0 10 20 30 40 50 60 70 80 90 100 110 8 6 4
p [kPa]
300 200 100 0
H [m]
40 QH 2900 rpm 1/1 30 QH 2900 rpm 2/3 20 10 0 0 10 20 30 40 50 60 70 80 90 100 110 NPSH
4 2 0
TM02 7308 3605
Q [m/h]
50
Technical data
Dimensional sketch
D2 D1 F (DIN) PN25-40/DN100 8 x 22 B2
CR, CRE 90
45
D3 G 1/2
100
B1
G 1/2
G 1/2 140
G 1/2
45
100
4 x 14
280 348
773 1272 260 172 350 773 1251 320 197 350 865 1383 320 197 350 865 1475 363 262 350 957 1603 415 300 400 957 1603 415 300 400 1049 1752 415 300 400 1049 1752 415 300 400 1141 1850 442 325 450 1141 1850 442 325 450
773 1222 258 359 350 773 1234 313 377 350 865 1364 313 377 350 865 1390 351 399 350 -
For information about maximum operating pressure, please see page 17.
51
Performance curves
CRN, CRNE 90
CRN, CRNE 90
p H [MPa] [m]
210 2.0 200 190 1.8 180 170 1.6 160 150 1.4 140 130 1.2 120 110 1.0 100 90 0.8 80 70 0.6 60 50 0.4 40 30 0.2 20 10 0.0 0 0 10 20 30 40 50 60 70 80 90 100 110 -2-2 (E) -1 (E) -1-1 (E) -3-2 (E) -2 (E) -3 (E) -4-2 -5-2 -4 -6-2 -5 -6
CRN, CRNE 90
50 Hz
ISO 9906 Annex A
10
15
20
25
30
P2 P2 [hp] [kW]
10 8 6 4 2 0 2 0 0 10 20 30 40 50 60 70 80 90 100 110 8 6 4
p [kPa]
300 200 100 0
H [m]
40 QH 2900 rpm 1/1 30 QH 2900 rpm 2/3 20 10 0 0 10 20 30 40 50 60 70 80 90 100 110 NPSH
4 2 0
TM02 7309 3605
Q [m/h]
52
Technical data
Dimensional sketch
D2 D1 F (DIN) PN25-40/DN100 8 x 22 B2
CRN, CRNE 90
D3 G 1/2
45
100
B1
G 1/2
8 x 18
G 1/2 140
G 1/2
45
100
4 x 14
280 348
773 1272 260 172 350 773 1251 320 197 350 865 1383 320 197 350 865 1475 363 262 350 957 1603 415 300 400 957 1603 415 300 400 1049 1752 415 300 400 1049 1752 415 300 400 1141 1850 442 325 450 1141 1850 442 325 450
773 1222 258 359 350 773 1234 313 377 350 865 1364 313 377 350 865 1390 351 399 350 -
For information about maximum operating pressure, please see page 17.
53
Performance curves
CR 120
CR 120
p H [MPa] [m]
210 2.0 200 190 1.8 180 170 1.6 160 150 1.4 140 130 1.2 120 110 1.0 100 90 0.8 80 70 0.6 60 50 0.4 40 -1 30 0.2 20 10 0.0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 -2 -2-1 -3 -4-1 -5-1 -6-1 -7
CR 120
50 Hz
ISO 9906 Annex A
10
15
20
25
30
35
40
P2 P2 [hp] [kW]
20 15 10 5 0 16 12 8 4 0 0 10 20 30 40 50 60 70 80 90 100
Eta
110
120
130
140
150
p [kPa]
300 200 100 0
H [m]
30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 QH 2900 rpm 1/1 QH 2900 rpm 2/3
12 8 4 0
TM03 8743 2407
NPSH
Q [m/h]
54
Technical data
Dimensional sketch
CR 120
260 172 350 320 197 350 363 262 350 415 300 400 415 300 400 442 325 450 495 392 550 555 432 550
For information about maximum operating pressure, please see page 17.
55
Performance curves
CRN 120
CRN 120
p H [MPa] [m]
210 2.0 200 190 1.8 180 170 1.6 160 150 1.4 140 130 1.2 120 110 1.0 100 90 0.8 80 70 0.6 60 50 0.4 40 -1 30 0.2 20 10 0.0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 -2 -2-1 -3 -4-1 -5-1 -6-1 -7
CRN 120
50 Hz
ISO 9906 Annex A
10
15
20
25
30
35
40
P2 P2 [hp] [kW]
20 15 10 5 0 16 12 8 4 0 0 10 20 30 40 50 60 70 80 90 100
Eta
110
120
130
140
150
p [kPa]
300 200 100 0
H [m]
30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 QH 2900 rpm 1/1 QH 2900 rpm 2/3
12 8 4 0
TM03 8744 2407
NPSH
Q [m/h]
56
Technical data
Dimensional sketch
CRN 120
260 172 350 320 197 350 363 262 350 415 300 400 415 300 400 442 325 450 495 392 550 555 432 550
For information about maximum operating pressure, please see page 17.
57
Performance curves
CR 150
CR 150
p H [MPa] [m]
200 190 1.8 180 170 1.6 160 150 1.4 -5-2 140 130 1.2 120 110 1.0 100 90 0.8 80 70 0.6 60 50 0.4 40 30 0.2 20 10 0.0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 -1 -1-1 -2-1 -3-2 -3 -4-1 -6
CR 150
50 Hz
ISO 9906 Annex A
10
15
20
25
30
35
40
45
P2 P2 [hp] [kW]
20 15 10 5 0 16 12 8 4 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Eta
p [kPa]
300 200 100 0
H [m]
30 20 10 0 0
NPSH
4 0
10
20
30
40
50
60
70
80
90
Q [m/h]
58
Technical data
Dimensional sketch
CR 150
260 172 350 320 197 350 363 262 350 415 300 400 415 300 400 442 325 450 495 392 550 555 432 550
For information about maximum operating pressure, please see page 17.
59
Performance curves
CRN 150
CRN 150
p H [MPa] [m]
200 190 1.8 180 170 1.6 160 150 1.4 -5-2 140 130 1.2 120 110 1.0 100 90 0.8 80 70 0.6 60 50 0.4 40 30 0.2 20 10 0.0 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 -1 -1-1 -2-1 -3-2 -3 -4-1 -6
CRN 150
50 Hz
ISO 9906 Annex A
10
15
20
25
30
35
40
45
P2 P2 [hp] [kW]
20 15 10 5 0 16 12 8 4 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 Eta
p [kPa]
300 200 100 0
H [m]
30 20 10 0 0
NPSH
4 0
10
20
30
40
50
60
70
80
90
Q [m/h]
60
Technical data
Dimensional sketch
CRN 150
260 172 350 320 197 350 363 262 350 415 300 400 415 300 400 442 325 450 495 392 550 555 432 550
For information about maximum operating pressure, please see page 17.
61
CRI, CRN
Dimensions
Pump models: CRI/CRN 1, 3, 5, 10, 15, 20
Motor [kW] 0.37 0.55 0.75 1.1 1.5 2.2 B2 191 231 231 281 321 321 D1 141 141 141 178 178 178 D2 133 133 133 139 139 139
B2
D1
D1
D2
62
Motor data
Standard motors for CR, CRI, CRN, 50 Hz
Motor Frame P2 size [kW] 0.37 0.55 0.75 1.1 1.5 2.2 3.0 4.0 5.5 7.5 11 15 18.5 22 30 37 45 55 75 71 71 80 80 90 90 100 112 132 132 160 160 160 180 200 200 225 250 280 Standard voltage I 1/1 [A] [V] 220-240 /380-415Y 220-240 /380-415Y 220-240 /380-415Y 220-240 /380-415Y 220-240 /380-415Y 380-415 380-415 380-415 380-415 380-415 380-415 1.7/1 2.5/1.4 3.3/1.9 4.5/2.6 5.5/3.2 4.5-4.5 6.3-6.3 8-8 0.80-0.70 0.80-0.70 0.81-0.71 0.84-0.76 0.87-0.82 0.89-0.87 0.87-0.82 0.88-0.84 78.5 80 81 82.8 85.5 87.5 87.5 89 90 89.5 91.4 91.5 92.5 94 93.5 94 95 95.5 95 8.5-9.2/4.9-5.3 12-13/6.9-7.5 Cos 1/1 [%] Speed Istart [rpm] 2850-2880 2830-2850 Sound pressure [dBA] 53 53 53 53 58 60 59.5 63 62 68 70
MG
19.1-20.5/11.0-11.8 2840-2870 28.5-31.5/16.3-17.9 2820-2860 46.3-50.7/26.8-29.3 2890-2910 37.8-42.3 52.9-58.0 89.6-98.4 119.8-131.0 152-168.7 156.2-171.2 185.5/106.4 220.5/128.8 277.2/158.4 371/213.5 460.8/266.4 562.1/324.9 632.4/367.2 896-832/518-481 2890-2910 2900-2920 2910-2930 2910-2930 2900-2920 2920-2930 2945 2940 2955 2960 2960 2965 2975 2975
Siemens 380-415 /660-690Y 26.5/15.2 0.90-0.90 380-415 /660-690Y 31.5/18.4 0.92-0.92 380-415 /660-690Y 380-415 /660-690Y 380-415 /660-690Y 380-415 /660-690Y 380-415/660-690Y 380-415/660-690Y 38.5/22 53/30.5 64/37 77/44.5 93/54 128/74 0.88-0.88 0.88-0.88 0.89-0.89 0.89-0.89 0.90-0.90 0.89-0.89 63 63 67 71 71 71 71 73
TM03 1710 2805
MGE
73
* Pumps are normally fitted with single-phase MGE motors. Previous dimensions tables show pumps with single-phase MGE motors
63
Motor starting
Motor starting
Motors 4kW and above are generally suitable for star delta starting, however, it is recommended to start Grundfos pump products direct on line as there is no benefit in star delta starting with low inertia loads, even for kW ratings up to 90kW. When direct on line starting low inertia loads, the run up time to full speed is approximately 0.1 seconds. After this period the motor is running at full speed and the current is down to the full load current or less, depending on the load. The full direct on line starting current (LRC) is only seen for less than 0.1 seconds. Direct on line starting currents of this duration do not cause significant heating of the supply cable when sized according to normal practice. When starting star delta low inertia loads, the low moment of inertia of the pump is insufficient to maintain the motor at the star speed during the translation period from star into delta (typically 0.1 seconds). During the transistion period the motor slows down to approximately 50% of the star speed. When the motor is then reconnected in delta, the full direct on line starting current then appears. In summary, when star delta starting two transients are seen on the supply. The first is the normal star starting current (0.33 x LRC), and the second being the full direct on line starting current (6 to 9 x FLC). Therefore, star delta starting of low inertia loads does not eliminate or reduce the direct on line starting current. Direct on line starting of low inertia loads simplifies panel design and reduces costs. Please note: For high inertia loads, where the run up time is long, motors should be star delta started.
64
Pumped liquids
Pumped liquids
Thin, non-explosive liquids, not containing solid particles or fibres. The liquid must not chemically attack the pump materials. When pumping liquids with a density and/or viscosity higher than that of water, use oversized motors, if required. Whether a pump is suitable for a particular liquid depends on a number of factors of which the most important are the chloride content, pH value, temperature and content of chemicals, oils, etc. Please note that aggressive liquids, such as sea water and some acids, may attack or dissolve the protective oxide film of the stainless steel and thus cause corrosion. The CR(E), CRI(E), CRN(E) pump types are suitable for the following liquids: CR(E), CRI(E) CR(E), CRI(E) pumps are suitable for non-corrosive liquids. Use CR(E), CRI(E) pumps for liquid transfer, circulation and pressure boosting of cold or hot clean water. CRN(E) CRN(E) pumps are suitable for industrial liquids. Use CRN(E) pumps in systems where all parts in contact with the liquid must be made of high-grade stainless steel. CRT(E) CRT(E) pumps are suitable for these liquids: saline liquids hypochlorites acids.
Pumped liquid Acetic acid, CH3COOH Acetone, CH3COCH3 Alkaline degreasing agent Ammonium bicarbonate, NH4HCO3 Ammonium hydroxide, NH4OH Aviation fuel Benzoic acid, C 6H5COOH Boiler water Calcareous water Calcium acetate (as coolant with inhibitor) Ca(CH3COO)2 Calcium hydroxide, Ca(OH)2 Chloride-containing water Chromic acid, H2CrO 4 Citric acid, HOC(CH2CO2H)2COOH Completely desalinated water (demineralized water) Note 1, F D, F E 1, 3, 4, F H F D, E E F H H Liquid concentration, liquid temperature 5 %, +20 C 100 %, +20 C 20 %, +30 C 20 %, +40 C 100 %, +20 C 0.5 %, +20 C < +120 C +120 C - +180 C < +90 C 30 %, +50 C Saturated solution, +50 C < +30 C, max. 500 ppm 1 %, +20 C 5 %, +40 C +120 C
For saline or chloride-containing liquids such as sea water or for oxidizing agents such as hypochlorites, Grundfos offers CRT(E) pumps made of titanium. See separate data booklet on CRT(E), accessible in WebCAPS page 75.
F H 1 2 3 4
65
Pumped liquids
Liquid concentration, liquid temperature 120 C 10 %, +50 C 100 %, +80 C 100 %, +20 C < +120 C 100 %, +20 C 50 %, +50 C 5 %, +20 C 50 %, +50 C 100 %, +100 C 100 %, +100 C 100 %, +20 C 10 %, +20 C 100 %, +20 C 100 %, +20 C 100 %, +80 C 100 %, +80 C 1 %, +20 C < +100 C 100 %, +80 C 1 %, +20 C < +100 C 100 %, +80 C 100 %, +20 C 20 %, +20 C 100 %, +20 C 50 %, +90 C 20 %, +50 C 30 %, +50 C 20 %, +50 C 5 %, +20 C 100 %, +80 C 0.1 %, +20 C 100 % 10 %, +60 C 30 %, < +5 C, pH > 8 20 %, +50 C 0.1 %, +20 C 10 %, +60 C 10 %, +60 C 10 %, +60 C < +120 C 100 %, +80 C 1 %, +20 C 1 %, +20 C Approx. 2 ppm free chlorine (Cl2)
Pumped liquid Condensate Copper sulphate, CuSO 4 Corn oil Diesel oil Domestic hot water (potable water) Ethanol (ethyl alcohol), C2H5OH Ethylene glycol, HOCH2CH2OH Formic acid, HCOOH Glycerine (glycerol), OHCH 2CH(OH)CH2OH Hydraulic oil (mineral) Hydraulic oil (synthetic) Isopropyl alcohol, CH3CHOHCH3 Lactic acid, CH3CH(OH)COOH Linoleic acid, C17H31COOH Methanol (methyl alcohol), CH3OH Motor oil Naphthalene, C10H8 Nitric acid, HNO3 Oil-containing water Olive oil Oxalic acid, (COOH)2 Ozone-containing water, (O3) Peanut oil Petrol Phosphoric acid, H3PO4 Propanol, C3H7OH Propylene glycol, CH 3CH(OH)CH2OH Potassium carbonate, K2CO3 Potassium formate (as coolant with inhibitor), KOOCH Potassium hydroxide, KOH Potassium permanganate, KMnO4 Rape seed oil Salicylic acid, C6H4(OH)COOH Silicone oil Sodium bicarbonate, NaHCO 3 Sodium chloride (as coolant), NaCl Sodium hydroxide, NaOH Sodium hypochlorite, NaOCl Sodium nitrate, NaNO3 Sodium phosphate, Na 3PO4 Sodium sulphate, Na 2SO4 Softened water Soya oil Sulphuric acid, H2SO4 Sulphurous acid, H 2SO3 Unsalted swimming pool water
Note E D, E, 3 2, 3, 4, F 1, F D, E D, E E, 2, 3 E, 2, 3 1, F E, H E, 3 1, F E, 2, 3 E, H F D, E, 3 H D, E, 3 1, 3, 4, F E 1, F D, E E D, E E D, E, 3 H E, 3 E D, E E F E E, H E, H D, E, 3 F -
CR(E), CRI(E) HQQE HQQV HQBV HQQE HQQE HQQE HQQE HQQV HQQV HQQE HQQV HQQE HQQV HQQV HQQV HQQV HQQV HQBV HQQE HQQE HQQE HQQE HQQV HQQV HQQE HQQV HQQE
CRN(E) HQQE HQQE HQQV HQQE HQQE HQQE HQQE HQQE HQQE HQQE HQQE HQQE HQQV HQQE HQQE HQQE HQQE HQQV HQQE -
66
Accessories
Counter flanges for CRI(E) and CRN(E)
Counter flanges for CRN(E) pumps are made of stainless steel to EN 1.4401 (AISI 316). A counter flange set consists of one counter flange, one gasket, bolts and nuts.
Counter flange
19
Pump type
Description
Rated pressure
Pipework connection Rp 1
16 bar, EN 1092-2
68 85 115
19
25 bar, EN 1092-2
25 mm, nominal
405285
16 bar, EN 1092-2
Rp 1
91200657
78 100 140
25 bar, EN 1092-2
32 mm, nominal
415305
19
Threaded
16 bar, EN 1092-2
Rp 1
91201023
88 110 150
21
115
18.5
Threaded
16 bar, EN 1092-2
Rp 2
96509570
89 110 150
19
CRI(E) 10 CRN(E) 10
TM03 0401 3705
For welding
25 bar, EN 1092-2
40 mm, nominal
91201025
88 110 150
21
115
18.5
For welding
50 mm, nominal
96509571
89 110 150
67
Accessories
Counter flange
19
Pump type
Description
Rated pressure
Pipework connection
Product number
Threaded
16 bar, EN 1092-2
Rp 2
91201026
Threaded
Rp 2
96509575
18.5
127
Rp 2
96509579
19
For welding
40 bar, EN 1092-2
50 mm, nominal
91201028
127
18.5
For welding
65 mm, nominal
96509573
Threaded
19 19
16 bar 16 bar, special flange 16 bar 40 bar 16 bar, special flange 25 bar, special flange 16 bar 16 bar 40 bar 16 bar 16 bar 40 bar
Rp 2 Rp 3 65 mm, nominal 65 mm, nominal 80 mm, nominal 80 mm, nominal Rp 3 80 mm, nominal 80 mm, nominal Rp 4 100 mm, nominal 100 mm, nominal
349910 349911 349906 349908 349907 349909 350543 350544 350545 369904 369903 369906
121 145
121 145
16 bar
25 bar/40 bar
19
CRN(E) 45
CRN(E) 64 CRN(E) 90
16 bar
26
40 bar
For welding
40 bar, EN 1092-2
26
For welding
40 bar, EN 1092-2
Flange with 20 mm higher collar. With this collar, the installation dimensions of a CR 20 will be identical to those of a CR 32. If a CR 32 is replaced with a CR 20, the base must be raised by 15 mm.
68
Accessories
PJE couplings for CRN(E)
Materials in contact with the pumped liquid are made of stainless steel to EN 1.4401 (AISI 316) and rubber. A PJE coupling set consists of two coupling halves (Victaulic, type 77), one gasket, one pipe stud (for welding or threaded), bolts and nuts.
Coupling Pump type Pipe stub PN A B Pipework Rubber connection parts EPDM
TM00 3808 1094
Number of Product coupling number sets needed 2 2 2 2 2 2 2 2 419911 419905 419912 419904 339911 339918 339910 339917
80 bar
50
320
R 1 FKM EPDM
50
280
DN 32 FKM EPDM
70 bar
80
377
R2 FKM EPDM
80
371
DN 50 FKM
Klingersil
96449746
A B
Klingersil
96449747
96449743
A B
96449744
EPDM CRI(E) CRN(E) 1, 3 5 DIN (stainless steel) DN 25 DN 32 16 75 250 FKM EPDM FKM EPDM 208 1" NPT 25 1" NPT 28.5 Clamp, pipe stub for welding 37.2 50 FKM EPDM FKM EPDM FKM EPDM FKM EPDM FKM
96449745
2 2 2 2 2 2 2 2 2 2 2 2 2
96449900 405280 405281 415296 415297 405291 405292 415311 415312 405282 405283 415300 415301
Rp 1 Rp 1
A B
CRI(E) CRN(E) 1, 3, 5
TM02 7371 3303
69
Accessories
Base connection
Pump type
Connection
Pipework connection
PN
Rubber parts
Product number
Rp 1
Klingersil
96498776
A B
CRI(E) 10 CRN(E) 10
Rp 1
16
80
260
Klingersil
96498728
Rp 2
Klingersil
96498835
96500275
A B
96500276
EPDM FKM EPDM FKM 16 80 316 EPDM FKM DN 50 EPDM FKM EPDM Rp 1 FKM 259
2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2
96498840 96500119 96500263 96500264 96500265 96500266 96500267 96500269 425238 425239 335241 335242 96508600 96508601 425242 425243 335251 335252
CRI(E) 10 CRN(E) 10
A B
TM02 7375 3303
48.3 (DN 40) Clamp, pipe stub for welding 60.3 (DN 50)
70
Accessories
Pipework connection
Various sets of counter flanges and couplings are available for pipework connection.
Pump type
Description Threaded
Rated pressure 16 bar, EN 1092-2 16 bar, special flange 16 bar, EN 1092-2 40 bar, DIN 2635 16 bar, special flange 16 bar 16 bar 40 bar 16 bar, EN 1092-2 16 bar, EN 1092-2 25 bar, EN 1092-2
Pipework connection Rp 2 Rp 3 65 mm, nominal 65 mm, nominal 80 mm, nominal Rp 3 80 mm, nominal 80 mm, nominal Rp 4 100 mm, nominal 100 mm, nominal
Product number 349902 349901 349904 349905 349903 350540 350541 350542 369901 369902 369905
19
Threaded
TM03 2116 3705
CR(E) 32
Rp 2 / 16 bar
19
Rp 3 / 16 bar
40 bar
CR(E) 45
CR(E) 64 CR(E) 90
16 bar
26
25 bar
For welding
40 bar, EN 1092-2
96750475
26
CR 120 CR 150
TM03 8891 2707
For welding
40 bar, EN 1092-2
96750476
Flange with 20 mm higher collar. With this collar, the installation dimensions of a CR 20 will be identical to those of a CR 32. If a CR 32 is replaced with a CR 20, the base must be raised by 15 mm.
71
Accessories
Potentiometer for CRE, CRIE, CRNE
The potentiometer is for setpoint setting and start/stop of the CRE, CRIE, CRNE pump.
Product External potentiometer with cabinet for wall mounting Product number 625468 Product R100
200-240
96556429
116 mm
80-130
96556430
90 mm
96443676
72
Accessories
Sensors for CRE, CRIE, CRNE
Accessory Flowmeter Flowmeter Flowmeter Flowmeter Temperature sensor Temperature sensor Temperature sensor Temperature sensor Type SITRANS FM MAGFLO MAG 5100 W SITRANS FM MAGFLO MAG 5100 W SITRANS FM MAGFLO MAG 5100 W SITRANS FM MAGFLO MAG 5100 W TTA (0) 25 TTA (-25) 25 TTA (50) 100 TTA (0) 150 Protecting tube 9 x 50 mm Protecting tube 9 x 100 mm Cutting ring bush Temperature sensor, ambient temperature Differential temperature sensor Differential temperature sensor Note: All sensors have 4-20 mA signal output. Danfoss pressure sensor kits for CRE, CRIE, CRNE 1, 3, 5, 10, 15, 20, 32, 45, 64 and 90 The kit comprises: Danfoss pressure transmitter, type MBS 3000, with 2 m screened cable Connection: G A (DIN 16288 - B6kt) 5 cable clips (black) Instruction manual PT (00 40 02 12) Pressure range 0-4 bar 0-6 bar 0-10 bar 0-16 bar 0-25 bar DPI differential pressure sensor kit The kit comprises: 1 sensor incl. 0.9 m screened cable (7/16" connections) 1 original DPI bracket (for wall mounting) 1 Grundfos bracket (for mounting on motor) 2 M4 screws for mounting of sensor on bracket 1 M6 screw (self-cutting) for mounting on MGE 90/100 1 M8 screw (self-cutting) for mounting on MGE 112/132 3 capillary tubes (short/long) 2 fittings (1/4" - 7/16") 5 cable clips (black) Installation and operating instructions (00480675) Service kit instructions. Pressure range 0-0.6 bar 0-1.0 bar 0-1.6 bar 0-2.5 bar 0-4.0 bar 0-6.0 bar 0-10 bar 40 C to +85 C WR 52 ETSD ETSD Supplier Siemens Siemens Siemens Siemens Carlo Gavazzi Carlo Gavazzi Carlo Gavazzi Carlo Gavazzi Carlo Gavazzi Carlo Gavazzi Carlo Gavazzi tmg (DK: Plesner) Honsberg Honsberg 50 C to +50 C 0 C to +20 C 0 C to +50 C Measuring range 1-5 (DN 25) 3-10 m3 (DN 40) 6-30 m (DN 65)
3
Product number ID8285 ID8286 ID8287 ID8288 96432591 96430194 96432592 96430195 96430201 96430202 96430203 ID8295 96409362 96409363
m3
Temperature range
73
Variants
Lists of variants - on request
Although the Grundfos CR(E), CRI(E), CRN(E) product range offers a number of pumps for different applications, customers require specific pump solutions to satisfy their needs. See following documents: Grundfos CR "Custom-built pumps" catalogue Grundfos "CR, CRN high pressure" data booklet. Below please find the range of options available for customizing the CR(E) pumps to meet the customers demands. Contact Grundfos for further information or for requests other than the ones mentioned below. Motors
Variant ATEX motor Motor with anticondensation heating unit Description For operation in hazardous atmospheres, explosion-proof or dust-ignition-proof motors may be required. For operation in humid environments motors with built-in anti-condensation heating unit may be required. High-pressure pump up to 47 bar
Pumps
Variant Horizontally mounted pump Description For safety or height reasons, certain applications, for instance on ships, require the pump to be mounted in the horizontal position. For easy installation the pump is equipped with brackets that support motor and pump. Exposed to temperatures down to 40 C, coolant pumps may require neck-rings with a different diameter in order to prevent impeller drag. For high-pressure applications, Grundfos offers a unique pump capable of generating up to 47 bar. The pump is equipped with a high-speed motor, type MGE. The direction of rotation is the opposite of that of standard pumps, and the chamber stack is turned upside-down, as a result of which the pumped liquid flows in the opposite direction. For high-pressure applications, Grundfos offers a unique double pump system capable of generating a pressure of up to 47 bar pressure.
Low-temperature pump
Recommended for boiler-feed applications Low-NPSH pump where cavitation may occur due to poor inlet (improved suction) conditions. The bearing flange is suitable for applications where the inlet pressure is higher than the Pump with bearing maximum pressure recommended. The bearing flange increases the life of motor flange bearings. (Recommended for standard motors.) Belt-driven pump Pump for pharmaceutical and biotechnological applications Belt-driven pumps designed to operate in places with limited space or where no electrical power is available. CRN(E) pumps designed for applications requiring the sterilization and CIP capability of pipes, valves and pumps. (CIP = Cleaning-InPlace.)
Grundfos offers motors with built-in bimetallic Motor with thermal thermal switches or temperature-controlled protection PTC sensors (thermistors) incorporated in the motor windings. Oversize motor 4-pole motor Ambient temperatures above 40C or installation at altitudes of more than 1000 metres above sea level require the use of an oversize motor (i.e. derating). Grundfos offers 4-pole standard motors.
Shaft seals
Variant Shaft seal with FFKM O-ring material Seal with flush, quench seal Description Shaft seals with FFKM or FXM O-ring material are recommended for applications where the pumped liquid may damage the standard Oring material. Recommended for applications involving crystallizing, hardening or sticky liquids. Recommended for applications involving extremely high temperatures. No conventional mechanical shaft seal can withstand liquid temperatures of up to 180C for any length of time. For such applications, Grundfos unique aircooled shaft seal system is recommended. In order to ensure a low liquid temperature around the standard shaft seal, the pump is fitted with a special air-cooled shaft seal chamber. No separate cooling is required. Recommended for applications involving poisonous or explosive liquids. Protects the surrounding environment and the people working in the vicinity of the pump. Consists of two seals mounted in a "back-toback" arrangement inside a separate pressure seal chamber. As the pressure in the chamber is higher than the pump pressure, leakage is prevented. A dosing pump or a special pressure-intensifier generates the seal chamber pressure. Magnetically driven pumps for industrial applications. Key applications are industrial processes involving the handling of aggressive, environmental, dangerous or volatile liquids, e.g. organic compounds, solvents, etc.
Pipe connections
CR MAGdrive
74
WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: Catalogue Literature Service Sizing Replacement CAD drawings.
Catalogue This section is based on fields of application and pump types, and contains technical data curves (QH, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc.
Literature In this section you can access all the latest documents of a given pump, such as data booklets installation and operating instructions service documentation, such as Service kit catalogue and Service kit instructions quick guides product brochures.
Service This section contains an easy-to-use interactive service catalogue. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts.
75
This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc.
Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency.
CAD drawings In this section it is possible to download 2-dimensional (2D) and 3dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings: .dxf, wireframe drawings .dwg, wireframe drawings. 3-dimensional drawings: .dwg, wireframe drawings (without surfaces) .stp, solid drawings (with surfaces) .eprt, E-drawings.
WinCAPS
WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year.
Fig. 28 WinCAPS CD-ROM
To request a free copy of the WinCAPS CD-ROM, please visit the Grundfos UK web site at www.grundfos.co.uk.
76
77
78
79
Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence
Tel: 01506 461666, Fax:01506 461555, Email: uklivquotes@grundfos.com Tel: 08707 503888, Fax: 01942 605970, Email: ukcbsleigh@grundfos.com
Original Equipment Manufacturer Leighton Buzzard Office: Tel: 01525 775444, Fax: 01525 853981, Email: uk-sales@grundfos.com Spares Team Leigh Office: Service Mobile Service: Service Workshop (Leigh):
Tel: 08450 508100, Fax: 01942 602830 Tel: 01942 263627, Fax: 01942 603462
Grundfos Control Solutions Telephone: 01525 850000 Fax: 01753 832335 email:uk-gcs@grundfos.com
V7144411 0208
Repl. V7144411 0106
GB
Subject to alterations.
www.grundfos.co.uk