Made in Italy
TPR6 PLUS
MV/LV
TPS
Low Voltage
TPR6
CAB_ed. 1101-In
Index
Introduction Standards and Quality Substation design Internal arrangement and operation type Enclosure design Decoration and finishingStandard conformity Information with enquires and orders Power transformer dimension Internal arc proof Walk-in type substation -Internal arc proof Non Walk-in type substation -Internal arc proof Type test list Routine tests WALK-IN TYPE 244 Series Overall dimensions CAV2416W0001 - 244x164x246 CAV2416W0002 - 244x164x266 CAV2420W0001 - 244x200x246 CAV2420W0002 - 244x200x266 CAV2425W0001 - 244x250x246 CAV2425W0002 - 244x250x266 CAV2430W0001 - 244x300x246 CAV2430W0002 - 244x300x266 CAV2432W0001 - 244x324x260 CAV2435W0001 - 244x330x246 CAV2435W0002 - 244x330x266 CAV2440W0001 - 244x400x246 CAV2440W0002 - 244x400x266 CAV2440W0003 - 244x400x260 CAV2445W0001 - 244x450x246 CAV2445W0002 - 244x450x266 CAV2450W0001 - 244x500x246 CAV2450W0002 - 244x500x266 CAV2455W0001 - 244/550x246 CAV2455W0002 - 244x550x266 CAV2460W0001 - 244x600x246 CAV2460W0002 - 244x600x266 CAV2465w0001 - 244x650x246 CAV2465W0002 - 244x650x266 CAV2470W0001 - 244x700x246 CAV2470W0002 - 244x700x266 CAV2475W0001 - 244x750x246 CAV2475W0002 - 244x750x266 6 7 8 9 10-11 12-13 14 15 16 17 18 19 19 20 20 21 21 22 22 23 24 24 25 25 26 27 27 28 28 29 29 30 30 31 31 32 32 33 33 Substation accessories Substation equipment Power transformers 48 - 49 50 51 Equipment installation Metal enclosure Prefabbricated metal substation Containerized transformer substation 40-41 42 42-43 44 - 47 4 5 NON WALK-IN TYPE 210 Series Overall dimensions CAV2124O0001 - 210x244x170 CAV2133O0001 - 210x330x170 CAV2133O0002 - 210x300x170 CAV2140O0001 - 210x400x170 34-35 36 37 38 39
CAB_ed. 1101-In
Power Plant
INTRODUCTION SEL supplies complete prefabricated MV/LV CAB substations made in concrete or in metal. Substations include MV equipment and they can be supplied with transformer and LV equipment. The operation of the substations can be done from inside (walk-in type) or from outside (non walk-in type). The general features of CAB substations are: Maximum safety and reliability Housing made of time resistant materials Personalized and flexible design Quick realization and easy installation
Distribution network
Sports villages
Infrastructure
Transport
Substations can be monobloc or panel type and in this way they can meet all the requirements of a versatile plant. They can be installed in the industrial area, generation and cogeneration plants, city distribution network etc. STANDARDS The substations are in compliance with IEC 62271-202 standard. QUALITY SYSTEM Our production is made in accordance with quality control system EN ISO 9001:2008 certificated by TUV.
Substation design
INTERNAL ARRANGEMENT AND OPERATION TYPE
General CAB prefabricated substations are designed so that normal service, inspection and maintenance can be carried out safely. Additionally, the substations are designed and constructed in such a way that the risk of unauthorized access is minimized. Attention is paid to hinges, doors, louvers, locking mechanism, etc. Design criteria The definition of substation depends on several criteria; main of them are : Rated electrical characteristics Rated mechanical characteristics Operation from inside or outside Internal arrangement of HV and LV switchgear and control gear, power transformer, cables connection, etc. Type of material enclosure Prefabricated foundation or foundation made on site.
LONGITUDINAL
DIAGONAL
CAB_ed. 1101-In
WALK-IN TYPE
FRONTAL
Substation design
ENCLOSURE DESIGN
PREFABRICATED FOUNDATION
SF6 Insulation
MV CUBICLE TYPE
GAS-INSULATED SWITCHGEAR
AIR-INSULATED SWITCHGEAR
LV DEVICE
CIRCUIT BREAKER FUSE DISCONNECTOR 7
DRY
With oil retention tank
Other main criteria are : HV switchgear and control gear series: SF6-insulated (very compact) or air-insulated (easily extensible) Power transformer type and load factor LV switchgear and control gear: protection device type (fuses or automatic circuit-breaker). LV switchgear and control gear type assembly
CAB_ed. 1101-In
Substation design
Other main criteria are :
HV and LV cables connection Auxiliary circuits Remote control Internal lighting and service plant Earthing circuits Ventilation openings Internal arc capability: accessibility A, B or AB. Type of decoration, painting colour, coating surface treatment Roof shape
Many customized decorations and finishing are available on request to personalize the substation. CAB substations can also meet every painting and coating surface treatment requested. Particular kind of roof, louvers, doors, grid or other specific solutions can be studied together with the customer.
STANDARD CONFORMITY
CAB prefabricated substations meet all the main characteristics indicated in IEC 62271-202 standard. Roof load 2500 N/m External mechanical impact 20J Degree of protection IP23 Class of the enclosure up to 5K Temperature rise tested Internal Arc Capability
CAB_ed. 1101-In
b) Service conditions
Minimum and maximum ambient temperature Any condition deviating from the normal service conditions such as altitudes higher than 1000m, winddriven sand or snow, unusual exposure to vapour, moisture, fumes, explosive gases, excessive dust or salt, risk of earth tremors, or other.
CAB_ed. 1101-In
ta1 is the ambient air temperature of the test room tt1 is the transformer temperatures ta1 is the temperature rise of the transformer outside an enclosure ta2 is the ambient air temperature of the test room tt2 is the transformer temperatures ta2 is the temperature rise of the transformer inside an enclosure
10
CAB_ed. 1101-In
CAB_ed. 1101-In
11
IAC-B Criteria: Criterion no. 1: Correctly secured doors and covers of the substation do not open. Criterion no. 2: No fragmentation of the enclosure occurs within the time specified for the test. Criterion no. 3: Arcing does not cause holes in the roof and in the accessible sides up to height of 2m. Criterion no. 4: Indicators do not ignite due to the effect of hot gases. Criterion no. 5: The enclosure remains connected to its earthing point.
12
CAB_ed. 1101-In
EXHAUST GAS FLOW The exhaust gases flow in outside direction of the substation, through antivermin grid chamber or flap window opened by overpressure. The figure below shows the typical exhaust gas flow verified during the internal arc test.
PRESSURE RELIEF FLAP WINDOW This accessory guarantees the suitable thermal insulation with the external ambient. For a better thermal insulation it is possible to fill the pressure relief duct collar with glass wool.
The relevant arrangement is the canalization to direct the exhaust gases of the internal arc outside. The figure beside shows exhaust gas channel and the way how gases flow outside. The above photo is the valve which brings out the gases, this chamber prevents the incoming of any foreign materials, vermin or animals.
CAB_ed. 1101-In
13
EXHAUST GAS FLOW In case of an internal fault in the MV Switchgear the exhaust gases are canalized to the bottom so that they loose their energy before going out through the grid doors.
The figure shows the typical exhaust gas course verified during the internal arc test.
14
CAB_ed. 1101-In
EXHAUST GAS CANALIZATION In case of an internal fault in the MV Switchgear the exhaust gases are canalized to the bottom so that they loose their energy before going out through the grid doors.
The figure shows the typical exhaust gas flow verified during the internal arc test.
CAB_ed. 1101-In
15
Type tests
Type test list in accordance with IEC62271-202
Test
Power Frequency withstand voltage test Temperature rise test Mechanical impact test Short time and peak withstand current on earthing circuits Internal arc test Fire behaviour Electromagnetic compatibility tests
Notes
Insulation voltage 24kV Environmental class 10K 20 J 16 kA 1s IAC/AB - 16kA - 1s Up to R120 On secondary systems
16
CAB_ed. 1101-In
Routine tests
Routine tests
Can be carried out in SEL test room in accordance with IEC62271-202
All the routine tests required by standard IEC 62271-202 can be carried out in SEL test room: dielectric tests on HV and on LV apparatus, tests on auxiliary and control circuits, functional tests, verification of the correct wiring. In addition also the following tests can be carried out: temperature rise test for a wide range of rated power, lightning impulse voltage tests on HV and LV devices, partial discharge measurements on HV switchgear and controlgear.
These tests can be carried out in SEL test room: Item Test description
1 2 3 4 5 Power frequency voltage withstand test Lightning impulse voltage test Temperature rise test Functional test Verification of correct wiring
Note
Up to 36kV rated insulation voltage Up to 36kV rated insulation voltage Up to 630kVA rated power
Prefabricated substation equipped with MV switchboard, MV/LV transformer and LV switchboard during temperature rise test carried out in SEL Test Room and a relative test report.
CAB_ed. 1101-In
17
Walk-in type
L 244
OVERALL DIMENSIONS Code CAV2416W0001 CAV2420W0001 CAV2425W0001 CAV2430W0001 L [cm] 164 200 250 300 H[cm] 246 246 246 246 Code CAV2416W0002 CAV2420W0002 CAV2425W0002 CAV2430W0002 CAV2432W0002 CAV2435W0001 CAV2440W0001 350 400 246 246 CAV2435W0002 CAV2440W0002 CAV2440W0003 CAV2445W0001 CAV2450W0001 CAV2455W0001 CAV2460W0001 CAV2465W0001 CAV2470W0001 CAV2475W0001 450 500 550 600 650 700 750 246 246 246 246 246 246 246 CAV2445W0002 CAV2450W0002 CAV2455W0002 CAV2460W0002 CAV2465W0002 CAV2470W0002 CAV2475W0002 L [cm] 164 200 250 300 324 350 400 400 450 500 550 600 650 700 750 H[cm] 266 266 266 266 260 266 266 266 266 266 266 266 266 266 266
18
CAB_ed. 1101-In
Walk-in type
CAV2416W0001PREFABRICATED SUBSTATION 244 X 164 X 246 cm.
7
PROSPECTUS A PROSPECTUS D
PROSPECTUS B
1 3 8 8 3
PROSPECTUS C
2 5
3 8 9
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
CAB_ed. 1101-In
19
Walk-in type
CAV2420W0001
PREFABRICATED SUBSTATION 244 X 200 X 246 cm.
PROSPECTUS A PROSPECTUS D PROSPECTUS B
7 2
7 2
1 3 8 8 3
PROSPECTUS C
2 4
3 5 8
1* Door dim. Nominal 1200x2150mm 2* Louver dim. Nom. 1200x500mm 3* Louver dim. Nom. 1200x500mm 4 MV Switchgear 5 MV/LV Transformer 6 7 Lifting hook 8 Foundation
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
20
CAB_ed. 1101-In
Walk-in type
CAV2425W0001
PREFABRICATED SUBSTATION 244 X 250 X 246 cm.
PROSPECTUS A
PROSPECTUS D
PROSPECTUS B
1 3 8 8
PROSPECTUS C
2 4
3 6 8
1* Door dim. Nominal 1200x2150mm 2* Louver dim. Nom. 1200x500mm 3* Louver dim. Nom. 1200x500mm 4 5 6 7 8 MV Switchgear MV/LV Transformer LV Switchgear Lifting hook Foundation
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
CAB_ed. 1101-In
21
Walk-in type
CAV2430W0001
PREFABRICATED SUBSTATION 244 X 300 X 246 cm.
PROSPECTUS A
7 7
PROSPECTUS D
7 7
PROSPECTUS B
1 3 8
PROSPECTUS C
2 4 5 3 6 8
1* Door dim. Nominal 1200x2150mm 2* Louver dim. Nom. 1200x500mm 3* Louver dim. Nom. 1200x500mm 4 MV Switchgear 5 MV/LV Transformer 6 LV Switchgear 7 Lifting hook 8 Foundation
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
22
CAB_ed. 1101-In
Walk-in type
CAV2432W0001
PREFABRICATED SUBSTATION 244 X 324 X 260 cm. 7
PROSPECTUS A
7
PROSPECTUS B
7
PROSPECTUS C
7
PROSPECTUS D
2 8 8
1* Door dim. Nominal 1200x2150mm 2* Louver dim. Nom. 1200x500mm 3* Louver dim. Nom. 1200x500mm 4 5 6 7 8 9 MV Switchgear MV/LV Transfor LV Switchgear Lifting hook Foundation Floor hole for MV cable
5 9 4
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
CAB_ed. 1101-In
23
Walk-in type
CAV2435W0001
PREFABRICATED SUBSTATION 244 X 350 X 246 cm.
PROSPECTUS A
PROSPECTUS D
PROSPECTUS B
1 8
1 8 8
PROSPECTUS C
2 5 4
8 Foundation
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
24
CAB_ed. 1101-In
Walk-in type
CAV2440W0001
PREFABRICATED SUBSTATION 244 X 400 X 246 cm. 7
PROSPECTUS A
PROSPECTUS D
PROSPECTUS B
1 3 8 8 8
PROSPECTUS C
2 4 3 8 5 6
8 Foundation
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
CAB_ed. 1101-In
25
Walk-in type
CAV2440W0003
PREFABRICATED SUBSTATION 244 X 400 X 260 cm. 7
PROSPECTUS A PROSPECTUS B
8 8
7
PROSPECTUS C
7
PROSPECTUS D
2 8 8
1* Door dim. Nominal 1200x2150mm 2* Louver dim. Nom. 1200x500mm 3* Louver dim. Nom. 1200x500mm 4 5 6 MV Switchgear MV/LV Transformer LV Switchgear
6 4
5 9
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
26
CAB_ed. 1101-In
Walk-in type
CAV2445W0001
PREFABRICATED SUBSTATION 244 X 450 X 246 cm. 7 2 7
PROSPECTUS A
PROSPECTUS D
PROSPECTUS B
3 8
1* 2* 3* 4 5 6 7 8
Door dim. Nominal 1200x2150mm Louver dim. Nom. 1200x500mm Louver dim. Nom. 1200x500mm MV Switchgear MV/LV Transformer LV Switchgear Lifting hook Foundation
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
4 5
6 5
CAB_ed. 1101-In
27
Walk-in type
CAV2445W0001
PREFABRICATED SUBSTATION 244 X 500 X 246 cm. 7 2 7
PROSPECTUS A
PROSPECTUS D
PROSPECTUS B
3 8
1* 2* 3* 4 5 6 7 8 9 10
Door dim. Nominal 1200x2150mm Louver dim. Nom. 1200x500mm Louver dim. Nom. 1200x500mm MV Switchgear MV/LV Transformer LV Switchgear Lifting hook Foundation Door dim. Nominal 600x2150mm Door dim. Nominal 900x2150mm
4 5
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
6 5
28
CAB_ed. 1101-In
Walk-in type
CAV2455W0001
PPREFABRICATED SUBSTATION 244 X 550 X 246 cm. 7 7 2 3 9 9 3
PROSPECTUS A
PROSPECTUS D
PROSPECTUS B
1* 2* 3* 4 5 6 7 8 9 10
Door dim. Nominal 1200x2150mm Louver dim. Nom. 1200x500mm Louver dim. Nom. 1200x500mm MV Switchgear MV measuring LV Switchgear Lifting hook Foundation Door dim. Nominal 600x2150mm Door dim. Nominal 900x2150mm
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
CAB_ed. 1101-In
29
Walk-in type
CAV2460W0001
PREFABRICATED SUBSTATION 244 X 600 X 246 cm. 7 7
1 9
PROSPECTUS A
PROSPECTUS D
PROSPECTUS B
7
PROSPECTUS C
1* 2* 3* 4 5 6 7 8 9 10
Door dim. Nominal 1200x2150mm Louver dim. Nom. 1200x500mm Louver dim. Nom. 1200x500mm MV Switchgear MV Measuring
Lifting hook Foundation Door dim. Nominal 600x2150mm Door dim.Nominal 900x2150mm
5 4 4
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
30
CAB_ed. 1101-In
Walk-in type
CAV2465W0001
PREFABRICATED SUBSTATION 244 X 650 X 246 cm. 7 7
8
PROSPECTUS A
8
PROSPECTUS D
8
PROSPECTUS B
3 8
1* 2* 3* 4 5 6 7 8 9 10
Door dim. Nominal 1200x2150mm Louver dim. Nom. 1200x500mm Louver dim. Nom. 1200x500mm MV Switchgear MV/LV Transformer LV Switchgear Lifting hook Foundation Door dim. Nominal 600x2150mm MV Measuring
10 4 5 4 6
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
CAB_ed. 1101-In
31
Walk-in type
CAV2470W0001
PREFABRICATED SUBSTATION 244 X 700 X 246 cm. 7 7
3 8 8
PROSPECTUS D
8
PROSPECTUS B
PROSPECTUS A
8
PROSPECTUS C 1* 2* 3* 4 5 6 7 8 9 10 Door dim. Nominal 1200x2150mm Louver dim. Nom. 1200x500mm Louver dim. Nom. 1200x500mm MV Switchgear MV/LV Transformer LV Switchgear Lifting hook Foundation Door dim. Nominal 600x2150mm MV Measuring
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
5 4 10 6
32
CAB_ed. 1101-In
Walk-in type
CAV2475W0001
PREFABRICATED SUBSTATION 244 X 750 X 246 cm. 7 7
1 9
10
3 8 8 8
PROSPECTUS A
PROSPECTUS D
PROSPECTUS B
8
PROSPECTUS C
1* 2* 3* 4 5 6 7 8 9 10 11
Door dim. Nominal 1200x2150mm Louver dim. Nom. 1200x500mm Louver dim. Nom. 1200x500mm MV Switchgear MV/LV Transformer LV Switchgear Lifting hook Foundation Door dim.Nominal 600x2150mm Door dim.Nominal 900x2150mm MV Measuring
11 4
* - It is possible to install doors and louvers made in reinforced plastic with incorporated fiberglass, anodized or painted aluminium, galvanized or painted steel sheets.
CAB_ed. 1101-In
33
No Walk-in type
L P
OVERALL DIMENSIONS Code CAV2124O0001 CAV2133O0001 CAV2133O0002 CAV2140O0001 L[mm] 2440 3300 3300 4000 P[mm] 2100 2100 2100 2100 H[mm] (*) 1700 1700 1700 1700
34
CAB_ed. 1101-In
750
No Walk-in type
L 750 850
CAB_ed. 1101-In
35
No Walk-in type
CAV2124O0001
PREFABRICATED SUBSTATION 210X244X170 cm For one transformer from 100 to 630KVA
PROSPECTUS B+D PROSPECTUS A
7
PROSPECTUS C SECTION B - D
5 7
Double opening louver Opening louver Ground level MV Switchgear MV/LV Transformer LV Switchgear
2 3 4
5 6
7 8
36
CAB_ed. 1101-In
No Walk-in type
CAV2133O0001
PREFABRICATED SUBSTATION 210X330X170 cm For one transformer from 630 to 1250KVA
PROSPECTUS A PROSPECTUS B
3 8
PROSPECTUS C
PROSPECTUS D
5 6
6
7 8 Lifting hook Foundation
CAB_ed. 1101-In
37
No Walk-in type
CAV2133O0002
PREFABRICATED SUBSTATION 210X300X170 cm For two transformers from 100 to 630KVA
PROSPECTUS A PROSPECTUS B
1 1 3
7
PROSPECTUS C PROSPECTUS D
1 1 3
7
1 2 3 4 5 Double opening louver Opening louver Ground level MV Switchgear MV/LV Transformer LV Switchgear Lifting hook Foundation
6 7
38
CAB_ed. 1101-In
No Walk-in type
CAV2140O0001
PREFABRICATED SUBSTATION 210X400X170 cm For two transformers 630800 KVA
PROSPECTUS A PROSPECTUS B
2 3
PROSPECTUS C
PROSPECTUS D
2 1 3
7
1 2 3 4 5 Double opening louver Opening louver Ground level MV Switchgear MV/LV Transformer LV Switchgear Lifting hook Foundation
6 7 8
CAB_ed. 1101-In
39
Equipment installation
Equipment installation
Some equipment can be installed inside the non walk-in type substation from the upper side. The roof can be handled by means of the lifting hooks. Fixing of the roof is made by means of the brackets situated in the corners.
40
CAB_ed. 1101-In
Equipment installation
Power transformer installation
Power Transformer installation facilities for non walk-in type substation. The photos below show the main steps of power transformer installation.
CAB_ed. 1101-In
41
42
CAB_ed. 1101-In
Metal structure prefabricated substation It is possible to choose the customized characteristics in the same way with the concrete substation. SEL can propose walk-in or non walk-in type prefabricated substation, with or without prefabricated foundation built in concrete or in metal structure. The photos show typical installation in the wind farm.
CAB_ed. 1101-In
43
MV/LV Outdoor Containerized Substation: a good solution against concreted transformer Substations - Manufactured tor outdoor and yard Installations; - Its a free standing containerized unit, easily movable, turnke y installed - Provided with MV switchgear, transformer and LV switcthgear and eventually APFC.- Equipped with safety equipment; - Designed to suit Customer requirements: - It doesn't need building permits
Transformer substations are designed to be in compliance with European and international Standards (CEI/IEC).
Technical solutions are in compliance with necessary requirements like: - Personnel and operations safety. in order to protect from contact with live parts. - Fire safety - Effective electrical and thermic insulation - Service continuity
44
CAB_ed. 1101-In
-20 50
500 140 220 AF5 54
The containerized transformer substation is composed by one transformer compartment and one MV and LV switchgear compartment. The cabin is made with a stand alone structure made of normalized protected steel UNP electro - welded profiles and external panel realized with folded ribbed sheet wile the floor is made of an antiskid metal sheet. External stand alone layout profiles are drawn tube and theyve at each edge twist lock corner as for ISO standards, useful for handling and lifting. The cabin is designed to have best service condition, security and lasting performance of installed equipment, and it have: The roof and walls made with thermo-insulated material that do not spread fire. Access door are made with one or two swings where one of them is with panic bar. Access to transformer and switchgear compartment on the heads of the cabinet through safety key lock doors with limit switch unlock. Natural ventilation of switchgears compartment made with anti-insect slits while transformer compartment has forced ventilation with a remote control thermostat installed in switchgear compartment. The electrical power and auxiliary equipments are interconnected and tested in our factory, ready to be used.
CAB_ed. 1101-In
45
Example
Wall of segregation MV Switchgear
MV/LV Transformer
LV Switchgear
46
CAB_ed. 1101-In
Aeration and climatization Container compartment are designed to ease natural air exchange, and it happens with air aspiration and expulsion through slits protected by a sand trap grid. Fun or air conditioner are provided when natural air expulsion isnt sufficient inside container. In particular environmental conditions, extremely hot or cold, container is provided with cooling or heating conditioning system that ensure equipment functioning.
Handling Containerized substation is suitable for transport, tanks to CCS (container safety convention) for ISO standard dimensions - 10 - 20 - 30 - 40. Handling and lifting is possible with edges blocks of same dimensions and design located in the corners of the container. This edges blocks allow the floor fixing, handling and lifting. Is possible to have cabinet designed with runners for Fork Lift lifting.
CAB_ed. 1101-In
47
Substation Accessories
Warning labels - Insulating gloves Emergency lamp - Fire extinguisher Earthing circuit
48
CAB_ed. 1101-In
Substation Accessories
Fiberglass
Aluminium
Doors
Earth bonding point
Ventilation
CAB_ed. 1101-In
49
Equipment
Substation equipment
Prefabricated concrete enclosure Reinforced concrete monobloc enclosure Reinforced concrete panel type enclosure
MV switchgear and control gear TPS air insulated or TPR6 gas insulated Internal arc proof 16kA 1s Insulated voltage up to 36kV Rated current 630A Short circuit withstand current 20kA
LV switchgear and control gear LV-rack Rated insulation voltage 690V Degree of protection IP3X Rated busbar current up to 1500A Rated short circuit current up to 25kA
MV/LV cable connection MV cable Type RG7H1R 12/20kV LV cable type FG7OR 0,6/1kV MV suitable termination cable MV cable Plug-in termination (on request)
50
CAB_ed. 1101-In
Equipment
Power transformer
Dry-Type Power Transformer
Rated Insulation Voltage [kV] Short Circuit voltage (%) Rated Height Depth Lenght Weig Powe [mm] [mm] [mm] ht r Kg. [kVA ] 100 160 250 315 400 500 6 24 630 800 1000 1250 1600 2000 2500 7 3150 1150 1200 1250 1270 1380 1460 1580 1660 1860 2030 2120 2300 2370 2450 700 700 700 800 800 800 800 800 1000 1000 1000 1300 1300 1300 1100 1120 1260 1330 1350 1370 1440 1470 1560 1660 1770 1890 2020 2230 550 650 1000 1100 1250 1400 1700 2000 2300 2900 3500 4400 5250 6200
Dry-Type Power Transformer Environmental class E2 Climatic class C2 Fire behaviour F1 Standard or low losses Equipped with Pt100 thermoresistences
Oil-insulated Power Transformer Oil tank retention Available also sealed solution Buchholz and thermometer equipped
CAB_ed. 1101-In
51
Our policy is one of continuous development. Accordingly we reserve the right to change the design of our products at any time. Whilst every effort is made to produce up to date information this brochure should only be regarded as a guide and is intended for information purposes only. Its contents do not constitute an offer for sale or advise on the application of any product referred to in it. We cannot be held responsible for any reliance on any decisions taken on its contents without specific advice.
SEL S.p.A.
Via Amendola - 51035 LAMPORECCHIO (PT) - ITALY Tel. +39-0573/80051 Fax: +39-0573/803110 Website: www.sel-electric.com e-mail: info@sel-electric.com