Sunteți pe pagina 1din 8

03/13

CORPAB-022-13_Component Cut Sheets_052013rev00


Reference Tags: 3400-EEVF-19001, 3400-EEVF-19002

LPP-T65 Hose Pump


FLOW WITH MAXIMUM PRESSURE

TECHNICAL DATA SHEET

Technical Data
Maximum flow: 20m3/h Maximum pressure: 10 bar Flow/revolution: 5.4 l Hose bore: 65 mm Lubricant volume: 3 l Weight: ~960 kg Motor power: 3-11 kW

Dimensions (X, Y) vary according to the drive size. Please consult Flowrox Oy for the exact drive sizing to your application.

Page (5) of (12)

CORPAB-022-13_Component Cut Sheets_052013rev00


Reference Tags: 3400-EEVF-19001, 3400-EEVF-19002

FLOWROX PUMP MODEL NUMBERING


Model
LPP-T = Industrial hose pump

Size Drive (DN)


25 32 40 50 65 80 100 (mm) GM = geared motor GU = gear unit BS = bare shaft pump

Pressure Class (PN)


10 = 10 BAR 7.5 = 7.5 BAR (DN80)

Connection
1=2 = flanged DIN PN 10 3 = flanged DIN PN 16 6 = flanged ANSI 150 8 = flanged B.S. TABLE D 9 = other

Body Material
0 = FE

Drive Control
II = Integrated inverter (IP66) I = Inverter (IP20) N = None WC = Control unit

Auxiliaries
T = pressure transmitter with display R = Revolution detector D = Hose leak detector H = Connector hoses K = Connector flange for pressure transmitter F = Forced cooling

Example: Pump LPP-T40, geared motor, 10 bar, flanges DIN PN 10, with integrated inverter, pressure transmitter with display, hose leak detector Type marking: LPP-T40GM 10-2-0-II-TD

FLOWROX PUMP HOSE MODEL NUMBERING


Hose Type Hose Material Pressure Class (PN)
10 = 10 BAR 7.5 = 7.5 BAR (DN80)

Hose Inner Diameter


(mm) 25 32 40 50 65 80 100

LPP-T = LPP-T pump EPDM = Ethylene propylene hose NR = Natural rubber NBR = Nitrile NBRF = Nitrile (FDA)

Example: LPP-T hose, natural rubber, pressure class 10 bar, hose bore diameter 40 mm Type marking: LPP-T40-NR10

Information without engagement. All rights to changes without prior notice reserved.

Flowrox

Page (6) of (12)

P.O. Box 338 FI-53101 Lappeenranta Finland

Tel. +358 (0)201 113 311 Fax +358 (0)201 113 300

info@flowrox.com www.flowrox.com

PARTS LISTING AND EXPLODED VIEW SENTRY MODEL CT4040ND-24


CORPAB-022-13_Component Cut Sheets_052013rev00
Reference Tags: 3400-EEVF-19001, 3400-EEVF-19002

SENTRY MODEL #: MAXIMUM PRESSURE: CAPACITY: WETTED HOUSING: NONWETTED HOUSING: BLADDER: INLET: AIR CONTROL: DESCRIPTION Component Wetted Housing Bladder Nonwetted Housing Gauge Tee Fill Valve Bushing Fastener Assy

CT4040ND-24 275 PSI/18.96 BAR 5 GALLONS/18.93 LITERS CARBON STEEL CARBON STEEL EPDM 3" 150# RAISED FACE FLANGE CHARGEABLE

ITEM 1 2 3 4 5 6 7 8
2/20/2007

PART # 4040-27-24 231-028 4040-24-24 G22 101-46 101-71 1000-42 4020-50

QTY 1 1 1 1 1 1 1 1

Material Carbon Steel EPDM Carbon Steel Stainless Steel / Brass / Bronze Steel Stainless Steel Galvanized Steel Stainless Steel

ITEM

DIMENSIONAL DRAWING

TOLERANCE .25" BLACOH FLUID CONTROL, INC


RIVERSIDE, CA 92507 USA TEL: 800.603.7867 or 951.342.3100 Fax: 951.342.3101 E-mail: sales@blacoh.com web site: www.blacoh.com

Page (7) of (12)

CORPAB-022-13_Component Cut Sheets_052013rev00


Reference Tags: 3400-EEVF-19001, 3400-EEVF-19002

Inductive proximity switches

IGS204
IGB3008BBPKG/M/US Metal thread M18 x 1 Quick disconnect Increased sensing range gold-plated contacts Sensing range 8mm [f] flush mountable

Electrical design Output Operating voltage [V] Current rating [mA] Short-circuit protection Reverse polarity protection overload protection Voltage drop [V] Current consumption [mA] Real sensing range [mm] Operating distance [mm] Switch-point drift [% / Sr] Hysteresis [% / Sr] Switching frequency [Hz] Correction factors Operating temperature [C] Protection EMC

DC PNP normally open 10...36 DC 100 Yes (non-latching) yes yes < 2.5 < 10 8 10 % 0...6.5 -10...10 3...15 400 mild steel = 1 / stainless steel approx. 0.7 / brass approx. 0.5 / Al approx. 0.4 / Cu approx. 0.3 -25...70 IP 67 IEC 1000-4-2 / EN 61000-4-2: 4 kV CD / 8 kV AD IEC 1000-4-3 / EN 61000-4-3: 10 V/m, 80...1000 MHz IEC 1000-4-4 / EN 61000-4-4: 2 kV IEC 1000-4-6 / EN 61000-4-6: 10 V / 0.15...80 MHz EN 55011: class B brass special coated; active face: Pocan yellow (4 x 90) M12 connector; gold-plated contacts

Housing material Function display Switching status LED Connection Wiring

Accessories (included)
efector, inc., 805 Springdale Dr., Exton, PA 19341

2 lock nuts
We reserve the right to make technical alterations without prior notice. US - IGS204 06.03.2003

Page (8) of (12)

CORPAB-022-13_Component Cut Sheets_052013rev00


Reference Tags: 3400-EEVF-19001, 3400-EEVF-19002

Pressure sensors

PF2653
Combined pressure sensor PF26 G1 A flush mounting Freely rotatable housing 350 Zero and span adjustable Function programmable 2 outputs OUT1 = switching output OUT2 = switching output or analog output 7-segment LED display Measuring range -1.0...25 bar -15...363 PSI -0.1...2.5 MPa Application Electrical design Output Operating voltage [V] Current rating [mA] Short-circuit protection Reverse polarity protection overload protection Integrated Watchdog Voltage drop [V] Current consumption [mA] Analog output Load for analog output [ohms] Permissible overl. pressure Bursting pressure Setting range Switch-on point, SP Switch-off point, rP Analog output/lower end, ASP Analog output/upper end, AEP in steps of Programming options Accuracy / deviations (in% of the span) Turn down 1:1 Characteristics deviation *) Linearity Hysteresis Repeatability **) Long-time stability ***) Temperature coefficients (TEMPCO) in the temperature range 0...80 C (in% of the span per 10 K) - greatest TEMPCO of the zero point 100 bar 350 bar

1: 7-segment LED display, 2: Programming button, 3: tightening torque 20 Nm Type of pressure: relative pressure Hygienic systems, viscous media and liquids with suspended particles DC PNP / DC NPN 2 x normally open / closed programmable or 1 x normally open / closed programmable + 1 x analog (4...20 mA / 0...10 V, programmable 1:4) 20...30 DC 2 x 250 Yes (non-latching) yes yes <2 < 60 4...20mA / 0...10V 4...20 mA: max. (UB - 10) x 50; 700 at UB = 24 V; 0...10 V: min. 2000 1450 PSI 5070 PSI 10 MPa 35 MPa

-0.8...25.0 bar -12...363 PSI -0.08...2.50 MPa -0.9...24.9 bar -13...362 PSI -0.09...2.49 MPa -1.0...18.8 bar -15...272 PSI -0.10...1.88 MPa 5.3...25.0 bar 76...363 PSI 0.53...2.50 MPa 0.1 bar 1 PSI 0.01 MPa hysteresis / window function; N.O. / N.C; output polarity; current / voltage outputs; damping; calibration of displayed values; display can be rotated / deactivated; display unit

< 0.6 < 0.5 < 0.1 < 0.1 < 0.1

< 0.1

Page (9) of (12)

CORPAB-022-13_Component Cut Sheets_052013rev00


- greatest TEMPCO of the span Power-on delay time [s] Min. response time switching outputs [ms] Damping for the switching output (dAP) [ms] Switching frequency [Hz] Response time analog output [ms] Damping for the analog output (dAA) [ms]
efector, inc., 805 Springdale Dr., Exton, PA 19341

< 0.2 0.2 3 0; 10; 20;...100; 200;...4000 170...0.125 3 0; 100; 500; 2000
We reserve the right to make technical alterations without prior notice. US - PF2653 - 1/2 06.06.2003

Reference Tags: 3400-EEVF-19001, 3400-EEVF-19002

Page (10) of (12)

CORPAB-022-13_Component Cut Sheets_052013rev00


Reference Tags: 3400-EEVF-19001, 3400-EEVF-19002

PF2653
Display unit Operating temperature [C] Medium temperature [C] Storage temperature [C] Protection Insulation resistance [M ] Shock resistance [g] Vibration resistance [g] Switching cycles min. EMC bar, PSI, MPa -25...80 -25...80 -40...100 IP 67, III > 100 (500 V DC) 50 (DIN / IEC 68-2-27, 11ms) 20 (DIN / IEC 68-2-6, 10 - 2000 Hz) 100 million IEC 1000/4/2 ESD: 4 kV CD / 8 kV AD IEC 1000/4/3 HF radiated: 10 V/m IEC 1000/4/4 Burst: 2 KV IEC 1000/4/6 HF conducted: 10 V stainless steel (316S12) Pocan PC (Macrolon) PA EPDM/X (Santoprene) FPM (Viton) stainless steel (316S12); ceramics (99.9 % Al2 O3); PTFE red 7-segment LED display M12 connector, gold-plated contacts

Housing material

Materials (wetted parts) Function display Switching status LED System pressure, function LED Connection Wiring Programming of the output function (OUT1 / OUT2): Hno = hysteresis / normally open Hnc = hysteresis / normally closed Fno = window function / normally open Fnc = window function / normally closed Complementary outputs: output 1: = Hno, output 2: = Hnc (with the same SP / rP) Programming of the analog output (OUT2): I = current output (4...20 mA) U = voltage output (0...10 V)

Remarks

*) linearity, incl. hysteresis and repeatability; (limit value setting to DIN 16086) **) with temperature fluctuations < 10 K ***) in% of the span per year
We reserve the right to make technical alterations without prior notice. US - PF2653 - 2/2 06.06.2003

efector, inc., 805 Springdale Dr., Exton, PA 19341

Page (11) of (12)

CORPAB-022-13_Component Cut Sheets_052013rev00


Reference Tags: 3400-EEVF-19001, 3400-EEVF-19002, & 680-PU-19002

Miniature Single Switch RSF50

Vertical Plastic

The RSF50 series are compact vertically mounted devices with a single switch point. Mounting is in the top or bottom of the tank from the inside, so requires access to the inside of the tank. Typical applications include printing systems and chemical dosing equipment. They are manufactured in a variety of materials, with a choice of gasket materials, to suit most commonly used liquids. The switch action may be reversed by removing the float, inverting it and then refitting it to the stem.

Compact design User configurable N/O or N/C operation Reliable reed switch contacts Available in PVC, PPS, Polypropylene and Nylon WRAS approved Many variants are UL recognised components file number E171218

All types, except those in PVC, are also available with 1/8" NPT tapered thread.
Technical specifications Material Colour Temp. Range RSF51/52 PVC Light Grey -20 / +60 -4 / +140 0.8 RSF53 Nylon Black -20 / +75 -4 / +167 0.8 11.5mm 22.5mm RSF54 Polypropylene Opaque -20 / +100 -4 / +212 0.65 15.0 26.0 RSF56 Polyphenylene Sulphide (PPS) Grey -10 / +120* +14 / +248* 0.85 9.5 20.5

C F

Min, Fluid S.G. Must Close Level (S.G. = 1) Must Open Level (S.G. = 1)

*Maximum temperature requires ETFE cable to be specified. Electrical specifications Contact Form Switching Power Max. VA Switching Voltage AC Max. Switching Voltage DC Max. Switching Current Max. A
All ratings are for resistive load only

(RSF51/52) N/O (N/C) 10 125 150 0.5

(RSF53/54/56) N/O (N/C) 25 240 120 0.6

Standard Parts RSF51Z100J RSF52Z100J RSF53Y100RC RSF54Y100RC RSF56Y100RC Outline dimensions

Material PVC PVC Nylon Polypropylene PPS

Leadouts 1.0m PVC 7/0.2 sheathed cable 1.0m PVC 7/0.2 sheathed cable 1.0m PVC 16/0.2 UL approved 1.0m PVC 16/0.2 UL approved 1.0m PVC 16/0.2 UL approved

Gaskets Not Supplied Not Supplied Nitrile Nitrile Nitrile

30mm 6mm (0.2") max. tank wall (1.2") max.

Nylon Nut 12.7mm(0.5") dia. hole 17.3mm(0.7") for RSF52

Thread sizes RSF53/4/6 M12x1.75 Thread RSF51 PG7 RSF52 R3/8"

22mm (1.0") /18mm (0.7") for RSF52 Must close level 44mm (1.7") max. Must open level Note: Float Chamber may be inverted for alternative switch action.

12.5mm (0.5") Nom. Float Travel Gasket Seal 27mm (1.2") dia.

Contact us in USA.

t: (877) 502 5500 f: (619) 710 8540 e: sales@crydom.com w: www.crydom.com


Page (12) of (12)

15

S-ar putea să vă placă și