OPCOM3107 Commands Notebook

Legal Notices
Raisecom Technology Co., Ltd makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Raisecom Technology Co., Ltd shall not be held liable for errors contained herein or direct, indirect, special, incidental or consequential damages in connection with the furnishing, performance, or use of this material.

Warranty.
A copy of the specific warranty terms applicable to your Raisecom product and replacement parts can be obtained from Service Office.

Restricted Rights Legend.


All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Raisecom Technology Co., Ltd. The information contained in this document is subject to change without notice.

Copyright Notices.
Copyright 2008 Raisecom. All rights reserved. No part of this publication may be excerpted, reproduced, translated or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in Writing from Raisecom Technology Co., Ltd.

Trademark Notices
is the trademark of Raisecom Technology Co., Ltd. Java is a U.S. trademark of Sun Microsystems, Inc. Microsoft is a U.S. registered trademark of Microsoft Corporation. Windows NT is a U.S. registered trademark of Microsoft Corporation. Windows 2000 is a U.S. registered trademark of Microsoft Corporation. Windows XP is a U.S. registered trademark of Microsoft Corporation. Windows and MS Windows are U.S. registered trademarks of Microsoft Corporation.

Contact Information
Technical Assistance Center
The Raisecom TAC is available to all customers who need technical assistance with a Raisecom product, technology, or, solution. You can communicate with us through the following methods:

Address: Tel: Fax:

2nd Floor, South Building of Rainbow Plaza, No.11 Shangdi Information Road, Haidian District, Beijing 100085 +86-10-82883305 +86-10-82883056

World Wide Web


You can access the most current Raisecom product information on the World Wide Web at the following URL: http://www.raisecom.com

Feedback
Comments and questions about how the OPCOM3107 software works are welcomed. Please review the FAQ in the related manual, and if your question is not covered, send email by using the following web page: http://www.raisecom.com/en/xcontactus/contactus.htm. If you have comments on the OPCOM3107 specification, instead of the web page above, please send comments to: export@raisecom.com

We hope to hear from you!

CONTENTS
Chapter 1
1.1 1.2 1.3

How to Use the Command Line------------------------------------------------------- 1


Software and hardware environment --------------------------------------------------------------------------1 Command line modes -----------------------------------------------------------------------------------------------1 Command line format annotation -------------------------------------------------------------------------------1

Chapter 2
2.1
2.1.1 2.1.2 2.1.3 2.1.4 2.1.5 2.1.6 2.1.7

Definitions of Command Line --------------------------------------------------------- 2


Relevant command line of crossconnect timeslot configuration ------------------------------------2
sdh crossconnect (vc12|vc3) ----------------------------------------------------------------------------------------------------- 2 sdh crossconnect (vc12|vc3) TSSTRING ------------------------------------------------------------------------------------- 2 show sdh crossconnect ------------------------------------------------------------------------------------------------------------ 3 timeslot add sdh --------------------------------------------------------------------------------------------------------------------- 3 timeslot delete sdh ------------------------------------------------------------------------------------------------------------------ 4 show timeslot ------------------------------------------------------------------------------------------------------------------------- 5 show interface timeslot ------------------------------------------------------------------------------------------------------------- 5

2.2
2.2.1 2.2.2 2.2.3 2.2.4 2.2.5 2.2.6 2.2.7

Protection relevant commands line ----------------------------------------------------------------------------5


protect-switch enable --------------------------------------------------------------------------------------------------------------- 5 protect-switch disable -------------------------------------------------------------------------------------------------------------- 6 aps-restore-time---------------------------------------------------------------------------------------------------------------------- 6 aps-mode ------------------------------------------------------------------------------------------------------------------------------ 7 force-switch --------------------------------------------------------------------------------------------------------------------------- 8 manual-switch ------------------------------------------------------------------------------------------------------------------------ 8 show aps------------------------------------------------------------------------------------------------------------------------------- 9

2.3

SDH interface commands line------------------------------------------------------------------------------------9


2.3.1 2.3.2 2.3.3 2.3.4 2.3.5 2.3.6 2.3.7 2.3.8 2.3.9 2.3.10 2.3.11 2.3.12 2.3.13 2.3.14 2.3.15 2.3.16 2.3.17 2.3.18 2.3.19 2.3.20 2.3.21 2.3.22 2.3.23 interface stm1-opt ------------------------------------------------------------------------------------------------------------------- 9 sdh description --------------------------------------------------------------------------------------------------------------------- 10 loopback ----------------------------------------------------------------------------------------------------------------------------- 10 als --------------------------------------------------------------------------------------------------------------------------------------11 clear-statistic -------------------------------------------------------------------------------------------------------------------------11 sdh aupje-threshold --------------------------------------------------------------------------------------------------------------- 12 sdh es-threshold ------------------------------------------------------------------------------------------------------------------- 12 sdh msais-insert ------------------------------------------------------------------------------------------------------------------- 13 sdh tuais-insert --------------------------------------------------------------------------------------------------------------------- 14 sdh overhead c2 ------------------------------------------------------------------------------------------------------------------- 14 sdh overhead j0 -------------------------------------------------------------------------------------------------------------------- 15 sdh overhead j0-mode ----------------------------------------------------------------------------------------------------------- 15 sdh overhead j1 -------------------------------------------------------------------------------------------------------------------- 16 sdh overhead j1-mode ----------------------------------------------------------------------------------------------------------- 17 sdh overhead k1 ------------------------------------------------------------------------------------------------------------------- 17 sdh overhead k2 ------------------------------------------------------------------------------------------------------------------- 18 sdh overhead v5 ------------------------------------------------------------------------------------------------------------------- 18 sdh overhead k4 ------------------------------------------------------------------------------------------------------------------- 19 sdh sd-threshold ------------------------------------------------------------------------------------------------------------------- 19 show sdh-alarm -------------------------------------------------------------------------------------------------------------------- 20 show interface timeslot-occupy ------------------------------------------------------------------------------------------------ 20 show interface stm1--------------------------------------------------------------------------------------------------------------- 21 show interface ---------------------------------------------------------------------------------------------------------------------- 22 interface e1-------------------------------------------------------------------------------------------------------------------------- 22 e1-loopback ------------------------------------------------------------------------------------------------------------------------- 23 show interface ---------------------------------------------------------------------------------------------------------------------- 23

2.4
2.4.1 2.4.2 2.4.3

Commands of E1 interface -------------------------------------------------------------------------------------- 22

2.5
2.5.1 2.5.2 2.5.3 2.5.4 2.5.5 2.5.6 2.5.7

Commands of ETH interface ------------------------------------------------------------------------------------ 24


automdi------------------------------------------------------------------------------------------------------------------------------- 24 autonegotiate ----------------------------------------------------------------------------------------------------------------------- 24 clear statistic ------------------------------------------------------------------------------------------------------------------------ 24 speed (10|100) duplex (full-duplex|half-duplex)---------------------------------------------------------------------------- 25 interface eth ------------------------------------------------------------------------------------------------------------------------- 25 show interface ---------------------------------------------------------------------------------------------------------------------- 26 shutdown----------------------------------------------------------------------------------------------------------------------------- 26

2.6
2.6.1 2.6.2

Commands of EOS interface ----------------------------------------------------------------------------------- 27


interface eos ------------------------------------------------------------------------------------------------------------------------ 27 clear statistic ------------------------------------------------------------------------------------------------------------------------ 27

2.6.3 2.6.4 2.6.5 2.6.6 2.6.7

encapsulation ----------------------------------------------------------------------------------------------------------------------- 28 gfp-fcs -------------------------------------------------------------------------------------------------------------------------------- 28 lcas ------------------------------------------------------------------------------------------------------------------------------------ 29 show interface eos ---------------------------------------------------------------------------------------------------------------- 29 show interface ---------------------------------------------------------------------------------------------------------------------- 30

2.7

Commands of ETH switch function -------------------------------------------------------------------------- 30


2.7.1 2.7.2 2.7.3 2.7.4 2.7.5 2.7.6 2.7.7 2.7.8 2.7.9 2.7.10 2.7.11 2.7.12 2.7.13 2.7.14 2.7.15 2.7.16 2.7.17 2.7.18 2.7.19 2.7.20 2.7.21 2.7.22 2.7.23 2.7.24 2.7.25 2.7.26 2.7.27 2.7.28 2.7.29 2.7.30 2.7.31 2.7.32 rate-limit ------------------------------------------------------------------------------------------------------------------------------ 30 show rate-limit ---------------------------------------------------------------------------------------------------------------------- 31 strom-control-global --------------------------------------------------------------------------------------------------------------- 31 storm-control-global rate --------------------------------------------------------------------------------------------------------- 32 show strom-control-global ------------------------------------------------------------------------------------------------------- 32 vlan ------------------------------------------------------------------------------------------------------------------------------------ 33 state ----------------------------------------------------------------------------------------------------------------------------------- 33 interface switchport --------------------------------------------------------------------------------------------------------------- 34 switchport ---------------------------------------------------------------------------------------------------------------------------- 34 switchport access vlan ----------------------------------------------------------------------------------------------------------- 35 switchport dot1q-tunnel vlan ---------------------------------------------------------------------------------------------------- 35 switchport trunk allowed vlan list ---------------------------------------------------------------------------------------------- 35 switchport hybrid allowed vlan ------------------------------------------------------------------------------------------------- 36 switchport mode ------------------------------------------------------------------------------------------------------------------- 36 switchport vlan --------------------------------------------------------------------------------------------------------------------- 36 show interface ---------------------------------------------------------------------------------------------------------------------- 37 show esw ---------------------------------------------------------------------------------------------------------------------------- 37 show interface switchport-------------------------------------------------------------------------------------------------------- 37 show vlan ---------------------------------------------------------------------------------------------------------------------------- 38 qos ------------------------------------------------------------------------------------------------------------------------------------ 38 qos default-cos --------------------------------------------------------------------------------------------------------------------- 39 qos trust cos ------------------------------------------------------------------------------------------------------------------------ 39 qos map cos-queue --------------------------------------------------------------------------------------------------------------- 40 show qos----------------------------------------------------------------------------------------------------------------------------- 40 mac-address-table aging-time-------------------------------------------------------------------------------------------------- 41 no mac-address-table aging-time---------------------------------------------------------------------------------------------- 41 mac-address-table learning ----------------------------------------------------------------------------------------------------- 42 mac-address-table static HHHH.HHHH.HHHH vlan <2-4094> port <1-4>------------------------------------------ 42 mac-polling -------------------------------------------------------------------------------------------------------------------------- 43 clear mac-address-table --------------------------------------------------------------------------------------------------------- 44 search mac-address -------------------------------------------------------------------------------------------------------------- 44 show mac ---------------------------------------------------------------------------------------------------------------------------- 45 device clock local ------------------------------------------------------------------------------------------------------------------ 46 device clock sdh-port ------------------------------------------------------------------------------------------------------------- 46 device clock e1 --------------------------------------------------------------------------------------------------------------------- 47 device clock clear local----------------------------------------------------------------------------------------------------------- 48 device clock clear sdh-port ------------------------------------------------------------------------------------------------------ 48 device clock clear e1 ------------------------------------------------------------------------------------------------------------- 49 device clock force-switch local ------------------------------------------------------------------------------------------------- 49 device clock force-switch sdh-port -------------------------------------------------------------------------------------------- 50 device clock force-switch e1 ---------------------------------------------------------------------------------------------------- 50 device clock lockout local-------------------------------------------------------------------------------------------------------- 51 device clock lockout sdh-port --------------------------------------------------------------------------------------------------- 51 device clock lockout e1 ---------------------------------------------------------------------------------------------------------- 52 device clock manual-switch local ---------------------------------------------------------------------------------------------- 52 device clock manual-switch sdh-port ----------------------------------------------------------------------------------------- 53 device clock manual-switch e1------------------------------------------------------------------------------------------------- 53 device clock pll --------------------------------------------------------------------------------------------------------------------- 54 device clock reset local ---------------------------------------------------------------------------------------------------------- 54 device clock reset sdh-port------------------------------------------------------------------------------------------------------ 55 device clock reset e1 ------------------------------------------------------------------------------------------------------------- 55 device clock wait-to-restore-time ---------------------------------------------------------------------------------------------- 55 device clock ssm------------------------------------------------------------------------------------------------------------------- 56 device clock local id --------------------------------------------------------------------------------------------------------------- 57 device clock sdh-port id ---------------------------------------------------------------------------------------------------------- 57 device clock e1 id------------------------------------------------------------------------------------------------------------------ 57 show device clock ----------------------------------------------------------------------------------------------------------------- 58 dcc select ---------------------------------------------------------------------------------------------------------------------------- 58 e1-retiming-src --------------------------------------------------------------------------------------------------------------------- 59 e1 <1-8> retiming ------------------------------------------------------------------------------------------------------------------ 60 show info----------------------------------------------------------------------------------------------------------------------------- 60 show shelf --------------------------------------------------------------------------------------------------------------------------- 61

2.8

Relevant command of clock ------------------------------------------------------------------------------------ 46


2.8.1 2.8.2 2.8.3 2.8.4 2.8.5 2.8.6 2.8.7 2.8.8 2.8.9 2.8.10 2.8.11 2.8.12 2.8.13 2.8.14 2.8.15 2.8.16 2.8.17 2.8.18 2.8.19 2.8.20 2.8.21 2.8.22 2.8.23 2.8.24 2.8.25

2.9
2.9.1 2.9.2 2.9.3 2.9.4 2.9.5

System Configuration Command Line ---------------------------------------------------------------------- 58

Chapter 3 Reference Materials ---------------------------------------------------------------------62 Appendix A Acronyms ------------------------------------------------------------------------------------66

Preface
About This Manual
This manual introduces primary functions of the configuration management software for OPCOM3107 series products.

Who Should Read This Manual


This manual is a valuable reference for sales and marketing staff, after service staff and telecommunication network designers. For those who want to have an overview of the features, applications, structure and specifications of OPCOM3107 device, this is also a recommended document.

Organization
This manual is an introduction of the main functions of OPCOM3107. To have a quick grasp of the using of OPCOM3107, please read this manual carefully. The manual is composed of the following chapters: Chapter 1 How to Use the Command Line This chapter briefly introduces how to access control and configure OPCOM3107 device by the command line. Chapter 2 Definitions of Command Line This chapter mainly introduces the supported configuration command line in OPCOM3107 device software. Chapter 3 Reference Materials Appendix A Acronyms

Compliance
The RC series products developed by Raisecom are strictly complied with the following standards as well as ITU-T, IEEE, IETF and related standards from other international telecommunication standard organizations: YD/T900-1997 SDH Equipment Technical Requirements - Clock YD/T973-1998 SDH 155Mb/s and 622Mb/s Technical conditions of optical transmitter module and receiver module YD/T1017-1999 Network node interface for the Synchronous Digital Hierarchy (SDH) YD/T1022-1999 Requirement of synchronous digital hierarchy (SDH) equipment function YD/T1078-2000 SDH Transmission Network Technique Requirements-Interworking of Network

Protection Architectures YD/T1111.1-2001 Technical Requirements of SDH Optical Transmitter/Optical Receiver Modules2.488320 Gb/s Optical Receiver Modules YD/T1111.2- 2001 Technical Requirements of SHD Optical Transmitter/Optical Receiver Modules2.488320 Gb/s Optical Transmitter Modules YD/T1179- 2002 Technical Specification of Ethernet over SDH G.703 Physical/electrical characteristics of hierarchical digital interfaces G.704 Synchronous frame structures used at 1544, 6312, 2048, 8448 and 44 736 kbit/s hierarchical levels G.707 Network node interface for the synchronous digital hierarchy (SDH) G.774 Synchronous digital hierarchy (SDH) - Management information model for the network element view G.781 Synchronization layer functions G.783 Characteristics of synchronous digital hierarchy (SDH) equipment functional blocks G.784 Synchronous digital hierarchy (SDH) management G.803 Architecture of transport networks based on the synchronous digital hierarchy (SDH) G.813 Timing characteristics of SDH equipment slave clocks (SEC) G.823 The control of jitter and wander within digital networks which are based on the 2048 kbit/s hierarchy G.825 The control of jitter and wander within digital networks which are based on the synchronous digital hierarchy (SDH) G.826 End-to-end error performance parameters and objectives for international, constant bit-rate digital paths and connections G.828 Error performance parameters and objectives for international, constant bit-rate synchronous digital paths G.829 Error performance events for SDH multiplex and regenerator sections G.831 Management capabilities of transport networks based on the synchronous digital hierarchy (SDH) G.841 Types and characteristics of SDH network protection architectures G.842 Interworking of SDH network protection architectures G.957 Optical interfaces for equipments and systems relating to the synchronous digital hierarchy G.691 Optical interfaces for single channel STM-64 and other SDH systems with optical amplifiers G.664 Optical safety procedures and requirements for optical transport systems I.731 ATM Types and general characteristics of ATM equipment I.732 ATM Functional characteristics of ATM equipment IEEE 802.1Q Virtual Local Area Networks (LANs) IEEE 802.1p Traffic Class Expediting and Dynamic Multicast Filtering

IEEE 802.3 CSMA/CD Access Method and Physical Layer Instruction

www.raisecom.com

User Manual

Chapter 1 How to Use the Command Line

1.1 Software and hardware environment


Operation environment of hardware: OPCOM3107 platform PC serial interface Operation environment of software: WIN98/WIN2000/WINDOWS XP

1.2 Command line modes


Mode Common EXEC mode Mode description Configure the basic information and show the parameters etc. at terminal device. Configure the basic information such as system time, displaying parameters, ect. Running information of OPCOM3107 can not be configured in this mode. Configure all running parameters of OPCOM3107. Configure parameters of Ethernet NM (Network Management) interface, ETH interfaces and SDH interface. Access Login the device and input the user name and password. Prompts OPCOM3107>

Privileged EXEC mode

Use enable command in common EXECmode.

OPCOM3107#

Global configuration Interface configuration

Use config command in Privileged EXEC mode.

OPCOM3107 (config )#

Input interface [eth/eos/stm-1/e1 OPCOM3107 (config-xxx/n)# /switch/snmp/dcc] in Global xxx: interface index. configuration mode.

Table 1-1 Command Line Modes

1.3 Command line format annotation


1. The command is ended at key word of the first parameter. 2. All optional parameters should be bracketed into a [], regardless of how many parameters there are. Parameters should be separated by |. 3. In the case of any choices of required parameters or command keywords, all parameters and command keywords should be bracketed into a (). Parameters and command keywords should be separated by |.

www.raisecom.com

User Manual

Chapter 2 Definitions of Command Line

2.1 Relevant command line of crossconnect timeslot configuration


2.1.1 sdh crossconnect (vc12|vc3)
[Function] Configure device crossconnect, no command is used to delete crossconnect. sdh crossconnect (vc12|vc3) source-port <1-2> timeslot {1-63} destination-port <1-2> timeslot {1-63} no sdh crossconnect (vc12|vc3) source-port <1-2> timeslot {1-63} destination-port <1-2> timeslot {1-63} [Parameter] (vc12|vc3) : select crossconnect type; vc12: VC12-level crossconnect; vc3: VC3-level cross-connect. <1-2>: sdh port index. <1-63> : sdh timeslot. TSSTRING : timeslot string to configure, use , to separate single timeslots; use - to indicate interzone, for example 1, 3-5 means timeslot 1, 3, 4, 5. [Command modes] Global configuration mode [Example] Create vc12-level crossconnect from optical interface 1 timeslot 1 to optical interface 2 timeslot 2: OPCOM3107 (config)# sdh crossconnet vc12 source-port 1 timeslot 1 destination-port 2 timeslot 5 [Related commands] Command show sdh crossconnect Description Show sdh port crossconnect configuration information.

2.1.2

sdh crossconnect (vc12|vc3) TSSTRING


[Function] Configure crossconnect for device optical interface corresponding timeslots. sdh crossconnect (vc12|vc3) TSSTRING [Parameter]
2

www.raisecom.com

User Manual

(vc12|vc3) : select crossconnect type; vc12: VC12-level crossconnect; vc3: VC3- level cross-connect. TSSTRING : timeslot string to configure, use , to separate single timeslot; use - to indicate interzone, for example 1, 3-5 means timeslot 1, 3, 4, 5. [Command modes] Global configuration mode [Example] Create vc12-level crossconnect from optical interface 1 timeslot 1-8 to optical interface 2 timeslot 1-8: OPCOM3107 (config)# sdh crossconnet vc12 1-8 [Related commands] Command Description

show sdh crossconnect Show sdh port crossconnect configuration information.

2.1.3

show sdh crossconnect


[Function] Show configured crossconnect. show sdh crossconnect [Command modes] Privileged EXEC mode, Global configuration mode [Example] Show crossconnect configuration information: OPCOM3107# show sdh crossconnect [Related commands] Command sdh crossconnect Description Configure sdh port timeslot crossconnect.

2.1.4

timeslot add sdh


[Function] Add one mapping between E1/EOS interface and sdh timeslot, which can assign backboard timeslot. timeslot add sdh <1-2> (vc12|vc3) SDHTSSTRING [SVCTSSTRING] [Parameter] <1-2>: sdh port index. (vc12|vc3) : timeslot assignment type selection ; vc12: timeslot type is VC12; vc3: means
3

www.raisecom.com timeslot is VC3; SDHTSSTRING: SDH timeslot string to configure. SVCTSSTRING: backboard timeslot string to configure. [Command modes] EOS and E1 interface configuration mode [Executing Command Instruction]

User Manual

System automatically assigns backboard timeslot if not input SVCTSSTRING parameters. [Example] Add timeslot 1 at E1 port 1, meanwhile create an inner crossconnect to SDH optical interface 1 timeslot 1: OPCOM3107 (config-e1/1)# timeslot add sdh 1 vc12 1 1 [Related commands] Command show timeslot Description Show configuration information assigned by timeslot.

2.1.5

timeslot delete sdh


[Function] Delete one mapping between E1/EOS interface and sdh timeslot. timeslot delelte sdh <1-2> (vc12|vc3) SDHTSSTRING [Parameter] <1-2>: sdh port index. (vc12|vc3) : timeslot assignment type selection ; vc12: timeslot type is VC12; vc3: means timeslot is VC3; SDHTSSTRING: SDH timeslot string to configure. [Command modes] EOS and E1 interface configuration mode [Example] Delete timeslot 1 under E1 port 1: OPCOM3107 (config-e1/1)# timeslot del sdh 1 vc12 1 [Related commands] Command show timeslot Description Show timeslot assigning configuration information.

www.raisecom.com

User Manual

2.1.6

show timeslot
[Function] Show relevant information of timeslot assignment. show timeslot [Command modes] Privileged EXEC mode, Global configuraiton mode [Example] Show timeslot assignment information: OPCOM3107# show timeslot [Related commands] Commands timeslot add sdh timeslot delete sdh Description Configure timeslot assignment. Delete timeslot assignment.

2.1.7

show interface timeslot


[Function] Show relevant information of timeslot assignment at EOS and E1 interface. show interface timeslot [Command modes] EOS and E1 interface configuraiton mode [Example] Show timeslot configuration status at EOS interface 2: OPCOM3107(config-eos/0/2)# show interace timeslot [Related commands] Commands timeslot add sdh timeslot delete sdh Description Configure timeslot assignment. Delete timeslot assignment.

2.2 Protection relevant commands line


2.2.1 protect-switch enable
[Function] Configure protect-switch type and enable the function. protect-switch enable [type (path|ms)] [Parameter]
5

www.raisecom.com path|ms: type of protect-switch; path: path protection; ms: multiplex-section protection. [Default] Protect-switch enable and in path protection mode [Command modes] Global configuration mode [Example] Configure path protection protect-switch enable: OPCOM3107# config OPCOM3107(config)# protect-switch enable type path
Create successfully

User Manual

[Related commands] Commands show aps Description Show protect-switch configuration information.

2.2.2

protect-switch disable
[Function] This command is used to disable protect-switch. protect-switch disable [Command modes] Global configuration mode [Example] Configure protect-switch disable: OPCOM3107# config OPCOM3107 (config)# protect-switch disable
Set successfully

[Related commands] Commands show aps Description Show protect-switch configuration information.

2.2.3

aps-restore-time
[Function] Configure automatically protect-switch restore time.
6

www.raisecom.com aps-restore-time <0-12> [Parameter] <0-12>: restore time, unit: minute [Default] 12 minutes [Command modes] Global configuration mode [Executing Command Instruction]

User Manual

0 means no need to wait for aps restore, the link switch to master link directly after it recovers. [Example] Configure auto-protect-switch restore time to be 3: OPCOM3107# config OPCOM3107 (config)# aps-restore-time 3 Set successfully [Related commands] Commands show aps Description Show protect-switch configuration information.

2.2.4

aps-mode
[Function] Configure whether aps-mode enable. aps-mode (revertive|nonrevertive) [Parameter] (revertive|nonrevertive): whether enable auto-revert [Default] Revert [Command modes] Global configuration mode [Example] Configure aps-mode to be nonrevertive: OPCOM3107# config OPCOM3107(config)# aps-mode nonrevertive
Set successfully

[Related commands]
7

www.raisecom.com Commands show aps Description Show protect-switch configuration information.

User Manual

2.2.5

force-switch
[Function] Configure force-switch working path for assigned timeslot. force-switch {work-line|protection-line|clear} [{vc3|vc12} TSSTRING] [Parameter] {work-line|protection-line|clear}: select parameter to operate work-line: force to work-line protection-line: force to protection line clear: clear force-siwtch TSSTRING: timeslot string to operate; use , to separate single timeslot; use - to indicates interzone. For example: 1, 3-5 means timeslot 1 and timeslot 3, 4, 5. [Command modes] Global configuration mode [Executing Command Instruction] Force-switch is available only when configured relevant timeslot and protection enable. [Example] OPCOM3107# config OPCOM3107 (config)# force-switch work-line vc12 1,3-6
Set successfully

[Related commands] Commands show aps Description Show protect-switch configuration information.

2.2.6

manual-switch
[Function] Force switch working line for assigned timeslot. manual-switch {work-line|protection-line|clear} [{vc3|vc12} TSSTRING] [Parameter] {work-line|protection-line|clear}: select parameter to operate work-line: force to work line protection-line: force to protection line
8

www.raisecom.com clear: clear force siwtch

User Manual

TSSTRING: timeslot string to operate; use , to separate single timeslot; use - to indicare interzone. For example: 1, 3-5 means timeslot 1 and timeslot 3, 4, 5. [Command modes] Global configuration mode [Executing Command Instruction] Manual-switch can be operated only in condition that there is protection pair and the protection pair is valid. [Example] OPCOM3107# config OPCOM3107 (config)# manual-switch work-line vc12 1,3-6 Set successfully [Related commands] Commands show aps Description Show protect-switch configuration information.

2.2.7

show aps
[Function] Show protect-switch configuration status. show aps [Command modes] Privileged EXEC mode, Global configuration mode [Example] OPCOM3107# config OPCOM3107 (config)# show aps

2.3 SDH interface commands line


2.3.1 interface stm1-opt
[Function] Enter interface configuration mode. interface stm1-opt <1-2> [Parameter] <1-2>: STM1 optical interface ID. [Command modes]
9

www.raisecom.com Global configuration mode, STM1 interface configuration mode [Example] Enter STM1 optical interface 1: OPCOM3107 (config)# interface stm1-opt 1 [Related commands] Commands show interface Description Show interface information.

User Manual

2.3.2

sdh description
[Function] Configure interface description information. sdh description STRING [Parameter] STRING: interface description information [Command modes] Interface configuration mode [Executing Command Instruction] Use character ^ instead of character space in the interface description. [Example] Configure optical interface description information as aisecom-inter-01: OPCOM3107 (config-stm1-opt/0/1)# sdh description raisecom-inter-01 [Related commands] Commands show interface Description Show interface information.

2.3.3

loopback
[Function] Configure STM-1 port loopback, no command can used to cancel loopback. loopback external no loopback [Parameter] external: loopback type. External means remote port external loopback. [Default]
10

www.raisecom.com No loopback [Command modes] Interface configuration mode [Example] Configure local optical interface external loopback: OPCOM3107 (config-stm1-opt/0/1)# loopback external [Related commands] Commands show interface Description Show interface information.

User Manual

2.3.4

als
[Function] Configure STM-1 port als function. als (enable|disable) [Parameter] (enable|disable): als function enable/disable. [Default] disable [Command modes] Interface configuration mode [Example] Enable optical interface als function: OPCOM3107 (config-stm1-opt/0/1)# als enable [Related commands] Commands show interface Description Show interface information.

2.3.5

clear-statistic
[Function] Reset all current internal statistics information of sdh. [Command modes] Interface configuration mode [Example]
11

www.raisecom.com Reset all current internal statistics information of sdh: OPCOM3107 (config-stm1-opt/0/1)# reset-statistic

User Manual

2.3.6

sdh aupje-threshold
[Function] Configure SDH high order path AU pointer to adjust threshold. [Command Format] sdh aupje-threshold (positive|negative) <1-65535> [Parameter] (positive|negative): select the pointer to adjust direction to set, positive means adjust pointer at positive direction; negative means adjust pointer at negative direction. <1-65535>: threshold value. [Default] Threshold value is 900 by default. [Command modes] Interface configuration mode [Example] Set positive pointer to adjust threshold value as 300: OPCOM3107 (config-stm1-opt/0/1)# sdh aupje-threshold positive 300 [Related commands] Commands show interface Description Show interface information.

2.3.7

sdh es-threshold
[Function] Configure SDH error bit second threshold. sdh es-threshold (regenerator-section|multiplex-section|higher-path|lower-path) <1-900> [Parameter] (regenerator-section|multiplex-section|higher-path|lower-path): select the section to set; regenerator-section: regenerator section; multiplex-section: multiplex section; higher-path: higher order path; lower-path: lower order path; <1-900>: error bit second threshold value.
12

www.raisecom.com [Default] All error second threshold values are 900. [Command modes] Interface configuration mode [Example] Set multiplex section error second threshold value as 300: OPCOM3107 (config-stm1-opt/0/1)# sdh es-threshold multiplex-section 300 [Related commands] Commands show interface Description Show interface information.

User Manual

2.3.8

sdh msais-insert
[Function] Enable/disable MS-AIS insert function. sdh msais-insert (rstim|msexc) (enable|disable) [Parameter] (rstim|msexc): conditions of insert MS-AIS function; rstim: insert when regenerator section TIM alarms; msexc: insert when multiplex section EXC alarms; (enable|disable): enable: insert enable; disable: insert disable. [Default] Disable, disable MS-AIS insert function when regenerator section TIM and multiplex section EXC alarms. [Command modes] Interface configuration mode [Example] Insert MS-AIS when regenerator section TIM alarms: OPCOM3107 (config-stm1-opt/0/1)# sdh msais-insert rstim enable [Related commands] Commands show interface Description Show interface information.

13

www.raisecom.com

User Manual

2.3.9

sdh tuais-insert
[Function] Enable/disable TU-AIS insert function. sdh tuais-insert (hpexc|hpplm|hptim) (enable|disable) [Parameter] (hpexc|hpplm|hptim): conditions of insert TU-AIS function; hpexc: insert when higher order path EXC alarms; hpplm: insert when higher order path PLM alarms; hptim: insert when higher order path TIM alarms; (enable|disable): enable: insert enable; disable: insert disable. [Default] Disable: disable TU-AIS insert function when higher-path EXC, higher-path PLM and higherpath TIM alarms. [Command modes] Interface configuration mode [Example] Insert TU-AIS when higher order path PLM alarm happens at STM optical port 1: OPCOM3107 (config-stm1-opt/0/1)# sdh tuais-insert hpplm enable [Related commands] Commands show interface Description Show SDH interface information.

2.3.10 sdh overhead c2


[Function] Configure expected receiving and transmitting higher order path C2 byte. sdh overhead c2 [vc4 <1-1>] [vc3 <1-3>] [transmit BYTE] [expected BYTE] [Parameter] vc4: configurable vc4 index, only 1 vc4 at present; vc3: select vc3 index for configuring, valued from 1-3 for configuring vc3 C2 byte, this parameter is omitted when configure vc4 C2 byte; BYTE: C2 byte information expects to receive, hexadecimal digitals; BYTE: C2 byte information to transmit, hexadecimal digitals. [Default] C2 byte information to transmit and expect to receive are both 0x02.
14

www.raisecom.com [Command modes] STM1 interface configuration mode [Example]

User Manual

Configure C2 byte information to transmit and expect to receive to be both 0x03: OPCOM3107 (config-stm1-opt/0/1)# sdh overhead c2 expected 0x03 transmit 0x03 [Related commands] Commands show interface Description Show interface information.

2.3.11 sdh overhead j0


[Function] Configure regenerator section trace byte J0 string expects to receive and to transmit. sdh overhead j0 [expected EXPMSG] [transmit XMITMSG] [Parameter] EXPMSG: j0 string expects to receive; XMITMSG: j0 string expects to transmit. [Default] J0 string expects to receive and to transmit are both Raisecom-Opcom. [Command modes] Interface configuration mode [Executing Command Instruction] The character number must not more than 16 in factual command operation, use ^ to instead of space character. [Example] Configure j0 string to transmit and expects to receive to be both opcom3107: OPCOM3107(config-stm1-opt/0/1)# opcom3107 [Related commands] Commands show interface Description Show interface information. sdh overhead j0 expected opcom3107 transmit

2.3.12 sdh overhead j0-mode


[Function] Configure regenerator section trace byte J0 string expects to receive and to transmit.
15

www.raisecom.com sdh overhead j0-mode (one-byte | sixteen-byte) [Parameter] one-byte: use j0 one byte mode; sixteen-byte: use j0 16 byte mode. [Default] J0 16 byte mode. [Command modes] Interface configuration mode [Example] Configure j0 16 byte mode: OPCOM3107 (config-stm1-opt/0/1)# sdh overhead j0-mode sixteen-byte [Related commands] Commands show interface Description Show interface information.

User Manual

2.3.13 sdh overhead j1


[Function] Configure HP trace byte J1 string expects to receive and to transmit. sdh overhead j1 [vc4 <1-1>] [vc3 <1-3>] [expected EXPMSG] [transmit XMITMSG] [Parameter] vc4: means vc4 index has been configured, only 1 vc4 at present; vc3: means select vc3 index for configuring, valued from 1-3 for configuring vc3 J1 byte, this parameter is omitted when configure vc4 J1 byte; EXPMSG: j1 string expects to receive; XMITMSG: j1 string to transmit. [Default] J1 string expects to receive and transmit are both Raisecom-Opcom. [Command modes] Interface configuration mode [Executing Command Instruction] The character number must not more than 16 in factual command operation, use ^ to instead of space character. [Example] Configure j1 string to transmit and expects to receive to be both opcom3107: OPCOM3107(config-stm1-opt/0/1)# sdh overhead j1 expected opcom3107
16

transmit

www.raisecom.com opcom3107 [Related commands] Commands show interface Description Show interface information.

User Manual

2.3.14 sdh overhead j1-mode


[Function] Configure HP trace byte J1 string expects to receive and transmit. sdh overhead j1-mode (sixteen-byte | sixtyfour-byte) [Parameter] sixtyfour-byte: use j1 64 byte mode; sixteen-byte: use j1 16 byte mode. [Default] J1 16 byte mode. [Command modes] Interface configuration mode [Example] Configure j1 16 byte mode: OPCOM3107(config-stm1-opt/0/1)# sdh overhead j1-mode sixteen-byte [Related commands] Commands show interface Description Show interface information.

2.3.15 sdh overhead k1


[Function] Configure k1 byte to transmit. sdh overhead k1 BYTE [Parameter] BYTE: k1 byte to transmit. [Default] K1 byte to transmit is 0x0. [Command modes] Interface configuration mode [Example]
17

www.raisecom.com Configure transmit k1 byte 0x0: OPCOM3107(config-stm1-opt/1)# sdh overhead k1 0x0 [Related commands] Commands show interface Description Show interface information.

User Manual

2.3.16 sdh overhead k2


[Function] Configure k2 byte to transmit. sdh overhead k2 BYTE [Parameter] BYTE: k2 byte to transmit. [Default] K2 byte to transmit is 0x0. [Command modes] Interface configuration mode [Example] Configure transmit k2 byte 0x0: OPCOM3107(config-stm1-opt/1)# sdh overhead k2 0x0 [Related commands] Commands show interface Description Show interface information.

2.3.17 sdh overhead v5


[Function] Configure v5 byte expects to receive and to transmit. sdh overhead v5 [vc4 <1-1>] [vc12 <1-63>] [expected BYTE] [transmit BYTE] [Parameter] vc4: vc4 index, only 1 vc4 at present; vc12: vc12 timeslot (TS) index, <1-63>; BYTE: v5 byte information expects to receive; BYTE: v5 byte information to transmit. [Default] Vc12 v5 is 0x2 by default.
18

www.raisecom.com [Command modes] Interface configuration mode [Example] Configure VC12-1 transmit and expect v5 byte to be both 0x5:

User Manual

OPCOM3107(config-stm1-opt/0/1)# sdh overhead v5 vc12 1 expected 0x5 transmit 0x5 [Related commands] Commands show interface Description Show interface information.

2.3.18 sdh overhead k4


[Function] Configure LP extended signal tag k4 byte expects to receive and to transmit. sdh overhead k4 [vc4 <1-1>] [vc12 <1-63>] [expected BYTE] [transmit BYTE] [Parameter] vc4: vc4 index, only 1 vc4 at present; vc12: vc12 timeslot (TS) index, <1-63>; BYTE: k4 byte information expects to receive; BYTE: k4 byte information to transmit. [Default] Vc12 k4 is 0xb by default. [Command modes] Interface configuration mode [Example] Configure VC12-1 tranmist and expect k4 byte to be both 0xd: OPCOM3107(config-stm1-opt/0/1)# sdh overhead k4 vc12 1 expected 0xd transmit 0xd [Related commands] Commands show interface Description Show interface information.

2.3.19 sdh sd-threshold


[Function] Configure SDH signal degrade threshold. sdh sd-threshold (regenerator-section|multiplex-section|higher-path|lower-path) <6-8> [Parameter]
19

www.raisecom.com

User Manual

(regenerator-section|multiplex-section|higher-path|lower-path): select section to set; regenerator-section: regenerator-section; multiplex-section: multiplex-section ; higher-part: higher order path ; lower-path: lower order path ; <6-8>: signal degrade threshold; 6 means threshold is 10-6; 7 means threshold is 10-7; 8 means threshold is 10-8. [Default] Threshold for all types of signal degrade is 6. [Command modes] Interface configuration mode [Example] Configure multiplex section signal degrade threshold to be 10-6: OPCOM3107(config-stm1-opt/0/1)# sdh sd-threshold multiplex-section 6 [Related commands] Commands show interface Description Show interface information.

2.3.20 show sdh-alarm


[Function] Show all SDH alarm of port at present. show sdh-alarm [Command modes] Interface configuration mode [Example] Show STM1 port 1 all SDH alarm at present: OPCOM3107(config-stm1-opt/0/1)#show sdh-alarm

2.3.21 show interface timeslot-occupy


[Function] Show SDH timeslot occupation status at present. show interface timeslot-occupy [Command modes] Interface configuration mode
20

www.raisecom.com [Command Execute Echo] sdh-port timeslot state

User Manual

----------------------------------------1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 vc3 vc3 vc3 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 vc12 1 2 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NoOccupied NoOccupied NoOccupied Occupied by svc Occupied by svc Occupied by svc Occupied by svc Occupied by svc Occupied by svc Occupied by svc Occupied by svc NoOccupied Occupied by xc NoOccupied NoOccupied NoOccupied NoOccupied NoOccupied NoOccupied

17 NoOccupied

[Example] Show timeslot occupation status at present port: OPCOM3107(config-stm1-opt/0/1)# show interface timeslot-occupy

2.3.22 show interface stm1


[Function] Show sdh interface configuration information. show interface stm1 <1-2> [Parameter] <1-2>: sdh interface number [Command modes] Global configuration mode, Interface configuration mode [Example]
21

www.raisecom.com Show sdh interface 1 information: OPCOM3107 (config-stm1-opt/0/1)# show interface sdh 1 [Related commands] Commands show interface show interface stm1 Description Show interface configuration information. Show interface configuration information.

User Manual

2.3.23 show interface


[Function] Show configuration of current STM port. show interface [Command modes] Interface configuration mode [Example] Show STM optical port 2 configuration information: OPCOM3107(config-stm1-opt/0/2)# show interface

2.4 Commands of E1 interface


2.4.1 interface e1
[Function] Enter E1 interface. interface e1 <1-8> [Parameter] <1-8>: E1 interface index [Command modes] Global configuration mode [Example] Enter E1 interface 1: OPCOM3107(config)# interface e1 1 [Related commands] Commands show interface Description Show interface configuration information.

22

www.raisecom.com

User Manual

2.4.2

e1-loopback
[Function] Configure E1 loopback and cancel E1 loopback. e1-loopback (internal | external) no e1-loopback [Parameter] (internal|external): internal: local interface internal loopback; external: remote interface external loopback. [Default] No loopback [Command modes] E1 interface configuration mode [Example] Configure E1 remote loopback: OPCOM3107(config-e1/0/1)# e1-loopback external Cancel E1 remote loopback: OPCOM3107(config-e1/0/1)# no e1-loopback [Related commands] Commands show interface Description Show interface configuration information.

2.4.3

show interface
[Function] Show E1 interface configuration information. show interface [Command modes] E1 interface configuration mode [Example] Show E1 interface information: OPCOM3107(config-e1/0/1)# show interface

23

www.raisecom.com

User Manual

2.5 Commands of ETH interface


2.5.1 automdi
[Function] Configure Auto-MDI function; no command can be used to disable the function. [no] automdi [Default] Auto-MDI function enable [Command modes] ETH interface mode [Example] Enable ETH interface Auto-MDI function: OPCOM3107(config-eth/0/1)# automdi [Related commands] Commands show interface Description Show interface configuration information.

2.5.2

autonegotiate
[Function] Configure Auto-Negotiation function; no command can be used to disable the function. [no] autonegotiate [Default] Auto-Negotiation function enable [Command modes] ETH interface mode [Example] Disable ETH interface Auto-Negotiation function: OPCOM3107(config-eth/0/1)# no autonegotiate [Related commands] Commands show interface Description Show interface configuration information.

2.5.3

clear statistic
[Function] Clear statistical information.
24

www.raisecom.com clear statistic [Command modes] ETH interface mode, Switch interface mode [Example] Clear ETH flow statistic information: OPCOM3107(config-eth/0/1)# clear statistic [Related commands] Commands show interface Description Show interface configuration information.

User Manual

2.5.4

speed (10|100) duplex (full-duplex|half-duplex)


[Function] Configure duplex rate of ETH interface. speed (10|100) duplex (full-duplex|half-duplex) [Parameter] (10|100): interface rate, unit: M; (full-duplex|half-duplex): duplex status ; full-duplex: full-duplex; half-duplex: half-duplex. [Command modes] ETH interface mode [Executing Command Instruction] This configuration is valid only when interface Auto-Negotiation disable. [Example] Configure ETH interface to be 10M half-duplex: OPCOM3107(config-eth/0/1)# speed 10 duplex half-duplex [Related commands] Commands show interface Description Show interface configuration information.

2.5.5

interface eth
[Function] Enter ETH interface.
25

www.raisecom.com interface eth <1-4> [Parameter] <1-4>: ETH interface number [Command modes] Global configuration mode, ETH interface mode [Example] Enter ETH interface 1: OPCOM3107(config)# interface eth 1 [Related commands] Commands show interface Description Show interface configuration information.

User Manual

2.5.6

show interface
[Function] Show interface configuration information. show interface [Command modes] ETH interface mode [Example] Show ETH interface configuration information: OPCOM3107(config-eth/0/1)# show interface [Related commands] Commands show interface Description Show interface configuration information.

2.5.7

shutdown
[Function] This command is used to shutdown ETH interface, no command can be used to open ETH interface. shutdown no shutdown [Default] No shutdown
26

www.raisecom.com [Command modes] ETH interface configuration mode [Example] Configure ETH interface shutdown: OPCOM3107(config-eth/0/1)# shutdown [Related commands] Commands show interface Description Show interface configuration information.

User Manual

2.6 Commands of EOS interface


2.6.1 interface eos
[Function] Enter EOS interface. interface eos <1-2> [Parameter] <1-2>: EOS interface index [Command modes] Global configuration mode, EOS interface configuration mode [Example] Enter the first EOS interface: OPCOM3107(config)#interface eos 1 [Related commands] Commands show interface Description Show interface configuration information.

2.6.2

clear statistic
[Function] Clear flow statistic information clear statistic [Command modes] EOS interface mode [Example] Clear EOS flow statistic information:
27

www.raisecom.com OPCOM3107(config-eos/0/1)# clear statistic [Related commands] Commands show interface eos show interface Description Show interface configuration information. Show interface configuration information.

User Manual

2.6.3

encapsulation
[Function] Configure Ethernet encapsulation mode. encapsulation (gfp|laps) [Parameter] gfp: configure VCG encapsulation mode to be gfp; laps: configure VCG encapsulation mode to be laps. [Command modes] EOS interface configuration mode [Example] Configure VCG encapsulatin mode to be gfp: OPCOM3107(config-eos/0/1)# encapsulation gfp [Related commands] Commands show interface eos show interface Description Show interface configuration information. Show interface configuration information.

2.6.4

gfp-fcs
[Function] Configure whether enable fcs under gfp encapsulation mode. gfp-fcsenable| disable [Parameter] enable: fcs enable; disable: fcs disable. [Command modes] EOS interface configuration mode [Example]
28

www.raisecom.com Configure fcs enable: OPCOM3107(config-eos/0/1)#gfp-fcs enable [Related commands] Commands show interface eos show interface Description Show interface configuration information. Show interface configuration information.

User Manual

2.6.5

lcas
[Function] Configure whether enable lcas function. lcas (on| off) [Parameter] on: lcas enable; off: lcas disable. [Command modes] EOS interface configuration mode [Example] Configure lcas enable: OPCOM3107(config-eos/0/1)# lcas on [Related commands] Commands show interface eos show interface Description Show interface configuration information. Show interface configuration information.

2.6.6

show interface eos


[Function] Show EOS interface configuration information. show interface eos <1-2> [Parameter] <1-2>: eos interface number [Command modes] Global configuration mode [Example]
29

www.raisecom.com Show EOS interface 1 information: OPCOM3107(config-eos/0/1)# show interface eos 1 [Related commands] Commands show interface Description Show interface configuration information.

User Manual

2.6.7

show interface
[Function] Show interface configuration information. show interface [Command modes] EOS interface configuration mode [Example] Show ETH interface information: OPCOM3107(config-eos/0/1)# show interface [Related commands] Commands show interface eos Description Show EOS interface configuration information.

2.7 Commands of ETH switch function


2.7.1 rate-limit
[Function] Limit port rate, no command can be used to cancel this command. [no] rate-limit <1-1048576> [Parameter] <1-1048576>: limit the rate, unit: Kbps [Command modes] Switchport mode [Executing Command Instruction] Rate limit provides limit for bi-direction rate, since hardware rate limit range is integral times of granularity, the actual rate limit may different from configured rate. [Command Execute Echo] If the limit rate higher than 100M or lower than the rate limit granularity, error information will be displayed.
30

www.raisecom.com [Example] Configure switchport 1 rate to be 2 M: OPCOM3107(config-eswif/0/1)# rate-limit 2048 Cancel export rate limit: OPCOM3107(config-eswif/0/1)# no rate-limit [Related commands] Commands show rate-limit Description Show rate limit configuration information.

User Manual

2.7.2

show rate-limit
[Function] Show rate limit configuration information. show rate-limit [Command modes] Global configuration mode, switchport mode [Example] Show rate limit configuration information: OPCOM3107(config-esw/1)# show rate-limit [Related commands] Commands [no] rate-limit rate-limit step Description Rate limit configuration. Rate limit granularity configuration.

2.7.3

strom-control-global
[Function] Configure storm control function. storm-control-global ( broadcast | multicast | dlf | disable | all ) [Parameter] broadcast: broadcast the message; multicast: multicast and broadcast message; dlf: dlf message; all: all messages; disable: storm control disable.
31

www.raisecom.com [Command modes] Global configuration mode [Example] Configure multicast storm control enable: OPCOM3107(config)# storm-control-global multicast enable [Related commands] Commands show strom-control-global Description Show storm control configuration information.

User Manual

2.7.4

storm-control-global rate
[Function] Configure switchport storm control rate. storm-control-global rate <62-262144> [Parameter] <62-262144>: storm control rate, unit: kbit/s. [Parameter] 62 kbit/s [Command modes] Global configuration mode [Example] Configure switchport storm control rate to be 64 kbit/s: OPCOM3107(config)# storm-control-global rate 64 [Related commands] Commands show strom-control-global Description Show storm control configuration information.

2.7.5

show strom-control-global
[Function] Show storm control configuration information. show storm-control-global [Command modes] Global configuration mode [Example]
32

www.raisecom.com Show storm control configuration information: OPCOM3107(config)# show storm-control-global [Related commands] Commands strom-control-global Description Configure storm control function.

User Manual

2.7.6

vlan
[Function] This command is used to create vlan or enter static vlan mode, no command can be used to delete vlan. [no] vlan <2-4094> [Parameter] <2-4094>: vlan ID. [Default] Port 1 is access interface belonged to vlan 101; Port 2 is access interface belonged to vlan 102; Port 3 is access interface belonged to vlan 103; Port 4 is internal aggregation interface, belongs to trank allow vlan 1, 101, 102, 103 port by default. [Command modes] Global configuration mode, switchport mode, vlan mode [Example] Create vlan 15: OPCOM3107 (config)# vlan 15

2.7.7

state
[Function] Configure vlan working status. state (active | suspend) [Parameter] active: vlan enable; suspend: vlan disable. [Command modes] vlan mode
33

www.raisecom.com [Example] Enable vlan at this node: OPCOM3107 (config-vlan/2)# state active

User Manual

2.7.8

interface switchport
[Function] Enter switchport mode. interface switchport <1-4> [Parameter] <1-4>: switchport number [Command modes] Global configuration mode, switchport mode [Example] Enter switchport 1: OPCOM3107 (config)# interface switchport 1

2.7.9

switchport
[Function] Add assigned switchport to current vlan. The assigned port mode wont be changed. It change the port direct to vlan id if current port is in access or tunnel mode; It is allowed to add vlan in the vlan list if the port is in hybrid mode; if the display assigned vlan list in trunk mode, add the vlan to the list. switchport GLOBALPORTIDLIST No command can be used to delete assigned switchport from current vlan. The assigned port mode wont be changed. It change vlan id direct to global port id if current port is in access or tunnel mode; it deletes vlan from the allowed vlan list if the port is in hybrid mode; if the display assigned allowing vlan list in trunk mode, delete the vlan from the list. no switchport GLOBALPORTIDLIST [Parameter] GLOBALPORTIDLIST: switchport ID number, range from 1-4, use , and - when input several ports id. [Command modes] vlan mode [Executing Command Instruction] Configure switchport can also realize this function. Vlan configuration will be saved in form of switchport configuration.
34

www.raisecom.com [Example] Add switchport 5 to current vlan list: OPCOM3107 (config-vlan/12)# switchport 5

User Manual

2.7.10 switchport access vlan


[Function] Configure port mode to be access mode and assign vlan for the port. switchport access vlan <2-4094> [Parameter] <2-4094>: vlanID index. [Command modes] Switchport mode [Example] Configure port to be access port of vlan 15: OPCOM3107 (config-eswif/0/2)# switchport access vlan 15

2.7.11 switchport dot1q-tunnel vlan


[Function] Configure port mode to be tunnel mode and assign vlan for the port. switchport dot1q-tunnel vlan <2-4094> [Parameter] <2-4094>: vlanID index. [Command modes] Switchport mode [Example] Configure port to be tunnel port of vlan 15: OPCOM3107 (config-eswif/0/2)# switchport dot1q-tunnel vlan 15

2.7.12 switchport trunk allowed vlan list


[Function] Configure port mode to be trunk mode and assign vlan allowed by the port. switchport trunk allowed vlan list [Parameter]
35

www.raisecom.com list: vlanID list. [Command modes] Switchport mode [Example] Configure port to be trunk port permitting vlan 3, 4, 5: OPCOM3107 (config-eswif/0/4)# switchport trunk vlan 3-5

User Manual

2.7.13 switchport hybrid allowed vlan


[Function] Configure port mode to be hybrid mode and assign vlan allowed by the port. switchport hybrid allowed vlan list [Parameter] list: vlanID list, use , and - to separate several vlan. [Command modes] Switchport mode [Example] Configure port to be hybrid port permitting vlan 3, 4, 5: OPCOM3107 (config-eswif/0/2)# switchport hybrid allowed vlan 3-5

2.7.14 switchport mode


[Function] Configure port mode without change the port vlan id. switchport mode (access | dot1q-tunnel) [Parameter] access: access mode; dotlq-tunnel: tunnel mode. [Command modes] Switchport mode [Example] Configure port 2 to be access port: OPCOM3107 (config-eswif/0/2)# switchport mode access

2.7.15 switchport vlan


[Function]
36

www.raisecom.com Configure port vlan id without change port mode. switchport vlan <2-4094> [Parameter] <2-4094>: vlan id [Command modes] Switchport mode [Example] Configure vlan id of port 2 to be 24: OPCOM3107 (config-eswif/0/2)# switchport vlan 24

User Manual

2.7.16 show interface


[Function] Show interface configuration information. show interface [Command modes] Ethernet interface mode, Switchport mode, E1 interface mode [Example] Show configuration information of switchport 2: OPCOM3107 (config-eswif/0/2)# show interface

2.7.17 show esw


[Function] Show basic information of Eth-switch interface. show esw [Command modes] Privileged EXECmode, Global configuration mode [Example] Show basic information of Eth-switch interface: OPCOM3107 (config)# show esw

2.7.18 show interface switchport


[Function] Show information of assigned switchport. show interface switchport <1-4> [Parameter]
37

www.raisecom.com <1-4>: switchport index [Command modes] Global configuration mode, switchport mode [Example] Show information of switchport 4: OPCOM3107 (config-eswif/0/2)# show interface switchport 4

User Manual

2.7.19 show vlan


[Function] Show vlan configuration information. show vlan [<2-4094>] [Parameter] <2-4094>: vlan id [Command modes] Privileged EXEC mode, Global configuration mode, Static vlan mode, Switchport mode [Executing Command Instruction] Show all vlan information if no vlan ID was assigned. [Example] Show information of vlan 15: OPCOM3107 (config-eswif/2)# show vlan 15

2.7.20 qos
[Function] Configure qos function; no command can used to cancel qos. This function always aims at all ports. [no] qos [Default] No qos [Command modes] Global configuration mode [Executing Command Instruction] Cancel QOS function means using port priority configuration, and all ports priorities are 0 (the highest). [Example] Configure QOS function disable:
38

www.raisecom.com OPCOM3107 (config)# no qos

User Manual

2.7.21 qos default-cos


[Function] Configure default cos value for current switchport. qos default-cos <0-7> [Parameter] <0-7>: cos value [Default] 0 [Command modes] Switchport mode [Example] Configure cos value of switchport 1 to be 1: OPCOM3107 (config-eswif/1)# qos default-cos 1 [Related commands] Commands qos Description Qos function configuration.

2.7.22 qos trust cos


[Function] Enable QOS based on cos section in tag message, no command can be used to disable this function. [no] qos trust cos [Command modes] Global configuration mode [Example] Configure QOS function of COS enable: OPCOM3107 (config)# qos trust cos [Related commands] Commands qos show qos Description Qos function configuration. Show qos configuration information.

39

www.raisecom.com

User Manual

2.7.23 qos map cos-queue


[Function] Configure priority corresponding to COS value. qos map cos-queue cos0 cos1 cos2 cos3 cos4 cos5 cos6 cos7 [Parameter] cos0-7: COS value from 0-7 corresponding priority number, 0 means the highest priority. [Default] cos0 - cos1: 0 cos2 cos3: 1 cos4 cos5: 2 cos6 cos7: 3 [Command modes] Global configuration mode [Example] Configure QOS of COS to be cos0: 0, cos1: 1, cos2: 1, cos3: 1, cos4: 3, cos5: 3, cos6: 2, cos7: 2: OPCOM3107 (config-eswif/1)# qos map cos-queue 0 1 1 1 3 3 2 2 [Related commands] Commands qos show qos Description Qos function configuration. Show qos configuration information.

2.7.24 show qos


[Function] Show qos configuration information. show qos [Command modes] Global configuration mode [Example] Configure QOS confiugration information: OPCOM3107 (config-eswif/0/1)# show qos [Related commands] Commands qos show qos Description Qos function configuration. Show qos configuration information.

40

www.raisecom.com

User Manual

2.7.25 mac-address-table aging-time


[Function] Configure mac-address-table aging time. mac-address-table aging-time <0-3825> [Parameter] <0-3825>: aging time, unit : s. [Default] 300s [Command modes] Global configuration mode [Executing Command Instruction] System adopts hierarchical aging time, it will manual adopt 300, 75, 18, 1s automatically according to user configuration. [Example] Configure MAC address table aging time to be 75: OPCOM3107 (config)# mac-address-table aging-time 75 [Related commands] Commands mac-address-table learning mac-address-table static HHHH.HHHH.HHHH vlan vlan_id port <1-4> mac-polling show mac show mac-address-table ( all | static | dynamic ) [ port port-number | vlan vlan_id ] Description Configure mac learning function. Add table item of static mac address. Configure mac address polling function. Show mac address table configuration information. Show mac address table information.

2.7.26 no mac-address-table aging-time


[Function] Configure mac-address-table aging time to defaulted value. no mac-address-table aging-time [Default] 300s [Command modes] Global configuration mode [Example] Configure MAC address table aging time to default value:
41

www.raisecom.com OPCOM3107 (config)# no mac-address-table aging-time [Related commands] Commands mac-address-table learning mac-address-table static HHHH.HHHH.HHHH vlan vlan_id port <1-4> mac-polling show mac show mac-address-table ( all | static | dynamic ) [ port port-number | vlan vlan_id ] Description Configure mac learning function.

User Manual

Add table item of static mac address. Configure mac address polling function. Show mac address table configuration information. Show mac address table information.

2.7.27 mac-address-table learning


[Function] Configure mac-address learning function. mac-address-table learning (enable | disable) [Parameter] enable: MAC address learning enable ; disable: MAC address learning disable. [Default] enable [Command modes] Global configuration mode [Example] Disable MAC address learning function: OPCOM3107 (config)# mac-address-table learning disable [Related commands] Commands mac-address-table aging-time mac-address-table static HHHH.HHHH.HHHH vlan vlan_id port <0-5> mac-polling show mac show mac-address-table ( all | static | dynamic ) [ port port-number | vlan vlan_id ] Description Configure mac address table aging time. Add table item of static mac address. Configure mac address polling function. Show mac address table configuration information. Show mac address table information.

2.7.28 mac-address-table static HHHH.HHHH.HHHH vlan <2-4094> port <1-4>


[Function] Add static MAC address table, no command can used to delete static MAC address table.
42

www.raisecom.com

User Manual

[no] mac-address-table static HHHH.HHHH.HHHH vlan <2-4094> port <1-4> [Parameter] HHHH.HHHH.HHHH: MAC address ; <2-4094>: vlan ID; <1-4>: switchport number. [Default] No static MAC address [Command modes] Global configuration mode [Executing Command Instruction] Use mac-polling command to fulfill mac polling at first to get valid mac address information. [Example] Add MAC address 0001.2345.6789 to vlan ID 12, transferring port is 3: OPCOM3107 (config)# mac-address-table static 0001.2345.6789 vlan 12 port 3 [Related commands] Commands mac-address-table aging-time mac-address-table learning mac-polling show mac show mac-address-table ( all | static | dynamic ) [ port port-number | vlan vlan_id ] Description Configure mac address table aging time. Configure mac address table learning function. Configure mac address polling function. Show mac address table configuration information. Show mac address table information.

2.7.29 mac-polling
[Function] Enable MAC address polling, no command can used to disable this function. [no] mac-polling [Default] No mac-polling [Command modes] Global configuration mode [Example] Enable mac polling function: OPCOM3107 (config)# mac-polling [Related commands]
43

www.raisecom.com Commands mac-address-table learning Description

User Manual

Configure mac address learning function.

mac-address-table static HHHH.HHHH.HHHH Add table item of static mac address table. vlan vlan_id port <0-5> Show mac address table configuration information. show mac show mac-address-table ( all | static | dynamic ) [ port port-number | vlan vlan_id ] Show mac address table information.

2.7.30 clear mac-address-table


[Function] Clear table item in mac-address-table. clear mac-address-table (all|dynamic|static) [Parameter] all: all table items; dynamic: dynamic table items; static: static table items. [Command modes] Global configuration mode [Example] Clear all mac address table items: OPCOM3107 (config)# clear mac-address-table all Clear all static mac address table items: OPCOM3107 (config)# clear mac-address-table static Clear all dynamic mac address table items: OPCOM3107 (config)# clear mac-address-table dynamic [Related commands] Commands mac-address-table learning Description Configure mac learning function.

mac-address-table static Add static mac address table item. HHHH.HHHH.HHHH vlan vlan_id port <1-4> Show mac address table configuration information. show mac show mac-address-table ( all | static | dynamic ) [ port port-number | vlan vlan_id ] Show mac address table information.

2.7.31 search mac-address


[Function] Search mac-address in current mac address table.
44

www.raisecom.com search mac-address HHHH.HHHH.HHHH [Parameter] HHHH.HHHH.HHHH: MAC address. [Command modes] Global configuration mode [Example] Search table item 000e.5e01.0203 in mac address table: OPCOM3107 (config)# search mac-address 000e.5e01.0203 [Related commands] Commands mac-address-table learning Description

User Manual

Configure mac address learning function.

mac-address-table static Add static mac address table item. HHHH.HHHH.HHHH vlan vlan_id port <1-4> Show mac address table configuration information. show mac show mac-address-table ( all | static | dynamic ) [ port port-number | vlan vlan_id ] Show mac address table information.

2.7.32 show mac


[Function] Show mac address learning function and aging time configuration information. show mac [Command modes] Global configuration mode [Example] Show MAC address learning function and aging time configuration information: OPCOM3107 (config)# show mac [Related commands] Commands mac-address-table learning mac-address-table static HHHH.HHHH.HHHH vlan vlan_id port <1-4> mac-polling show mac-address-table ( all | static | dynamic ) [ port port-number | vlan vlan_id ] Description Configure mac address learning function. Add item of static mac address table. Configure mac address polling function. Show mac address table information.

45

www.raisecom.com

User Manual

2.8 Relevant command of clock


2.8.1 device clock local
[Function] Configure the internal clock source. There is no command to delete the clock source. device clock local priority <1-5> [quality (prc|ssua|ssub|sec|dnu| received)] no device clock local [Parameter] <1-5>: the priority of the clock (prc | ssu-a | ssu-b | sec | dnu | received): the clock quality levels. prc: reference clock in line with G.811 recommendations; ssua: SSU-A-level clock in line with G.812 recommendations; ssub: SSU-B-level clock in line with G.812 recommendations; sec: device clock in line with the G.813 recommendations; dnu: can not be used for synchronization; received: automatically extracted from the received signal.. [Default] Default to be dnu when quality level hasnt been configured. [Command modes] Global configuration mode [Executing Command Instruction] Quality level is configurable only when SSM enables. [Example] Configure the priority of the internal clock as 1 and quality level is taken to prc: OPCOM3107 (config)# device clock local priority 1 quality prc [Related commands] Commands show device clock Description Show device clock information.

2.8.2

device clock sdh-port


[Function] Configure sdh line clock source. There is no command to delete the clock source. device clock sdh-port <1-2> priority <1-5> [quality (prc|ssua|ssub|sec|dnu| received)] no device clock sdh-port <1-2> [Parameter] <1-2>: SDH port ID

<1-5>: the priority of the clock (prc | ssu-a | ssu-b | sec | dnu | received): the clock quality levels. prc: reference clock in line
46

www.raisecom.com

User Manual

with G.811 recommendations; ssua: SSU-A-level clock in line with G.812 recommendations; ssub: SSU-B-level clock in line with G.812 recommendations; sec: device clock in line with the G.813 recommendations; dnu: can not be used for synchronization; received: automatically extracted from the received signal.. [Default] Default to be dnu when quality level hasnt been configured. [Command modes] Global configuration mode [Executing Command Instruction] Quality level is configurable only when SSM enables. [Example] Configure the clock priority on sdh port 1 as 1 and quality level is taken to prc: OPCOM3107 (config)# device clock sdh-port 1 priority 1 quality prc [Related commands] Commands show device clock Description Show device clock information.

2.8.3

device clock e1
[Function] Configure E1 line clock source. There is no command to delete the clock source. device clock e1 <1-4> priority <1-5> [quality (prc|ssua|ssub|sec|dnu| received)] no device clock e1 <1-4> [Parameter] <1-4>: E1 port ID <1-5>: the priority of the clock (prc | ssu-a | ssu-b | sec | dnu | received): the clock quality levels. prc: reference clock in line with G.811 recommendations; ssua: SSU-A-level clock in line with G.812 recommendations; ssub: SSU-B-level clock in line with G.812 recommendations; sec: device clock in line with the G.813 recommendations; dnu: can not be used for synchronization; received: automatically extracted from the received signal.. [Default] Default to be dnu when quality level hasnt been configured. [Command modes] Global configuration mode [Executing Command Instruction] Quality level is configurable only when SSM enables.
47

www.raisecom.com [Example] Configure the clock priority on E1 port 1 as 1 and quality level is taken to prc: OPCOM3107 (config)# device clock e1 1 priority 1 quality prc [Related commands] Commands show device clock Description Show device clock information.

User Manual

2.8.4

device clock clear local


[Function] Clear the user commands in internal clock source, so that the clock source configured priority is to automatically switch. device clock clear local [Command modes] Global configuration mode [Example] Clear the user commands of the internal clock: OPCOM3107 (config)# device clock clear local [Related commands] Commands show device clock Description Show device clock information.

2.8.5

device clock clear sdh-port


[Function] Clear the user commands acts on line clock source to auto-switch the clock source that has been configured with priority. device clock clear sdh-port <1-2> [Parameter] <1-2>: SDH port ID [Command modes] Global configuration mode [Example] Clear the user commands of the sdh line clock 1: OPCOM3107 (config)# device clock clear sdh-port 1 [Related commands]
48

www.raisecom.com Commands show device clock Description Show device clock information.

User Manual

2.8.6

device clock clear e1


[Function] Force to switch the clock source to internal clock source. device clock clear e1 <1-4> [Parameter] <1-4>: E1 port ID [Command modes] Global configuration mode [Example] Clear the user commands of the E1 line clock 1: OPCOM3107 (config)# device clock clear e1 1 [Related commands] Commands show device clock Description Show device clock information.

2.8.7

device clock force-switch local


Function] Force to switch the clock source to internal clock source. device clock force-switch local [Command modes] Global configuration mode [Example] Force to switch to internal clock source: OPCOM3107 (config)# device clock force-switch local [Related commands] Commands show device clock device clock clear device clock mode Description Show device clock information. Clear the user commands Configure device clock mode

49

www.raisecom.com

User Manual

2.8.8

device clock force-switch sdh-port


[Function] Force to switch to sdh line clock source. device clock force-switch local sdh-port <1-2> [Parameter] <1-2>: SDH port ID [Command modes] Global configuration mode [Example] Force to switch to sdh line clock 2: OPCOM3107 (config)# device clock force-switch sdh-port 2 [Related commands] Commands show device clock device clock clear device clock mode Description Show device clock information. Clear the user commands Configure device clock mode

2.8.9

device clock force-switch e1


[Function] Force to switch clock source. device clock force-switch e1 <1-4> [Parameter] <1-4>: E1 port ID [Command modes] Global configuration mode [Example] Force to switch to e1 line clock 2: OPCOM3107 (config)# device clock force-switch e1 2 [Related commands] Commands show device clock device clock clear device clock mode Description Show device clock information. Clear the user commands Configure device clock mode

50

www.raisecom.com

User Manual

2.8.10 device clock lockout local


[Function] Clock source lockout command device clock lockout local [Default] No lockout. [Command modes] Global configuration mode [Executing Command Instruction] Use the clear command to cancel the clock source lock out. [Example] Lockout the internal clock: OPCOM3107 (config)# device clock lockout local [Related commands] Commands show device clock device clock clear Description Show device clock information. Clear the user commands

2.8.11 device clock lockout sdh-port


[Function] Clock source lockout command. device clock lockout sdh-port <1-2> [Parameter] <1-2>: SDH port ID [Default] No lockout. [Command modes] Global configuration mode [Executing Command Instruction] Use the clear command to cancel the clock source locked. [Example] Lock sdh line clock 1: OPCOM3107 (config)# device clock lockout sdh-port 1 [Related commands]
51

www.raisecom.com Commands show device clock device clock clear Description Show device clock information. Clear the user commands

User Manual

2.8.12 device clock lockout e1


[Function] Clock source lockout command device clock lockout e1 <1-4> [Parameter] <1-4>: e1 port ID. [Default] No lockout. [Command modes] Global configuration mode [Executing Command Instruction] Use the clear command to cancel the clock source locked. [Example] Lockout e1 line clock 2: OPCOM3107 (config)# device clock lockout e1 2 [Related commands] Commands show device clock device clock clear Description Show device clock information. Clear the user commands

2.8.13 device clock manual-switch local


[Function] Manually switch to clock source. device clock manual-switch local [Command modes] Global configuration mode [Example] Manually switch to internal clock: OPCOM3107 (config)# device clock manual-switch local [Related commands] Commands Description
52

www.raisecom.com show device clock device clock clear device clock mode Show device clock information. Clear the user commands Configure device clock mode

User Manual

2.8.14 device clock manual-switch sdh-port


[Function] Switch clock source manually device clock manual-switch sdh-port <1-2> [Parameter] <1-2>: sdh port ID [Command modes] Global configuration mode [Example] Manually switch to sdh line clock 2: OPCOM3107 (config)# device clock manual-switch sdh-port 2 [Related commands] Commands show device clock device clock clear device clock mode Description Show device clock information. Clear the user commands Configure device clock mode

2.8.15 device clock manual-switch e1


[Function] Switch clock source manually device clock manual-switch e1 <1-4> [Parameter] <1-4>: e1 port ID [Command modes] Global configuration mode [Example] Manually switch to e1 line clock 2: OPCOM3107 (config)# device clock manual-switch e1 2 [Related commands] Commands show device clock Description Show device clock information.
53

www.raisecom.com device clock clear device clock mode Clear the user commands Configure device clock mode

User Manual

2.8.16 device clock pll


[Function] Configure operating status of the device clock PLL. device clock pll (lock |freerun) [Parameter] (lock | freerun): PLL operating mode. lock : tracking mode; freerun : free-running mode (to switch to local oscillator for OPCOM3107). [Default] PLL is tracking mode by default. [Command modes] Global configuration mode [Example] Configure current device phase-locked loop in free-running mode: OPCOM3107 (config)# device clock pll freerun [Related commands] Commands show device clock mode Description Show device clock information.

2.8.17 device clock reset local


[Function] Restart clock source in an abnormal status. device clock reset local [Command modes] Global configuration mode [Example] Restart internal clock: OPCOM3107 (config)# device clock reset local [Related commands] Commands show device clock Description Show device clock information.

54

www.raisecom.com

User Manual

2.8.18 device clock reset sdh-port


[Function] Restart clock source in an abnormal status. device clock reset sdh-port <1-2> [Parameter] <1-2>: sdh port ID. [Command modes] Global configuration mode [Example] Restart sdh line clock 2: OPCOM3107 (config)# device clock reset sdh-port 2 [Related commands] Commands Show device clock Description Show device clock information.

2.8.19 device clock reset e1


[Function] Restart clock source in an abnormal status. device clock reset-switch e1<1-2> [Parameter] <1-4>: e1 port ID. [Command modes] Global configuration mode [Example] Restart e1 line clock 2: OPCOM3107 (config)# device clock reset e1 2 [Related commands] Commands Show device clock Description Show device clock information.

2.8.20 device clock wait-to-restore-time


[Function] Configure wait-to-restore-time device clock wait-to-restore-time <0-12>
55

www.raisecom.com [Parameter]

User Manual

<0-12>: a high-priority clock recovery, clock switching latency from low-priority to high-priority clock, recording on minutes, 0 indicated no wait. [Default] 5 min [Command modes] Global configuration mode [Example] Configure wait-to-restore-time as 0: OPCOM3107 (config)# device clock restore-time 0 [Related commands] Commands device clock show device clock Description Configure external and internal clock source Show device clock information.

2.8.21 device clock ssm


[Function] Configure device clock SSM function device clock ssm (standard|extend|disable) [Parameter] (standard | extend | disable): SSM function enabled option. standard: enable the standard SSM functions; diasble: dsiable SSM function, extend: enable SSM expansion function. [Default] diasble [Command modes] Global configuration mode [Example] Enable SSM functions: OPCOM3107 (config)# device clock ssm standard [Related commands] Commands device clock show device clock Description Configure external and internal clock source Show device clock information.

56

www.raisecom.com

User Manual

2.8.22 device clock local id


[Function] Configure clock source ID device clock local id <0-15> [Parameter] <0-15>: ID [Command modes] Global configuration mode [Example] Configure inner clock ID as 8: OPCOM3107 (config)# device clock local id 8 [Related commands] Commands show device clock Description Show device clock information.

2.8.23 device clock sdh-port id


[Function] Configure clock source ID device clock sdh-port <1-2> id <0-15> [Parameter] <1-2>: sdh port ID <0-15>: ID [Command modes] Global configuration mode [Example] Configure sdh line clock 1 ID as 8: OPCOM3107 (config)# device clock sdh-port 1 id 8 [Related commands] Commands show device clock Description Show device clock information.

2.8.24 device clock e1 id


[Function] Configure clock source ID
57

www.raisecom.com device clock e1 <1-4> id <0-15> [Parameter] <1-4>: e1 port ID <0-15>: ID [Command modes] Global configuration mode [Example] Configure e1 line clock 1 ID as 8: OPCOM3107 (config)# device clock e1 1 id 8 [Related commands] Commands Show device clock Description Show device clock information.

User Manual

2.8.25 show device clock


[Function] Configure device clock information show device clock [Command modes] Privileged EXECmode; Global configuration mode [Example] Show clock information: OPCOM3107# show device clock [Related commands] Commands device clock mode device clock manual-switch device clock sdh-port 1 priority 1 Description Configure clock mode. Configure manual-switch clock source Configure clock prority

2.9 System Configuration Command Line


2.9.1 dcc select
[Function] Choose DCC channel type dcc select (d1d2d3|e1channel) [Parameter]
58

www.raisecom.com

User Manual

d1d2d3: using SDH overhead bytes d1d2d3to transmission network management information. e1channel: use e1 channel to transmit network management information. [Default] Use overhead bytes d1d2d3to transmission network management information. [Command modes] Global configuration mode [Executing Command Instruction] Choosing e1 channel to transmit network management information will also be required to configure corresponding e1 channel timeslot, E1 port transmitting network management information, regularlly use 9-10 port, 9: network management channel corresponding to east-bound optical interface, 10: network management channel corresponding to west-bound optical interface. [Example] Use overhead bytes d1d2d3to transmission network management information: OPCOM3107 (config)# dcc select d1d2d3 [Related commands] Commands Show info Description Show current device information.

2.9.2

e1-retiming-src
[Function] Choose E1 retiming source. e1-retiming-src (osc|e1-1|e1-2|e1-3|e1-4) [Parameter] osc: use the local clock. e1-1: use the e1 port 1 receiving clock as the re-timing source. e1-2: use the e1 port 2 receiving clock as the re-timing source. e1-3: use the e1 port 3 receiving clock as the re-timing source. e1-4: use the e1 port 4 receiving clock as the re-timing source. [Default] Use local lock as the re-timing source. [Command modes] Global configuration mode [Example] Choose E1 port 1 receiving clock as the re-timing source: OPCOM3107 (config)# e1-retiming-src e1-1 [Related commands]
59

www.raisecom.com Commands Show info Description Show current device information.

User Manual

2.9.3

e1 <1-8> retiming
[Function] Choose E1 port whether enable retiming function. e1 <1-8> retiming (enable|disable) [Parameter] <1-8>: choose E1 port (enable|disable): whether to enable E1retiming function [Default] Disable retiming function of E1 on all port. [Command modes] Global configuration mode [Example] Enable retiming function of E1 port 1: OPCOM3107 (config)# e1 1 retiming enable [Related commands] Commands show info Description Show current device information.

2.9.4

show info
[Function] Show device system information show info [Command modes] Privileged EXEC mode ; Global configuration mode [Explanation of command execution echo] device type: OPCOM3107-8E1-BL
current sdh port 1 lpr status: normal current sdh port 2 lpr status: normal select e1 retiming source: osc current e1 retiming source: osc e1-1 retiming enable: disable e1-2 retiming enable: disable 60

www.raisecom.com
e1-3 retiming enable: disable e1-4 retiming enable: disable DCC Select: E1 Channel

User Manual

[Example] Show clock information: OPCOM3107# show device clock

2.9.5

show shelf
[Function] Show chassis status show shelf [Command modes] Privileged EXEC mode; Global configuration mode [Explanation of command execution echo]
Device OPCOM3107 Name: OPCOM3107-Raisecom Technology Co., Ltd. Description: Serial no: Asset ID: Lock status: Unlock Temperature threshould: 50

Shelf 1 exist Name: Description: Vendor: Serial no: Asset ID: Raisecom Technology Co., Ltd. OPCOM3107 Shelf 1

Power 1 exist Power 2 not exist

Fan 1 not exist Fan 2 not exist

[Example] Show clock information: OPCOM3107# show device clock


61

www.raisecom.com

User Manual

Chapter 3 Reference Materials

chinese clear config device unlock device lock device clock-mode disable enable english end exit help interface history hostname list logout quit reboot settime show clock show cpu-utilization-ratio show device show device clock show sntp show terminal show version sntp server sntp broadcast client terminal history terminal line terminal time-out who device assetid device description

All modes All modes Privileged mode Privileged mode Global mode Global mode Privileged mode Common mode All modes Global mode, interface mode All modes All modes Global mode All modes Privileged mode All modes Privileged mode All modes Privileged mode Privileged mode Privileged mode Privileged mode Privileged mode, Global mode Privileged mode Privileged mode Privileged mode Privileged mode Global mode Global mode Common mode Common mode Common mode Privileged mode Global mode Global mode
62

www.raisecom.com show opt-device Privileged mode, Global mode

User Manual

password show user user user privilege save user

Privileged mode Privileged mode Privileged mode Privileged mode Privileged mode

log log clear show log

Global mode Global mode Privileged mode, Global mode

arp add arp delete ip address ip route ping show arp show ip route show snmp-server community show snmp trap-server snmp-server community snmp-server contact SYSCONTACT snmp-server location SYSLOCATION snmp-server name SYSNAME snmp trap-server snmpd show snmp-server statistics show interface snmp

Global mode Global mode Snmp interface mode Global mode Privileged mode, Global mode Privileged mode, Global mode Privileged mode, Global mode Privileged mode, Global mode Privileged mode, Global mode Global mode Global mode

Global mode Global mode Global mode Global mode Privileged mode, Global mode Privileged mode, Global mode

download erase startup-config show running-config show startup-config upload write

Privileged mode Privileged mode Privileged mode Privileged mode Privileged mode Privileged mode

63

www.raisecom.com alarm-trap-disable alarm-trap-disable index port-trap-disable show current-alarm show history-alarm show alarmindex show alarmindex index show port-trap-disable Global mode Global mode Global mode Privileged mode, Global mode Privileged mode, Global mode Privileged mode, Global mode Privileged mode, Global mode Privileged mode, Global mode

User Manual

interface eth autonegotiate description shutdown show interface speed duplex auto-mdix flow-control reset statistic

Global mode, eth interface mode eth interface mode eth interface mode eth interface mode Privileged mode, eth interface mode eth interface mode eth interface mode eth interface mode eth interface mode eth interface mode

interface vcg show vcg encapsulation gfp-fcs reset statistic

Global mode Privileged mode, vcg configuration mode vcg configuration mode vcg configuration mode vcg configuration mode

description interface sdh j0mode loopback sdh es-threshold sdh exc-threshold sdh ais-insert sdh reset-statistics sdh overhead c2 sdh overhead j0 sdh overhead j1

Interface configuration mode Global mode, sdh interface mode Interface configuration mode Interface configuration mode Interface configuration mode Interface configuration mode Interface configuration mode debug Interface configuration mode Interface configuration mode Interface configuration mode
64

www.raisecom.com sdh overhead s1 sdh sd-threshold sdh ses-threshold sdh aupje-threshold show interface sdh Interface configuration mode Interface configuration mode Interface configuration mode Interface configuration mode Privileged mode, interface mode

User Manual

interface dcc shutdown ip unnumbered ip address echo-time echo retry times auto-connect show interface dcc

Global mode, dcc interface mode Interface configuration mode Interface configuration mode Interface configuration mode Interface configuration mode Interface configuration mode Interface configuration mode Privileged mode, interface mode

65

www.raisecom.com

User Manual

Appendix A Acronyms
Table 1: Acronyms ADM AIS APS AU AU-n AUG AU-PTR BBE BBER BER CMI C-n CORBA CV DCC DCE DCF DCN DDN DTE DXC ECC EM Table 2: Acronyms
EML EMS EOS ES ESR ETSI FEBBE FEES

Full spelling Add-Drop Multiplexer Alarm Indication Signal Automatic Protection Switching Administrative Unit Administration Unit,level n Administration Unit Group Administration Unit Pointer Background Block Error Background Block Error Ratio Bit Error Ratio Coded Mark Inversion Container- n Common Object Request Broker Architecture Code Violation Data Communications Channel Data Circuit-terminating Equipment Data Communications Function Data Communications Network Digital Data Network Data Terminal Equipment Digital Cross Connect Embedded Control Channel Element Management

Full spelling
Element Management Layer Element Management System Ethernet Over SDH Error Second Error Second Ratio European Telecommunication Standards Institute Far End Background Block Error Far End Error Second

66

www.raisecom.com
FESES GUI HDLC HPC IP ITU-T L2 LAN LCT LOF LOP LOS LPC MAC MAN MCU MD MF MII MM MS Far End Severely Error Second Graphical User Interface High Digital Link Control Higher order Path Connection Internet Protocol International Telecommunication Union-Telecommunication Standardization Sector Layer 2 Local Area Network Local Craft Terminal Loss Of Frame Loss Of Pointer Loss Of Signal Lower order Path Connection Medium Access Control Metropolitan Area Network Micro Control Unit Mediation Device Mediation Function Medium Independent Interface Multi Mode Multiplex Section

User Manual

67

Address: 2nd Floor, South Building of Rainbow Plaza, No.11 Shangdi Information Road, Haidian District, Beijing Postcode: 100085 Tel: +86-10-82883305 Fax: +86-10-82883056 Email: export@raisecom.com http://www.raisecom.com

S-ar putea să vă placă și