5 kV Class
GENERATOR CIRCUIT BREAKER TYPES: VCP-WG (DRAWOUT DO) / VCP-WRG (FIXED FIX)

Maximum Voltage (V): 5 kV


Short Circuit Current (Isc)

50 kA

Frame (see Figures 7 and 8)

29"

29"

31"

31"

63 kA
29"

29"

31"

31"

75 kA
31"

DO

FIX

DO

FIX

DO

FIX

DO

FIX

31"

Ratings Assigned

Units

DO

FIX

Continuous Current

A rms

1200
2000
3000
40001

1200
2000
3000
40001 4000

50001

4000
5000
6000
63001
70001

1200
2000
3000
40001

1200
2000
3000
40001

4000
50001

4000
5000
6000
63001
70001

1200
2000
3000
4000
50001

1200
2000
3000
4000
5000
6000
63001
70001

kV rms
kV peak
ms
ms
kA rms
% DC
ms
kA rms
s
kA peak
kA rms
% DC
kA rms
% DC
kV / s
kV peak
s
operations
operations
kA
kV rms

19
60
50
47
50
75
30
50
3
137
25
130

3.0
9.2
3.1
10,000
10,000
25
6.1

19
60
50
47
50
75
30
50
3
137
25
130

3.0
9.2
3.1
10,000
10,000
25
6.1

19
60
83
47
50
75
54
50
2.3
137
25
130
31.5
110
3.0
9.2
3.1
10,000
10,000
25
6.1

19
60
83
47
50
75
54
50
2.3
137
25
130
31.5
110
3.0
9.2
3.1
10,000
10,000
25
6.1

19
60
50
47
63
75
30
63
3
173
31.5
130
40
110
3.0
9.2
3.1
10,000
10,000
31.5
6.1

19
60
50
47
63
75
30
63
3
173
31.5
130
40
110
3.0
9.2
3.1
10,000
10,000
31.5
6.1

19
60
83
47
63
75
54
63
1.4
173
31.5
130
40
110
3.0
9.2
3.1
10,000
10,000
31.5
6.1

19
60
83
47
63
75
54
63
1.4
173
31.5
130
40
110
3.0
9.2
3.1
10,000
10,000
31.5
6.1

19
60
83
47
75
63
54
75
1
206
40
130
50
110
3.02
9.22
3.12
10,000
10,000
37.5
6.1

19
60
83
47
75
63
54
75
1
206
40
130
50
110
3.02
9.22
3.12
10,000
10,000
37.5
6.1

kV / s

3.3

3.3

3.3

3.3

3.3

3.3

3.3

3.3

3.3

3.3

kV peak
s

13
13
4.5
4.5
5 kV, 3 kA

Dielectric Strength

Power frequency withstand voltage


Lightning impulse withstand voltage
Interrupting Time
Closing Time
Short-Circuit Current

Asymmetrical current interrupting capability


Ref: Minimum opening time
Short-time current carrying capability
Duration of short-time current
Closing and Latching Capability
First Generator-Source Symmetrical Current Interrupting Capability
First Generator-Source Asymmetrical Current Interrupting Capability
Second Generator-Source Symmetrical Current Interrupting Capability
Second Generator-Source Asymmetrical Current Interrupting Capability
Prospective TRV Rate of Rise of Recovery Voltage (RRRV)

Transient recovery voltage Peak (E2 = 1.84 x V)


Transient recovery voltage Time to Peak (T2 = 0.62 x V)
Load Current Switching Endurance Capability
No-Load Mechanical Endurance Capability
Out-of-Phase Current Switching Capability

90 out-of-phase power frequency recovery voltage


( = 1.5 x sqrt(2/3) x V)
90 out-of-phase inherent TRV
Rate of Rise of Recovery Voltage (RRRV)
Transient recovery voltage Peak (E2 = 2.6 x V)
Transient recovery voltage Time to Peak (T2 = 0.89 x V)
Enclosure = VCP-W

13
13
4.5
4.5
5 kV, 4 kA

Notes:
Rated frequency: 60 Hz
Standard operating duty: CO - 30 m - CO
Relevant Standard: IEEE standards C37.013-1997 and C37.013a-2007
Test certificates available
1 Ratings achieved using forced air cooling by blowers in the enclosure.
2 TRV capacitors are required if RRRV>0.5 kV/s; or T2<65 s.

EATON CORPORATION Medium Voltage Generator Vacuum Circuit Breakers www.eaton.com

13
13
4.5
4.5
5 kV, 3 kA

13
13
4.5
4.5
5 kV, 4 kA

13
13
4.5
4.5
5 kV, 4 kA