Sunteți pe pagina 1din 3

Glandless Pumps

Standard 3-Speed Pumps (max. 2800 r.p.m.)


Wilo-ClassicStar
[m] 8

Duty Graph Gesamtkennfeld Wilo-ClassicStar


6

Sta

r- R S

25/

4
Sta r- R S

6, S t a r-

RS

30/

25/

4, S ta

r- R S

30/

2
S ta rRS 2 5/2, S ta r-

Wilo-Star RS
Single head pumps Screwed-end pump
0 0 0 0,5

RS 3 0/2

1 0,25

1,5 0,5

2 0,75

[m 3/h] [l/s]

Identification Code
e.g.: RS 25/ 6 Wilo-Star-RS 25/6 Screwed-end pump Connection size Rated shut-off head [m]

Scope of Supply
Pump incl. 2 union washers, packing and O&M manual

Pump Equipment
Screwed end single head pump Manual 3-speed control Non-overloading single phase motor Optional left or right cable entry Special design versions Wilo-Star RS 25/4 and RS 25/6 Bronze body, 180 mm port-to-port Cast iron body 130 mm port-to-port

Fields of Application
Central heating installations Industrial circulating systems Air conditioning and chilled water circulation systems

Accessories
Union connector fittings, thermal insulation

Mounting Positions
Pump shaft in the horizontal plane, terminal box optionally 3, 6, 9 or 12 oclock

Technical Data
SuitableFluids
Heating water to VDI 2035 Water/glycol mixtures, max. mixing ratio 1:1. Hydraulic corrections required for mixing ratio above 20% Performance Speed range 1100-2200 r.p.m. Manual 3-speed control Fluid temperature range -10C to +110C Max.working pressure 10 bar Ambient Temperature permissible up to 40C Electrical Wiring Mains power 1 ~ 230 V, 50 Hz Motor Degree of protection IP 42 Insulation class F Interference emission: EN 50081-1 Interference resistance: EN 50082-2 Construction Materials Pump body Impeller Shaft Bearings cast iron GF-PP stainless steel graphite

RS 25/2

RS 25/4

RS 25/6

RS 30/2

RS 30/4 114"

Pumpendaten
Screwed connection size/DN Max. working pressure 10 bar

1" b b 50 C 95 C 110 C 0.5 3 10

Permissible fluid temperature (water): 10 C to + 110 C Minimum inlet pressure (m) at the pump suction inlet to avoid cavitation noise at + 40 C ambient and water temperatures max:
Standard design Sonderausfhrung (auf Anfrage)

E.& O.E. Subject to change without prior notice

Wilo-Star-RS

RS 30/6 69

Wilo-Star-RS

Glandless Pumps
Standard 3-Speed Pumps (max. 2800 r.p.m.)
Wilo-Star-RS 25/2, RS 30/2, RS 25/4, RS 30/4 Duty graph Single Phase
3 0 0 0,25 0,25 0,5 v 0,75 0,5 1,0 0,75 1,25 Rp1 [m/s] Rp114

Duty graph Single Phase


5 0 0 0,5 0,5 1,0 v 1,5 1,0 Rp1 [m/s] Rp114

Wilo-Star-RS 25/2 Wilo-Star-RS 30/2


1~ 230 VRp1/Rp1 1"/11/41" 4 1~ 230 V
4

Wilo-Star-RS 25/4 Wilo-Star-RS 30/4


1" 1 230 ~ 230 1"/11/4 1~ V V Rp1/Rp1 4

2 3
m

H [m]

ma

H [m]

ax

1
ec

ec

0 0 0 0 60 0,5 0,1 2 0,2 1,0 0,3 4 Q


max

0 1,5 0,4 6 2,0 0,5 0,6 8 2,5 0,7 [m 3/h] [l/s] [lgpm] 80 0 0 0 1,0 0,25 5 Q
max

2,0 0,5 0,75 10

3,0 1,0

[m 3/h] [l/s] [lgpm]

40 P1 [W] P1 [W]

60

eco

20

40
eco

0 0 0,5 1 1,5 2 2,5 [m 3/h]

20 0 1,0 2,0 3,0 [m 3/h]

Pump Diagram
b1 b3 G

Wiring Diagram
Single phase motor 1 ~ 230 V/ 50 Hz

PG 11 l3 b4 l4

l0

b2

l1

With integrated capacitor

Measurements Weights
Wilo-Star-RS RS RS RS RS 25/2 30/2 25/4 30/4 Rp G I0 l1 l3 l4 mm 1" 114" 1" 114" 112"M 2"M 112"M 2"M 180 180 180 180 97 97 97 97 90 90 90 90 79 79 79 79 33 33 33 33 100 100 100 100 92.5 92.5 92.5 92.5 54 54 54 54 73 73 73 73 a b1 b2 b3 b4 Weight ca. kg PN 10 2.4 2.6 2.4 2.6

Motor data
Single phase motor (EM) 2pole 1 ~ 230 V, 50 Hz
Wilo-Star-RS
Rated power Steps/Speed P2 max. dn W 1/r.p.m. Power input P1 W Current I A Capacito Motor Protectio r F/VCR

Motor data
Single phase motor (EM) 2pole 1 ~ 230 V, 50 Hz
Wilo-Star-RS
Rated power Steps/Speed P2 max. dn W 1/r.p.m. Power input P1 W Current I A Capacito Motor Protectio r F/VCR

RS 25/2 RS 30/2

9 4 2

max eco

1900 1600 1100

46 - 49 30 - 34 19 - 21

0.21 0.15 0.09

1.6/400

1)

RS 25/4 RS 30/4

22 13 7

max eco

2000 1650 1200

56 - 68 40 - 48 27 - 32

0.28 0.20 0.13

2.0/400

1)

1) Non-overloading motor - No external overload control required.

Always refer to name plate data!

70

Wilo-Star-RS

E.& O.E. Subject to change without prior notice

Glandless Pumps
Standard 3-Speed Pumps (max. 2800 r.p.m.)
Wilo-Star-RS 25/6, Wilo-Star-RS 30/6 Duty graph Single Phase
6 0 0 0,5 0,5 1,0 v 1,5 1,0 Rp1 [m/s] Rp114

Wilo-Star-RS 25/6 Wilo-Star-RS 30/6


1" 1 230 ~ 230 1"/11/4 1~ V V Rp1/Rp1 4

ax

H [m]

2
ec o

0 0 0 0 120 1,0 0,25 5 Q 0,5 2,0 0,75 10 3,0 1,0 [m 3/h] [l/s] [lgpm]

100 P1 [W]

max

80

60
eco

40 0 1,0 2,0 3,0 [m 3/h]

Pump Diagram
b1 b3 G

Wiring Diagram
Single phase motor 1 ~ 230 V/ 50 Hz

PG 11 l3 b4 l4

l0

b2

l1

With integrated capacitor

Measurements Weights
Wilo-Star-RS RS 25/6 RS 30/6 Rp G I0 l1 l3 l4 mm 1" 114" 112" 2" 180 180 97 97 90 90 79 79 33 33 100 100 92.5 92.5 54 54 76 76 a b1 b2 b3 b4 Weight ca. kg PN 10 2.4 2.6

Motor data
Single phase motor (EM) 2pole 1 ~ 230 V, 50 Hz
Wilo-Star-RS
Rated power Steps/Speed P2 max. dn W 1/r.p.m. Power input P1 W Current I A Capacito Motor Protectio r F/VCR

RS 25/6 RS 30/6

37 22 12

max eco

2200 1900 1200

77 - 99 56 - 75 41 - 50

0.41 0.31 0.24

2.6/400

1)

1) Non-overloading motor - No external overload control required. Always refer to name plate data!

E.& O.E. Subject to change without prior notice

Wilo-Star-RS

71

S-ar putea să vă placă și