Canon Singapore Pte Ltd Medical Equipment Products Division Prepared by: Yuki 2013 March
FirstCanonBrandedOCTislaunched!
2. AppealPoints
21.3m depthresolution 22.70,000Ascan/sec 23.10mmscanwidth 24.Just2clicksforacquiringtomography 25.Autotrucking 26.Followupexams 27.Autoalignment/Autofocus/AutoCgate 28.FlyingspotSLO 29.8typesofscanmodes 210.Noisereductionbyaveragingupto50images 211.10layerboundaryrecognition 212.Vitreous/Choroid mode 213.Versatilereports 214.Flexiblelayout 215.Retinalcameraimageimport 216.Anteriorsegmentadapter 217.Normativedatabase 218.InstallationImage 219.Specification 220.ProductComponents&Options 221.ComparisonchartwithCompetitorsproducts
Speedy
Highqualityimage
21.3mDepthresolution
Highimagequalityisarchivedbym Depth resolution.
AMD AMD
22. 70,000Ascan/sec
by70,000 Ascan/sec.
Highspeedscan&Highimagequalityisrealized
23.10mmScanWidth
DC Averaging(50/50)
24.
Just2clicksforacquiringtomography
Start
25.Autotrucking
Autotruckingfunctionensuretheexactcapturing image
AnteriorChamberAutoTrucking: Autodetectedpositionascenterofthepupilor designatedpositionby usercouldbetruckedasthecenterofscanarea. RetinalAutoTruckingWhiledisplayingretinalliveviewimage,Scanareais truckedautomaticallybycalculatedcenterpositionsmovingdistance.
Anterior AutoTrucking
ON/OFFselectablerespectively 2sizesofinternalfixationlightisselectable
2mm
RetinalAutoTrucking
6mm
26.FollowupExam
RetinalAutoTruckingfunctionenableuserstocapture samepointwithpastexaminationdata.Difference:lessthan100m Whenanexaminationisselectedinthepatientscreenorwhencapture screenisopenedfromthereportscreen,followupexamsetis automaticallyselected.
Thefollowingitemsshouldbesetto sameconditionsasaprevious examination. RightorLefteye ScanMode ScanPosition ScanSize(width,distance) NumberofAveraging AutomaticorManualMode InternalorExternalFixationTarget InternalFixationTargetSize InternalFixationTargetPosition CGateorientation
Capturedpointisregistered.
27.AutoAlignment/Autofocus/AutoCgate
Variousauto functionsmakeexaminationseasy&short.
AutoCgate AutoFocus
28.FlyingSpot SLO
Retinal image Preview (H44 V33)
Live image (No delay) High resolution For disease High resolution For blood vessel Simple mechanism
fsSLO hasbetterresolutionthanLSLOandcanobtain bettercontrastimages. (Nidek andHeidelberg adoptsfsSLOaswell.) LSLOisbetterinquickscanbutnotsomuch differenceasfsSLOthesedays (Zeiss adoptsLSLO.)
29.8 typesofscanmodes
Scan Mode Scan Direction Horizontal Fixation Target Macula C-Gate Orientation Vitreous or Choroid Scan Size Description Macula 3D 10x10mm For macula analysis of macula disease. This mode supports to change C-Gate orientation for choroidal disease (AMD) and other macula disease. For macula analysis of glaucoma. This mode has a vertical scanning direction for symmetrical diagnostic. For disc analysis of glaucoma. Volume scan,12 axis by 15 degrees extracted. For general usage. This mode does not support analysis reports for specific disease. For multi purpose Averaging: 5, 10 B-scans For high image quality Averaging: 5, 10, 20, 50 B-scans For anterior imaging For anterior imaging Averaging: 5, 10, 20, 50 B-scans
Glaucoma 3D
Vertical
Macula
Vitreous
10x10mm
Disc 3D
Horizontal
Disc
Vitreous
6x6mm
Custom 3D
Horizontal or Vertical Horizontal and Vertical Horizontal and Vertical Horizontal Horizontal and Vertical
Multi Cross
Cross
210.Noisereductionbyaveragingupto50images
HighqualityimagesareprovidedbyMAX50images averagingfunction.
1image
10images
20 images
50 images
210.Noisereductionbyaveragingupto50images
M210DC vs RS-3000Nidek
Canon HS-100 DC averaging(50/50) NIDEK RS-3000 averaging(7/10)
211. 10layerboundaryrecognition
OCTHS100softwarecanrecognizeboundaryof Bruchsmembrane(BM).
Recognize10boundaries
ILM RNFL/GCL GCL/IPL IPL/INL OPL/ONL OPL/ONL IS/OS OS/RPE RPE/Choroid BM
15
Choroid is shown deeper than usual in under gate. Choroid Choroid Mode Mode (EDI) (EDI) Availablewhenyouchoose: Macula3D,MultiCross Custum 3D,Cross
213. Versatilereports
Easytochangethereporttype
View Mode Single Both Eyes Comparison Progression General 3D A standard analysis report for a single examination. A report for comparison of right and left eyes. OCT-HS100 software search examination of another side eye automatically. A report for comparison of 2 examinations. OCT-HS100 software search suitable examination automatically. A report for confirmation of disease progress. OCT-HS100 software search suitable examinations automatically. Advanced visualization for single 3D examination. 3D visualization for single 3D examination.
Single
Both eyes
Comparison
Progression
General
3D
17
213. Versatilereports
Easytomakereportsformaculadiseaseorglaucoma
Scan mode Macula 3D Glaucoma 3D Disc 3D Custom 3D Multi Cross Cross
Macula analysis for macula disease Scan Scan modeMacula 3D
Report type Macula analysis for macula disease Macula analysis for glaucoma Disc analysis for glaucoma. General 3D report General 2D report General 2D report
Macula analysis for glaucoma Scan modeGlaucoma 3D Disc analysis for glaucoma Scan modeDisc 3D
Focusonthethicknessofcornea
FocusonthethicknessofNFL+GCL+IPL
214.Flexiblelayout
Inspectorandpatientcanbepositionedflexibly.
Supporting communicationbetween Inspectorandpatients Savingspaceand increasingefficiencyfor usersworkflow Competitors layout
Sided layout
45 degree layout
L mark layout
215.RetinalCameraImageImport
CaptureFundusimage,possibleto display(oroverlay)insteadofthe SLOimage
ImportJPEG orBMP retinalcameraimages Softwaretrimstheretinal imagesinaformatof4:3. SLOimageisoverlaidonto theretinalcameraimage automaticallyormanually sothattheposition matches. Transparencycanbe adjustedfortheoverlay.
216. Anteriorsegmentadapter
Byattachingananterioradapter(optional),itspossible totakeOCTimageoftheanterioroftheeye
217. NormativeDatabase
Normativedatabasewillbesupportedinthenextversionof software. TBI
Normativedatabasewillworkwiththefollowingitems:
Macular 3D Deviation Map Significance Map Thickness Sector Thickness Profile Thickness Time-line Graph Thickness Measurement Table Glaucoma D NFL+GCL+IPL Deviation Map NFL+GCL+IPL Significance Map NFL+GCL+IPL Sector NFL+GCL+IPL Thickness Profile NFL+GCL+IPL Time-line Graph NFL+GCL+IPL Measurement Time-line Table Disk D RNFL Deviation Map RNFL Significance Map RNFL Thickness Sector ONH Measurement Table RNFL Thickness Profile RFNL Thickness Time-line Graph ONH Measurement Time-line Table
White base display when normative database is not applicable No database display when normative database is not applicable Sample of reports when normative database is not applicable
218.InstallationImage
23
219.BasicSpecifications
Retinal observationCapture Scan speed Cross lateral direction resolving power Depth resolving power OCT wavelength The smallest pupil diameterfor Working distance Method Range of observation 3D Macula for Macula scan pattern Disease 3D Macula for Glaucoma 3D Disc for Glaucoma 3D Custom for Advance Max 70,000 A-scan per second 20um 3.0um 855nm5nm 3.0mm 35mm flying spot SLO 3333OCT / 4433SLO 1024Ascan x 12810x10mm, Horizontal, Vitreous or Choroid 1024Ascan x 12810x10mm, Vertical, Vitreous 512Ascan x 2566x6mm, Horizontal, Vitreous default : 1024Ascan x 128 9x9mm, Horizontal, Vitreous, Macula X and Y range : 3-9mm(adjustable independently) C-Gate : Vitreous or Choroid Fixation Target : Macula or Disc default : 1536Ascan X and Y range : 3-9mm(adjustable independently) averaging : 1-10 C-Gate : Vitreous or Choroid Fixation Target : Macula or Disc default : 1536Ascan X and Y range : 3-9mm(adjustable independently) averaging : 1-50 C-Gate : Vitreous or Choroid Fixation Target : Macula or Disc Default is 2mm"X"at fundus Orange590nm 387x499x474 29kg
Cross B-scan
220.Productcomponents&Options
Basiccomposition OCTHS100MainUnit ACPowercordset Objectivelenscap Externaleyefixationlamp sameasCR2 ChinrestPaper(100sheets) DustCover Synchronouscable DVDR(CanonOCTSoftware) FixingpartsforCameralinkcable CableTie FerriteCore UserManuals(Mainunit,OCTSoftware) Standardaccessory Cameralinkboard PCIe1433 2Cameralinkcables Option AnteriorAdapter ForeheadPadforAnteriorAdapter ChinRestforAnteriorAdapter AnteriorAdaptermainunit Storagecase