H1 Axial piston pump Size 089/100 single pump Features Designed for quality and reliability One design concept Single piece swash plate Installation and packaging benefits Length optimized pump Minimum one clean side Higher corner power Higher package size ratio Standardized connector interface Expanded functionality through PLUS+1 Optimized for electrical control Electro-hydraulic control options include Electrical Displacement Control (EDC) Forward-Neutral-Reverse (FNR) and Non-Feedback Proportional Electric (NFPE) Common control across entire family Expanded functionality PLUS+1 Compliant control and sensor options Integral ltration available with integrated lter bypass sensors and switch Greater total eciency Minimized control losses Improved charge circuit Lower control pressure for less power consumption
Local Address:
Schematic
M14 M6 1 R2 C2 C1 M3 L2 F00B F00A MA A M5 CW B S L4 MB
P003 417
R1
Operating parameters
Minimum 500 Input min-1 Rated 3300 speed (rpm) Maximum 3800 Maximum working 450 [6525] 420 [6090] pressure* System bar [psi] pressure Maximum pressure 480 [6960] 450 [6525] Minimum low loop 10 [150] Rated 3.0 [40] Case bar [psi] pressure Maximum 5.0 [75] * Applied pressures above maximum working pressure T000 167E requires Sauer-Danfoss application approval.
M4
Dimensions
Servo gage port M4 Port ISO 11926-1 7/16 -20 21 max. clearance dia for tting System port B 25.4 - 250 bar Split ange boss per ISO 6162 M12x1.75 20 [0.79] min full thread depth Charge inlet port S Port ISO 11926-1 1 5/8 -12 69 max. clearance dia for tting
Y
295.33 2.0 [11.627 0.079]
Connector: Deutsch DT04-2P to be paint free Case pressure port Port ISO 11926-1 1 1/16 -12 48 max. clearance dia 112.39 1.0 for tting [4.425 0.039]
View X
System port A 25.4 - 250 bar Split ange boss per ISO 6162 M12x1.75 20 [0.79] min full thread depth
Case drain port L4 Port ISO 11926-1 1 1/16 -12 48 max. clearance dia for tting Case pressure port Port ISO 11926-1 1 1/16 -12 48 max. clearance dia for tting
CCW Rotation
CW Rotation
View Z
Charge ltration port E Port ISO 11926-1 7/8 -14 42 max clearance dia for tting from lter
SAE C 221.15 1.0 [8.707 0.039] All other 212.65 1.0 [8.372 0.039]
SAE C 135.765 1.0 [5.345 0.039] All other 127.265 1.0 [5.010 0.039]
View Y
Servo gage port M5 Port ISO 11926-1 7/16 -20 21 max. clearance dia for tting Charge pressure port Port ISO 11926-1 5/16 -24
Charge ltration port F Port ISO 11926-1 7/8 -14 42 max clearance dia for tting to lter
Case gage port M14 Port ISO 11926-1 7/16 -20 except spot face depth: 5 max. 21 max. clearance dia for tting System B gage port MB Port ISO 11926-1 9/16 -18 28 max. clearance dia for tting
Charge gage port M3 Port ISO 11926-1 9/16 -18 28 max. clearance dia Case drain port L2 for tting after ltering Port ISO 11926-1 1 1/16 -12 48 max. clearance dia for tting Charge gage port M6 Port ISO 11926-1 9/16 -18 28 max. clearance dia for tting before ltering
71.4 1.0 [2.812 0.0391] 285.6 1.0 [11.244 0.0391] 294.4 1.0 [11.591 0.0391]