Sunteți pe pagina 1din 1

min. 2.

80

40

60 HRC Elevation ................. 70 70

Front Elevation
Details of CSM Tower See Drawing No. 20D con 70

Section A-A
15 Bulldog Grips 16 25 40

10 WC Elevation. ................. Tower Foundation 150 150

or 20D con 106

10 12 13 11

Erection Hook 3 Stirrups 10 each Anchor Rods 25 Inner Drum Outer Drum each cable end to be wound once around the drum and clamped with second cable

65

100

300

Hard Rock Tower Foundation


Inner Drum first stage concrete Erection Hook

Typical Cross Section of RCC Drum


RCC diameter of Drum 20

Form work for Drum is done with a bamboo mat (Chitra) lined with a plastic sheet.Use binding wire around the drum for fixing.
14 Bulldog Grips

Handrail Cable Walkway Cable Outer Drum second stage concrete

Plan View

Double Drum

20

3 Stirrups 10 Walkway Cable Handrail Cable

for each Drum

Hard Rock

Anchor Rods Ribbed Tor steel 25mm drill holes as shown in table volume per hole = 0.002m3
diameter of rod holes

65 Dimension of Drums and Quantity of Anchor Rods :

100 Standard Quantities

Anchore Rods to be grouted in cement mortar 1:1

Cable [mm]

arrangement of anchor rods

Stirrups 10 mm outer drum for inner drum for Total Required handrail cable walkway cable Volume Anchor RCC for Rods RCC for of cutting bending weight Drum rod holes Drum rod holes Drum 25 mm nos length dia kg/pc [cm] [cm] [mm] [mm] [kg] [nos] [cm] [cm] [m3] 3 3 3370 5250
for inner drum

required diameters of:

Cement Type of construction [m3] [bags]


Chisel dressed Stone Masonry 1:4 Hammer dressed Stone Masonry 1:6 Hammer dressed Dry Masonry Concrete 1:2:4
*(Volume of Drums x6.40)

Scale 1 : 50
All Dimensions are in Centimeter
Related Steel Drawing is : 60D2

See drawing no. 20Dcon 70 or 20Dcon106 6.99 2.02 * 0.50 5.42 2.20 10.50

HMG / Ministry of Local Development


DoLIDAR / Short SpanTrail Bridge Standard
Bridge Name No Bank : Span

Hand Rail 26 Walkway 26 160 145 100 85 1.10 16

880

2.08

for outer drum

1480

3.24

Nos & spacing of Bulldog Grips Spacing Cable Nos [cm] mm

Construction Drawing:

or
Hand Rail 26 Walkway 32 180 165 125 110 1.30 20 3 3

for inner drum

RCC Double Drum Anchor in Hard Rock Type 1HRD


2 Walkway Cables 26 or 32 mm
Date : Nov. 05, 2001

4150 5880

1130 1680

2.56 3.63

for outer drum

Concrete 1:3:6 Broken stones

13 26 32

3 5 6

10 15 20

........... 46

Drawing No. 63D con

Produced by

Nepal

Swiss Association for International Cooperation, in partnership with His Majestys Government of Nepal, funded and supported by the Swiss Government (SDC Nepal).