Chroma Lightline Ligthline Installation Document

As the pioneer of translucent materials, 3form understands how light inspires, captivates and transforms design. Introducing 3form Lightline designed specifically to work with Chroma panels. Lightline brings a new dimension to lighting translucent materials. Lightline is fully integrated light solution with hidden technology that deliverers over 50.000 hours of fully tested lighting - Fit and forget 3form Lightline.

Chroma Lightline Installation Document Parts overview


LIGHTLINE MODULES Illsutration 1 - Lightline module Delivered already mounted into the Chroma panel Aluminium extrusion T1 cold cathode fluorescent lamp Mounted together with a ballast 3 Exit way versions CCT: 4000 Kelvin Color rendering: Ra > 80 Input voltage 24 Volt DC 1,2 V Unit contains high voltages Class 2 luminaire Electrical supply requires SELV approval IEC 60529 IP40 POWER SUPPLY Illsutration 2 - Power Supply Input voltage 100-240V AC 50/60Hz Class 2 Power supply On the mains side standard EU connector 45-60-100-150 Watt Maximum load of 63% Plug and play 250mm cable on mains side, 500mm cable on the Lightline side NECTOR S CONNECTION SYSTEM Illsutration 3 - Nector S connection system Nector S T Splitter Nector S Distributor Nector S Extention cables (0.5m- 2m)

For more information please visit www.3form.eu or email info@3form.eu or call +31 (0) 88 336 76 00 19-05-11 3form BV, All rights reserved

Chroma Lightline Installation Document


Illsutration 4 - lightline details

Illsutration 5 - Exit way details

For more information please visit www.3form.eu or email info@3form.eu or call +31 (0) 88 336 76 00 19-05-11 3form BV, All rights reserved

Chroma Lightline Installation Document


Illsutration 6 - Lightline label 1 with explanation

Illsutration 7 - Lightline label 2 with explanation

Lightline modules, power supplies and extension cables


Below table describes the correlation between the lightline modules, extension cables and power supplies. Table 4 - Overview Maxiumum amount of extension cables 3 2 3 3 3 3 1 3 3 3 3 Maxiumum module length and quanity maximum (1) x1600mm maximum (2) x800mm maximum (1) x2100mm maximum (2) x900mm maximum (1) x3000mm maximum (2) x1800mm maximum (3) x1000mm maximum (1) x3000mm maximum (2) x2700mm maximum (3) x1800mm maximum (6) x900mm

Power supply 45Watt 60Watt

100Watt

150Watt

For more information please visit www.3form.eu or email info@3form.eu or call +31 (0) 88 336 76 00 19-05-11 3form BV, All rights reserved

Chroma Lightline Installation Document Manual


PRIOR TO INSTALLATION Read this manual before use, incorrect use could damage the product. Check if the delivery is complete and undamaged. Should the delivery be incomplete or damaged, please contact your supplier. Do not in any circumstances use damaged or incomplete products. Any work on or associated with Lightline should be carried out by suitably qualified personal. Lightline should be assembled and used in accordance with local national regulations. Lightline is a technical product and should be treated as a class 2 lighting luminaire. LIGTHLINE MODULE Cables cannot be lead through the Lightline modules. The lamp, electronics and housing are balanced in the factory and are not user modifiable. Cables or other parts may not be modified, lamps cannot be replaced. There are no user serviceable parts, modules. POWER SUPPLY Power supply do not require earthing. Power supply requires 100-240Volt. Power supplies are applied with mains cable tail for connection to the main circuit. Electrical supply requires SELV approval. Power packs used in closed environment may suffer reduced lifetime. ENVIROMENTAL PARAMETERS Lightline units comply with IEC 60529, protection class IP40. Avoid water / moisture in and on the Lightline. Ta maximum 50C and minimum 10 C. No chilling of the Lightline modules. NO COLD AIR, ISOLATE FROM COLD SURFACE. Mounting directly onto metal is not allowed. Lightline is only suitable for interior applications and can be installed in normal flammable materials. ASSEMBLY Locate the power pak in a suitable location. Connect the power pack to the Lightline with the connector cables using the Nector S plugs and sockets. Connect the mains supply to the power pack. In case of malfunction disconnect the mains supply.

General remarks
In case of any technical problem, disconnect power supply and consult the supplier. Unauthorised changes or modifications will invalidate the warranty. Replacement of the lamp is not possible. Avoid water / moisture in and on the Lightline. Lightline contains Mercury and Fluorescent powder which can damage the environment, it must be disposed of responsibly at end of life in accordance with local regulations. For more information please contact 3form Product Managment.