Chilled beams
Create a stable and comfortable environment by supplying draught free temperature control 75% of total cooling capacity handled by water Available with heating and cooling Low noise
Continuous improvement R&D focussed on reducing energy consumption Optimisation of Air Handling units to meet customer requirements
Chillers
Designed to minimise overall energy consumption Free cooling chillers significantly reduce energy consumption especially with chilled beam systems Provide reduced investment and running costs
To address the requirements of the EPBD directive, Flkt Woods has poured a lot of effort into creating the e3 Concept. Our solution is a broad approach leaving no stone unturned to achieve optimum results. High-performing components provide a good start, but it is by combining products into an integrated system, utilising smart control, that one can achieve the best energy solutions. The e3 logo is used to highlight products and systems that deliver savings on Energy, Economy and the Environment.
Controls
Wide range of integrated control solutions available Factory mounted & pre-wired Pre-programmed & factory tested control applications Open standard communication protocols for integration into BMS
Flexible, comfortable and energy efcient climate for the modern ofce
In these more energy and indoor air quality conscious days, chilled beam systems have come the fore. Predominantly due to the energy benets over alternative systems such as fan coil units, the chilled beam system also provides an incredibly stable environment which adds to the occupants wellbeing and satisfaction. Flkt Woods have now moved this on a stage with the introduction of our new iQ Star range of chilled beams. These beams not only give you the indoor air quality but due to the addition of smart controls, the Stella and Astra are able to provide variable airow rates. This means that demand control ventilation has been added to an already energy efcient system providing the end user with additional energy savings. That, coupled with our ow pattern control and energy (comfort) control, leads to these beams offering you full exibility to adapt to any future changes in room layout.
PL
3
The now dehumidied and cooled air continues to the sensible rotor, where heat from exhaust air is recovered and used to re-heat it. The air is supplied to the building, with controlled levels of both temperature and humidity. Note that the temperature exchange in the sensible rotor, where exhaust air is cooled, further improves the cooling recovery of exhaust air in the hygroscopic rotor!
1
When outdoor air is warmer than the exhaust airow there is a need for cooling. The hygroscopic rotor then reduces temperature of the incoming air. Simultaneously it transfers moisture from the inbound to the outbound air ows (in cases where absolute humidity is higher outdoors)
2
After passing through the hygroscopic rotor the air passes through the cooling coil, where the temperature is reduced further and moisture is condensated down to required levels. Since the air has already been cooled by the hygroscopic rotor, the demand for cooling is lowered. The saving can be up to 50% of the nominal required cooling effect, while at the same time the need for a following re-heating battery in most cases disappears.
5.0 m3/s
Exhaust air
Energy control
The new flexible nozzle arrangement guarantees high indoor air quality and energy efficiency. A quiet solution even when high air flow is needed.
Accessories
Flexibility is increased by the numerous accessories available for iQ Star. Not only is Stella available with any equipment you need, you also have the opportunity to customise its design.
27.3 11.3
Hygroscopic rotor
16.1 9.5
Sensible rotor
23.0 9.5
Extract
Extract air
Stella
Outdoor air
Supply air
Life cycle
AIR HANDLING UNIT EU 9490 () / Fisher University ACON-00664444 4 (CBSW ) / AHU SW ACB 64
AIR HANDLING UNIT EU 2.1.100903.1 9490 () / Fisher University ACON-00664435 2010-09-06 2 (CBTW ) / AHU TW ACB 64 Page 4
As we understand, chilled beam systems create high quality indoor environments which are incredibly energy efcient. But because of the nature of the chilled beam system, it is possible for us to use more energy efcient components as part of the complete system. On the following pages you will see both our Twin Wheel Air Handling Units and our Free Cooling Chillers. Both of these components can offer signicant savings and can only be utilised to their full extent because of the nature of the chilled beam system.
LCC diagram
ANNUAL ENERGY DEMAND NORMAL OPERATION
LCC diagram
ANNUAL ENERGY DEMAND NORMAL OPERATION
Laboratory tested
The Twin Wheel system has been tested in our laboratory under dened and accurately measured conditions.
20 10 0
System Fan Coil Units AHU - Air Handling Unit with Single Thermal Wheel Standard 6/12 Chiller System Chilled Beams AHU - Air Handling Unit with Single Thermal Wheel Standard 6/12 Chiller System Fan Coil Units 2W - Twin Wheel Standard 6/12 Chiller System Chilled Beams 2W - Twin Wheel Standard 6/12 Chiller System Chilled Beams AHU - Air Handling Unit with Single Thermal Wheel Free Cooling Chiller Option(75% FC Chiller, 25% 6/12 Chiller) System Chilled Beams 2W - Twin Wheel Air Handling Unit Free Cooling Chiller Option (75% FC Chiller, 25% 6/12 Chiller)
Product Mix
The chart above shows energy comparisons between Chilled Beam and Fan Coil Unit systems with different options of AHU and Chiller. The Fan Coil Unit system does not have the free cooling option as they operate on lower chilled water temperatures. As you can see an energy reduction of approx 50% can be achieved by utilising a Chilled Beam System with Twin Wheel AHU and free Cooling System option.
Feb Mar Apr May Jun Jul Aug
3 4
Sep
Oct
Nov
Dec
4 3
Saving Based on 425kW Chiller running 60hrs/week 14/17C Saving = 160957 kWh 12233 per annum Free Cooling option 13500 - payback = 13 months Saving 68 tonnes of CO2 emmissions p/a = 160957 kWh 12233
On
11
Note: Chiller completely paid off in 4 years 4 months. Total energy saving of 244,660 in 20 years (0.076/kWh). Real saving = 191,160 for 11 the chiller or 231,160 for the cost of the free cooling element of the chiller. Total saving of 1360 tonnes of CO2 over 20 years (based on UK carbon outputs of 0.422 kg/kWh). Total CO2 without free cooling would be 3900 tonnes over 20 years.
5 5
FACTS ABOUT GREENWICH PENINSULA Peninsula Central is a 3.5 million sq ft business district at the heart of the Greenwich Peninsula redevelopment One of the largest chilled beam contracts in the London area The building (14 Pier Walk) has officially been awarded a BREEAM Excellent rating with a score of 71% and an Energy Performance Certificate band B with a score of 37
How it works
off
4 3
On
off
11
When the outside air temperature is lower than the temperature of the water 8 7 returning from the systems, it is convenient to take advantage of this cold source which is totally free. 6 On
10
11
off
8
off
The water returning from the system will be cooled in part or totally in the heat exchanger coils (additional to the standard condenser). While the outside air temperature falls, the cooling capacity recovered in theUnit Free-Cooling Side coils increases in inverse proportion up to a point that allows the 100% production of chilled 1 water2using only outside air and with System side completely idle compressors.
(1) Solution inlet from the system (2) Chilled solution outlet to the system (3) Free-cooling coil (version Free-Cooling only) (4) Condenser coil (5) Compressors (6) Evaporator (7) Circulation pump (8) 3 way pump (version Free-Cooling only) (9) Fans (10) Expansion valves (11) Outside air temperature Working refrigerant ciruit
Further references
Unilever, Kingston, UK Manchester Metropolitan University, UK Fitzrovia, London, UK M W Kellog, London, UK 227 Tottenham Court Road, London, UK Bidborough House, London, UK John Dalton Building, Manchester, UK
On
10
(1) Solution inlet from the system (2) Chilled solution outlet to the system (3) Free-cooling coil (version Free-Cooling only)