Noise Levels
Flakt Woods offer acoustic analysis and attenuators to ensure the fans are In accordance with environmental requirements and local regulations.
Applications
Longitudinal ventilation of road tunnels Emergency ventilation - smoke control Mine ventilation Hangar/large area ventilation
Ventilation
Ventilation is required for safety and to maintain acceptable temperatures and comfort. Pollution emitted by road vehicles must be removed to provide an acceptable and safe environment. In the case of a fire, smoke must be removed in order to enable safe escape and to assist access to fight the fire. The normal ventilation principles are to dilute pollution and to increase visibility by removal of particles. In an emergency the smoke is controlled by creating sufficient air velocity to drive it away from the fire. Depending on the control strategy, the smoke can then be extracted.
Fan Selector
Fan Selector is the selection software for all the Flkt Woods Fan Group products: Axial Flow Fans (among which Jet Fans for Tunnels), Centrifugal fans, Boxed Fans, Roof Extract units, Plate mounted fans. The Fan Selector allows you to choose fans which fit your required application.
Fan Codes
3. Once you have entered your details, just click the Register button at the bottom of the registration page to submit your request.
Desktop CD
Should you prefer to use the Desktop version of the software (which is locally installed onto your computers hard drive), then this is available on request. All you need to do is to advise your full postal address and we would be happy to mail a CD to you.
Link to the On-Line Fan Selector: http://fanselector.flaktwoods. com 1. After logging in, the first screen displayed allows the selection of axial fans, identify and click select to continue. 2. The next screen displays the various types of axial fans, therefore it is necessary to filter the selection by clicking product filter and edit. 3. The desired thrust can be input to identify suitable fans. Other filters can be adjusted so the desired fan is identified. 4. Each fan can be highlighted and technical information made available
2000
Thrust (N)
Thrust (N)
71 4 80 4 90 4 100 6 112 6 125 6 140 6 160 8 160 6
1500
1000
Options:
Option of a silencer with or without acoustic pod Mounting frame to ensure secure installation Epoxy paint
300/2 - Range
0
71 4 80 4 100 6 112 6 125 6 140 8 160 8
Thrust (N)
Thrust (N)
2000
1000 500 0
63 2 71 4 71 2 80 4 90 4 100 6 100 4 112 6 112 4 125 6 125 4 140 6 140 4 160 8 160 6
0
56 2 63 2 71 4 71 2 80 4 80 2 90 4 100 6 100 4 112 6 112 4 125 6 125 4 140 8 140 6 160 8 160 6
Thrust (N)
Thrust (N)
Options:
Epoxy paint on top of galvanised finish Bolt-on Silencers Accessories
400/2 - Range
400/2 Unidirectional 50Hz
3000 3000
2500
2500
Thrust (N)
Thrust (N)
2000
2000
1500
1500
1000
1000
500
500
0 0
71 4 80 4 90 4 100 6 100 4 112 6 112 4 125 6 125 4 140 6 160 8 160 6 56 2 63 2 71 4 71 2 80 4 90 4 100 6 100 4 112 6 112 4 125 6 125 4 140 8 140 6 160 8 160 6
2000
Thrust (N)
71 4 80 4 90 4 100 6 112 6 125 6 140 6 160 8 160 6
1500
1000
500
0
71 4 80 4 100 6 112 6 125 6 140 8 160 8
200 for 200C for 2 hours 300 for 300C for 1 hour 400 for 400C for 2 hours
rust (N)
4000
rust (N)
2000 1500
2000
Fan type
Blade angle
Thrust N
Nominal Current A
Fan type
Blade angle
Thrust N
Nominal Current A
20 24 29 32 36 22 25 28 34 27 32 36 40 26 31 38 40 21 27 31 34 37 40 20 24 28 33 26 33 37 40 20 25 31
324 419 529 592 672 575 672 772 943 289 355 408 457 661 819 1038 1088 878 1176 1378 1532 1687 1826 1289 1665 2021 2438 1141 1500 1710 1868 1253 1606 2087
29.4 33.5 37.6 39.8 42.4 34.8 37.6 40.3 44.6 21.9 24.3 26 27.5 26.5 29.5 33.2 34 27.2 31.5 34.1 36 37.8 39.3 29.6 33.6 37 40.7 24.9 28.5 30.4 31.8 22.8 25.8 29.4
9.2 12.6 17.6 21.1 26.1 17.8 21.6 26.5 38.9 4.62 6.4 8.2 9.8 12.7 17.7 26.4 28.7 16.7 26.8 34.8 41.6 49 56.9 33.9 46.7 61.2 82.4 21.8 34.5 42.8 49.8 24.7 34.6 51.6
11.04 12.65 18 22.2 27 18 22.2 27 40 4.8 6.6 8.63 11.04 13.2 18 27 33 17.3 27 36 42.55 49.5 63.3 34.5 49.5 63.3 86.3 22.2 36 44.4 51.8 26.4 36 51.8
20.2 23.3 32.6 40.4 49.8 32.6 40.4 49.8 74.6 9.2 12.6 16.3 21 25.4 35 49.8 65 33.1 49.8 67 77.7 94.8 110 63.8 94.8 110 154 42.7 66.2 79.9 92.3 49.7 66.2 92.3
104 106 97 98 99 100 101 101 103 87 89 91 93 97 99 101 102 92 95 96 98 99 100 99 100 101 103 95 98 100 101 98 99 101
2 56JMTS 2 2 2 2 2 63JMTS 2 2 2 2 2 2 71JMTS 2 2 2 4 80JMTS 4 4 4 4 90JMTS 4 4 4 100JMTS 4 4 4 4 4 112JMTS 4 4 4 4 4 125JMTS 4 4 4 4 6 140JMTS 6 6 6 6 160JMTS 6 6 6
22 30 35 40 20 24 28 32 37 40 20 24 28 33 35 30 35 40 44 35 40 43 29 34 39 44 30 33 37 41 44 25 28 31 33 36 40 32 36 40 43 23 27 30 40
133 211 260 304 177 229 290 354 425 466 320 415 516 660 698 259 324 374 395 534 617 648 566 704 896 1011 1023 1180 1356 1495 1551 1074 1300 1546 1715 1960 2251 1186 1393 1555 1631 1234 1571 1856 2555
21.2 26.7 29.7 32.1 21.8 24.8 27.8 30.8 33.7 35.3 25.9 29.5 32.9 37.3 38.3 20.7 23.2 24.9 25.6 26.4 28.4 29.1 24.5 27.3 30.8 32.8 29.4 31.6 33.9 35.6 36.2 27 29.7 32.4 34.1 36.5 39.1 25.3 27.5 29 29.7 22.6 25.5 27.7 32.5
3.3 6.4 8.8 12.2 4.4 6.5 8.8 11.9 17.2 20.7 8.1 12.1 17.4 26.3 30.9 4.6 6.6 8.9 10.8 12.4 17 19.6 12.1 17.1 26.1 31.1 25.4 32 42.6 53.7 61.2 26.4 33.9 43.9 52.1 65.7 83.6 25.7 34.4 44.1 50.9 25.3 34.7 43.3 84.5
3.6 6.6 9 12.65 4.6 6.6 9 12.65 18 22.2 8.25 12.65 18 27 33 4.8 6.6 9 11.04 13.2 17.3 20.35 13.2 17.3 27 33 27 33 44.4 54 63.3 27 34.5 44.4 54 66 86.3 26.4 36 44.4 51.8 26.4 36 44.4 86.3
6.93 12.3 16.4 23.3 9.3 12.3 16.4 23.3 32.6 40.4 15.5 23.3 32.6 49.8 58.8 9.2 12.6 17 21 25.4 33.1 39.5 25.4 33.1 49.8 65 49.8 65 79.3 95.1 110 49.8 63.8 79.3 95.1 115 154 49.7 66.2 79.9 92.3 49.7 66.2 79.9 155
94 95 97 101 93 95 96 98 99 100 100 100 101 103 104 90 92 94 95 90 92 93 100 101 104 106 97 98 100 102 103 101 102 104 104 105 107 99 100 102 103 100 101 101 105
Fan type
Blade angle
Thrust N
Nominal Current A
Fan type
Blade angle
Thrust N
Nominal Current A
23 30 35 40 25 30 35 40 25 29 34 20 25 31 37 20 25 31 34 39 26 32 39 20 27 29 32 21 24
222 307 368 427 378 472 568 640 526 644 806 744 1012 1312 1586 1237 1606 2039 2207 2580 974 1256 1565 1266 1796 1950 2184 1967 2284
21.6 25.4 27.8 30 25 28 30.7 32.6 26.3 29 32.5 28.1 32.8 37.3 41 32.3 36.9 41.5 43.2 46.7 25.7 29.2 32.6 26.2 31.2 32.5 34.4 28.6 30.8
4.1 6.6 9 11.5 6.8 9.6 13.1 16.7 13.3 18.1 25.9 18 26.7 39.1 53.9 27.4 41.7 62.6 74.8 97.5 19.4 28.9 42.2 24.3 42.7 48.8 58.9 47.5 58
4.32 6.93 9.78 12.1 6.93 9.78 13.8 19.6 13.8 19.6 28.8 19.6 28.8 39.6 58.3 28.8 43.2 63.6 75.6 97.8 20.4 30 43.2 25.2 43.2 50.4 61 50.4 61
7.61 12.9 16.3 20.2 12.9 16.3 22.3 32.8 22.3 32.8 46.9 32.8 46.9 66.3 96.7 46.9 68.8 97 115 150 32 50 68.1 41.6 68.1 79.3 94.9 79.3 94.9
98 99 101 105 91 93 95 97 89 91 93 101 102 104 106 96 98 101 102 104 95 98 100 97 100 101 102 103 104
71JMTS
80JMTS
90JMTS
112 JMTS
125JMTS
140JMTS
160JMTS
4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6
30 33 36 25 32 37 44 27 30 33 39 44 28 31 35 37 40 28 31 34 40 44 26 30 35 22 24 26
207 239 271 285 419 508 564 489 578 667 818 885 1241 1438 1693 1813 1980 936 1083 1227 1466 1544 1293 1627 2034 1736 1957 2209
20.9 22.4 23.9 21.7 26.4 29 30.6 25.3 27.5 29.6 32.7 34.1 32.4 34.9 37.8 39.2 40.9 25.2 27.1 28.9 31.6 32.4 26.5 29.7 33.2 26.8 28.5 30.3
4.3 5.5 6.9 5.6 9.4 13.1 19 11.8 14.9 18.9 28.4 36 40.2 49.4 63.2 71.7 87.8 19.4 24.2 29.6 41.8 50 29.2 40.2 58.8 41.5 49.4 57.8
4.32 5.76 7.56 5.76 9.78 13.8 19.6 12.1 15 19.6 28.8 39.6 41.4 50.4 63.6 72.5 97.8 20.4 25.2 30 43.2 50.4 30 43.2 61 43.2 50.4 61
7.61 9.75 12.7 9.75 16.3 22.3 32.8 20.2 25.6 32.8 46.9 66.3 65.6 77.9 97 110 150 32 41.6 50 68.1 79.3 50 68.1 94.9 68.1 79.3 94.9
90 91 93 93 94 97 99 91 92 94 96 98 107 108 109 110 112 97 98 100 102 103 101 102 104 104 105 105
10
HT Certification
Emergency, High Temperature, Smoke Extract Fans fall within the scope of the EU Construction Products Directive. The implementation of the Construction Products Directive and the publication of the product specific standard, EN 12101-3 have made it a mandatory requirement for smoke control fans sold into the European Union to carry a CE Mark from April 1st, 2005. The CE mark may only be affixed after successful completion of testing, auditing of factory production control and the issue of a certificate by accredited independent authorities. This procedure is intended to prevent fan failures during an emergency smoke situation, where a fan failure can ultimately lead to the loss of life. Flkt Woods fully endorse the concept that, in such a safety critical application, only fully verified and certified products should be specified. This made the decision to test and certify this core product range all the more easier. The decision was made to embark on a major testing programme in conjunction with BSRIA, a leading authority in building research. Using the expertise of Flkt Woods and BSRIAs new state of the art High Temperature test rig, the Jet Fan range was successfully tested in compliance with this demanding new legislation with minimum complications. This investment resulted in Flkt Woods being able to offer a British Standards Institution Certified, CE marked Jet Fan product for use at 400C/2 hours from 560mm to 1600mm, together with a comprehensive range of approved accessories. Flkt Woods have enhanced their position as the foremost provider of specialist products for emergency high temperature smoke control by becoming the first fan manufacturer in the world to be able to apply CE marking to these safety critical products. CE marking was then obtained from BSI for the JM HT fan range for additional 200C and 300C temperature categories, ensuring that Flkt Woods has one of the most comprehensive range of products available in the Single European Market.
Other Accessories
Acoustic pod
Mounting feet
Guards
Bellmouth Inlet
Outline Drawings
It is recommended that a Flkt Woods frame accompany the jet fan to ensure a secure installation. Anti-vibration mounts are available for soft mounting installations.
200 for 200C for 2 hours 300 for 300C for 1 hour
11
12
Outline Drawings
Max 3.3 D
D 1.2 D
D 1.2 D
Rail/Metro Country Australia Austria Austria Austria Austria Austria Austria Austria Austria Austria Austria Brazil Canada Canada Canada Canada China Denmark Dubai Greece Greece Greece Hong Kong Hong Kong Hong Kong Hong Kong Hong kong Hungary Hungary India India India India India Iran Italy Italy Italy Italy Italy Italy Italy Italy Italy
Max 5.2D
Project Parramatta Rail Link U3 Station Erdberg U2/1 Schottenring River City U1 Unterwerk U2 Messe U4 Schottenring Vienna Metro - Gross Vienna Metro - Leoup Obb wien mitte U4 schotatenring Sao Paulo Metro Line 4 TTC Shepherd TTC Petrofit TTC York Mills Montreal STCUM Guangzhou Metro Copenhagen Metro Dubai Light Railway Attiko Metro - Elliniko Ext. Egnatio Odos Driscos Tunnel Attiko Metro, Athens TKO South Hong Kong Beacon Hill Tunnel Lok Ma Chau Pennys Bay Line Mtr/tsy station Budapest Metro Line 2 Budapest Metro Line 4 Delhi Metro Phase II Delhi Metro DMRC Phase 1 (Mc1b) Damel Dwarka Sector 21 East Mashhad Metro Passante Ferroviario Di Torino Torino Di Bologna Nodo Di Bologna Passante Ferroviario Turin Metro Turin Metro Lot 6c Project Rome Rail Station Avigliana Alifana Metro
13
14
Flkt Woods is a global leader in air management. We specialise in the design and manufacture of a wide range of air climate and air movement solutions. And our collective experience is unrivalled. Our constant aim is to provide systems that precisely deliver required function and performance, as well as maximise energy efficiency.
Solutions for all your air climate and air movement needs
Flkt Woods is providing solutions for ventilation and air climate for buildings as well as fan solutions for Industry and Infrastructure. Air Handling Units (AHUs) Modular, compact and small AHU units. Designed to ensure optimisation of indoor air quality, operational performance and service life. Air Terminal Devices and Ducts Supply and exhaust diffusers and valves for installation on walls, ceiling or floor are all included in our large range and fit all types of applications. Chilled Beams Active induction beams for ventilation, cooling and heating, and passive convection beams for cooling. For suspended or flush-mounted ceiling installation and multi-service configuration. With unique Comfort Control and Flow Pattern Control features. Residential ventilation A complete range of products for residential ventilation. Consists of ventilation units, exhaust air fans and cooker hoods designed to optimise indoor comfort and save energy. Energy recovery Dessicant-based product and systems that recover energy, increase ventilation and control humidity. Fans Advanced axial, centrifugal and boxed fans for general and specialist applications. Comprehensive range including high temperature and ATEX compliant options. Engineered for energy efficiency and minimised life cycle cost. Chillers Air-cooled and water-cooled chillers with cooling capacity up to 1800kW. Designed to minimise annual energy consumption in all types of buildings. Controls and drives Variable speed drives and control systems, all tested to ensure total compatibility with our products. Specialist team can advise on energy saving and overall system integration. Acoustical Products A complete line of sound attenuating products, including rectangular and round silencers, Media Free silencers, custom silencers and acoustic enclosure panels.
Flkt Woods operates a policy of continuous development and improvement. Accordingly, the Company reserves the right to supply products that may differ from those illustrated and described in this publication. Certified dimensions will be supplied on request on receipt of order.
FWGJRG/JFB-06/0912