Documente Academic
Documente Profesional
Documente Cultură
maxonDC
RE-max
motor
M 1:1
Stock program
Standard program
Special program (on request)
Article Numbers
215998 215999 269569 216000 216001 216002 216003 216004 216005 216006 216007
Motor Data
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
9
12
15
11400 11300 11500
37
27.5
22.3
8290 8220 8340
3.85 3.86 3.83
0.556 0.415 0.333
14.4
14.4
14.3
1.95
1.45
1.17
74
74
74
24
11800
14.4
8680
3.81
0.214
14.7
0.771
75
24
10500
12.6
7320
3.83
0.191
12.9
0.604
73
Specifications
Operating Range
n [rpm]
Option
Ball bearings in place of sleeve bearings
Pigtails in place of terminals
36
11600
9.46
8420
3.71
0.137
13.7
0.472
74
48
10200
6.09
6880
3.66
0.0889
11.5
0.262
72
Comments
Continuous operation
In observation of above listed thermal resistance
(lines 17 and 18) the maximum permissible winding
temperature will be reached during continuous operation at 25C ambient.
= Thermal limit.
Short term operation
The motor may be briefly overloaded (recurring).
30
10900
10.6
7750
3.79
0.157
13.3
0.517
74
4.61
8.3
12.8
23.1
31.1
39.7
58
76.2
183
0.114 0.206 0.314 0.558 0.759 0.956 1.38
1.75
4.04
7.4
9.93 12.3
16.4
19.1
21.4
25.7
29
44
1290 962
779
584
501
446
372
329
217
804
804
815
825
817
827
838
865
905
7.32
7.31
7.33
7.33
7.35
7.38
7.36
7.39
7.51
0.869 0.868 0.859 0.849 0.859 0.852 0.838 0.816 0.793
Thermal data
17 Thermal resistance housing-ambient
18 Thermal resistance winding-housing
19 Thermal time constant winding
20 Thermal time constant motor
21 Ambient temperature
22 Max. permissible winding temperature
35 K/W
12 K/W
7.75 s
343 s
-30+85C
+125C
21
12000
16.9
8920
3.79
0.248
14.9
0.909
75
Overview on page 16 - 21
Recommended Electronics:
ESCON 36/2 DC
Page 292
ESCON 50/5
292
Notes
18
maxon DC motor
121