Sunteți pe pagina 1din 6

RE 18136-05/05.

00

RE 18 136-05/05.00

4/2-way directional spool valves with solenoid actuation Type YKE1


Nominal size 1 Maximum operating pressure 350 bar Maximum flow 50 L/min
H/AID 6543/00

Type YKE1.A/C

Overview of contents
Contents Features Ordering details Function, section, symbol Technical data Characteristic curves, performance limits Unit dimensions, cavity Page 1 1, 2 2 3 4 5

Features
Direct operated directional spool valve with solenoid actuation Flow can be passed in both directions Wet pin DC solenoids Rotatable solenoid coil With protected hand override

Ordering details Y
Cartridge Spool valve Electrical Standard 350 bar Nominal size
Pressure

N9
No code = FKM seals Without plug-in connector 2) Coil junior timer (on request) Protected hand override 24 V DC Wet pin DC solenoid, with removable coil Series

=Y =K =E = No code =1
No. of Symbols
2 4

K4 = C4 = N9 = G24 = C= A=
1) 2)

Cavity

1)

350 bar

connections 4

qV = L/min

=D
1
2

See page 5 Plug-in connectors must be ordered separately (see page 2) Type YKE1DA/CG24N9K4 YKE1EA/CG24N9K4 YKE1FA/CG24N9K4

3
4

T-31A

50
1 2 3

=E
4

=F
1 3

Preferred types Material No. 00978202 00978203 00976508

YKE1

1/6

RE 18 136-05/05.00

Ordering details: plug-in connectors to DIN 43 650 A and ISO 4400 for component plug "K4"
Further plug-in connectors see RE 08 006

Material No.
With indicator light 12 240 V 00057292 With indicator light and Z-diode protective circuit 24 V 00310995

Colour Grey Black

Without circuitry 00074683

Function, section, symbol


General: The cartridge solenoid actuated valves are direct operated pressure balanced 4/2-way directional spool valves. They control the start, stop and direction of a flow. The cartridge valve basically comprises of a housing (5), bush (6) that can move within the housing (5) a control spool (9) as well as a return spring (8). In the de-energised condition the control spool (9) is held in its initial position by the return spring (8). The control spool (9) is actuated via the wet pin solenoid (7).
2 4

The various symbols are obtained by using the appropriate spool (D; E and F). Ports 1, 2 and 3 can be, continuously, applied with an operating pressure of 350 bar and the flow can be passed in both directions (see symbols). The hand override (10) makes it possible to switch the valve without energising the solenoid. Preferrably port 3 is to be used as the pump connection, ports 2 and 4 for the actuators and port 1 as the tank connection.

Symbol "E":

5 10

1 2 9 3 4 8 7

Rexroth Hydraulics

2/6

YKE1

RE 18 136-05/05.00

Technical data (for applications outside these parameters, please consult us!)
General
Installation Ambient temperature range Weight C kg Optional 30 to + 50 0.6

Hydraulic
Maximum operating pressure Maximum flow Pressure fluid FKM seals Pressure fluid temperature range Viscosity range Degree of contamination C mm2/s bar L/min 350 50 Mineral oil (HL, HLP) to DIN 51 524; Fast bio-degradable pressure fluids to VDMA 24 568 (also see RE 90 221); HETG (rape seed oil); HEPG (polyglycol); HEES (synthetic ester); other pressure fluids on request 20 to + 80 (with FKM seals) 2.8 to 500 Maximum permissible degree of contamination of the pressure fluid is to NAS 1638 class 9. We, therefore, recommend a filter with a minimum retention rate of 10 75.

Electrical
Voltage type Available voltage
1)

DC V % W ON OFF ms ms 24 10 19 Continuous 80 50 Up to 1500 IP 65


2)

Voltage tolerance (nominal voltage) Power consumption Duty Switching time to ISO 6403 (solenoid horizontal) Switching frequency Protection to DIN 40 050 Maximum coil temperature
1) 2)

cycles/h C

150 When connecting the electrics, the protective conductor (PE must be connected according to the relevant regulations. )

Further voltages on request. Due to the occuring surface temperature of the solenoid coils, please observe the European standards EN563 and EN982!

YKE1

3/6

Rexroth Hydraulics

RE 18 136-05/05.00

Characteristic curves (measured at = 41 mm2/s and = 50 C)


p-qV-characteristic curves symbol D
Pressure differential in bar
16 14 12 10 8 6 4 2 0 10 YKE1D 41 34 32

p-qV-characteristic curves symbol F


Pressure differential in bar
16 14 12 10 8 6 4 2 0 10

YKE1D 21

YKE1F 34

YKE1F 21

20

30

40

20

30

40

Flow in L/min

Flow in L/min

p-qV-characteristic curves symbol E


Pressure differential in bar
12 10 8 6 4 2 0 10 20 30 40 YKE1E 34 YKE1E 21

Flow in L/min

Performance limits (measured at = 41 mm2/s and = 50 C)


Attention! The stated switching power limits are valid for applications with two directions of flow (e.g. from P to A and simultaneous return flow from B to T). Due to the flow forces acting within the valve (e.g. from P to A and port B closed), the permissible performance limit for one flow path may be considerably reduced! (Please consult us in such cases.) The switching power limits were determined as the solenoids at their operating temperature, 10% under voltage and with no pre-loading of the tank.

Flow over two control lands and with pre-opening of the tank 3 4 / 2 1
350

Operating pressure in bar

300 250 200 150 100 50 0 10 20 30 40 YKE1F YKE1D

YKE1E

50

60

Flow in L/min 1 = Tank 2 = Actuator B 3 = Pump 4 = Actuator A

Rexroth Hydraulics

4/6

YKE1

RE 18 136-05/05.00

Unit dimensions / cavity T-31A; 4 actuator connections; thread M20 x 1,5 **


82,7 (88,7) 037 15

Dimensions in mm

6
05

9 10 5
1 2 3 4 5 6 7 8 9 10
21,11** 21,21

8
LS stop

Actuator connection 1 Actuator connection 2 Actuator connection 3 Actuator connection 4 Plug-in connector to DIN 43 650 must be ordered separately, see page 2 Space required to remove the plug-in connector Protected hand override 24 A/F; tightening torque, MA = 45 to 50 Nm Dim. for plug-in connector without circuitry Dim. ( ) for plug-in connector with circuitry
0,8 Recommended distance from the surface (with spot face)

86,6

68

30

4
0,000 LS

32,0 32,1

1,6 Recommended distance from the surface (without spot face)

3,96 12,7 Min. distance for area with full threads 18,54** 18,64 29,72 17,70** 17,75 52,71

A 20,68

20,62

LS stop (dim. ref. edge)


15,9

0,000

85

30 R0,25 30 R0,25 30 R0,25

4
14,3

21,44

3
14,3

45,24

2
75,95 85,12 85,22

16,79** 16,84 15,88** 15,93

68,28

Support for the valve bush


Min.102,4 (valve working range)

max. 0,25 x 45

1
11,9

Free area for solenoid 39 mm Min. spacing (central axis to the central axis of an identical cavity)

General dimensional tolerances 0.05 A ** Concentricity 0.2 mm One pos. (X,X) 0.1 mm Two pos. (X,XX) 1/2 Angular tolerance 1,6 Surface finish 0,5 Corner radius

YKE1

5/6

Rexroth Hydraulics

RE 18 136-05/05.00

Notes

Mannesmann Rexroth AG Rexroth Hydraulics D-97813 Lohr am Main Jahnstrae 3-5 D-97816 Lohr am Main Telefon 0 93 52 / 18-0 Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0 E-Mail product.support@rexroth.de Internet www.rexroth.com

Mannesmann Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 0 14 80/22 32 56 Fax: 0 14 80/21 90 52 E-mail: info@rexroth.co.uk

The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract.

All rights reserved Subject to revision

6/6

YKE1