Galvanic Isolation

Transient Protection

Balanced Transmission

CE Approved

Strmslingeomvandlare Current Loop Converter Stromschleifenwandler

www.westermo.se

Westermo Teleindustri AB 1998 REV. A

Specifications
Transmission Interface 1 Interface 2 Data rate Indicators Isolation Isolation voltage Overvoltage protection Asynchronous, full/half duplex or simplex EIA RS-232-C/CCITT V.24 25-position D-sub female, DCE 20 mA current loop, selectable active or passive Up to 19.2 bit/s Power, RD, TD Galvanic isolation with opto-coupler (data transmission) and transformer (supply) 1500V Mains: Breakdown voltage 440V at 230V AC and 220V at 115V AC Interface 2: Breakdown voltage transmitter and receiver 37V Surge capacity 0.6 kW for 1ms Switchable 115/230V +15/ 10% 4862Hz 100mA fast 5x20 mm Max 5VA at 230V AC 550C, ambient temperature 095% RH, non-condensing 161x53x139 mm 0.5 kg With rubber pads or screws. Screws: remove the two "keyholes" on the bottom of the case

Power supply Fuse Power consumption Temperature range Humidity Dimensions WxHxD Weight Mounting

Switch settings
The MA-21 can through different switch settings be adapted to a vareity of running conditions. To set the switches, open the plastic case by placing and turning a screwdriver between top and bottom at the rear of the case.

DANGER! DO NOT OPEN CONNECTED UNIT


MAINS LINE CONNECTION V.24/RS-232-C CONNECTION

1 23 4 5

6021-2002

S1 S2
S5 S3 S4 S2 S1
ON 1 - 9 OFF

ON 1 - 6 1 - 6 OFF 1 - 4

S3 S4 S5

Selection of transmitted signal, selection of signal controlling CTS Selection of transmitter/receiver normal or inverted Selection of receiver active/passive Selection of transmitter active/passive Selection of power supply 115/230V AC

Transmitted signal
ON

CTS controlled by
ON

S1
1 2 3 4 5 6 7 8 9 ON

TD

S1
1 2 3 4 5 6 7 8 9 ON

RTS

S1
1 2 3 4 5 6 7 8 9 ON

AUX

S1
1 2 3 4 5 6 7 8 9 ON

RD

S1
1 2 3 4 5 6 7 8 9 ON

SRS

S1
1 2 3 4 5 6 7 8 9

Always high

S1
1 2 3 4 5 6 7 8 9

DTR

Receiver active/passive
ON

Inverted Transmitter/Receiver
Transmitter
ON

S3
1 2 3 4 5 6 ON

Passive

Receiver Normal

S3
1 2 3 4 5 6

Active

S2
1 2 3 4 ON

Normal

S2
1 2 3 4 ON

Inverted

Normal

Transmitter active/passive
ON

S2
1 2 3 4 ON

Normal

Inverted

S4
1 2 3 4 5 6 ON

Passive

S2
1 2 3 4

Inverted

Inverted

S4
1 2 3 4 5 6

Active

Factory settings
ON ON ON ON

S1
1 2 3 4 5 6 7 8 9

S2
1 2 3 4

S3
1 2 3 4 5 6

S4
1 2 3 4 5 6

6021-2002

Connections
Line connection Terminal connection (DCE) (5-position screw-terminal) (RS-232-C/V.24, 25-position D-sub, female)
Direction Receiver Receiver Transmitter Transmitter No. Description 1 2 3 4 5 R+ RT+ TShield Direction 1) Pin CCITT V.24 no. Circuit no. I O I O O O I I I 2 3 4 5 6 7 8 11 19 20 103 104 105 106 107 102 109 120 108/2 Description TD/Transmitted Data RD/Received Data RTS/Request To Send CTS/Clear To Send DSR/Data Set Ready SG/Signal Ground DCD/Data Carrier Detect AUX/Auxiliary SRS/Secondary Request to Send DTR/Data Terminal Ready

1) I= Input O= Output on MA-21

Line connection
MA-21
Receiver
1 2 3

Twisted pairs
R+ RT+ T-

20mA current loop equipment


T+ TR+ RReceiver Transmitter

Transmitter Shield 1)

4 5

1) If shielded cable is used, connect the shield only at one end to avoid ground currents.

Transmission range (interface 2)


Transmission rate bit/s Cable 42pF/m 0.3mm2 600 6000m 1200 5000m 2400 4000m 4800 3000m 9600 500m 19200 200m

10

6021-2002

MA-21 DC
Specifications Power supply Power consumption Insulation Fuse F1 All other specifications according 1236V DC Max 3W 1000V 1.6 A fast 5x20 mm to MA-21 AC

Switch settings
According to MA-21 AC

Connections
According to MA-21 AC, except power supply
Connection no. 1 2 3 Power Supply Voltage + Voltage
POWER 12-36VDC LINE CONNECTION V.24/RS-232-C CONNECTION

123

1 2345

6021-2002

11

Hints
The 20mA current loop interface, or TTY as it is sometimes known, is a popular industrial communications standard. The system relies on a current generator running on both the transmit and receive circuits. On each circuit it is important to have only one current generator supplying current into that circuit. For this reason the MA-21 can have its current generators set to be either active or passive. It is important to check the state of all attached equipment to ensure correct setting on the MA-21. The MA-21 has the same line interface as MD-21, MD-29 and are hence compatible. The RS-232 interface is configured as DCE (Data Communication Equipment). Most printers, PCs and terminals are set as DTE (Data Terminal Equipment). Some recomendation of cable configurations are given below. If any problems do occur on set up of theMA-21, the LEDs will be helpful. PWR: The unit has power. RD: Data received on line interface. TD: Data received on RS-232 interface. A good way to check the MA-21 is to carry out a loop back test. Ensure that either the transmitter or receiver are set to active, but not both active or passive. Connect T+ to R+ and T- to R-. Connect the RS-232 port to a terminal. When keys are pressed on the terminal you should receive the echo on screen. The TD & RD lights will both flicker simultaneously as you press the keys.

DTE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

MA-21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

DTE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

MA-21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

9-pos. PC 1 2 3 4 5 6 7 8 9

MA-21 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

12

6021-2002

Connecting the MA-21 in a current loop


TD 4 3

Full duplex transmission


2 1 S1: 1, 5, 7, 8 on S2: 1, 3 on S3: 36 on S4: 36 on

RD

Slave

S1: 1, S2: 1, S3: 1, S4: 1,

5, 7, 8 on 3 on 2 on 2 on

Slave

TD

RD

TD

RD

Functional description The TD led flashes on the master when transmitting from it. The RD led flashes on the slaves. When transmitting from a slave the TD led flashes only on that unit. The RD led flashes only on the master modem.
4 3

TD

Half duplex transmission


2 1 S1: 1, 5, 7, 8 on S2: 1, 3 on S3: 1, 2 on S4: 36 on

RD

Slave

S1: 1, S2: 1, S3: 1, S4: 1,

5, 7, 8 on 3 on 2 on 2 on

Slave

TD

RD

TD

RD

Functional description When transmitting from the master, RD and TD flash. RD flashes on the slaves. When transmitting from a slave both RD and TD flash. On the other slaves and the master RD flashes.
6021-2002 13

Block diagram
V.24/RS-232 +24VB PWR 2) TD AUX SRS DTR DSR DCD 2 11 19 20 6 8 +12V +12V S1 9 CTS RTS RD 5 4 3 8 7 6 5 0V SG PG 7 1 1) R51 +12V 0V -12V R47 +12V RD S3 S2 3 4 0VB 3 1 4 2 5 6 1 2 1) R50 PE PE F1 Power Supply Isolated power supply +24VB 0VB 0VB 1) R48 5 R+ RShield PE 20mA S1 1 2 3 4 S2 1 2 TD 0VB 3 1 4 2 5 6 +24VB S4 20mA Line

3 4 1) R49

T+ T-

PE

1) 0 resistors R48-R51 are normally not mounted. 2) Metal housing on D-sub is connected to PE

Westermo Teleindustri AB have distributors in several countries, contact us for further information.

Westermo Teleindustri AB S-640 40 Stora Sundby, Sweden Phone +46 16 612 00 Fax +46 16 611 80 E-mail: info@westermo.se Westermo Web site: www.westermo.se Subsidiaries
Westermo Data Communications Ltd Solent Business Centre Millbrook Road West Millbrook, Southampton SO15 0HW Phone: +44(0)1703-704 611 Fax.:+44(0)1703 702 682 E-Mail: sales@westermo.co.uk Westermo Data Communications GmbH Bruchsaler Strae 18, 68753 Waghusel Tel.: +49(0)7254-95400-0 Fax.:+49(0)7254-95400-9 E-Mail: westermo.germany@t-online.de

S-ar putea să vă placă și