1. Version 3.2.0.0 ........................................................................................................................... 3 1.1 New Features .................................................................................................................. 3 1.2 Resolved Issues ............................................................................................................. 15 1.3 Known items being worked ......................................................................................... 17 1.4 Installation Instructions ............................................................................................... 17

Release Notes

1. Version 3.2.0.0
1.1

New Features
LTE Troubleshooting Metric: LTE DL Throughput Analysis This metric finds all the points in the drive where the UE was served with DL Throughput lower than a certain value (DL App Throughput condition). It then further evaluates each of those points and categorizes them based on root cause of low throughput.

LTE Troubleshooting Metric: LTE Low CINR Analysis This metric finds all the points in the drive where CINR was lower than certain value (CINR Threshold). It then further evaluates each of those points and categorizes them based on root causes.

Release Notes

Support for per antenna measurements collected with R&S TSMW LTE scanner on DataPro. Support for JDSU Handheld 17.03 Support for packet trace data embedded within TEMS Investigation log files. Translation of 28 bit LTE Cell Identity in SIB 1 to eNodeB ID Sector ID

Feature to customize content of the tool tip. The user may now select any of the four options listed below to be displayed on the tooltip: 1. General 2. RF Metrics 3. Serving/Neighbor 4. Data Session

Release Notes

Implemented support for DL MOS Display on the Map, user can view DL MOS logged by Accuver xcal under map window: VoLTE --> Audio Quality --> Audio

Implemented VOLTE RTP metrics: Delay, Jitter, Packet Loss, and RTT are now available to be viewed in map, table, time series chart, xy chart, pdf chart, and User Query

Enhanced Elevation Profile in Wind Catcher Plus by providing the synchronization between Map window and the Elevation profile window. Implementation of Ascom Data Transfer Stalled event for Ascom Symphony files

A new Event called Ascom Data transfer Stalled has been introduced to capture conditions where the data transfer stalls and does not recover before the end of the task. 5

Release Notes

For time based FTP get, FTP put, HTTP get, HTTP Put and HTTP Browse tests: This logic will only apply to time based tests. This logic will not be evaluated if Bytes Transferred for HTTP Put Task > 50 MB. This logic will not be evaluated for tasks that end in user break or system break Logic: If the last byte transferred within a task was more than 2.5 seconds before the pre-defined task duration then Ascom Data Transfer Stalled event will be issue at the time of last successful transfer and Corresponding Task Failure event will be issued at the end of the task. For Example: Lets say that the predefined Task Duration for time based tests is 25 seconds. A task has last successful data transfer at 21.5 sec from the time of first SYN. Since 25 21.5 = 3.5 (greater than the threshold of 2.5 sec), this is a data transfer stall.
Implemented adjustable Weak PCI Threshold for LTE PCI Usefulness TT#22641

Implemented the feature to allow the user to choose the message color in the Message Window. Right-click on the message type for which the color needs to be changed.

Implemented the Option to choose the number of processors to be used to process data in WCP.

Release Notes

SMS support for Swissqual files. TT # 22102 Support for Swissqual vendor events 1. SWISSQUAL CALL_START 2. SWISSQUAL CM START DIAL 3. SWISSQUAL CM DIAL 4. SWISSQUAL CM INCOMING_CALL 5. SWISSQUAL CM CONNECTED 6. SWISSQUAL CM DISCONNECTED 7. SWISSQUAL CM CONNECT_FAILED 8. SWISSQUAL VENDOR CM BREAK 9. SWISSQUAL CM SYSTESM_RELEASE 1487 Addition of exception cause within the exception file for WPCM. Support for version information within the data in the version_information table. TT # 21648 PCAP support for Swissqual. TT # 21956 LTE support for Accuver (V4.01.69). TT # 22599 Implementation of the 12 sec looks ahead after abnormal BCCH transition for Swissqual and TEMS UMTS data. TT # 21956, 22598 Inclusion of the Signaling Control Release Indicator (SCRI) message within the definition for UMTS call end. TT # 21956 Support for Agilent and Swissqual WiFi data. TT # 22068

Implementation of the stop measurement frame within Swissqual files. The Swissqual events after this frame will not be processed. TT # 22647 New events added for Agilent UMTS multi RAB support. TT # 22068

Release Notes

1. CC_DISCONNECT 2. CC_RELEASE 3. MM_SERVICE_REQUEST 4. MM_SERVICE_REJECT 5. MM_ATTACH_REQUEST 6. MM_ATTACH_REJECT 7. MM_DETACH_REQUEST 8. SCRI_MESSAGE 9. UMTS_RADIO_BEARER_RELEASE 10. UMTS CS call Start 11. UMTS CS Call End 12. UMTS PS call Start 13. UMTS PS Call End Implemented the feature to allow the keyword search in the Message Window to be noncase sensitive. Support to see the tool tip as long as the user keeps the cursor on the bin. Enhancement in iDEN Monitor View of phone data browser, now both RSSI and SQE charts have the same information on the X-axis. For the sectors that contain "No Data" we simply get a bar with "Zero" Value

Implementation of a new information table in the phone data Browser, which helps user to do RF analysis. This is available together with the charts from the phone data browser.

Release Notes

Implemented Co-Chanel Analysis for iDEN: This feature allows the user to plot a similar sector thematic but with the channel information. When right-clicking the sector, the user would be able to choose the Co-Channel field, inside the Co-Chanel user would be able to select any of the possible channels (PCCH or TCH). Once the channel is selected the other sectors having PCCH equal to the selected will be highlighted as green.

Release Notes

Added a new iDEN Metrics Dominant SQE Sector based on Sector Label

Implementation of Zoom in/out with mouse Scroll in Time Chart, user will be able to zoom in/out the X-axis in the time chart using the Mouse scroll button when the cursor is inside time-chart area. Added a new Event EVENT_ANDREW_AUTOCALL_ACCESS_FAILURE for Andrew Invex Autocall vendor in the User Interface . Support for SwissQual Events, separate all SwissQual Events in events Side A and events Side B. For example SwissQual Call Dropped would be now SwissQual Call Dropped - A or SwissQual Call Dropped - B, depending where it was found. Implementation of 180 degree Line drawn when a sector is chosen through the RF Analysis.

Implemented a change to start the Lines for link to bin sector from the edge of cell as shown:

Implementation of UMTS Setup Time and RF Setup time metric in UDQ, Data Table, time Charts, Histogram and Batch Print. These metrics are added under the UMTS Call Statistics group.

10

Release Notes

Support for Dingli events 1. Dingli data task FTP upload 2. Dingli data task FTP upload success 3. Dingli data task FTP upload drop Implementation of Support for Swissqual vendor events 1. Swissqual Vendor status Call Completed B 2. Swissqual Vendor status System Release B 3. Swissqual Vendor status call start type 4. Swissqual Vendor Call Marker - Start Dial B 5. Swissqual Vendor Call Marker - Dial B 6. Swissqual Vendor Call Marker - Incoming B 7. Swissqual Vendor Call Marker - Disconnect B 8. Swissqual Vendor Call Marker - Connected B 9. Swissqual Vendor Call Marker - Failed B 10. Swissqual Vendor Call Marker - Break B 11. SwissQual Data Task FTP Put B 12. Swissqual Vendor Call Marker - Released B 13. SwissQual Data task - POP3 Get B 14. SwissQual Data task - POP3 Get Failed B 15. SwissQual Data task - SMTP Send B 16. SwissQual Data task - SMTP Send Failed B 17. SwissQual Data Task FTP Get B 18. Swissqual Vendor Call Marker - Released B 19. SwissQual Data task - POP3 Get B 20. SwissQual Data task - POP3 Get Failed B 21. SwissQual Data task - SMTP Send B

11

Release Notes

22. SwissQual Data task - SMTP Send Failed B 23. SwissQual Data Task FTP Get B 24. SwissQual Data Task FTP Get: Throughput Update B 25. SwissQual Data Task FTP Put: Throughput Update B 26. SwissQual Data Task FTP Completed B 27. SwissQual Data Task FTP Fail B 28. SwissQual Data Task Ping Failed B 29. SwissQual Data Task Ping Success B 30. SwissQual Data Task HTTP Get B 31. SwissQual Data Task HTTP Completed B 32. Vendor reported call status - <status> B 33. Swissqual Vendor status Call Failed B 34. Swissqual Vendor status Call Dropped B Added support for Channel Configuration in Processing Default>RF configuration

Implementation of Neighbor Addition and Removal, this feature will allow the user to change the neighbor list on the map. Implementation of Sector Label column in UDQ and data Table View:

12

Release Notes

Implementation of UMTS SQI Metrics in User Interface as shown:

Support to export .tab cell sites file to a google earth .KML format

Implementation of a Pop-Up Window when exporting metrics/Events. This feature will display a message 'Export Completed" and an 'OK' button after metrics/events exported to .tab, .csv, .kml. Added a new iDEN Intra-Cell Handover Success Event for no layer 3 data. Metric not being decoded - LTE UL MAC Retransmission - Nemo Added a New variable in configurations to make 'Background Processing' default, User has the option to turn it off if needed. Implementation of Legend export to Google Earth, this functionality allows the user to see the legend in Google Earth as they see in WindCatcher Plus. Implemented following features for Kodiak

13

Release Notes

1) Android version, server information.


Software Version CDE-07_002.03.09P_UI-7.2.3.15C_Android_Version-4.0.4

2) Separate Initial Media from In-call Media


KPI 4 Initial Media Latency 1.230 0.340 2.890 1.124 1.460 2.501 In-Call Media Latency (MOC) 0.302 0.000 0.394 0.314 0.347 0.377 In-Call Media Latency (MTC) 0.380 0.250 0.570 0.390 0.421 0.468

3) Technology into detail sheets

4) Call type into call detail

Implemented following Kodiak IPA Events based on MSGA events

1. 2. 3. 4. 5. 6.

Kodiak IPA Send Attempt Kodiak IPA Send Success Kodiak IPA Send Fail Kodiak IPA Receive Attempt Kodiak IPA Receive Success Kodiak IPA Receive Fail

14

Release Notes

1.2

Resolved Issues Resolved the issue where drive route bin selection sometimes synced the map to a different location that was not selected by the user. Resolved the issue where WindCatcher was not remembering printer settings. Support for displaying Sector PNs and Cell Site name when printing Maps. TT # 22525 WindCatcher is displaying values that are disabled in QCAT and is not carrying forward constant RX1 values after the receiver is disabled. TT # 22621 Support to view the Vocoder Rate Metrics in WindCatcher Plus. TT # 22707 Fix for PDSCH Total Downlink Throughput (kbps) values in WindCatcher Plus. TT # 22842 Support for post processing TEMS Pocket files .trp TT # 22751 Support for channel frequency 0 for LTE Swissqual data. TT # 22101 Manual merge for database. TT # 22209 LTE and CDMA scanner support for Anritsu. TT # 22228 Resolved incorrect manual merge for LTE Anritsu data. TT # 22242 Resolved missing throughput data for Bell custom report. TT # 22108 Resolved the managed_error message during WPCM processing. TT # 21705, 22110 Resolved the Ping RTT metric greyout within the metric menu. TT # 22102 Resolved the unknown log message observed in the message window for Swissqual UMTS data. TT # 22515 Resolved bad lat/long values for Agilent iDEN files. TT # 22142 Resolved missing SIB messages for Agilent UMTS data. TT # 22508 Resolved the issue of exception file list being overwritten during append in WPCM. TT # 22636 Support for TEMS Pocket 12.3 data TT_#21621 Resolved the error when Modifying Thresholds on an active layer. TT# 12215 Resolved iDEN Phone in scan mode not being reported for .ILF Updated the power _data_Summary calculations for iDEN - Invex Receiver (.ILF) Resolved the Incorrect PDSCH, PUSCH values in data table JDSU TT#21800 Resolved iDEN UDQ Metrics for Receiver Resolved missing Invex 3G Receiver frequencies for iDEN. Resolved mismatch information between tooltip and the phone data browser Resolved DingLi LTE Files not being processed Resolved the issue of Comarco Seven.Five Scanner not being processed in WCP Time Chart - Scrolling the chart with Mouse Left-Button Pressed 12648 Resolved Comarco 7.5 3G Scanner Discrepancies Resolved the issue of No layer 3 messages for R&S data Resolved RTT values not showing up for Sector 2 Accuver/XCal data TT# 22587 Resolved the WCP hanging when processing TEMS data Resolved Receiver data not being processed for Agilent .sd5 Resolved not able to plot Active pilot metrics for CDMA TEMS TRP data TT# 22523 Resolved the issue of incorrect Data Table Export to mapinfo file Resolved Slow Comarco file Processing issue Resolved WCP Unable to populate Setup Time values for IDEN .aod Files version 16.3-3 Removed the comma in the EARFCN channels numbers JDSU TT# 21999 Resolved the issue of WCP crashes while processing 3GB Ascom QMD data file TT# 22762 Resolved Inconsistent MCC Data for GSM TEMS Resolved Nemo In-building 6.3.1.11 data not processing in WCP TT# 21662 Resolved the missing R&S UMTS scanner data issue TT# 22613

15

Release Notes

Resolved Missing Forward FCH FER values for Nemo TT# 22684 Resolved the duplication of Handover Complete Event number in SD5 files Resolved the issue of PSC and Ec/Io not showing correctly on the map for Swissqual data TT# 22810 Resolved WCP Unable to display multiple segments of the route Resolved the Issue with Screen Resolutions smaller than 800 pixels on the vertical Axis Resolved the undefined Event for LTE Swissqual TT# 22870 Resolved the issue of Batch Print troubleshooting metric plots TT# 22671 Resolved the Unhandled exception Error when closing an Active dataset in WCP 3.1.7.4 Resolved the issue of Inconsistent Data displayed under the layer control for Device ID Support for Dingli Huawei series Qualcomm CDMA phone. Resolved the issue of missing data points for CDMA phone JDSU TT# 22136 Resolved PCTEL Scanner data processing issue .DTR TT # 22946 Resolved the issue of WCP showing different outputs for the same XCAL scanner data TT# 23019 Resolved the Ding Li EVDO Processing issue Resolved the LTE CQI, Tx Power and LTE RLC Bler Metrics not showing up for NEMO data Resolved the Issues with User defined query for LTE TEMS/XCAL TT# 21794 Resolved the issue of Band_class" and "Frequency_chan" not being populated in the Data Table for TEMS CDMA, UMTS, and LTE Resolved the image and distance binning issue in Custom report Resolved the Polygon Cut feature not working Correctly TT#22931 Resolved Zoom level of custom reports images not following screen zoom level Resolved Workspace is not saving all metrics issue. Resolved discrepancies in the iDEN 3G events in the Andrew Invex Files Resolved LTE RRC Connection Request missing content and RRC Setup Message missing info. Included a more detailed message body for LTE RRC Connection Request Message, and NAS message at the end of RRC Connection Setup Complete message

16

Release Notes

Resolved VoLTE HTC file RTP metrics calculation Updated algorithm to remove duplicated packets with same timestamps which caused abnormal RTP metric results

1.3

Known items being worked


Support for Accuver In-building data Support for Accuver data task statistics

1.4

Installation Instructions

If a previous version of WindCatcher Plus is already installed on the computer, then while installing the new version a pop-up window will appear to uninstall the existing version.

17

Release Notes

Please install Microsoft Framework 4.0 from http://www.microsoft.com/download/en/details.aspx?id=17851 The link includes Microsoft .NET Framework 4 client profile Framework 4 Extended. Once Microsoft Framework 4 is installed, users can verify complete installation by checking the following installs using program list.

All windows applications must be closed prior to WindCatcher installation. If stand alone license (Dongle) is in use, the user should unplug the dongle before starting the installation. Download the WindCatcher.msi file and run it to begin the installation. Follow installation steps and click Finish when complete.

18