SPARE PART NOTICE

Services, Wrtsil Finland Oy Engine section 23 WECS Engine type Ref. WFIS Date 29.11.2007 Issue 01 Document No. WS23P003 Page 1(2)

See below

Relay module RM10 replaced by RM11a


Engine type This bulletin concerns WRTSIL 20, 32, 46, WRTSIL Vasa 32 and 32LN engines equipped with WECS 2000 (Wrtsil Engine Control System). The relay module RM-10 has been replaced by a new type, RM-11a. When replacing the RM-10 with RM-11a the actions described below must be observed.

General

LUBE OIL SHUTDOWN LUBE OIL SHUTDOWN BLOCKING OPTIONAL SHUTDOWN MCU STOP/SHUTDOWN LOCAL STOP OVERSPEED SHUTDOWN EMERGENCY STOP WECS WATCHDOG STOP/SHUTDOWN OVERRIDE SHUTDOWN RESET LUBE OIL SHUTDOWN SWITCH FAILURE

STOP RELAY LOCAL START BLOCKING LOCAL START WECS START FUEL LIMITER SLOW TURNING FAILURE ALARM SPEED SWITCH 1 SPEED SWITCH 2 SPEED PULSE

BACKUP

U1

U2

U3

U4

U5

+ 12 VDC

OVERSPEED BY-PASS

OPTIONAL SHUTDOWN SWITCH FAILURE ENERGIZED STOP SOLENOID FAILURE EMERGENCY STOP FAILURE

RELAY MODULE
RM-11

SHORT CIRCUIT

Instructions

On RM-11a the cable supervision circuits are using a 10 kohm end resistor instead of 100 kohm resistor used by the RM10. These resistors needs to be changed if cable supervision failure alarms trigger when installed. See Fig 1 of typical connections on the RM for the cable supervision resistors
R4 n.c. R5 1 R6 Optional shutdown switch R7 R8 2
10k

Lube oil press, switch

PSZ201 2x0,75 Cu

1 2

1 3 2

10k

PSZ201 P Lube oil pressure switch

Fig 1. Typical cable supervision resistor connections on the Relay Module

Wrtsil Finland Oy Services, Vaasa Wrtsil Finland Oy Services, Turku

P.O. Box 252 (Tarhaajantie 2) FIN-65101 Vaasa, Finland P.O. Box 50 (Stlarminkatu 45) FIN-20811 Turku, Finland

Telecop. +358 10 709 1847 Telecop. +358 10 709 1380 Telecop. +358 10 709 3279 Telecop. +358 10 709 3410

Tel. +358 10 709 0000 Tel. +358 10 709 0000

Business ID 0773744-3 Registered Office: Vaasa

Services, Wrtsil Finland Oy Issue 01

Spare Parts Notice Document No. WS23P003 Page 2(2)

The emergency stop input has also a cable supervision function on the RM-11a and here a 10kohm resistor needs to be added over the contact switches of the external emergency stop button. See fig 2 for a typical connection.
10k X4.8 RM.R12 31 32 W1 41x0.75 31 32 X1.D1 X1.D2 24 VDC reference for emergency stop input Emergency stop input Emergency stop

Fig 2. Typical cable supervision resistor connection for the emergency stop button.

For further information about the connections please check installation specific drawings.
Ordering instructions Contact your closest Wrtsil Service Network. When ordering please specify the engine serial number and part number: Ref type 32 W20 W32 W46 Letter distribution Letter validity Part number 501 135 501 027 516 037 502 035 Version 0002 002 007 002 Description Relay module Relay card Relay card Relay card

Wrtsil Service Network and owners/operators of engines concerned. Until further notice.

2007 Wrtsil Finland Oy All rights reserved No part of this publication may be reproduced or copied in any form or by any means (electronic, mechanical, graphic, photocopying, recording, taping or other information retrieval systems) without the prior written permission of the copyright holder. Wrtsil Finland Oy makes no representation, warranty (express or implied) in this publication and assumes no responsibility for the correctness, errors or omissions for information contained herein. Information in this publication is subject to change without notice. Unless otherwise expressly set forth, no recommendation contained in this document is to be construed as provided due to a defect in the engine, but merely as an improvement of the engine and/or the maintenance procedures relating thereto. Any actions by the owner/operator as a result of the recommendations are not covered under any warranty provided by Wrtsil and such actions will thus be at the owners/operators own cost and expense. NO LIABILITY WHETHER DIRECT, INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL, IS ASSUMED WITH RESPECT TO THE INFORMATION CONTAINED HEREIN. THIS PUBLICATION IS CONFIDENTIAL AND INTENDED FOR INFORMATION PURPOSES ONLY.