Sunteți pe pagina 1din 4

RE 29 929/12.

99

RE 29 929/12.99
Replaces: 04.97

Compact Power Supply Types VT-NE30, VT-NE31 and VT-NE32


Series 1X

H/A 5348/96

Types VT-NE30, VT-NE31 and VT-NE32

Table of contents
Contents Features Ordering code Technical data Terminal allocation Unit dimensions Page 1 1 2 2 3

Features
VT-NE30 power supply unit (unipolar output voltage): For the voltage supply to amplifiers for all proportional valves For the voltage supply to proportional valves with integral electronics VT-NE31 power supply unit (bipolar output voltage): For the voltage supply to amplifiers for servo-valves VT-NE32 power supply unit (unipolar output voltage): Same function like VT-NE30 power supply unit In addition, regulated output voltage for the supply to closedloop control or evaluation electronics or accessory components such as pressure transducers, position measuring systems Compact build, connection via terminal strip Unregulated output voltages (filtered); for VT-NE32, additionally regulated output voltage Vibration strength to DIN IEC 68, insulation testing to VDE 0113 Short-circuit protection by means of fine-wire fuses in the output circuits; with VT-NE32, disconnection of the regulated output after approx. 1.5 s in the case of overloading or short-circuit; restart by pressing the reset key Can be screwed on or snapped onto DIN rail LED lamps Conforms with EU directives (CE sign)

Ordering code VT
Compact power supply unit, unipolar Compact power supply unit, bipolar Compact power supply unit, unipolar and regulated = NE30 = NE31 = NE32

1X / *
Further details in clear text 1X = Series 10 to 19 (10 to 19: unchanged technical data and terminal allocation)

VT-NE30 VT-NE32

1/4

RE 29 929/12.99

Technical data (for applications outside these parameters, please consult us!)

VT-NE30

VT-NE31 output 1 output 2 filtered

VT-NE32 output 1 filtered output 2 regulated

filtered Operating voltage Frequency Ausgangsleistung Output power (at U = 230 VAC): no load full load Load current Residual ripple (with full load) Fuse Connection cross section Permissible ambient temperature range Storage temperature range Weight
1)

filtered

U f PA UA UA Imax U IS A

230 VAC 10 % or 115 VAC 10 % 47 to 63 Hz 70 VA + 31 VDC 1) + 26 VDC 1) 2,5 A < 3 VAC 4AT max. 4 mm2 20 to + 50 C 20 to + 70 C 2,2 kg 1,3 kg 2,4 kg < 3 VAC 0,8 A M 7 VA + 27 VDC 1) + 24 VDC 1) 7 VA 27 VDC 1) 24 VDC 1) 0,25 A < 3 VAC 0,8 A M 60 VA + 30 VDC 1) + 25 VDC 1) 0,25 A < 3 VAC 0,8 A T 25 VA + 24 VDC + 24 VDC 2,5 A 1 A < 50 mVAC see features

In the case of deviation of 10 % from the operating voltage U = 230 VAC, the output voltage UA changes by 10 %.

Note: For details regarding environment simulation tests in the fields of EMC (electromagnetic compatibility), climate and mechanical stress, see RE 29 929-U (declaration on environmental compatibility).

Terminal allocation

Connection of operating voltage


230 VAC 115 VAC

P
The compact power supply units VT-NE30 to VT-NE32 are delivered ready-to-connect to an operating voltage of 230 VAC. With screw-on type assembly the plate for the clip-connection has to be removed.

0 115 0 115

0 115 0 115

Rexroth Hydraulics

2/4

VT-NE30 VT-NE32

RE 29 929/12.99

Unit dimensions
4. connection secondary side only with VT-NE30 and VT-NE 31 5. and 6. connection secondary side only with VT-NE32

(dimensions in mm)

125,5 (VT-NE30) 120,0 (VT-NE31) 124,0 (VT-NE32)

4x fixing slot 4,8 x 9

Plan view VT-NE30

Plan view VT-NE32

0 115 0 115

0 115 0 115

74

60

80

VT-NE30

+ VT-NE32

64 85 64

Plan view VT-NE31

85

0 115 0 115

47,5

59,5

+24 0 24 VT-NE31

56 78 81

VT-NE30 VT-NE32

70

3/4

Rexroth Hydraulics

102

82

RE 29 929/12.99

Notes

Mannesmann Rexroth AG Rexroth Hydraulics D-97813 Lohr am Main Jahnstrae 3-5 D-97816 Lohr am Main Telefon 0 93 52 / 18-0 Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0 eMail product.support@rexroth.de Internet www.rexroth.com

Mannesmann Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 0 14 80 / 22 32 56 Fax: 0 14 80 / 21 90 52 E-mail: info@rexroth.co.uk

The specified data is for product description purposes only and may not be deemed to be guaranteed unless expressly confirmed in the contract.

All rights reserved Subject to revision

4/4

VT-NE30 VT-NE32