ZXSDR B8200&R8840 (V4.

0) Project Survey Report


(Production Arrangement and Delivery Data)
(20081230-R1.0)

Contract No.: Party A: Party A's Contact: Tel/Fax: Office: Surveyor: Date: Tel/Fax:

2013/7/8

Statement
All rights reserved. No part of this documentation may be excerpted, reproduced, translated, annotated or duplicated, in any form or by any means without the prior written permission of ZTE Corporation. and are the registered trade marks of ZTE Corporation. The names and logos of ZTE products are proprietary logos or registered trade marks. The names of other products and companies mentioned in this manual may be proprietary to their owners respectively. Without the prior written permission of ZTE or the owners of thirdparty trade marks or trade names, this manual does not grant the reader any permission or right to use any marker appeared in the manual. The product described herein conforms to the design requirements of environment protection and human security. The storage, usage, and discard of the product shall comply with the manual, related contract, or laws and regulations of related countries. The actual product may differ from what is described in this standard due to frequent update of ZTE products and fast development of technologies. Please contact the local ZTE office for the latest updating information of the product. For the latest document information, please visit http://support.zte.com.cn

Feedback Table
You are invited to give your suggestions and opinions to improve ZTE user manuals and enjoy better service by sending emails to ydshyf@zte.com.cn. Thank you for your cooperation!
Document Name Product Version No. Please provide your information for further contact: Name Post Code Tel Very Good General View Basic information Material specification s Material notes Wieldy tables Comments Correct content You may give suggestions from any perspective such as the content, structure, details, depth, expression, figures/tables, special tools, FAQ and so on. The suggestions are not confined to this document. Company Address E-mail Good Ordinary Bad ZXSDR B8200&R8840 (V4.0) Project Survey Report (Production Arrangement & Delivery Data) (20081230-R1.0)

Document Version No.

Suggestions

enjoy better service by

a) (20081230-R1.0)

Very Bad

etails, depth, expression, nt.

No.

Site Information

Site Type NodeB configuration

B8200 Basic Information

Installation mode

Power supply mode specified power cable (piece) length of specified power cable (m)

B8200 Power length of power cables Supply and length of dry contact monitoring Cable cable (m)
length of RS232/485 serial port cable (m) length of PGND cable (yellowgreen) (16mm2) (m) Digital trunk cable specification Digital trunk cable Trunk length (m) cable bearing DDF connector type DDF connector quantity Iub tail fiber type Length of a single section of optical fiber (m) Iub Transmission Optical fiber Tail fiber (pcs) bearing ODF connector type Need flanges to connect operator's optical fiber? Network cable routing Length of super-5 network cable (m) RJ45 crystal connector quantity (pcs)

Ethernet bearing

GPS Feeders

Feeder type Feeder length (m)

Others

Is antistatic floor required or not? Antistatic Height of the antistatic floor floor upper surface (mm) Total length of the indoor cable trays (m)
Length of indoor PVC troughs (m)

Others

Quantity of indoor ground bars Need the feeder window or not? Remarks

No.

Site Information Site Type


NodeB configuration Method 1 Installation Method Method 2 Method 3 Method 1 RRU Quantity Method 2 Method 3 Power supply mode specified power cable quantity (piece) length of specified power cable (one single piece) (m) length of PGND cable (16mm2) (one single piece) (m)

R8840 Installation

R8840 power supply and cable

Outdoor lightning proof box monitor cable quantity (piece)

length of outdoor lightning proof box monitor cable (1 single piece) (m) AISG cable quantity (piece) length of AISG cable (1 single piece) Outdoor grounding bar quantity( near the R8840) Sector 1 feeder cable specification Sector 2 Sector 3

Feeder
length of feeder(m)

Sector 1(1 single piece) Sector 2(1 single piece) Sector 3(1 single piece) length of -48V blue power cable (25 sq.mm) (m)

Indoor lightning proof box

length of -48V black GND power cable (25 sq.mm) (m) length of yellow-green PGND cable (35 sq.mm2) (m) power supply type quantity Installation Method outdoor cable type Outdoor lightning proof box 1 outdoor power cable length (m) Outdoor lightning proof box 2 Specification cabling length Specification number, if it is installed to post number, if it is installed to wall

Outdoor lightning proof box

Outdoor lightning proof box

outdoor power cable length (m)

Outdoor lightning proof box 2 Outdoor lightning proof box 3

cabling length Specification cabling length

the length of 1 single piece of yellow-green PGND cable (16 sq.mm) (m) Sector 1 specification BBU-RRU outdoor fiber quantity Sector 2 Sector 3 Sector 1 Sector 2 Sector 3 Sector 1 specification RRU cascaded outdoor fiber quantity Sector 2 Sector 3 Sector 1 Sector 2 Sector 3 Length of outdoor PVC troughs (m) Total length of the outdoor cable trays (m) whether sunshade is required or not? outdoor buckle type

Outdoor fiber

Others

Remarks

ZXWR BBUB&R8840 (V4) Project Survey Report--Production Arrangement & Delivery Data

Project Survey Memorandum


Indicate the following contents: Materials that are not specified in the engineering interface; 2) Some special situations in the survey field, such as the overlong cables, special connectors, etc. 3) Materials involved in the contract such as the cables connecting the outdoor ground bars and the ground net, supporting poles and lightning rods, ect. 4) Other materials ZTE has to provide in the equipment room, such as the PVC cable troughs.

User's comments

Signed by the user's representative: Date:

ZTE's comments

Signed by the surveyor:

Date:

Note: This Survey Report specifies the basic data for engineering materials and equipment installation, and shall not be modified once confirmed by both parties. If the user needs to modify the data, he shall contact the local office of ZTE in time. ZTE will not be responsible for any delay of equipment delivery and project implementation due to the modification to the survey results required by the user.

Delivery Data

The Nearest Outdoor Gro

Outdoor Grounding Bar Closed to The Feeder Window

Outdoor Indoor

Protection G - 48V

Working G

Ethernet C

Optical Fibe

Cable Supp

Cable Sup

16 mm2 Yellow green 16 mm2 Yellow green 16 mm2 Yellow green

Antenna

The Nearest Outdoor Grounding Point


Dedicated Power Cable For R8840 Monitor

Outdoor lightning arrester

R8840

Outdoor Grounding Bar Closed to The Feeder Window


Grounding Clip For R8840 Power Cable

Grounding Clip For R8840

Power Cable

Connecting with power distribution cabinet when It is not used when indoors installing indoors installing R8840 R8840

Outdoo

Optical Fiber

Indoor

35 mm2 Yellow green


25 mm2 Blue

Indoor lightning arrester

Monitor cable

LC/PC Connector

Outdoor

Indoo

Select From the 3 Access ModesOptical Fiber,E1 Cable,Ethernet cab Optical Fiber LC/PC Connector E1 Cable Ethernet cable

25 mm2 Black
2- cored Own Power Cable

Protection Gground - 48V Working Ground Ethernet Cable Optical Fiber Cable Supplied by Customer Cable Supplied by ZTE

Power Distribution Cabinet

B 8200

35 mm2 Yellow Green

16 mm2 Yellow Green 16 mm

DDF /Transmission Equipment Switch

ODF/ Optical Switch

E1 Cab

Ethernet

2 Yellow

Green
2

16 mm Yellow Green
2 Yellow Green 16 mm

Indoor Grounding Bar

Note:
1. It is applied to roof installation (single).

Diagram of equipment connection (single installation)

2. The outdoor lightning arrester is not needed

3. The equipment is grounded at nearest place

Antenna

Type D

Type N

Outdoor lightning arrester

Dedicated Power Cable For R8840 Monitor

R8840

Cable

Connecting with power distribution cabinet when It is not used when indoors installing indoors installing R8840 R8840

Outdoor Optical Cable

Optical Fiber

Outdoor Indoor

Select From the 3 Access ModesOptical Fiber,E1 Cable,Ethernet cable) Optical Fiber Single - Mode 0ptical Fiber

Cable

DDF /Transmission Equipment Switch

ODF/ Optical Switch

E1 Cable

net cable Ethernet cable

RNC or NODEB

Green
2

6 mm Yellow Green
2 Yellow Green 16 mm

Note:
1. It is applied to roof installation (single). 2. The outdoor lightning arrester is not needed when R8840 is installed outdoors. 3. The equipment is grounded at nearest places (like outdoor cabling rack).
.

on

16 mm2 Yellow green 16 mm2 Yellow green 16 mm2 Yellow green 16 mm2 Yellow green 16 mm2 Yellow green 16 mm2 Yellow green

Antenna

Outdoor Grounding Bar Closed to R8840

Ty 16 mm Yellow green
2 2

16 mm2 Yellow green


Outdoor Grounding Point

16 mm Yellow green

Outdoor lightning 2 16mm arrester

Dedicated Power Cable For R8840 Monitor

R8840

Grounding Clip For R8840 Power Cable

Connecting with power distribution cabinet when It is not used when indoors installing R8840 indoors installing R8840
Grounding Clip For R8840 Power Cable

Outdoor Op

Outdoor grounding bar ( feeder ) Near the window

For

Outdoor Indoor

35 mm2 Yellow green


25 mm2 Blue

Indoor lightning arrester

Monitor

Protection Gground - 48V Working Ground Ethernet Cable Optical Fiber Cable Supplied by Customer Cable Supplied by ZTE

25 mm2 Black 2cored Own Power Cable Power Distribution Cabinet

LC/PC

B8200

35 mm2 Yellow Green

16 mm2 Yellow Green 16

Indoor Grounding Bar

Diagram of equipment connectio (installation mode of over 2 secto

16 mm2 Yellow green 16 mm2 Yellow green 16 mm2 Yellow green 16 mm2 Yellow green 16 mm2 Yellow green 16 mm2 Yellow green

Antenna

Antenna

Antenna

Type D

Type D

Ty

Type N
Dedicated Power Cable For R8840 Monitor Dedicated Power Cable For R8840 Monitor

Type N
Dedicated Power Cable For R8840 Monitor

Typ

Yellow green

Outdoor ghtning 2 mm rrester

R8840

Outdoor lightning 2 16mm arrester

R8840

Outdoor lightning mm2 arrester

R8840

Connecting with power distribution cabinet when It is not used when indoors installing R8840 indoors installing R8840
Grounding Clip For R8840 Power Cable

Outdoor Optical Cable Grounding Clip For R8840 Power Cable

It is not used when indoors installing R8840

Connecting with power distribution cabinet when indoors installing R8840

Outdoor Optical Cable Grounding Clip For R8840 Power Cable

Connecting with power distribution It is not used when cabinet when indoors installing R8840 indoors installing R8840
Outdoor Optical Cable

Outd Indoor

ow green
25 mm Blue
2

Indoor lightning arrester


2

Monitor Select From the 3 Access Modes Optical Fiber,E1 Cable,Ethernet cable) Optical Fiber LC/PC Connector Single - Mode 0ptical Fiber

25 mm Black 2cored Own Power Cable Power Distribution Cabinet

B8200

E1 Cable Ethernet cable

35 mm2 Yellow Green

16 mm2 Yellow Green 16 mm

DDF /Transmission Equipment Switch

ODF/ Optical Switch

E1 Cable

RNC or NODEB

Ethernet cable

2 Yellow

Green
2

16 mm Yellow Green
2 Yellow Green 16 mm

Indoor Grounding Bar

Note:

1. It is applied to tower installation, 2 sectors and 3 sectors pole installation modes. 2. The outdoor lightning arrester is unnecessary when R8840 is installed indoors. 3. When two R8840s are installed at one place, another independent R8840 is nearly grounded.

Diagram of equipment connection (installation mode of over 2 sectors)

Antenna

Type D

Type N

Outdoor lightning mm2 arrester

Dedicated Power Cable For R8840 Monitor

R8840

Connecting with power distribution It is not used when cabinet when indoors installing R8840 indoors installing R8840
Outdoor Optical Cable

Outdoor Indoor

installation modes.

nstalled indoors.

dent R8840 is nearly grounded.

1 2 3 4 5 6 7 8 9 10

Remarks for Filling B8200 Tables Each B8200 is provided with a special power cable.

The total length (m) of the green-yellow PGND cables (of a cross sectional area of 16mm 2) shall cover the The length of the digital trunk cable means the length of the cable route from the equipment to DDF. According to the transmission mode surveyed in the field, enter the corresponding information in the item If the E1 cable in the field is longer than 150m and the tail fiber is longer than 100m, remark them in Proje The length of a single section of the tail fiber means the length of the cable route from the equipment to O If the flanges to connect the operator's optical fibers should be provided by ZTE, please indicate it in Proj The height of the antistatic floor uppper surface (mm) means the height from the cement ground to the an The network cables are delivered in coils. Each network cable is equipped with three Type-RJ45 connect The installation modes are as shown in the figure below:

Installed to the wall (by a bracket)

BC8180 Carbinet installed to the wall

Installed in a ZXDU58 W121 M02 Carbine Installed to the wall (by a bracket)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21

Remarks for Filling R8840 Tables This report supposes each NodeB has at most three installation modes for R8840. The engineers should The R8840 quantity should be consistent with the installation mode. For example, if the installation mode R8840 special power cable means the power cable between R8840 and outdoor lightning arrester. Each R8840 is provided with a special power cable. In principle, the master feeder should be a 7/8-inch feeder. If the feeder of one sector under NodeB is longer than 60m, 5/4-inch feeders can be used uniformly for al If the feeders of all the sectors under NodeB are shorter than 20m, 1/2-inch feeders should be used. If the 1/2-inch feeder is chosen, specify the connector type (DIN, N, or M/F) in Remark. Total length of delivered master feeders = Length of a single section of the master feeder (Sector1)*2 + L The length of the master feeder for each sector shall be consistent with its specification. The default specification of the indoor lightning arrester is one-to-three. The power cable for the indoor lightning arrester means the power cable between the power distribution b The default specification of the outdoor lightning arrester is one-to-two. The outdoor cable of the outdoor lightning arrester means the power cable between the indoor lightning a The shielding and lighting-protective ground clip shall be clamped at the two ends of the outdoor cable of The quantity of the outdoor cables for each sector shall be consistent with their specifications. A sun shade must be provided for the outdoor installation. And it is not provided for the indoor installation

If the lowest temperture is below -25 oC, the stainless steel buckles shall be used. Otherwise, use the the In default, each R8840 is provided with an outodoor lightning arrester monitoring cable. And it default leng PVC cable troughs should be used if the equipment is to be installed to the wall. The installation modes are as shown in the figure below:

Installed to wall

An R8840 installed to pole

Back-to-back installation mode for 2 R8840

Combined installation of three R8840

sectional area of 16mm 2) shall cover the lengths of all PGND cables needed for this NodeB. e route from the equipment to DDF. he corresponding information in the item of the trunk cable or the tail fiber. longer than 100m, remark them in Project Survey Memorandum. the cable route from the equipment to ODF. ovided by ZTE, please indicate it in Project Survey Memorandum. height from the cement ground to the antistatic floor upper surface. equipped with three Type-RJ45 connectors (one is standby).

stalled in a ZXDU58 W121 M02 Carbinet

modes for R8840. The engineers should choose a proper mode according to the actual conditions in the field. de. For example, if the installation mode is a combined installation of three R8840, then three R8840 shoulde be prepared. 840 and outdoor lightning arrester.

nch feeders can be used uniformly for all the sectors under NodeB. m, 1/2-inch feeders should be used. N, or M/F) in Remark. ction of the master feeder (Sector1)*2 + Length of a single section of the master feeder (Sector2)*2 + Length of a single section nt with its specification.

er cable between the power distribution box and the indoor lightning arrester.

wer cable between the indoor lightning arrester and the outdoor lightning arrester. d at the two ends of the outdoor cable of the outdoor lighting arrester. If the outdoor cable is longer than 30m, add a clip in the m stent with their specifications. is not provided for the indoor installation.

es shall be used. Otherwise, use the the anti-ultraviolet buckles. ester monitoring cable. And it default length is 2m.

n R8840 installed to pole

ombined installation of three R8840

e R8840 shoulde be prepared.

tor2)*2 + Length of a single section of the master feeder(Sector3)*2.

longer than 30m, add a clip in the middle.