SHARP TROUBLE & ERROR CODES SF-2025, SF-2030

(Trouble codes list)


Trouble status code L4 L5 Subordinate code 01 03 04 05 06 01 00 01 20 21 02 04 00 01 02 03 04 00 01 02 03 08 09 10 00 00 01 02 04 05 06 02 31 32 F2 Description Main motor lock detection No.4/5 mirror motor error detection No.4/5 mirror motor MHPS error detection Lens motor error detection Lens motor LHPS error detection Power supply line frequency error detection Open thermistor (Test command 14 to reset) Heat roller high temperature detection (Test command 14 to reset) Heat roller low temperature detection (Test command 14 to reset) Memory. Counter sumcheck error detection (Test command 16 to reset) Mirror motor lock detection Mirror motor MHPS error detection ADU alignment plate malfunction detected ADU rear plate malfunction detected ADF communication trouble detected A motor malfunction detected B motor malfunction detected Resist sensor malfunction detected Eject sensor malfunction detected Desk communication trouble detected Desk-1 cassette liftup motor trouble detected Desk-2 cassette liftup motor trouble detected Desk-3 cassette liftup motor trouble detected Desk 24V line error detected LCC motor overcurrent detected Desk transport motor trouble detected Communication trouble between PC/Modem and the copier. Sorter communication trouble detected Paper jog malfunction detected Transport motor malfunction detected Indexer lower limit detected Indexer upper limit detected Shift motor malfunction detected Toner motor malfunction detected ID sensor level abnormality (less than 3V) ID sensor photo conductor surface level abnormality (less than 2.25V) DM sensor level abnormality (less than 3V) DM sensor cannot sense. When measuring the gain level (at 1.5 rotations of the drum) DM sensor cannot sense. When measuring the patch (at 1.5 rotations of the drum) Adjustment impossible for GB (-32V * 4 times) Adjustment impossible for GB (+32V * 7 times) Preliminary adjustment impossible for GB (-200V to -88V) Main unit upper cassette liftup motor trouble detected Main unit bottom cassette liftup motor trouble detected Toner sensor indicates extreme overtoned condition Toner sensor indicates extreme undertoned condition Original size detect sensor level abnormality.

L8 H2 H3 H4 U2 U3 U4

U5

U6

U7

F1

35*

F3 EE CC

12 22 EL EU

Mark " * ": The error display is given only when performing the simulation. (For the process control at warming-up,, the error display is not given.)

Display codes other than trouble


Trouble codes CH PC PF Sub code Door open/DV unit uninstalled Personal counter uninstalled/auditor code input waiting Copy inhibit command is received from the host when installing PC/Modem. Operation

8 18

S-ar putea să vă placă și