Sunteți pe pagina 1din 12

BTS/BSC Commands

BTS COMMANDS: ALLIP; RLBDP:CELL=cell; RLBDC:Cell=cell, CHGR=x; RLCCC:CELL=cell,CHGR=0,SDCCH=1,TN=1; RLCFP:CELL=cell; RLCFI:CELL=cell,CHGR=0,DCHNO=XX; RLCPC:CELL=cell,[SCTYPE=sctype], [MSTXPWR=mstxpwr, BSPWRB=bspwrb, BSPWRT=bspwrt] Print alarm list for the switch Print number of BPCs (Basic Phys. Channels) for the cell Change BPCs for the specified cell and CHGR Change SDCCH/8 configuration for cell Print channel numbers assigned to cell Assign channel number to cell Change power levels for specified cell. SCTYPE - Sub Cell type: UL=Underlay OL=Overlay ALL=The obvious. (MUST HALT SECTOR FIRST) RLCPP:CELL=cell; - Print Power level for specified cell for BSPWRB (Power level for BS on BCCH), BSPWRT (Power level for BS -not BCCH), MSTXPWR (Mobile station TX Power level). Values are 33-45 for BS power levels, Even numerals 4-30 for MSTXPWR. RLCRP:CELL=SFXXXA; - Print Cell Resources for the Cell RLDEP:CELL=SFXXXA; - Print Channel number and CGI for the sector RLDEC:CELL=SFXXXA,BCCHTYPE=COMB; - Set BCCH type to COMB (or NCOMB) RLNCP:CELL=SFXXXA; - Print Neighbors for specified cell RLNRP:CELL=cell,CELLR=ALL; - Print neighbor relation data, including other switches RLSLE:CELL=SFXXXA; - Deactivate Cell Logical Channels Availability Sup. RLSLI:CELL=SFXXXA; - Activate Cell Logical Channels Availability Sup. RLSLC:CELL=SFXXXA,CHTYPE=TCH,LVA=X; - Change alarm point for cell logicals alarm, usually one less than the total number of channels in the cell. RLSTC:CELL=SFXXXA,STATE=HALTED; - To Halt a sector RLSTC:CELL=SFXXXA,STATE=ACTIVE; - To Activate a Sector RLSTP:CELL=SFXXXA; - Status of Sector RLVAP; - Print list of SDCCH and TCH that are never used or continuously busy. RXAPE:MO=RXOTG-X,DCP=ALL; - Disconnect TG from RBLT24 devices RXAPI:MO=RXOTG-X,DEV=RBLT24-XX&&-XX,DCP=XX&&XX; - Connect TG to RBLT24 devices RXAPP:MO=RXOTG-X; - Print RBLT24s connected to the Site RXASP:MO=RXOTG-XX; - Print alarm situation for the specified MO. If the MO is RXOTG, the command prints alarm information for subordinate MOs also. RXASP:MOTY=RXOTG; - Print quick list of all BTS related alarms in switch. RXBLE:MO=RXOTS-XX-X-0&&-7; - Deblock MO RXBLI:MO=RXOTS-XX-X-0&&-7; - Block MO RXCDP:MO=RXOTG-XX; - Print configuration data for all MOs in that TG (Channel rxNumbers, TCH, etc.) RXELP:MO=RXOTRX-XX-X; - Print Error Log for MO RXELR:MO=RXOTRX-XX-X; - Reset error log for MO RXESE:MO=RXOTS-XX-X-0&&-7; - Take MO out of service RXESI:MO=RXOTS-XX-X-0&&-7; - Bring MO back into service RXLTI:MO=RXOTS-XX-XX-X; - Initiate loop test on time slot RXMDP:MO=RXOTRX-XX-X; - Print devices connected to MO RXMDP:MOTY=RXOXX,DEV=RBLT24-XX; - Print which MO of specified type is connected to the device (CF, TRX, TS only). If the device is BUSY use MOTY=RXOTS. If device is SEBU use MOTY=RXOTRX or RXOCF. RXMFP:MO=XX; - Print faults on the MO RXMOC:MO=XX,(parameter=x); - Change configuration of a MO (Cell, antenna, diversity, etc.) RXMOE:MO=XX; - Delete MO RXMOP:MO=XX; - Print configuration of MO (Cell, antenna, swver,etc.) RXMSP:MO=RXOTG-XX; - To get status of an MO: RXOCF-XX; OPER - Operational RXOTF-XX; FAIL - MO Self test Failed -

RXOIS-XX; RXOTRX-XX-X; RXORX-XX-X; RXOTX-XX-X; RXOTS-XX-X-0&&-7; RXMSP:MO=RXOTG-XX,SUBORD; RXBLI:MO=RXOTG-XX,SUBORD; RXESE:MO=RXOTG-XX,SUBORD; RXMFP:MO=RXOCF-XX; RXTCE:MO=RXOTG-XX,CELL=cell,CHGR=x; RXTCI:MO=RXOTG-XX,CELL=cell,CHGR=x; RXTCP:MOTY=RXOTG,CELL=SFXXXA; RXTCP:MO=RXOTG-XX; RXTEI:MO=XX; DIP/SNT COMMANDS: DTBLE:DIP=XRBLT; DTBLI:DIP=XRBLT; DTIDP:DIP=XRBLT; DTSTP:DIP=XRBLT; DTDIP:DIP=XRBLT; DTQUP:DIP=XRBLT; DTQSP:DIP=XRBLT; DTQSR:DIP=XXRBLT,DEGR,UNACC; EXDAE:DEV=xxx; EXDAI:DEV=xxx; NTBLE:SNT=ETRBLT4-XX; NTBLI:SNT=ETRBLT4-XX; NTCOP:SNT=ETRBLT4-XX,DIPINF; NTTEI:SNT=ETRBLT4-XX; RABLP:DETY=XXX; RACII:DEV=RALT24-XXX&&-YYY,CIC=XXX; RADEP:DEV=RBLT24-XXX; RAPTI:DEV=RALT24-XX; RAPTI:LCH=TCH-XXXX; RASAP;

NOOP - Not Operational COM - Defined and in service, but manually blocked DEF - Defined, out of service Print status of all MOs in site at once Block a whole site down at once Unload a whole site at once Print Fault information for MO Disconnect TG from Cell Connect TG to Cell Get TG number for the Cell Print cells attached to the TG Test MO

RASAR:DETY=RALT24; RASSP:DETY=RALT24; RXMDP:MO=RXOTRX-XX-X;

RRDSL:SNT=RTTF1S2-X,SUID=XX,UC; RRDSP: SNT=RTTF1S2-x; RRTBE:DEV=RTTF2D-XX; RRTBI:DEV=RTTF2D-XX(,force);

STDEP:DEV=RBLT24-XX&&-XX;

- Deblock the DIP - Block the DIP - Print initial data for DIP (LC and FRS must be 1 for ESF/B8ZS) - Status the DIP - Get SNT Number for the DIP - Print quality supervision values for the DIP - Print quality supervision parameters for the DIP - Clears quality supervision hits on the DIP - Remove a device from service - Bring device into service - Deblocks the SNT - Blocks the SNT - Print Devices on that SNT, for all DIPs - Test the SNT - Print blocking supervision levels for DETY - Assign CICs to RALT24 type devices. If doing a range of devices, just put the CIC for the 1st device and they will sequence. - Print SNT for specified RBLT24 - Initiates call trace on specified device - Initiate call trace on a specific traffic channel - If "SEIZURE SUPERVISION OF DEVICES IN BSC" alarm of RALT24 devices is active, this command will print those devices that have never been used, or have been continuously busy. - Clears "Seizure supervision of devices in BSC"alarm - Prints data on Seizure supervision alarm - Print device information for the MO (CF,etc.) This tells what transcoder devices and Radio Handler devices the MO is connected to, along with RBLT24s. - Load a TRAB board (SNT) - Print software version of a TRAB board (DETY, ACL, Period length, status) - Deblock individual transcoder device - Block individual transcoder devices (Actually blocks 5 devices, the one specified and the next 4. The one specified is a MUX and the next 4 are DEMUX). - Status individual devices on the DIP

GROUP SWITCH/SYNCHRONIZATION COMMANDS: GSBLI:TSM(SPM,CLM)=tsm(spm,clm) GSTEI:TSM(SPM,CLM)=tsm(spm, clm) GSBLE:TSM(SPM,CLM)=tsm(spm,clm) GSCDR:TSM=tsm; Block a GS unit Test a GS unit Deblock a GS unit Remove clock distribution from a TSM

GSDSP:TSM=tsm;(,noreset;) GSCVP; NSDAP; NSSTP; NSBLI:CCM(DIP,EXT,RCM)=XXX; NSBLE:CCM(DIP,EXT,RCM)=XXX; NSTEI:CCM(DIP,EXT,RCM)=XXX; NTCOP:SNTP=TSM-X-0&&-15; RP COMMANDS: BLEME:RP=XX,RPT=XX,EM=X; BLEMI:RP=XX,RPT=XX,EM=X; BLRPE:RP=rp; BLRPI:RP=rp; DIRRP:RP=rp; DPECS:RP=rp, [CM=cm[all]] EXEMP:RP=rp,EM=ALL; EXRPP:RP=rp; EXRUP:RP=rp; EXTRP:TYPE=RPM6A; FCRWS:RP=rp,WS=sep; RADRP:DEV=dev; EXDRP:DEV=dev; REPRI:RP=X; REMRI:RP=rp, [,EM=em], PCB=pcb; RECRI:RP=rp; CP COMMANDS: EXIT; DICEP:REC=TEMP; DICEP:REC=PERM; DICEP:REC=BITE; DIECP:INF=SPO; DIECP:INF=PAR; DIRCP;

- Print Disturbances for a TSM (Will reset unless NORESET is specified) for each SNTP - Print CLM control values (note daily and compare) - Print clock reference supervision - Print clock reference state - Block a clock reference - Deblock a clock reference - Test a clock reference - Print whats on a specific TSM Deblock the EM Block the EM Deblock the RP Block the RP RP Event Record Changes cm (em) control from RP to the twin See what's on the RP,and devices on each EM Status for RP and its twin Print RP Software Unit Data Print RP Properties Block RP, makes accessible only from seperated side of CP Tells what RP the device is on (in the BSC) Tells what RP the device is on (in the MSC) Diagnostic test To replace a board Deblock and repair check

DPHAS; DPPAI; DPSES; DPSWI;

- Halt the Standby side of the CP


- Restore CP to normal state

Exit local mode, log off from terminal Print recent temporary CP errors Print recent permanent CP errors Print recent CP Bit Errors Print Error Interrupt information (FC 3 means no errors) Print information from Error Interrupt during parallel start Print CP Error Record (APZ 212 20 only)

- Separate the SB side from the WO side - Switch operational sides of the CP (Executive to Standby and vice-versa)
Print state of CP Access Local mode in the CP Disconnect from CPT Connect to CPT function in CPG CP State (Same as DPWSP) Print CP Processor load

DPWSP; MCLOC:USR=SYSTEM,PSW=INIT; PTCOE; PTCOI; PTWSP; PLLDP; ALARM/IOG COMMANDS:

ALACP; - Print Alarm Category Data (Which ALCAT is which number) ALALP; - Print status of ALI ALCLP; - Print alarm class data ALCLC:ACLNO=0,ACL=A1,ALDB; - Set up alarm panel to ring bell for A1 alarms ALDIP; - Print Alarm Display type. Type 1 for ALAMP board ROF 137 7946/1, Type 2 for any other type. (Check if you dont get a buzzer for A1 alarms.) ALEXI:DEV=EXAL2-XX; - Connect alarm receiver and external alarm (add the alarm into the switch) ALEXL:DEV=EXAL2-XX,ALCAT=X,ACL=XX; - Load external alarm data (Alarm class, alarm category)

ALEXP;

- Status all EXAL2 external alarm recievers in switch. ALLTI:ALI=0; - Test Alarm panel (Flash lights and ring bell) ALRDL:DEV=EXAL2-XX,CAW1=SLOGAN 1, CAW2=SLOGAN 2,AC=X; - Load alarm receiver data (Slogan, normally open or closed) ALRDP; - Print alarm reciever data. BLEAE:DEV=EXAL2-XX; - Deblock an external alarm receiver device BLEAI:DEV=EXAL2-XX; - Block an external alarm receiver device BLSLE:SPG=0,LINK=X; - Deblock CP-SP link 0 or 1. BLSLI:SPG=0,LINK=X; BLSNE:NODE=B,SPG=0; BLSNI:NODE=B,SPG=0; RESUI:NODE=B,SPG=0; EXSLP:SPG=0; IMLCT:SPG=0; IMMCT:SPG=0; INMCT:SPG=0; END; :ILBLI:NP=1-1-1-2; :ILBLI:NP=1-2-2-1; :ILNPP:NP=1-1-1-2; :ILNPP; :ILSLC:NP=1-2-1-1,RATE=9600; :MCDVP:IO=AT-1; IMLCT:SPG=0; :SDTDP:RPTID=151,INT=24; :END; :SDRRP:RPTID=ALL,DETAILED,REFC; :END; - Block CP-SP link 0 or 1. Deblock the node Block a node (A or B) in the SPG Dignostic check of node Print SP link status Snake Eyes : (DCS/MCS subsystems) Snake Eyes : (SPS Subsystem) Snake Eyes : (FMS Subsystem) Back to normal (Communicate with CP) Block Network Port (Use IMLCT) Block OSS Port to NOC Print status of NP Print status of all ports Change baud rate of a port Shows what NP the specified IO is connected to

- Print 24-hr. traffic statistics report - Print detailed info about all statistic reports

IMMCT:SPG=0; :IMCSP; - Print status of SP nodes in IOG :END; INMCT:SPG=0; :INVOE:IO=OD-1,NODE=A - To remove optical disk from drive in IOG (Then push button on drive); :INVOL:IO=OD-1,NODE=A; - To load a disk INMCT:SPG=0; :INMEI:NODE=A,IO=OD-1,FORMAT=APN, VOL=TNMMDD; - To format a disk. (OD-1) Volume name follows the following convention: T = Switch type (B for BSC, M for MSC, H for HLR, etc.) N = Switch number (1, 2 etc.) MM = Month (2 digits) DD = Day (2 digits) Ex. BSC #1, 5/17/99 would be B10517 IMMCT:SPG=0; :INLIP:NODE=A; IMLCT:SPG=0; :IMHWP:NODE=A; INMCT:SPG=0; :INFIP:FILE=XXXXXX; :INFIP:VOL=XXXX; :INFIP:VOL=BTSVOLUMSW; :INFIP:FILE=RELFSW0; :INFIP:FILE=RELFSW0-R0; - Print performance history for hard disks and ICB - Print hardware configuration for the node Look at a file in the IOG See what files are in a volume in the IOG Check the current BTS software version Check contents of reload file; Check subfile of reload file

SS7 COMMANDS: RADCP; S7DEP:DEST=ALL; S7LAE:LS=1-173-10,SLC=XX,FORCE; S7LAI:LS=1-173-10,SLC=XX; S7SLP:LS=x-x-x-x; S7LSP:LS=xxx; S7SLP:LS=xxx; S7FLP:ST=S7ST-XX; S7RSP:DEST=XXXX; S7NCP:SP=XXX (or ALL),SSN=XXX(or ALL); S7NPI:SP=XXXX; (Point code of MSC) S7NSI:SP=XXX,SSN=222; Print the point code of the MSC Print all destination point codes connected to switch Deactivate SS7 link Activate link Print what SLC is connected to which S7ST Print state of Link Sets Print which S7ST is connected to which LS Print fault log of ST Print routing data for the destination Print SCCP Network configuration (Whether the point code is defined or not.) - Define a the MSCs point code in the BSC (&vice-versa) - Define the SCCP subsystem for the destination (use SSN 222 for BSC/MSC connections)

ADDING AN EXTERNAL ALARM (ex. SWITCH DOOR ALARM): 1. Load the alarm receiver data: 2. Load the external alarm data: 3. Add the alarm: 4. Deblock the alarm: IF SITE WON'T COME BACK UP... 1. Get status of CF: RXMSP:MO=RXOCF-XX; If NOOP BLO, then.. 2. Block CF: RXBLI:MO=RXOCF-XX; 3. Test CF: RXTEI:MO=RXOCF-XX; If answer comes back "No Fault Indications" then there is nothing wrong with the DXU. 4. Load CF: RXESI:MO=RXOCF-XX; If it won't load, then 5. Block and Deblock TG: RXBLI:MO=RXOTG-XX,FORCE; RXBLE:MO=RXOTG-XX; TRU FAULT, SPLITTING RP: (CF must be OPER, TRX NOOP, BLO=0440 or 0040) DONT DO THIS WITHOUT PERMISSION!! 1. 2. 3. 4. 5. 6. 7. Status the TRX: Print devices connected to the TRX: Print the RP# connected to the RHDEV: Split the RP: Block the RP: Deblock the RP: Check to see if sector is back up: RXMSP:MO=RXOTRX-XX-X; RXMDP:MO=RXOTRX-XX-X; RADRP:DEV=RHDEV-XX; FCRWS:RP=X,WS=SEP; BLRPI:RP=X; BLRPE:RP=X; RLCRP:CELL=cell; ALRDL:DEV=EXAL2-X,CAW1=SWTICH ROOM DOOR OPEN,CAW2=NAME OF BSC, AC=1; (Defines the alarm slogan, alarm confition (1=normally closed, 0=normally open) ALEXL:DEV=EXAL2-XX, ACL=A1, ALCAT=9; (Defines Alarm Class (A1), Alarm Category (8=Power, 9=Ext) ALEXI:DEV=EXAL2-XX; BLEAE:DEV=EXAL2-XX;

TRAB LOADING PROCEDURE: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. RRDSP:SNT=RTTF2S-XX; - Print current software version of the SNT. (Write it down) NTCOP:SNT=RTTF2S-XX; - Print devices for the SNT RRTBI:DEV=RTTF2D-XX&&-XX,FORCE; - Block the devices NTBLI:SNT=RTTF2S-XX; - Block the SNT NTTEI:SNT=RTTF2S-XX; - Test the SNT RRDSL:SNT=RTTF2S-XX,SUID=CAAW200004R1A,UC; - Load the software into the SNT. (Use SUID from RRDSP) If you get Fault Code 19-Non existent DSU, do this command: EXDTP:BLOCK=RTTF2S; - To find the current SW version for the TRAB, then repeat step #6. NTBLE:SNT=RTTF2S-XX; - Deblock the SNT RRTBE:DEV=RTTF2D-XX&&-XX; - Deblock the devices STDEP:DEV=RTTF2D-XX&&-XX; - Verify status of devices

ADDITIONAL TRA COMMANDS: RRMAP:TRAPOOL=ALL; RRTPP:TRAPOOL=ALL; RRDSE:SNT=RTTF2S-XX; - Print Devices which are in Mean Hold Time supervision alarm - Print TRA Traffic Gives total device count, # busy, # idle - Cancels a previously ordered software load for the SNT

ADDING 2ND TRU: 1. RXMOI:MO=RXOTRX-XX-X,TEI=tru#,DCP1=xxx,DCP2=xxx&xxx; - Define TRX. Use the TRU# TEI# DCP1 0 0 128 1 1 131 2 2 134 3 3 137 4 4 140 5 5 143 6 7 8 9 10 11 6 7 7 9 10 11 160 163 166 169 172 175 following values for DCP1 & DCP2: DCP2 129&130 132&133 135&136 138&139 141&142 144&145 161&162 164&165 167&168 170&171 173&174 176&177

6. RXMOC:MO=RXOTRX-XX-X,CELL=cell; - Assign TRX to Cell 7. RXMOI:MO=RXOTX-XX-X,BAND=PCS,ANT=BETAw,MPWR=45; - Define the TX. w=A, B, or C, depending on the sector. (If microcell use MPWR=33, if picocell use MPWR=21.) 8. RXMOC:MO=RXOTX-XX-X,CELL=cell; - Assign the TX to the sector 9. RXMOI:MO=RXORX-XX-X,RXD=AB,BAND=GSM1900,ANTA=BETAw,ANTB=ALPHAw; - Define the RX with Diversity. As before, w=Sector. (If using diversity, skip step # 10) 10. RXMOI:MO=RXORX-XX-X,RXD=B,BAND=GSM1900,ANTA=BETAw; - Define the RX without diversity. (Must do this if picocell) 11. RXMOI:MO=RXOTS-XX-X-0&&-7; - Define the Time Slots for the TRU. 12. RXMOP:MO=RXOTRX-XX-X&RXOTX-XX-X&RXORX-XX-X; - Check the definition of TRX, TX and RX 13. RXAPP:MO=RXOTG-tg; - Check the devices that support the TRUs. Must be 3 RBLT24 devices for each TRU. 14. STDEP:DEV=RBLT24-XXXX&&-YYYY; - Check the status of the IDLE devices on the dip. (Range given in RXAPP printout) 15. RXESI:MO=RXOTRX-XX-X; - Load TRX, will come back OPER 16. RXESI:MO=RXOTX-XX-X&RXORX-XX-X&RXOTS-XX-X-0&&-7; - Load the rest of the TRU, will come back COM 17. RXBLE:MO=RXOTX-XX-X&RXORX-XX-X&RXOTS-XX-X-0&&-7; - Deblock the MOs in the TRU 18. RXMSP:MO=RXOTRX-XX-X&RXOTX-XX-X&RXORX-XX-X&RXOTS-XX-X-0&&-7; - Check status of all MOs in the sector, all must be OPER 19. RLCRP:CELL=cell; - Check cell resources, must be 1-0-4-7 20. RLCFI:CELL=cell,CHGR=0,DCHNO=channel#; - Define Channel number (from planned works), wait 30 sec. 21. RLCFP:CELL=cell; - Verify channel numbers for the cell 22. RLCRP:CELL=cell; - Check cell resources, must be 1-0-4-15 23. RLCCC:CELL=cell,SDCCH=1,CHGR=0; - Increases the SDCCH from 4 to 12. Wait 30 seconds, then: 24. RLCRP:CELL=cell; - Check cell resources again, must be 1-0-12-14. (note: there should be a task in the PW for the NOC to change BCCHTYPE to NCOMB during the maintenance window, this will change resources to 1-0-8-14.) 25. RLSLC:CELL=cell, CHTYPE=TCH,LVA=13; - Increase Cell Logical alarm set point to reflect the added channels

Additional steps if using Frequency Hopping: 25. RLBDP:CELL=cell; - Print number of BPCs for the cell. Number will be given for both channel groups, 0 and 1 (or more). CHGR 0 will say SYSDEF, CHGR 1 will have a number equal to the number of TRUs in that channel group times 8 (CHGR 0 only has 1 TRU, all the rest will be in CHGR 1). For example, a sector with 3 TRUs will have 16 BPCs. A 4 TRU sector will have 24 BPCs. Use the following table:
# of TRUs in the sector 1 2 3 4 5 6 7 8 9 10 11 12 NUMREQBPC in CHGR 1 (or total between mult. CHGR) N/A 8 16 24 32 40 48 56 64 72 80 88

26. RLBDC:CELL=cell,CHGR=1,NUMREQBPC=X; 27. RLSTP:CELL=cell; 28. RLSTC:CELL=cell,CHGR=1,STATE=ACTIVE;

- Change the number of required BPCs for the cell - Check status of channel groups - look at CHGR 1 - Unhalt CHGR 1 (if halted)

Note: TRU adds at sites where Baseband frequency hopping is implemented must be performed during the maintenance window. You can check if a site has baseband hopping by looking at the following: RLCFP:CELL=cell;. There will only be one Channel Group (CHGR 0), only one frequency per TRU, and HOP will be set to ON. If you do RXCDP:MO=RXOTG-XX; the channels for the new TRU will show UNUSED and at the bottom will be a message saying MAIO EXCEEDS FREQUENCY SET SIZE. To get the TRU to come up you will have to turn the hopping off and back on again, as follows: RLCHC:CELL=cell,HOP=OFF; RLCHC:CELL=cell,HOP=ON; This will get the TRU up but will also reset the TX on each radio which will drop any calls active on the sector. This is why these type of TRU adds must be done at night. UNDEFINING TRU: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Block time slots: RXBLI:MO=RXOTS-XX-X-0&&-7; Block RX: RXBLI:MO=RXORX-XX-X; Block TX: RXBLI:MO=RXOTX-XX-X; Block TRX: RXBLI:MO=RXOTRX-XX-X; Take time slots out of service: RXESE:MO=RXOTS-XX-X-0&&-7; Take RX out of service: RXESE:MO=RXORX-XX-X; Take TX out of service: RXESE:MO=RXOTX-XX-X; Take TRX out of service: RXESE:MO=RXOTRX-XX-X; Undefine time slots: RXMOE:MO=RXOTS-XX-X-0&&-7; Undefine RX: RXMOE:MO=RXORX-XX-X; Undefine TX: RXMOE:MO=RXOTX-XX-X; Undefine TRX: RXMOE:MO=RXOTRX-XX-X; Change Cell Logial alarm set point: RLSLC:CELL=cell, CHTYPE=TCH,LVA=XX; (Set to one less than the number of channels after the TRU is removed)

GROUP SWITCH FAULTS: 1. 2. 3. 4. 5. 6. 7. GSSTP:CLM[TSM,SPM]=clm[tsm,spm]; GSBLI:CLM[TSM,SPM]=clm[tsm,spm]; GSTEI:CLM[TSM,SPM]=clm[tsm,spm]; BLEMI:RP=XX,RPT=YY,EM=Z; Replace board, use wrist strap! BLEME:RP=XX,RPT=YY,EM=Z; GSTEI:CLM[TSM,SPM]=clm[tsm,spm]; Group switch status, for CLM (or tsm or spm, depending) Block Test, get board list if faulty Block the EM controlling the TSM (or SPM or CLM)

8. GSBLE:CLM[TSM,SPM]=clm[tsm,spm]; 9. GSSTP:CLM[TSM,SPM]=clm[tsm,spm];

- Deblock the EM - Test again if no faults found go to step 8, if faulty go back to step 4 - Deblock - Verify status

TRACING GROUP SWITCH DISTURBANCES: 1. GSDSP:TSM=TSM-A(B)-XX,NORESET; 2. 3. 4. 5. NTCOP:SNTP=TSM-XX-Y; NTCOP:SNT=ETRBLT4-XX; RADRP:DEV=RBLT24-XX&-XX; EXPOP:RP=XX,EM=YY; - Print disturbances w/o resetting, look for high values on SNTPs - Print whats on that SNTP - Print devices on the SNT (gives 2 ranges for each SNTP) - Pick one device from each range, get RP&EM#s - Find the card, look for loose cables, bent pins, etc.

DELETING A SECTOR: 1. Change the sector state to HALTED: RLSTC :CELL=cell, STATE=HALTED. 2. Disconnect Transceiver Group : RXBLI:MO=RXOTS-TG-TEI-0&&-7; RXBLI:MO=RXOTX-TG-TEI&RXORX-TG-TEI&RXOTRX-TG-TEI; RXESE:MO=RXOTS-TG-TEI-0&&-7; RXESE:MO=RXOTX-TG-TEI&RXORX-TG-TEI&RXOTRX-TG-TEI; RXMOE:MO=RXOTS-TG-TEI-0&&-7; RXMOE:MO=RXOTX-TG-TEI&RXORX-TG-TEI&RXOTRX-TG-TEI; RXTCE:MO=RXOTG-TG,CELL=cell,CHGR=0; RLVLE:CELL=cell,chtype=sdcch; RLVLE:CELL=cell,chtype=tch; RLSLE:CELL=cell,perm; RLDEE:CELL=cell;

3. Disconnect Seizure Supervision: 4. Disconnect Logical Channel Supervision: 5. Delete Sector: DELETING A WHOLE SITE: 1. Change the sector state to HALTED: 2. Delete MOs:

RLSTC :CELL=cell,STATE=HALTED. (Repeat for each sector)

TRUs: RXBLI:MO=RXOTS-XX-X-0&&-7&RXORX-XX-X&RXOTX-XX-X&RXOTRX-XX-X; RXESE:MO=RXOTS-XX-X-0&&-7&RXORX-XX-X&RXOTX-XX-X&RXOTRX-XX-X; RXMOE:MO=RXOTS-XX-X-0&&-7&RXORX-XX-X&RXOTX-XX-X&RXOTRX-XX-X; (Repeat the sequence RXBLI, RXESE, RXMOE for each TRU in the site) DXU: RXBLI:MO=RXOIS-XX&RXOTF-XX&RXOCF-XX,force; RXESE:MO=RXOIS-XX&RXOTF-XX&RXOCF-XX; RXMOE:MO=RXOIS-XX&RXOTF-XX&RXOCF-XX; 3. Disconnect Tranceiver Group: RXTCE:MO=RXOTG-XX,CELL=cell,CHGR=0; (Repeat for each sector in the site) 4. Disconnect seizure supervision: RLVLE:CELL=cell,chtype=sdcch; (Repeat for each sector) 5. Disconnect sector from logical channels availability supervision: (Repeat for each sector) RLSLE:CELL=cell,perm; 6. Delete Sector: RLDEE:CELL=cell; (Repeat for each sector) 7. Disconnect TG from RBLT24 devices: RXAPE:MO=RXOTG-XX,DCP=ALL; 8. Delete TG: RXBLI:MO=RXOTG-XX,FORCE; RXESE:MO=RXOTG-XX; RXMOE:MO=RXOTG-XX; 9. Block devices: BLODI:DEV=RBLT24-XX&&-XX; 10. Block DIP: DTBLI:DIP=XXRBLT; SEIZURE SUPERVISION OF DEVICES IN BSC ALARM: 1. 2. 3. 4. Print list of busy or unused devices: RASAP: Initiate call trace on busy devices: RAPTI:DEV=RALT24-XX; Save all information from the RASAP and RAPTI commands. Clear the alarm: RASAR:DETY=RALT24;

SNT FAULTS: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Print status of SNT: NTSTP:SNT=ETRBLT4-XX; Block SNT: NTBLI:SNT=ETRBLT4-XX; Test SNT: NTBLI:SNT=ETRBLT4-XX; If no faults found go to step 13, otherwise: List of faulty boards will be printed out from step #3 Print devices for SNT: NTCOP:SNT:ETRBLT4-XX,DIPINF; Find RP and EM: Pick a device, then: RADRP:DEV=RBLT24-XX; Block EM: BLEMI:RP=XX,RPT=YY,EM=X; Change board, use wrist strap!! Deblock EM: BLEME:RP=XX,RPT=YY,EM=X; Test SNT again: NTTEI:SNT=ETRBLT4-XX; If faults found go back to step 8, put original board back, go on with next board If no faults found, deblock SNT: NTBLE:SNT=ETRBLT4-XX; Verify status: NTSTP:SNT=ETRBLT4-XX;

SNT FAULTS WHERE ONLY ONE DIP IS AFFECTED: Note: The SNT will be in ABL, with state TRAFLIM. The DIP will be ABL with FAULT=NONE. 1. Find DIPs connected to SNT: NTCOP:SNT=ETRBLT4-XX,DIPINF; 2. Status DIPs: DTSTP:DIP=XXRBLT; for all 4 dips connected to that SNT. 3. Find the RP and EM for the devices on the DIP that is ABL: RADRP:DEV=RBLT24-XX&&-XX; 4. Find the twin for the RP: EXEMP:RP=XX,EM=ALL; 5. Block the devices on the DIP: BLODI:DEV=RBLT24-XX&&-XX; 6. Block the EM: BLEMI:RP=XX,RPT=XX,EM=X; -SNT fault should clear, DIP will come up WO. 7. Deblock the EM: BLEME:RP=XX,RPT=XX,EM=X; 8. Deblock the devices: BLODE:DEV=RBLT24-XX&&-XX; SITE INTEGRATION PROCEDURE: 1. Check if data for site is in BSC: 2. RXTCP:MOTY=RXOTG,CELL=cell; 3. Check configuration of the RBLT: 4. 5. 6. 7. 8. 9. 10. 11. Get the range of devices for the site: Deblock Dip: Check Status of Dip: Check devices: Deblock the devices: Load the TG: Deblock the TG: Load the CF: RLDEP:CELL=cell; DTIDP:DIP=xxRBLT; (LC and FRS must be set to 1. If they are not, use the command DTIDC:DIP=xxRBLT,FRS=1,LC=1;) RXAPP:MO=RXOTG-XX; DTBLE:DIP=xxRBLT; DTSTP:DIP=xxRBLT; STDEP:DEV=RBLT24-xxx&&-yyy; (Use range obtained in step 3) BLODE:DEV=RBLT24-xxx&&-yyy; RXESI:MO=RXOTG-xx; RXBLE:MO=RXOTG-xx; RXESI:MO=RXOCF-xx; (This will take several minutes as the DXU loads over the T1. CF will come back in state COM MBL.) RXBLE:MO=RXOCF-xx; State=OPER RXESI:MO=RXOTF-xx&RXOIS-xx; State=COM MBL RXBLE:MO=RXOTF-xx&RXOIS-xx; State=OPER RXESI:MO=RXOTRX-xx-0; State=OPER (MO not loadable from the BSC, this is OK) RXESI:MO=RXOTX-xx-0&RXORX-xx-0&RXOTS-xx-0-0&&-7; State=COM MBL RXBLE:MO=RXOTX-xx-0&RXORX-xx-0&RXOTS-xx-0-0&&-7; State=OPER RLGSC:CELL=cell,FPDCH=1,GAMMA=30,PDCHALLOC=FIRST; RLGSI:CELL=cell; (Repeat for each sector) RLSTC:CELL=cell,STATE=ACTIVE;

12. Deblock the CF: 13. Load the TF & IS: 14. Deblock the TF & IS: 15. Load the TRX in TRU 0: 16. Load the rest of TRU 0: 17. Deblock the rest of the TRU: 18. Repeat steps 15-17 for each TRU. 19. Activate GPRS on all sectors: 20. Activate sector:

MSC Commands: SEQIP:R=XXXX;

- Print devices on the route which are causing a seizure supervision alarm SEQIR:R=XXX,[ACL=XX,QUOS=XX,QUOB=XX]; - Reconnects previously disconnected seizure supervision SEQAR:R=xxx (or dev=xxx); - Reset seizure supervision alarm on route or device STBSP:DETY=xxxx; - Shows which devices are blocked of the given type BLURE:R=xxxx; - End blocking supervision on a route BLURI:R=xxxx; - Initiate blocking supervision on a route BLURC:R=xx,lvb=xx&yy&zz,acl=xx; - Set blocking supervision levels for a route BLORI:R=xxx; - Block a route BLORE:R=xxx; - Deblock a route BLURP:R=xxx; - Print blocking supervision levels for a route BLORP; - Print blocked routes EXDEP:DEV=xxx; - Print SNT, route and CIC (misc1) for a device EXDEP:R=xxx; - Print SNT, route and CIC (misc1) for all devices on the route EXDEP:R=xxx,MISC1=misc1; - Find the device on the route with the specifiec CIC EXDRI:DEV=xxx,R=rrrO&rrrI,MISC1=misc1; - Add a device to a route (in & out) with specified CIC EXROP:R=xxx; - Print route data (including point code of destination) EXTPI:BNB=1+AREACODE+NUMBER; - Set up a test position for monitoring or call testing; EXTPE:BNB=1+AREACODE+NUMBER; - Release the test position EXTPP; - Print test positions in use MGAAR; - Clear MT FAILED AUTHENTICATION alarm MGARP:NLOG=XX(or ALL); - Print MT FAILED AUTHENTICATION log details MGCEI:CELL=XXXX,CGI=310-170-(lac)-(cellID),BSC=XXX; - Define a cell MGCEC:CELL=XXXX,EA=X,RO=Y; - Add EA and RO values to the cell MGCEP:CELL=XXXX; - Print definition of the cell MGCEP:BSC=XXXXXXX; - Print cell data for all cells in the given BSC MGCEP:LAI=310-170-XXX; - Print cell data for all cells in the given LAI MGOCP:CELL=XXXXXX; - Print Outer cell definition for the cell MGOCP:MSC=XXXXXXX; - Print Outer cell definitions for all cells in the specified MSC MGOCI:CELL=XXXX, CGI=310-170-(lac)-(cellID),MSC=XXX; - Define a outer cell MGOCE:CELL=XXXX; - Delete an outer cell MGSAR:LOG=(black, grey, unknown); - Clear MT IMEI SUPERVISION LOG FAULT alarm MGSGP:LOG=log,NLOG=ALL; - Print IMEI supervision log MGBSP:BSC=ALL; - Print all BSCs on the MSC and their associated routes MGNMP:MSC=ALL; - Print neighboring MSC list MONTI:DEV=UPDNAM-XXXX; - Monitor a Call :CON; - Connect the MONTI command after answering the test phone :END; - End MONTI command TCCCI:DEV=UPDNAM-XXXX; - Perform continuity check on a device TCTDI:DEV=UPDNAM-XX,BNB=1+areacode+num; - Force a call on the device to the B-number (must be a relevant number to that route). Your test phone will ring. Answer it, then type: :CON; This connects the call. When finished hang up or type: :END; STRDP:r=xxx; - Print list of all devices on a route STRSP:r=xxx; - Print status of route, number of devs total, in use, bloc UPCVI:DEV=UPDNAM-XXXX; - Circuit Validation Test, shows the CIC at the other end

Deciphering the EXPOP You an do an EXPOP on a RP, an EM, a DIP, or an SNT. 202 switches: <expop:rp=230; DEVICE POSITION RP POS 230 414-6-A END The position is given SUITE-CABINET-SHELF. In this example, suite (row) 414, cabinet 6, shelf A. From there youre on your own.

501 switches: <expop:rp=680; DEVICE POSITION RP POS 680 1-34-18-3-2 END The position is given FLOOR-CABINET-VERTICAL POSITION-MAGAZINE-HORIZ.POSITION. In this example, 1st floor (all of our switches will say this), cabinet 34, position 18 (use the scale on the cabinet door), magazine 3 (most will be this way), position 2 (use the horizontal scale on the magazine. Beware, the numbers refer actually to the marker to the left of the number.) Trunk Turnups 1. Obtain orders from Provisioning. Most likely you will get a phone call from Provisioning telling you who to call for testing. 2. Make note of the C-order number for each facility. This will be given on the DLR (Design Layout Report) for each circuit. This is the number PacBell uses to identify the circuits during testing of the T1s. All of the circuits in the order will have the same C order number. 3. Also make note of the system ID for each circuit, for example 110/T1/BKFDCA14DC0/BKFDCA14W02. You can reference the circuits also by the system ID. 4. Also make note of the AB numbers for the trunks, this is the number PacBell uses to identify the actual trunks (devices) in the route. It will also appear in the DLRs for the trunks. (Note: the trunk DLRs will have a system ID that says something like 0025/DF4-TFG3/BKFDCA1176T/77/BKFDCA14CM0.) The AB number will be listed under TSC on the left side of the page. It may also be on the provisioning work order in the top section on the left under TSC Code. 5. Wire the circuits as listed on the work orders. 6. Call PacBell for testing of the facilities. 7. PacBell usually puts up a loop on each T1. Monitor with your test set and have PacBell drop their loops to verify youre looking at their loop. Then run a standard 45-min. T1 acceptance test on each one. (15 min. QRSS, 5 min. All 0s, 5 min. 1:7, 5 min. all 1, 15 more min. QRSS.) You can daisy-chain the T1s and test them all at once by connecting patch cords between the out of one to the in of the next, and so on. However, if you get any errors you will have to start over and test each one individually. 8. Once the testing is complete, call PacBell and have them remove the loops and normal up the circuits. Verify optioning on each dip: DTIDP:DIP=XXUPD; For ESF/B8ZS LC and FRS should show 1. For AMI/SF LC and FRS should show 0. 9. For each circuit: Connect the device to the route: EXDRI:DEV=UPDNAM-XX&&-YY,R=XXXI&XXXO,MISC1=(tcic); (The TCIC range for the circuit will be given on the work order. Only specify the first one in the range under the MISC1 parameter, the rest will automatically follow.) Put the devices in pre-post state: EXDAI:DEV=UPDNAM-XX&&-YY; 10. Test the devices with PacBell. When they release their devices do a continuity check on a few devices on each dip: TCCCI:DEV=UPDNAM-XXXX; It should come back Successful for each one. 11. Once the devices have been tested with Bell, bring up the devices one dip at a time. Release the 1st device on the dip, wait for it to be seized, then monitor the call either with a TBERD or a MONTI command and verify good 2way audio. Then release all the rest of the devices on that dip. Call Tracing: In the MSC: 1. Initiate the trace on the phone number: CTRAI:MSISDN=(Phone number); 2. Look for the MALT device and find the route and CIC: EXDEP:DEV=MALTM-XXXX; (the number under MISC1 is the CIC, which will be the same as the RALT device in the BSC) 3. Find the BSC: MGBSP:BSC=ALL; Look for the BSC with the route specified in the EXDEP command. In the BSC: 4. Trace the RALT device: RAPTI:DEV=RALT24-XXXX; 5. Look for info on the cell site. Near the bottom of the call trace printout (branch 9) you will see the TRX. Find the cell from the TRX: RXMOP:MO=RXOTRX-XX-X; Monitoring to other MSCs: 1. Do the CTRAI command as above, look for a UPD device. (UPDNAM, UPDNA) 2. Find the route and CIC for the UPD device: EXDEP:DEV=UPDNAM-XXX; 3. Find the MSC for that route: EXROP:R=SMXXXO; The other MSC name will be given in the printout. 4. Go to the other MSC, find the device that has that CIC: EXDEP:R=SMXXXO,MISC1=(CIC); 5. Do a call trace on that device: CTRAI:DEV=UPDNAM-XXX;

AXE 810 COMMANDS TPSTP:SDIP=sdip (or ALL); TPCOP:SDIP=sdip (or ALL); TPBLE:SDIP=sdip (or ALL); TPBLI:SDIP=sdip (or ALL); TPBLI:SDIP=sdip,LP=VT15-XX; TPIDP:SDIP=sdip; GSDSP;

Print status of SDIPS Print SDIP connection data (SNT, VT to DIP, STS1) Deblock a SDIP Block a SDIP Block a VT15 on a SDIP (corresponds to a DIP) Print initial data for a SDIP Print group switch state

S-ar putea să vă placă și