PRELIMINARY
IPL 250
IP Link Ethernet Controller
68-1715-50 Rev. A 08 09
Table of Contents
Chapter One Introduction..................................................... 1-1
About this Guide........................................................................ 1-2 About the IPL 250....................................................................... 1-2 About Global Configurator..................................................... 1-3
System requirements. ............................................................ 1-4 Installing Global Configurator............................................... 1-4 Global Configurator online training. .................................... 1-5
Mounting...................................................................................... 2-5 Configuring for Network Communication......................... 2-6 Configuring the IPL250 with Global Configurator......... 2-7
All trademarks mentioned in this manual are the properties of their respective owners.
ii
IPL 250
Chapter One
Introduction
About this Guide About the IPL 250
About Global Configurator Other Software and Resources Setup Checklist: How to Proceed With Installation
Introduction
About this Guide
This setup guide describes the following items: Extron IPL 250 Extron Global Configurator software IPL 250 hardware installation IPL 250 software configuration
In this guide the IPL250 is also called "IPL," "control processor," "control interface," or "controller." Additional information about the IPL 250 and how to set it up is available on the Extron Web site (www.extron.com) in the IPL 250 Reference Manual and in the Global Configurator software's help file.
Extron IN1508
ON
n Extro
Motion Detector
LAN ER POW 12VmA 500X MA
IR Control to DVD
IR 4 3 S G
RS-232
TP UT
RS232 B
L R
AU
2 1
DIO 3
INP
UT
8 7
OU
U S I.T.E. C
TP
UT
LISTED 1T23
Y,
I
Hz 50-60 40V 100-2
N P U T
DVD Player Laptop Extron IR Emitter IR Control from IPL 250 Projector PC DVI Output
RS-232
1-2
C Use Global Configurator version 3.0 or later. Update all PCs and devices
running earlier versions of GC.
Refer also to the IPL 250 Reference Manual at www.extron.com.
1-3
Introduction, contd
System requirements
The minimum system requirements for the PC on which you install Global Configurator include: Intel Pentium III, 1 GHz processor 512 MB of RAM 50 MB of available hard disk space A network connection with a minimum data transfer rate of 10Mbps; 100Mbps is recommended. Microsoft Windows 2000 SP4, Windows XP SP2, or Windows Vista
N If ActiveX is not enabled, you may get a prompt from the browser, or you will
see the Please wait while the files are loading... message in the GlobalViewer control page. Microsoft Windows Script 5.6
4. Scroll down to the Global Configurator description and click the Install link in the far right column. 5. Follow the remaining system prompts.
1-4
To install Global Configurator from an Extron Software Products disk if Autorun is not enabled on your PC: 1. Insert the Extron Software Products disk into your drive. 2. From the Windows desktop, open My Computer and select the appropriate disk drive. 3. Double click launch.exe. 4. Wait for the Extron Software Products page to load. 5. Click on the Software icon.
6. Scroll down to the Global Configurator description and click the Install link in the far right column. 7. Follow the remaining system prompts.
Other Resources
Instructions, information, and assistance
A checklist of basic setup steps is on the next page for your reference. For additional information and step-by-step instructions, refer to the Global Configurator Help file and the IPL250 Reference Manual. If you have questions during installation and setup, you can call the Extron S3 Sales & Technical Support Hotline or the Extron S3 Control Systems Support Hotline.
1-5
Introduction, contd
Setup Checklist: How to Proceed With Installation
Preparation
Familiarize yourself with the IPL250's features. and install Extron Global Configurator software (version 3.0 or higher) Download and the latest driver package from www.extron.com or the Extron software disk. Obtain IP setting information from the network administrator for the IPL. Obtain model names and setup information for devices that the IPL will control.
Mount the unit to a rack, furniture, or projector mount. Connect the IPL to a network (LAN) and the other devices. power cords and turn on the audio/video (A/V) devices (projectors, Connect monitors, speakers), control products (such as projector lifts and screen controls),
the IPL, a PC (for setup) or touchpanel (for control after configuration). the PC to the IPL250 via Ethernet patch or crossover cable (see Connect chapter2) and use Telnet or a similar application to configure the IPL for network communication (page ). any TLP touchpanels that will be part of the system to the same Connect network as the PC and IPL. Create a user interface layout for the touchpanels and upload the GUI configuration to each touchpanel. (See the GUI Configurator software help file for details.)
Configure the IPL250 using Global Configurator. (Refer to the Global Configurator Help file.)
1-6
Create a new Global Configurator project. Set the IPLs IP address, subnet mask, and other IP settings. Define the units GlobalViewer Tree location. Add the IPL to the project. Define email settings and contacts. Add serial, IR, and Ethernet device drivers. Configure the IPLs ports and assign device drivers as needed. Configure touchpanel buttons, if applicable, in GC. Create a display shutdown schedule. Create a display lamp hours notification email. Create a display disconnection notification email. Perform configurations for special applications, if needed. Save the Global Configurator project/configuration. Build and upload the configuration.
Refer also to the IPL 250 Reference Manual at www.extron.com.
Chapter Two
Setup
Front Panel Features Rear Panel Connections and Features Mounting Configuring for Network Communication Using Global Configurator Using the GlobalViewer Interface and Testing
Setup
For your convenience, there is an installation checklist on the outside back cover.
IPL 250
1
COM
TX RX 1
IR
3
INPUT
1 3
RELAY
1 3
2 3 2 4 2 4 2 4
Reset Button (recessed): See Resetting the Unit, in the IPL 250 Reference Manual
1 4 7
2 5 8 0
3 6 9
2-2
4
COM 2 TX RX
5
IR
6
RELAY 2 1
S G S G IR RELAY 4 3
S G S G
a b
Power Connect the DC power supply here after making all other connections. Ethernet (LAN) port Connect the unit to an Ethernet network. LAN port default protocol: IPLs IP address: 192.168.254.254 Gateways IP address: 0.0.0.0 Subnet mask: 255.255.0.0 DHCP: off Link speed and duplex level: autodetected
e f
IR ports (IR) Connect IR Emitters or another device's wired IR control port here to send IR signals (with or without carrier frequencies) to display or source devices. Relay ports (Relay1, 2, 3, 4) Connect equipment here that can be controlled via momentary or latching contact. A total of 24V at 1A must not be exceeded for each port. Each relay has two sets of contacts: by default, one pair is closed, the other is open. Both contacts can be used at the same time; a total of eight sets of contacts can be used simultaneously. Use software to change the timeout period. Contact input (Input) ports Connect an optional contact closure device here. Pins 1-4 select inputs 1-4 on a connected switcher or projector; pin 5 is a ground pin. MAC address This is the unique hardware ID number.
COM 1 serial port Cable a device (such as a display) here to control it using RS232 communication. Downloaded control commands (from device drivers) can be sent from this port. COM 2 and COM 3 serial ports Connect additional devices to these ports to control them viaRS-232. Protocol can be changed via software or SIS command; speed can be set from 300 to 115200 baud. COM port (1-3) default protocol: 9600 baud 1 stop bit no parity no flow control
g h
2-3
Setup, contd
Wiring
C Installation and service must be performed by authorized personnel only.
Attach cables using the following wiring diagrams as a guide. Full details are available in the IPL250 Reference Manual.
Power
Connect the Extron 12VDC, 1.0A (max.) power supply to a as shown here:
Tie Wrap
Serial/RS-232 (c, d)
Wiring for COM3 is the same as for COM2.
COM1 TX RX RTS CTS COM 2 TX RX
Smooth Ridges
Control
Ethernet/LAN (b)
Pins: 12345678
INPUT 2 3 4
Straight-through Cable
End 1
Wire Color white-orange orange white-green blue white-blue green white-brown brown Pin 1 2 3 4 5 6 7 8
End 2
Wire Color white-orange orange white-green blue white-blue green white-brown brown
Pin 1 2 3 4 5 6 7 8
RJ-45 Connector
Crossover Cable
Pin 1 2 3 4 5 6 7 8
End 1
Pin 1 2 3 4 5 6 7 8 Wire Color white-orange orange white-green blue white-blue green white-brown brown
End 2
Wire Color white-green green white-orange blue white-blue orange white-brown brown
Transmit (Tx) Receive (Rx) Ground (GND) Request to send (RTS) Clear to send (CTS)
N You must
4 3 2 1
Switch, Sensor
2-4
S G S G
RELAY 2 1
IR Output Ground ( )
Mounting
Mount the IPL and other devices and attach cables using the preceding wiring section as a guide. Optional rack shelves and an assortment of mounting kits (such as back of the rack, furniture, and projector pole mount kits) are available for use with the IPL. Refer to the IPL250 Reference Manual for part numbers of these accessories, and read the instructions that come with the rack shelf or mounting kit for installation procedures.
2-5
Setup, contd
Configuring for Network Communication
To function together, both the PC and the IPL250 must be configured correctly. The PC must be network-capable with the proper protocols, and the IPL must be set up so it can be connected to a LAN or other network. When you power on the IPL for the first time, you have a choice of several ways to set up the IP address: Use the Global Configurator software refer to the Global Configurator Help file. Use the ARP (address resolution protocol) command see the instructions in this chapter. Use a Web browser refer to the IPL250 Reference Manual. Use SIS commands via Telnet refer to the IPL250 Reference Manual. The first time you connect a PC to an IPL via IP, you may need to temporarily change the PCs IP settings in order to communicate with the controller. That process is described in the IPL250 Reference Manual. Then you must change the controllers default settings (IP address, subnet mask, and [optional] administrator name and password) in order to use the unit on an intranet (LAN) or on the Internet. After you have set up the IPL250 for network communication, you can reset the PC to its original network configuration.
N Both the computer and the IPL must be connected to the same subnet on a
LAN (using a straight-through cable). Alternatively, you can use a crossover Ethernet cable to connect the controller directly to the computers network adapter card. Use ARP to configure the IP address as follows: 1. Obtain a valid IP address for the IPL250 from the network administrator. 2. Obtain the IPLs MAC address (UID #) from the label on its rear panel. The MAC address should have this format: 00-05-A6-xx-xx-xx. 3. If the IPL has never been configured and is still set for factory defaults, go to step 4. If not, perform a Mode 4 system reset. For detailed information on reset modes, see Resetting the Unit in the IPL250 Reference Manual.
5. Execute a ping command by entering ping followed by a space and the new IP address at the command prompt. For example: ping 10.13.197.7 You must ping the IPL250 in order for the IP address change to take place. The response should show the new IP address, as shown in the following figure.
2-6
You can reconnect using either Telnet or a Web browser to verify that the update was successful.
6. After verifying that the IP address change was successful, enter and issue the arpd command at the DOS prompt. For example: arpd 10.13.197.7 removes 10.13.197.7 from the ARP table or arpd* removes all static IP addresses from the ARP table.
The Global Configurator Help file includes an introduction to the software ("Introduction") and a section ("Getting Started") on how to start a Global Configurator project. It also features step-bystep instructions on the basic tasks involved in configuring an IPL 250. An example of the topics available in the GC help file is shown at right. Sections recommended for your reading are indicated by boxes in the figure at right. If you have questions during installation and setup, you can call the Extron S3 Sales & Technical Support Hotline or the Extron S3 Control Systems Support Hotline.
2-7
Setup, contd
2-8
Extron Warranty
Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to: USA, Canada, South America, and Central America: Extron USA 1001 East Ball Road Anaheim, CA 92805 U.S.A. Europe, Africa, and the Middle East: Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands Asia: Extron Asia 135 Joo Seng Road #04-01 PM Industrial Bldg. Singapore 368363 Singapore Japan: Extron Japan Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan China: Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Middle East: Extron Middle East Dubai Airport Free Zone F12, PO Box 293666 United Arab Emirates, Dubai
This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions or nonExtron authorized modification to the product. If it has been determined that the product is defective, please call Extron and ask for an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), 65.6383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number). This will begin the repair process as quickly as possible. Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions. Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage. Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.
Familiarize yourself with the IPL250's features. and install Extron Global Configurator software (version 3.0 or higher) and the Download latest driver package. (See chapter 1, www.extron.com, and the Extron software disk.)
Obtain IP setting information from the network administrator for the IPL. Obtain model names and setup information for devices that the IPL will control.
Mount the unit to a rack, furniture, or projector mount. Connect the IPL to a network (LAN) and the other devices. power cords and turn on the audio/video (A/V) devices (projectors, monitors, Connect speakers), control products (such as projector lifts and screen controls), the IPL,
a PC (for setup) or touchpanel (for control after configuration). the PC to the IPL250 via Ethernet patch or crossover cable (see chapter2) and use Connect Telnet or a similar application to configure the IPL for network communication (page 2-6). any TLP touchpanels that will be part of the system to the same network as Connect the PC and IPL. Create a user interface layout for the touchpanels and upload the GUI
configuration to each touchpanel. (See the GUI Configurator software help file for details.)
Configure the IPL250 using Global Configurator. (See the Global Configurator Help file.) Create a new Global Configurator project. Set the IPLs IP address, subnet mask, and other IP settings. Define the units GlobalViewer Tree location. Add the IPL to the project. Define email settings and contacts. Add serial, IR, and Ethernet device drivers. Configure the IPLs ports and assign device drivers as needed. Configure touchpanel buttons, if applicable, in GC. Create a display shutdown schedule. Create a display lamp hours notification email. Create a display disconnection notification email. Perform configurations for special applications, if needed. Save the Global Configurator project/configuration. Build and upload the configuration. Test the system.
Extron USA - West
Headquarters +800.633.9876
Inside USA / Canada Only
Extron Europe
+800.3987.6673
Inside Europe Only
Extron Asia
+800.7339.8766
Inside Asia Only
Extron Japan
+81.3.3511.7655 +81.3.3511.7656 FAX
Extron China
+400.883.1568
Inside China Only