Sunteți pe pagina 1din 7

TECHNICAL SPECIFICATIONS

FN 72 00 Retarder (FOCAL 2000)


OC442012/e 11/2000

Notes

This technical data is supplied for your guidance in the use of the product and may be modified at any moment without prior notice. Any reproduction, duplication or translation of this publication, also in the form of an abstract, is subject to the previous written permission of LABINAL, TELMA Retarders Division, Cergy. Printed in France

OC442012/e 11/2000

General specifications
Identification
Code N : FN 7200 Variant

FN 72 00

0
Coupling index (100 = without intermediary flange) Voltage index 1 = 12 V
2 = 24 V

20 : external connecting block insulated earth impregnated stator gearbox fitting 31 : external connecting block insulated earth impregnated stator drive axle fitting

Specifications
MASS RANGE of application * G.C.W. maximum TORQUE rotors INERTIA Total : 174 kg 383 lb Rotors : 67 kg 147 lb 16 / 22 metric tons 2000 Nm / 1474 lbf t 2.33 kgm 2 / 55.3 lbf t
2

Stator : 107 kg 236 lb

* for specific applications, consult our Technical Department

Curves
TORQUE 1234 : control stages
lb.ft Nm bhp kW

POWER

rpm min -1

rpm min -1

OC442012/e 11/2000

FN 72 00
connecting block (4 x M6) earth terminal (M8) 4 x 2 holes 12.8 58 126 50 45 25 526

Dimensions
min. dimension to leave clear 355

rotor outer diameter 485


0

183H7
4xM12x1.5 mm studs on PCD 204 mm (one stud with 3 offset)

intermediate flange thickness: 24.3 - 0.10

54 516
+3 +0

54

128.5 239.3 E : nominal average 0 airgap = 1.4 - 0.15 (0.049/0.055 inch)

NOTE : all the dimensions are given in millimeters 1 mm = 0.39 inch

Crosssection view
E C 1 2 3 4 5 Air-gap Rotor air-gap adjusting shims Rotor Stator Pole Pole shoe plate Connecting block

OC442012/e 11/2000

226K6

Installation
Fitting example
on gearbox (A)

FN 72 00

on drive axle (B)

1 TELMA adaptation kit (stator carrier) 2 Focal Retarder

3 Gearbox conversion kit 4 Intermediate flange (included in TELMA adaptation kit)

OC442012/e 11/2000

FN 72 00
VOLTAGE (depending on vehicle equipment) RESISTANCE per CIRCUIT at 20 C (68F) ( 5 %) RESISTANCE per COIL at 20 C (68F) ( 5 %) INSULATION RESISTANCE Average nominal AIRGAP

Electrical specifications
12 V 0 . 21 0 . 42 > 1 M 1.4
0 - 0.15

24 V 0.83

mm (0.049/0.055 inch)

12 V specifications
CURRENT CONSUMPTION (at 20 C (68 F) according to control stage) REAR SIDE

STAGE CURRENT 5% (A)

1 57.5

2 115

3 172.5

4 2 30

LAYOUT OF ONE STAGE

red sleeve

blue sleeve

24 V specifications
CURRENT CONSUMPTION (at 20 C (68 F) according to control stage) REAR SIDE

STAGE CURRENT 5% (A)

1 29

2 58

3 87

4 116

LAYOUT OF ONE STAGE

red sleeve

blue sleeve

OC442012/e 11/2000

Wiring diagram
Wiring diagram (example with hand control)

FN 72 00

Consult our Technical Department for automatic control and governing devices (ex. : ABS ...)

relaybox

dashboard light

I
1 2 3 4 5

II III IV
M 1 2 3 4 E + I II III IV S

hand control

5A

+
battery

+
+ ignition (terminal 15) or alternator (terminal 61 or D+) or ABS relay

retarder

WIRING (minimum section required)

CONNECTION
hand control / relaybox relaybox / dashboard light (terminals 1234VS) relaybox / retarder (terminals IIIIIIIV) relaybox earth (terminal M) max length par wire = 8 m (26.25 ft) retarder earth relaybox feeder (terminal +) max length par wire = 1 m (3.28 ft)

12 V mm2
AWG

24 V mm2
AWG

1 16

1 16

16 6

10 8

50 1/0

35 2

NOTE : for longer lengths, please consult our Technical Department.