Sunteți pe pagina 1din 2

3DS3R17ME-TFD

HFC , R-407A, 60Hz, 3- Phase, 460 V Air Conditioning Production Status: Available for sale to all U.S. customers. Please check with your local Emerson Climate Technologies Representative for international availability.

Performance
Evap(F)/Cond(F) RG(F)/Liq(F) Capacity (Btu/hr) Power (Watts): Current (Amps): EER (Btu/Wh): Mass Flow (lbs/hr): 45 / 130 65 / 115 35 / 105 55 / 90 Number of Cylinders: Bore Size(in): Stroke(in): 192000 17900 26.75 10.70 3050 189500 13800 21.60 13.70 2650 Suction Size (in): Sound Power (dBA): Vibration (mils(peak0 Avg 0.0 Avg 0 Max 0.0 Max Discharge Size (in): Oil Recharge (oz): Initial Oil Charge (oz): Record Date: 2010-11-23 Net Weight (lbs): 3 2.44 2.50

Mechanical
Displ(in^3/Rev): Displ(ft^3/hr): 35.01 2127.41

Overall Length (in): 28.03 Overall Width (in): Overall Height (in): 15.06 18.03

Mounting Length (in): Mounting Width (in): Mounting Height (in):

15.00 12.00 19.06

1 5/8 Sweat 1 1/8 Sweat 115 125 385

Internal Free Volume (in^3): Horse Power: 15 *Overall compressor height on Copeland Brand Product's specified mounting grommets.

Electrical
LRA-High*: LRA-Half Winding: LRA Low*: RLA(=MCC/1.4;use for contactor selection): RLA(=MCC/1.56;use for breaker & wire size 138.0 MCC (Amps): RPM: Max Operating Current: 29 26 40.6 0 UL File No: UL File Date: SA-2337 26-Jul-1985

*Low and High refer to the low and high nominal voltage ranges for which the motor is approved.

Alternate Applications
Refrigerant
R-22 HCFC R-22 HCFC R-404A HFC R-407A HFC R-407A HFC R-407C HFC R-407C HFC R-407C HFC R-502 CFC R-507 HFC R-22 HCFC Oziel Onofre Vargas 01/25/2011

Freq (Hz)
60 60 60 60 60 60 60 60 60 60 50

Phase
3 3 3 3 3 3 3 3 3 3 3 Page 1 Of 2

Voltage
460 460 460 460 460 460 460 460 460 460 380/420

Application
Air Conditioning Medium Temp, Low Condensing Medium Temp, Low Condensing

Medium Temp, Low Condensing

Air Conditioning Medium Temp, Low Condensing

Medium Temp, Low Condensing Air Conditioning

Copyright 2010 Emerson Climate Technologies, Inc. All rights reserved.

Alternate Applications
Refrigerant
R-22 HCFC R-404A HFC R-407A HFC R-407A HFC R-407C HFC R-407C HFC R-502 CFC R-507 HFC

Freq (Hz)
50 50 50 50 50 50 50 50

Phase
3 3 3 3 3 3 3 3

Voltage
380/420 380/420 380/420 380/420 380/420 380/420 380/420 380/420

Application
Medium Temp, Low Condensing Medium Temp, Low Condensing

Medium Temp, Low Condensing

Oziel Onofre Vargas 01/25/2011

Page 2 Of

Copyright 2010 Emerson Climate Technologies, Inc. All rights reserved.