AC: 24, 48, 110, 120, 230 V DC: 24 V 85 ... 110 % 10 % Approx. 3.5 VA/4 W
Delay-on energisation timer relay in accordance with VDE 0113-1, 11/98, EN 60204-1, 12/97, EN 1088, 12/97 and IEC 204-1, 11/98.
Approvals PZA
AC1: 240 V/6 A/1500 VA DC1: 24 V/6 A/150 W EN 60947-5-1, 11/97 (DC13: 6 cycles/min.) AC15: 230 V/4 A; DC13: 24 V/3A Output Contacts 1 safety contact (N/O), 2 auxiliary contacts (N/C) Contact Fuse Protection 6 A quick or 4 A slow (EN 60947-5-1, 08/00) Times Delay-on De-energisation Approx. 40 ms Recovery Time 80 ms Time Ranges PZA 30 s: 3/4/5/7/9/12/15/18/21/24/27/30 s PZA 300 s : 30/40/50/70/90/120/150/180/210/240/ 270/300 s Setting Accuracy Start of the range 5% End of the range 2% Time Accuracy 1 % voltage change 0.06 % 1 C temperature change 0.06 % Repetition Accuracy 1 % Mechanical Data Maximum Cross Section of 1 x 2.5 mm 2 or 2 x 1.5 mm2 External Conductors Single-core or multi-core with crimp connectors Dimensions (H x W x D) 87 x 45 x 121 mm Weight AC: 350 g, DC: 260 g
Description 45 mm, P-93 housing, DIN-Rail mounting Positive-guided relay outputs: 1 safety contact (N/O) 2 auxiliary contacts (N/C) LEDs for power and out 12 time-delay options, set via a rotary switch Increase in the number of safety contacts availableby connecting expander modules.
Function Description The PZA provides a delayed release of a shotbolt, activated by applying the operating voltage.
Pilz GmbH & Co., Felix-Wankel-Strae 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-084-01/02
Power Section
Time circuit 1
K1
K1
K1
K1
K2 Comparator level
K2
K2
K2
K1
18
26 36
Connection Example If the start/reset button is pressed while the safety gate is closed, the PZA de-energises. The safety gate can not be opened. By pressing the stop button, the relay K1 deenergises and the N/C contact K1 closes. After the set time period has elapsed the safety contact of the PZA closes. The safety gate switch is released and the safety gate can be opened by operating the switch open.
L1
F1 K1
A1 17 25 35 Y1 Y2 PZA
18 26 36
A2
Open
Reset / Start
K1
Stop K1 N
Pilz GmbH & Co., Felix-Wankel-Strae 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-084-01/02
4-2
50 ... 60 Hz 160 % AgSnO2 100 % EN 50081-1, 01/92, EN 61000-6-2, 03/00 Frequency: 10 ... 55 Hz, Amplitude: 0.35 mm DIN IEC 60068-2-3, 12/86 DIN VDE 0110 part 1, 04/97 -10 ... +55 C -40 ... +85 C 0.6 Nm (screws) Any Thermoplast Noryl SE 100 Mounting: IP 54 Housing: IP 40 Terminal Range: IP 20
The units were tested in accordance with the relevant standards current at the time of development.
Order References Type PZA PZA PZA PZA PZA PZA t 30 30 30 30 30 30 UB 24 V DC 24 V AC 48 V AC 110 V AC 120 V AC 230 V AC Order No. 774 030 774 031 774 032 774 035 774 037 774 040
s s s s s s
Pilz GmbH & Co., Felix-Wankel-Strae 2, 73760 Ostfildern, Deutschland Telefon +49 (7 11) 34 09-0, Telefax +49 (7 11) 34 09-1 33, E-Mail: pilz.gmbh@pilz.de
NSG-D-2-084-01/02