DOOSAN PROJECTS INDIA PVT.

,
W.O. No: T10107 Prepared By: Title: JL Calc No: Date: 2011/1/18 Sheet No: Checked By: CJP Cont'd on: Date: 2011/1/20

2 x 685 MW RAIPUR - CHHATTISGARH Coal Fired Power Plant - Primary Air Fan Foundation

DYNAMIC RESPONSES FOR COUPLED ANALYSIS


A coupled analysis was performed using STAAD.Pro finite element computer program. The PA Fan Foundation was modeled, allong with all static and dynamic loads applied as per vendor drawing T10107YD00-P0HLB-310002. The foundation rests directly g Foundation Mat. on the Boiler Building After preliminary analyses, it was determined that the use of a neoprene pad would greatly increase the response of the foundation due to its relatively low stiffness compared to the bearing material below. For this reason, the noeprene pads were removed from the model and their use is strongly discouraged. The fi l model final d l without ih these h pads d shows h much hl lower displacements and velocities. The responses to this coupled dynamic analysis are presented below:

NATURAL FREQUENCIES The following natural frequencies were computed by the STAAD analysis:

Modes
1 Sliding in Z-Axis 2 Sliding in X-Axis 3 Torsion about Y-Axis 4 Vertical Vibration 5 Rocking About Z-Axis 6 Rocking About X-Axis 7+ High Frequency Modes

Operating Frequency for PA Fan = 24.8 Hz 0 7fn = 17.4 0.7f Exclusion Zones: 17 4 Hz to 2 x (0.8fn) = 39.7 Hz to

1.3f 1 3fn = 32 32.2 2 Hz 2 x (1.2fn) = 59.5 Hz

NONE OF THE FREQUENCIES CALCULATED FALL WITHIN THE EXCLUSION RANGE - OK

VENDOR ACCEPTANCE CRITERIA - VELOCITY AND DISPLACMENT


Per ISO 10816/3, max veloctiy at fan bearing (anti-friction type) = 2.3 mm/sec Per ISO 7919-3, max displacement at motor bearing (sleeve type) = 124.0 m (RMS, commisioning phase) (peak to peak, commisioning phase)

0.124 mm

DOOSAN PROJECTS INDIA PVT.,


W.O. No: T10107 Prepared By: Title: JL Calc No: Date: 2011/1/18 Sheet No: Checked By: CJP Cont'd on: Date: 2011/1/20

2 x 685 MW RAIPUR - CHHATTISGARH Coal Fired Power Plant - Primary Air Fan Foundation

DYNAMIC RESPONSES FOR COUPLED ANALYSIS


DYNAMIC VELOCITY RESPONSE @ FAN CL - NODE 901:

x =

0.08 mm/sec (Steady State) x(rms) = 0.06 mm/sec

y =

0.22 mm/sec (Steady State) y(rms) = 0.16 mm/sec

z =

1.20 mm/sec (Steady State) z(rms) = 0.85 mm/sec

All of these responses are less than the allowable velocity = 2.3 mm/sec

OK

DYNAMIC DISPLACEMENT RESPONSE @ MOTOR NODE 899:

x = 0.001 mm (Peak to Peak) (Steady State)

y = 0.003 mm (Peak to Peak) (Steady State)

z = 0.020 mm (Peak to Peak) (Steady State)

All of these responses are less than the allowable displacement =

0.12 mm

OK