Item

Description WORK BELOW LOWEST FLOOR FINISH EXCAVATION AND EARTHWORK EXCAVATION Excavating to reduce level; commencing from formation level; cart away, deposit, spread and level where directed within the site

Unit

Quantity

Rate

Amount

Maximum depth not exceeding 1.00m Excavating trenches starting from reduced level; including backfill with approved excavated material, compaction in layers and disposal of surplus excavated material where directed within the site To receive strip foundation

M3

54

Maximum depth not exceeding 1.00m To receive ground beams

M3

Maximum depth not exceeding 1.00m FILLING Hardcore as specified

M3

25

D E

To make up levels not exceeding 250mm thick; average 150mm thick To receive strip footings CONCRETE WORK IN-SITU CONCRETE Plain Concrete Grade 7 as specified; blinding screed; laid on earth or Under strip footings

M2 M2

154 1

Not exceeding 100mm thick Under ground beam

M3

Not exceeding 100mm thick Under ground floors slab

M3

Not exceeding 100mm thick Reinforced Concrete Grade 30 as specified Foundations or the likes;

M3

J K

In strip footings In column stumps Ground Beams or the likes;

M3 M3

1 3

In ground beams Bed and Ground Floor Slab or the likes; In ground floor slab

M3

21

100mm - 150mm Thick

M3

23 To Collection

Item

Description WORK BELOW LOWEST FLOOR FINISH (Contd) CONCRETE WORK (Contd) Reinforcement bars; hot rolled plain round mild steel Foundations or the likes; In strip footings

Unit

Quantity

Rate

Amount

10mm Diameter; straight and bent In column stumps

KG

56

10mm Diameter; links or the likes Ground beams or the likes; In ground beams

KG

90

10mm Diameter; stirrups or the likes Reinforcement bars; hot rolled deformed high tensile steel Foundations or the likes; In column stumps

KG

770

D E

16mm Diameter; straight and bent 25mm Diameter; straight and bent Ground beams or the likes; In ground beams

KG KG

191 535

F G H

16mm Diameter; straight and bent 20mm Diameter; straight and bent 25mm Diameter; straight and bent Reinforcement; fabric; Slab or the likes hard drawn plain round steel, welded as

KG KG KG

561 1393 560

In ground floor slab; Reference A193 Class F1 formwork as specified Foundations or the likes To sides of strip footings

M2

309

K L

250mm - 500mm High To sides of column stumps Ground beams or the likes To edges and faces ground beams

M M2

2 44

250mm - 500mm High WATERPROOFING AND ASPHALT WORK DAMP PROOFING AND TANKING Damp Proof Membrane as specified Coverings; 1 layer of Polythene sheet as specified, 0.125mm thick; laid

169

Over 300mm wide; flat; subsequently covered

M2

154 To Collection

Item Collection

Description

Unit

Quantity

Rate

Amount

WORK BELOW LOWEST FLOOR FINISH B1/1 B1/2

To Summary

Item

Description RAMPS, APRON AND PERIMETER DRAINS EXCAVATION AND EARTHWORK EXCAVATION Excavating to reduce level; to formation level; commencing from ground

Unit

Quantity

Rate

Amount

Maximum depth not exceeding 1.00m FILLING Hardcore as specified To make up levels not exceeding 250mm thick; average 150mm thick

M3

23

To receive apron slab CONCRETE WORK IN-SITU CONCRETE Plain Concrete Grade 7 as specified; blinding screed; laid on earth or Under apron slab

M2

76

Not exceeding 100mm thick Reinforced Concrete Grade 30 as specified Slabs or the likes; In apron slab

M3

100mm - 150mm Thick Reinforcement; fabric; Slab or the likes hard drawn plain round steel, welded as

M3

11

In apron slab; Reference A193 DRAINAGE DRAINS PERIMETER DRAIN 230mm insitu concrete as specified glazed ware half round perimeter drain, cast in suitable length, finished fair on exposed surfaces, bedded, jointed and pointed in cement mortar (1:3) on and including 50mm thick sand bedding, 450mm x 100mm thick reinforced concerete bed and concrete haunching, raised both sides with 100mm thick reinforced concrete wall rebated edge to receive 75mm thick reinforced concrete plank including non-woven geotextile or equivalent filter cloth, 100mm thick layer of single size 25 coarse aggregate and 100mm thick layer of well graded river pebbles 25 to 50 grain size and all necessary excavation, formwork, junctions and ends and remove surplus excavated materials as per drawing no HQA (98) A208 / C6 (SBH)/

M2

152

Average invert not exceeding 600mm deep ( Provisional)

71

To Summary

Item FRAME CONCRETE WORK IN-SITU CONCRETE

Description

Unit

Quantity

Rate

Amount

Reinforced Concrete Grade 30 as specified Columns or the likes; A In columns Beams or the likes; B C In floor beams In roof beams Reinforcement bars; hot rolled plain round mild steel Columns or the likes; In columns D 10mm Diameter; links or the likes Beams or the likes; In floor beams E 10mm Diameter; links or the likes In roof beams F 10mm Diameter; links or the likes Reinforcement bars; hot rolled deformed high tensile steel Columns or the likes; In columns G H J 16mm Diameter; straight and bent 20mm Diameter; straight and bent 25mm Diameter; straight and bent Beams or the likes; In floor beams K L M 16mm Diameter; straight and bent 20mm Diameter; straight and bent 25mm Diameter; straight and bent In roof beams N P Q 16mm Diameter; straight and bent 20mm Diameter; straight and bent 25mm Diameter; straight and bent KG KG KG 511 750 1247 To Collection 0 KG KG KG 502 1565 244 KG KG KG 196 699 1221 KG 501 KG 965 KG 490 M3 M3 15 13 M3 6

Item FRAME (Contd) CONCRETE WORK (Contd)

Description

Unit

Quantity

Rate

Amount

Class F1 formwork as specified Columns or the likes A To sides of columns Beams or the likes To sides and soffits of floor beams B Horizontal To sides and soffits of roof beams C D Horizontal Sloping over 15 degree from horizontal M2 M2 157 8 M2 184 M2 127

To Collection

Item Collection FRAME

Description

Unit

Quantity

Rate

Amount

B1/5 B1/6

To Summary

Item UPPER FLOOR CONCRETE WORK IN-SITU CONCRETE

Description

Unit

Quantity

Rate

Amount

Reinforced Concrete Grade 30 as specified Slabs or the likes; In floor slab A 150mm - 300mm Thick Reinforcement bars; hot rolled deformed high tensile steel Slabs or the likes In floor slab B 12mm Diameter; straight and bent Class F1 formwork as specified Slabs or the likes To soffits of floor slab C Horizontal PRECAST CONCRETE Notes; The tenderer shall have deemed to have studied the drawing/specification and visited the site to determine the extent and/or nature of pre casting, transportation, double handling, hoisting, hoisting equipments, fixing, etc. No claims will not be entertained on the ground of ignorance of extent and/or nature of such works as he is deemed to If in the opinion of the tenderer, the precast panels may be cast into smaller/bigger units, he should seek for clarification and approval from the S. O. All costs in connection with any amendments to the precast The tenderer shall note that all unplastered surfaces to precast concrete shall be finished smooth.He shall allow for this in his prices accordingly. Rates to include casting in conduits, forming chases and openings etc. for mechanical and electrical installation. It is the tenderer's responsibility to check the extent of this work from the Mechanical and Precast concrete slab Precast concrete ; BS 5750,reinforced at contractor's discrection; to approval all as per drawing no.IP(SD 900mm x 2100mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished 900mm x 3000mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished 900mm x 3600mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished M2 12 KG 251 M3 2

xx

xx

xx

xx

NR

NR

NR

1 To Collection 0

Item UPPER FLOOR (Contd) CONCRETE WORK (Contd) A

Description

Unit

Quantity

Rate

Amount

1200mm x 1500mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished 1200mm x 2100mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished 1200mm x 2100mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished 1200mm x 2200mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished 1200mm x 3000mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished 1200mm x 3600mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished 1200mm x 4200mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished 2100mm x 1500mm x 175mm Thick reinforced with lattice girder and main bar complete with bracket, sealer, peripheral ties and fair finished

NR

NR

NR

NR

NR

NR

10

NR

NR

To Collection

Item Collection UPPER FLOOR

Description

Unit

Quantity

Rate

Amount

B1/8 B1/9

To Summary

Item ROOF CONCRETE WORK IN-SITU CONCRETE

Description

Unit

Quantity

Rate

Amount

Reinforced Concrete Grade 30 as specified Slabs or the likes; In upper floor slab A 100mm - 150mm Thick gutter slab including all necessary formwork and In roof slab B 100mm - 150mm Thick In plinth C 4200mm x 200mm x 450mm Thick plinth slab including all necessary reinforcement and formwork all as per drawing NoIP(SReinforcement bars; hot rolled plain round mild steel Slabs or the likes In roof slab D 12mm Diameter; straight and bent Class F1 formwork as specified Slabs or the likes To soffits of roof slab E Horizontal ROOFING SLATE OR TILE ROOFING Roofing; concrete interlocking tiles as specified; fixing every fifth course with two aluminium alloy nails per tile to 75mm lap; 38mm x 25mm pressure treated Group 'B' timber battens fixed with galvanised nails Coverings F Sloping, pitch 32 degrees EXTRA OVER 30 degrees pitch coverings for G Ridge tiles; bedded and jointed in cement mortar (1:3) EXTRA OVER 32 degrees pitch coverings for H J Hip tiles; bedded and jointed in cement mortar (1:3) Fair ends; bedded and jointed in cement mortar (1:3) Underlay K Double sided aluminium foil insulation as specified; lapped 150mm at M2 335 To Collection 0 M NO 50 12 M 26 M2 335 M2 24 KG 998 M3 4 M3 4

NO

Item ROOF (Contd) ROOFING (Contd)

Description

Unit

Quantity

Rate

Amount

Flashings; zinc sheet as specified SHEET METAL FLASHINGS AND GUTTERS Valley tray; zinc sheet as specified 20 Gauge linings to valley tray; fixing with zinc clips A 600mm Girth No. 8 gauge flashings; 150mm lapped joints; fixing with matching clips B C 300mm Girth; one ends dressed over roof covering; other ends fixed to 300mm Girth; one ends dressed over roof covering; other ends fixed to WOODWORK CARCASSING ITEMS Wrot pressure treated Group `B' timber as specified Strutting C D 50mm x 50mm Timber support; including all necessary plate, bolt and 100mm x 50mm Timber support; including all necessary plate, bolt and BOARDING AND FLOORING Wrot pressure treated Group `B' timber as specified Boarding to eaves, verges, fascias or the like E 200mm thick x 20mm wide board COMPOSITE ITEM Sawn pressure treated Group `B' timber as specified Roof trusses The Contractor shall submit with his Tender Preliminary Design Proposals for the proprietary trusses system duly certified by the manufacturer approved by the Government, together with all other The proposed design shall be approved by the S.O. prior to fabrication and installation on site. The S.O. reserves the right to make any changes/amendments to the proposed design. Any such F M 150 M M 14 59 M M 45 32 M 38

xx

xx

`PATENTED' Roof trusses for pitch roof with and including all necessary supports as indicated based on relevant drawings and as specified, overall area approximately 290m2 (measured flat on plan) including design, built, supply, erection and fixing in position of trusses ITEM Wrot pressure treated Group `B' timber as specified gable end

Fixed louvred vent including framing and finished complete overall size 1000 mm x 600 mm as per Drawing No HQA(98)A208/ C6 (SBH) / BG2 Fixed louvred vent including framing and finished complete overall size 1400 mm x 900 mm as per Drawing No HQA(98)A208/ C6 (SBH) / 7

NO

NO

To Collection

Item ROOF (Contd) WOODWORK (Contd)

Description

Unit

Quantity

Rate

Amount

PLUMBING AND MECHANICAL ENGINEERING INSTALLATIONS RAINWATER INSTALLATION; GUTTERWORK uPVC box gutters and fittings; push fit connector joints; gutterwork and supports self coloured grey as specified 300 mm x 200mm; joints in the running length; supports at average A In standard fascia brackets fixed with galvanized screws to timber RAINWATER INSTALLATION; PIPEWORK uPVC pipes and fittings; push fit joints; pipework and supports self coloured grey as specified; externally 100 Diameter pipework; joints in the running length B In standard bracket including all necessary fixings fixed to wall or column 100mm Diameter pipework; joints in the running length C D EXTRA OVER for swan neck EXTRA OVER for bend 100 pipework; joints in the running length; embedded in the concrete or E Laid in position Sundries Balloon grating to suit and set on top of rainwater pipe F 100mm Diameter PAINTING AND DECORATING NEW WORK Woodwork Knot and stop, prime and enamel paint as specified G H General surfaces of timber; 150mm - 300mm Girth On surfaces of timber frame; 150mm - 300mm girth M M 150 73 NO 10 M 15 NO NO 10 20 M 54 M 66

To Collection

Item Collection ROOF

Description

Unit

Quantity

Rate

Amount

B1/11 B1/12 B1/13

To Summary

Item STAIRS CONCRETE WORK IN-SITU CONCRETE

Description

Unit

Quantity

Rate

Amount

Reinforced Concrete Grade 30 as specified Staircase A In steps and staircase Reinforcement bars; hot rolled plain round mild steel Staircase or the likes; In steps and staircase B 10mm Diameter; straight and bent Reinforcement bars; hot rolled deformed high tensile steel Staircase or the likes; In steps and staircase C D E 12mm Diameter; straight and bent 16mm Diameter; straight and bent 20mm Diameter; straight and bent Class F1 formwork as specified Staircase or the likes To soffits of staircases F Sloping over 15 degree from horizontal To soffits of landing slab G Horizontal To sides and soffits of landing beam H Horizontal To riser of staircase J Not exceeding 250mm wide To edges of landing slab K Not exceeding 250mm wide To edges of staircase flights L Maximum width 250mm M 11 M 11 M 24 M2 2 M2 4 M2 6 KG KG KG 15 490 12 KG 14 M3 3

To Collection

Item STAIRS (Contd) METALWORK

Description

Unit

Quantity

Rate

Amount

BALUSTRADES & STAIRCASES Mild steel in welded joints as specified Decorative railing comprising of 50mm Diameter x 3.2mm thick mild steel handrail (measured separately), 20mm x 20mm x 3.2mm thick RHS top and bottom rail; both end welded to 50mm x 20mm x 3.2mm thick RHS column post at 584mm centres; infilled with 3.2mm x 20mm thick m.s plate and 12mm x 3.2mm m.s. plate; welded all members together and including all finish with a layer of anti-rust and two coats of gloss enamel paint as specified to S.O's approval as per drawing no. HQ (98)KK(TG)3 3 d 3 4 A 1020mm High mild steel railing Type ST2 Handrails B 50mm Diameter x 3.2mm thick in welded joints as per drawing No. HQA(98)A208/C6(SBH)/TG2 EXTRA OVER for quadrant FLOOR, WALL AND CEILING FINISHINGS STAIRCASE AREA Tiled Work 'Kempas' timber strip, 50mm x 10mm timber strip with and approved adhesive on and including 20mm thick cement and sand (1:3) screeded D Landing slab; level, falls and crossfalls and to slope not exceeding 15 degrees from horizontal Riser; 160mm high Tread; 260mm wide 100mm high timber skirting on concrete base with top rounded edge PAINTING AND DECORATING NEW WORK Staircase Finishes Emulsion paint as specified H J K L To soffit of landing slab To sloping soffit of staircase To sides of raking open string To sides and soffit of landing beams Prepare and apply two coats varnish as specified M N On general surfaces of timber; 0mm - 150mm girth On general surfaces of timber; over 300mm girth M M2 13 4 To Collection 0 M2 M2 M M2 4 6 11 2 M 4

M NO

8 1

M2 M M M

4 24 22 13

E F G

Item Collection STAIRS

Description

Unit

Quantity

Rate

Amount

B1/15 B1/16

To Summary

Item

Description EXTERNAL WALLS AND BALUSTRADING CONCRETE WORK PRECAST CONCRETE Precast concrete; standard or stock pattern units Decorative capping

Unit

Quantity

Rate

Amount

75mm x 50mm Overall size approved 'GRC' capping including necessary painting all as per drawing no. HQ(98)KK(TG)1-4 250mm x 75mm Overall size approved 'GRC' capping including necessary painting all as per drawing no. HQ(98)KK(TG)1-4 BRICKWORK AND BLOCKWORK LOAD BEARING SUPERSTRUCTURE Common bricks as specified; in cement mortar (1:3) Walls

14

Half brick thick; stretcher bond Damp proof course as specified; 100 laps; bedding in cement mortar (1:6); no allowance in measurement for laps On horizontal surfaces

M2

264

115mm Wide NON-LOAD BEARING SUPERSTRUCTURE Aerated concrete blocks as specified; in cement mortar (1:3); stretcher Walls or partitions

68

150mm Thick METALWORK RAILING Mild steel in welded joints as specified Railing comprising of 50mm x 40mm x 3.2mm thick RHS handrail, 20mm x 20mm x 3.2mm thick RHS top and bottom rail; both end welded to 20mm x 20mm x 3.2mm thick RHS vertical post, 20mm x 3.2mm thick plates as vertical and horizontal intermediate rails welded all members together and including all finish with a layer of anti-rust and two coats of gloss enamel paint as specified to S.O's approval and as per Architectural drawing no. HQ (98)KK(TG) 1-1, HQ (98)KK(TG) 1-3 and HQ (98)KK(TG) 1 4 1200mm x 1100mm high overall size mild steel railing Type ST2 GLAZING GLASS BLOCKS Glass block, 190mm x 190mm x 80mm as specified, jointing in white coloured cement mortar (1:6); flush smooth pointing as work proceeds; work designed to be built without cutting blocks As per drawing No HQA Walls or partitions

M2

NO

20mm Thick; finishing fair and pointing each side

M2

To Summary

Item

Description WINDOWS, VENTS AND EXTERNAL DOORS CONCRETE WORK PRECAST CONCRETE Precast concrete lintel

Unit

Quantity

Rate

Amount

150mm x 115mm Precast concrete Grade 30 as specified lintel; reinforced with and including 4 nos. 12mm Diameter high tensile bars and 6mm diameter mild steel stirrups; fair finish all faces WOODWORK UNFRAMED FIXING Sawn pressure treated Group `B' timber as specified Window beads, nosings, or the likes

47

75mm x 13mm Wrot pressure treated Group `B' timber as specified Framework to brick walls; to receive door finish

11

150mm x 50mm hardwood frame Architrave, cover fillets or the likes

11

75mm x 15mm; splays Stops

224

50mm x 18mm COMPOSITE ITEM Wrot pressure treated Group `B' timber as specified Flush door

11

900mm x 2100mm x 40mm thick door (Type P4) comprising of 100mm x 30mm stiles, rails; covered both sides with 4mm thick plywood, and lipped all around with twice rebated edging.As per drawing No HQA (98) 900mm x 2100mm x 40mm Thick door (Type P5) comprising of 100mm x 30mm top rail, 50mm x 18mm intermediate frame, 150mm x 30mm bottom rail and 100mm x 30mm side frame; 50mm x 18mm nogging, 12mm thick fixed louvres size 350mm x 500mm including 20mm 40mm framing all round and 12mm beading and covered with 4mm thick plywood lining on both sides, and lipped all around with twice rebated Q( ) ( ) O Panelled door 900mm x 2100mm x 50mm thick decorative door in 8 panel (Type P3) (framing and ironmongeries measured separately) all as per drawing NoHQA (98) A208 / C6 (SBH) / PT1a 1500mm x 2100mm x 50mm thick decorative door in 16 panel (Type P1) (framing and ironmongeries measured separately) all as per drawing NoHQA (98) A208 / C6 (SBH) / PT1a IRONMONGERY Ironmongery or other equal and approved; to timber or concrete including providing requisite matching screws Knobset

NO

NO

NO

NO

'Yale NVCA 5057-H30-US3' or approved equivalent decorative Entrance

NO

1 To Collection 0

Item

Description WINDOWS, VENTS AND EXTERNAL DOORS (Contd) WOODWORK (Contd)

Unit

Quantity

Rate

Amount

'NEMEF H30349/715/760' or approved equivalent mortise body complete with KTT and lever handle 'TREX RC 607 - H30 - 70mm or approved equivalent SSF Knobset 'YALE ANSI Grade 3 CA5237-H30-70' or approved equivalent SSF 'TREX H30' or approved equivalent 150mm x 25mm Stainless steel 'TREX H30' or approved equivalent 300mm x 25mm Stainless steel 'YALE 373 x H30 x 374' or approved equivalent rebatted set 'YALE 180 degrees - H30 - Eye Viewer US3 Finish' or approved Hinges

NO NO NO NO NO NO NO

1 1 1 1 1 1 1

B C D E F G

102mm x 76mm x 2.0mm 'TREX PB H30' or approved equivalent plain bearing stainless steel hinges Door closer/stopper

NO

12

J K

TREX H30, 38mm rubber stopper YALE H30, Door Guard US3 finish METALWORK METAL WORKS IN STEEL HOLLOW SECTION, B.S.4848; PT.2 Mild Steel Grilles Mild steel sliding door grille comprising of 30mm x 30mm x 30mm L mild steel angle framing; 30mm x 30mm mild steel hollow section rib anchored to wall panel all welded together complete with `Henderson marathonr' or equivalent sliding grille gear set and complete with flush

NO NO

5 3

2550mm x 2100mm High; Type GP8a Mild steel grille comprising of 12mm x 12mm x 6mm thick mild steel hollow section framing and filled with 12mm x 4mm thick plat and set dioganally all welded together equivalent lock-set all as per

NO

M N

900mm x 2100mm High; Type GP4 1500mm x 2100mm High; Type GP1 Mild steel grille comprising of 12mm x 12mm x 6mm thick mild steel hollow section framing and filled with 12mm x 4mm thick plat and set dioganally all welded together as per manufacturer's detail

NO NO

2 1

P Q R S

600mm x 1.2mm High; Type GTA1 600mm x 600mm High; Type GTA14 1200mm x 600mm High; Type GTA15 1200mm x 1050mm High; Type GTA11

NO NO NO NO

1 4 1 1

To Collection

Item

Description WINDOWS, VENTS AND EXTERNAL DOORS (Contd) METALWORK (Contd)

Unit

Quantity

Rate

Amount

A B C

1200mm x 1200mm High; Type GTA2 1800mm x 1200mm High; Type GTA3 2400mm x 1200mm High; Type GTA4 DOORS Mild Steel door frame to manufacturer's detail

NO NO NO

4 3 1

320mm Girth; including fixed to wall and lintol Aluminium; natural anodised finish as specified Sliding door consisting of frame, top and bottom track factory infilled with 6mm thick float glass, weatherstrip woolpile and all necessary painting all as per manufacturer's detail and as per drawing no.

112

2400mm x 2100mm high (Type P8a) double leaf door WINDOWS Aluminium; natural anodised finish as specified Casement

NO

600mm x 600mm top hung window Type TA14 consisting of top hung panel each size 600mm x 600mm high; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer 1200mm x 600mm top hung window Type TA15 consisting of top hung panel each size 600mm x 600mm high; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer 1200mm x 1500mm composite window Type TA11a consisting of fix louvered panel at top and side hung window each size 600mm x 950mm; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer and latch set and all 1200mm x 1650mm composite window Type TA7 consisting of fix louvered panel at top and side hung window each size 600mm x 1100mm; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer and latch set and all 1800mm x 1650mm composite window Type TA8 consisting of fix louvered panel at top and side hung window each size 600mm x 1100mm; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer and latch set and all 1200mm x 1650mm composite window Type TA7b consisting of fixed louvre panel at bottom and side hung window each size 600mm x 1100mm; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer and latch set and all

NO

NO

NO

NO

NO

NO

To Collection

Item

Description WINDOWS, VENTS AND EXTERNAL DOORS (Contd) METALWORK (Contd)

Unit

Quantity

Rate

Amount

1800mm x 1650mm composite window Type TA8b consisting of fixed louvre panel at bottom and side hung window each size 600mm x 1100mm; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer and latch set and all 600mm x 1200mm side hung window Type TA1 each size 600mm x 1200mm; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer and latch set and all 2400mm x 1200mm side hung window Type TA16 each size 600mm x 1200mm; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer and latch set and all 1200mm x 3700mm composite window consisting of 4 nos. top hung panel each size 600mm x 900mm high and 4 nos. fix glass panel each size 600mm x 925mm; coupling mullion, assembling; fixing by bolting; fixing with screws complete with matching restrainer and latch set and all necessary accessories all as per drawing no. Supply and install complete approved louvred window complete with frame, head, sills, mullion, transome, rustproofed fixing brackets, back PVC infill strip and accessories and including hoisting , placing panel unit into position, plugging and screwing, fixing brackets to brickwork or concrete, bedding and filling in back of frame with waterproof cement mortar (1:3) and pointing joints with sealants and fixing all in accordance t th f t ' i t ti d h d d t il d i

NO

NO

NO

NO

Fixed louvred window overall size 600mm wide x 600mm high with and including approved anti-vermin netting fixed on internal face (Type TR4) Fixed louvred window overall size 1500mm wide x 600mm high with and including approved anti-vermin netting fixed on internal face (Type TR5) GLAZING WINDOWS, VENTS AND EXTERNAL DOORS Clear float glass as specified 6mm Thick glass fixed to aluminium frame with and including glazing strip and silicon topping

NO

NO

G H

0.1m2 - 0.5m2 0.5m2 - 1m2 PAINTING AND DECORATING NEW WORK Woodwork Knot and stop, prime and enamel paint as specified

M2 M2

7 20

J K

On surfaces of timber frame; 0mm - 150mm girth On surfaces of timber frame; 150mm - 300mm girth

M M

224 11

To Collection

Item

Description WINDOWS, VENTS AND EXTERNAL DOORS (Contd) PAINTING AND DECORATING (Contd)

Unit

Quantity

Rate

Amount

On surfaces of door ; over 300mm girth Varnish as specified

M2

On surfaces of panel door (measured flat overall); over 300mm girth Metalwork Etching primer and enamel paint as specified

M2

10

Surfaces of metal door frame; over 300mm girth

M2

36

To Collection

Item Collection

Description

Unit

Quantity

Rate

Amount

WINDOWS, VENTS AND EXTERNAL DOORS B1/19 B1/20 B1/21 B1/22 B1/23

To Summary

Item INTERNAL WALLS

Description

Unit

Quantity

Rate

Amount

BRICKWORK AND BLOCKWORK LOAD BEARING SUPERSTRUCTURE Common bricks as specified; in cement mortar (1:3) Walls A Half brick thick; stretcher bond Damp proof course as specified; 100 laps; bedding in cement mortar (1:3); no allowance in measurement for laps On horizontal surfaces B 115mm Wide WOODWORK BOARDING AND FLOORING 'NEWLUX" or approved equivalent calsium silicate board cladding Boarding to walls; shiplapped joints C 9mm Thick vertically fixed to with and including mild steel plate, bolt and nuts with finishes complete all as per drawing no. M 32 M2 222

M2

17

To Summary

Item INTERNAL DOORS CONCRETE WORK PRECAST CONCRETE Precast concrete lintel A

Description

Unit

Quantity

Rate

Amount

150mm x 115mm Precast concrete Grade 30 as specified lintel; reinforced with and including 4 nos. 12mm Diameter high tensile bars and 6mm diameter mild steel stirrups; fair finish all faces Precast concrete heel stones

15

150mm x 50mm x 150mm High cast to profile of door frame including wrot formwork as specified WOODWORK UNFRAMED FIXING Sawn pressure treated Group `B' timber as specified Stops

NO

12

50mm x 18mm Window beads, nosings, or the likes

75mm x 13mm Wrot pressure treated Group `B' timber as specified Framework to brick walls; to receive door finish

150mm x 50mm hardwood frame Architrave, cover fillets or the likes

75mm x 15mm; splays COMPOSITE ITEM Wrot pressure treated Group `B' timber as specified Flush door

111

900mm x 2100mm x 40mm Thick door (Type P4) comprising of 100mm x 30mm top rail, 50mm x 30mm intermediate frame, 150mm x 30mm bottom rail and 100mm x 30mm side frame; covered with 4mm thick plywood lining with an approved water-proof lamination on both sides, and lipped all around with twice rebated edging all as per drawing no. 800mm x 2100mm x 40mm thick doors (Type P6) comprising of 50mm x 30mm intermediate frame ,100mm x 30mm top rail, side frame; 150mm x 30mm bottom rails; covered both sides with 4mm thick plywood lining with an approved water proof lamination on both sides lipped all around with twice rebated edging and including mild steel frame and all necessary fixing to brickwork or concrete as per drawing no. Q( ) ( ) 900mm x 2100mm x 40mm Thick door (Type P5) comprising of 100mm x 30mm top rail, 50mm x 18mm intermediate frame, 150mm x 30mm bottom rail and 100mm x 30mm side frame; 50mm x 18mm nogging, 12mm thick fixed louvres size 350mm x 500mm including 20mm 40mm framing all round and 12mm beading and covered with 4mm thick plywood lining on both sides, and lipped all around with twice rebated Q( ) ( ) O

NO

NO

NO

To Collection

Item INTERNAL DOORS (Contd) WOODWORK (Contd) Panelled door A

Description

Unit

Quantity

Rate

Amount

900mm x 2100mm x 50mm thick decorative door in 8 panel (Type P3) all as per drawing (framing and ironmongeries measured separately) IRONMONGERY Ironmongery or other equal and approved; to timber or concrete including providing requisite matching screws Knobset

NO

'NEMEF H30349/715/760' or approved equivalent mortise body complete with KTT and lever handle 'TREX RC 607 - H30 - 70mm or approved equivalent SSF Knobset 'YALE ANSI Grade 3 CA5237-H30-70' or approved equivalent SSF 'YALE ANSI Grade 3 CA5232-H30-70' or approved equivalent SSF 'TREX H30 1729' or approved equivalent hat and coat hook Hinges

NO NO NO NO NO

1 6 1 4 8

C E E F

102mm x 76mm x 2mm 'TREX PB H30' or approved equivalent plain bearing stainless steel hinges 102mm x 76mm x 2mm 'TREX NRH30' or approved equivalent nylon ring galvanised steel hinges Door closer/stopper

NO

24

NO

12

J K

TREX H30, 38mm rubber stopper YALE H30, Door Guard US3 finish METALWORK DOORS Mild Steel door frame to manufacturer's detail

NO NO

8 7

320mm Girth; including fixed to wall and lintol PAINTING AND DECORATING NEW WORK Woodwork Knot and stop, prime and enamel paint as specified

56

M N P

General surfaces of timber; 150mm - 300mm Girth On surfaces of timber frame; 0mm - 150mm girth On surfaces of door ; over 300mm girth Metalwork Etching primer and enamel paint as specified

M M M2

5 111 46

General surfaces of metal; over 300mm girth

M2

18

To Collection

Item Collection INTERNAL DOORS

Description

Unit

Quantity

Rate

Amount

B1/26 B1/27

To Summary

Item

Description EXTERNAL FLOOR FINISHES FLOOR, WALL AND CEILING FINISHINGS FLOOR In situ Finishings Cement and sand (1:3) rendering as specified; trowelled smooth

Unit

Quantity

Rate

Amount

20 Thick to apron; level, falls and crossfalls and to slope not exceeding 15 degrees from horizontal; laid to fall Tile, Slab and Block Finishing Homogeneous floor tiles; 300mm x 300mm x 8.5mm as specified; bedded and jointed in cement and sand (1:3) mortar; pointing with grout in white cement; on and including 20mm thick cement and sand (1:3)

M2

21

B C

Floor; level, falls and crossfalls and to slope not exceeding 15 degrees 100mm High to skirtings; with bull nose on edge Ceramic floor tiles, 200mm x 200mm x 6.8mm as specified; bedded and jointed in cement mortar (1:3); pointing with grout in white cement; on and including 20mm thick cement and sand (1:3) screeded bed

M2 M

55 36

D E

Floor, level, falls and crossfalls and to slope not exceeding 15 degrees 100mm High to skirtings; with bull nose on edge Approved interlocking concrete tiles as specified with and including 50mm thick sand bed as per manufacturer's instructions

M2 M

8 9

Floor; level, falls and crossfalls and to slope not exceeding 15 degrees Accessories Brass dividing strips; setting in bed or finishing

M2

3mm x 10mm; flat section

To Summary

Item

Description INTERNAL FLOOR FINISHES FLOOR, WALL AND CEILING FINISHINGS FLOOR In situ Finishings Cement and sand (1:3) rendering as specified; trowelled smooth

Unit

Quantity

Rate

Amount

20 Thick to floor; level, falls and crossfalls and to slope not exceeding 15 degrees from horizontal Tile, Slab and Block Finishing Homogeneous floor tiles; 200mm x 200mm x 8.5mm as specified; bedded and jointed in cement and sand (1:3) mortar; pointing with grout in white cement; on and including 20mm thick cement and sand (1:3)

M2

B C

Floor; level, falls and crossfalls and to slope not exceeding 15 degrees 100mm High to skirtings; with bull nose on edge Homogeneous floor tiles; 300mm x 300mm x 8.5mm as specified; bedded and jointed in cement and sand (1:3) mortar; pointing with grout in white cement; on and including 20mm thick cement and sand (1:3)

M2 M

33 33

D E

Floor; level, falls and crossfalls and to slope not exceeding 15 degrees 100mm High to skirtings; with bull nose on edge 'Non slip' homogeneous floor tiles; 200mm x 200mm x 8.5mm as specified; bedded and jointed in cement and sand (1:3) mortar; pointing with grout in white cement; on and including 20mm thick cement and

M2 M

66 46

F G

Floor; level, falls and crossfalls and to slope not exceeding 15 degrees 100mm High to skirtings; with bull nose on edge Ceramic floor tiles, 300mm x 300mm x 6.8mm as specified; bedded and jointed in cement mortar (1:3); pointing with grout in white cement; on and including 20mm thick cement and sand (1:3) screeded bed

M2 M

19 32

H J

Floor, level, falls and crossfalls and to slope not exceeding 15 degrees 100mm High to skirtings; with bull nose on edge Hardwood timber strip; timber strip with an approved adhesive on and including 20mm thick cement and sand (1:3) screeded bed

M2 M

60 45

100mm High timber skirting on concrete base with top rounded edge 'Kempas' timber strip; 50mm x 10mm timber strip with an approved adhesive on and including 20mm thick cement and sand (1:3) screeded

91

Floor, level, falls and crossfalls and to slope not exceeding 15 degrees

M2

102

To Collection

Item

Description INTERNAL FLOOR FINISHES (Contd) PAINTING AND DECORATING (Contd) PAINTING AND DECORATING NEW WORK Woodwork Varnish as specified

Unit

Quantity

Rate

Amount

A B

General surfaces of timber beading; 0mm - 150mm Girth General surfaces of timber; over 300mm Girth

M M2

91 102

To Collection

Item Collection

Description

Unit

Quantity

Rate

Amount

INTERNAL FLOOR FINISHES B1/30 B1/31

To Summary

Item

Description EXTERNAL CEILING FINISHES WOODWORK CARCASSING ITEMS Sawn pressure treated Group `B' timber as specified Pitched roof members including ceiling joists

Unit

Quantity

Rate

Amount

A B

100mm x 50mm Ceiling Joist 50mm x 50mm Nogging FLOOR, WALL AND CEILING FINISHINGS CEILING Ceiling Board Cement Board ceiling as specified; 600mm x 1200mm x 4.5mm Thick fixed to ceiling joist and spacer (measured separately) and including all necessary timber beading

M M

293 112

Linings to ceilings Suspended ceilings; Cement Board ceiling as specified; 600mm x 1200mm x 4.5mm thick lay in grid and complete with metal framing and tee-grid channel suspension system

M2

124

Linings to ceilings; Fibrous Plaster Suspended ceilings; Fibrous plaster ceiling board as specified; 1200mm x 1800mm x 4.5mm thick lay in grid and complete with metal framing and tee-grid channel suspension system

M2

Linings to ceilings Fibre glass reinforced concrete cornice

M2

20

100mm x 100mm Overall size to fibrous plaster board ceiling; level, falls,falls and crossfalls and to slope not exceeding 15 degrees from PAINTING AND DECORATING NEW WORK Ceiling Finishes Acrylic weathershield paint as specified

17

G H

To soffits of ceiling panel To cornice; 150mm - 300mm girth Woodwork Knot and stop, prime and enamel paint as specified

M2 M

152 17

General surfaces of timber beading; 0mm - 150mm Girth

405

To Summary

Item

Description INTERNAL CEILING FINISHES FLOOR, WALL AND CEILING FINISHINGS CEILING Plastering Cement and sand (1:6) with an approved plasticiser as specified, trowelled finish to sides and soffit of beams and concrete slab

Unit

Quantity

Rate

Amount

20mm Thick Ceiling Board Suspended ceilings; Cement Board ceiling as specified; 600mm x 1200mm x 4.5mm thick lay in grid and complete with metal framing and tee-grid channel suspension system

M2

63

Linings to ceilings; Fibrous Plaster Suspended ceilings; Fibrous plaster ceiling board as specified; 1200mm x 1800mm x 4.5mm thick lay in grid and complete with metal framing and tee-grid channel suspension system

M2

22

C D

Linings to ceilings EXTRA OVER for forming 600mm x 600mm access panel and including all necessary framing Fibre glass reinforced concrete cornice

M2

183

NO

100mm x 100mm Overall size to fibrous plaster board ceiling; level, falls,falls and crossfalls and to slope not exceeding 15 degrees from PAINTING AND DECORATING NEW WORK Ceiling Finishes Emulsion paint as specified

102

F G H

On ceiling board; over 300mm girth To soffit of plastered suspended slab and beams; over 300mm girth On cornice; 150 - 300mm girth

M2 M2 M

205 63 102

To Summary

Item EXTERNAL WALL FINISHES

Description

Unit

Quantity

Rate

Amount

FLOOR, WALL AND CEILING FINISHINGS WALL Plastering Cement and sand (1:6) plainface plaster mixed with an approved plasticiser as specified; steel trowelled A B C 20mm Thick work to walls on brickwork, blockwork or concrete work 20mm Thick work to isolated column EXTRA OVER for coping 300mm girth; not exceeding 300 mm Tile work 150mm x 100mm Stack stone as specified, bedded jointed and pointed in cement mortar ( 1:3 ); on and including 20mm thick cement and sand D Tiled to wall PAINTING AND DECORATING NEW WORK Wall Finishes Acrylic weathershield paint as specified E F G On plastered isolated column; over 300mm girth On plastered wall; 150mm - 300mm girth On plastered wall; over 300mm girth M2 M M2 12 64 300 M2 30 M2 M2 M 300 12 64

To Summary

Item INTERNAL WALL FINISHES

Description

Unit

Quantity

Rate

Amount

FLOOR, WALL AND CEILING FINISHINGS WALL Plastering Cement and sand (1:6) plainface plaster mixed with an approved plasticiser as specified; steel trowelled A 20mm Thick work to walls on brickwork, blockwork or concrete work Tile work Ceramic wall tiles 200mm x 200mm as specified, bedded jointed and pointed in cement mortar (1:3); on and including 20mm thick cement B Tiled to wall PAINTING AND DECORATING NEW WORK Wall Finishes Emulsion paint as specified C On plastered wall; over 300mm girth M2 697 M2 84 M2 697

To Summary

Item

Description FITTINGS AND FURNISHINGS WOODWORK COMPOSITE ITEM Wrot pressure treated Group `C' timber as specified Fittings

Unit

Quantity

Rate

Amount

Kitchen cabinet; overall size 450mm x 600mm x 750mm high kitchen cabinet all as per drawing (Type B15) Kitchen cabinet; overall size 600mm x 600mm x 750mm high kitchen cabinet all as per drawing (Type B12) Kitchen cabinet; overall size 600mm x 600mm x 2000mm high kitchen cabinet all as per drawing (Type T10) Kitchen cabinet; overall size 900mm x 600mm x 750mm high kitchen cabinet all as per drawing (Type B13) Kitchen sink worktop cum cabinet ; overall size 1200mm x 600mm x 750mm all as per drawing (Type S18) High level wall hung cabinet; overall size 450mm x 300mm x 450mm high all as per drawing (TypeG5) High level wall hung cabinet; overall size 450mm x 300mm x 600mm high all as per drawing (TypeG1) High level wall hung cabinet; overall size 600mm x 300mm x 450mm high all as per drawing (TypeG6) High level wall hung cabinet; overall size 900mm x 300mm x 450mm high all as per drawing (TypeG7) High level wall hung cabinet; overall size 900mm x 300mm x 600mm high all as per drawing (TypeG3) `L' shaped cabinet; overall size 1950mm x 300mm x 450mm high as per drawing No.HQA (98) A208 / C6 (SBH) PR 1b Wardrobe; overall size 450mm x 600mm x 1200mm high all as per Wardrobe; overall size 450mm x 600mm x 2400mm high all as per Wardrobe; overall size 1500mm x 600mm x 2400mm high all as per drawing (Type BT5) Wardrobe; overall size 600mm x 450mm x 2100mm high,comprising of shelves and glass door all as per drawing (Type RT2) Shoes Cabinet; overall size 1050mm x 400mm x 2100mm high comprising of shelves and fixed louvre door all as per manufacturer's Tv cabinet; overall size 1500mm x 450mm x 2100mm high comprising of shelves and glass door all as per manufacturer's detail and drawing

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO

NO NO NO

1 3 4

M N P

NO

NO

NO

NO

To Summary

Item SANITARY FITTINGS

Description

Unit

Quantity

Rate

Amount

PLUMBING AND MECHANICAL ENGINEERING INSTALLATIONS SANITARY INSTALLATION; FITTINGS Supply and fix the following Sanitary Fittings and accessories, including jointing and connecting to services and soil and waste pipes and making good all work disturbed; internally Basin A Approved 570mm x 4200mm vitreous china counter top vanity basin complete with plastic bottle trap; waste plug and chain complete with pillar tap; bright chrome plated with metal handle including making good Approved 500mm x 420mm vitreous wall hung wash basin complete with plastic bottle trap; waste plug and chain complete with pillar tap; bright chrome plated with metal handle including making good wall tiling Water Closet C Approved back inlet squatting water closet pan in white vitreous china complete with integral foot treads and loose 'S' trap in vitreous china; complete with 6 litres mid level cistern (level) and lid in vitreous china and complete with all necessary internal fittings; bedding pan in concrete bed and including working or making good floor and wall tiling around. Approved close coupled washdown pedestal water closet in vitreous china with horizontal/bottom outlet in vitreous china; 6 litres button activated cistern and lid in vitreous china complete with all necessary internal fittings; complete with hinged seat and cover in matching colour; fixing pan with screws and setting pan in tiled concrete floor and Shower E Approved equivalent complete with arm and hand wall flanged with stop Soap Holder F Approved equivalent 310mm x 160mm x 95mm semi recessed soap and sponge holder in vitreous china fixed to tiled wall Approved equivalent 165mm x 165mm x 95mm semi recessed soap dish in vitreous china fixed to tiled wall Mirror H 600mm x 1000mm x 6mm Thick approved bevelled edge plate glass complete with 4mm thick waterproof plywood backing and fixed with chromium plated dome headed fixing screws and cork washers Toilet Roll Holder J Approved equivalent 165mm x 165mm x 95mm semi recessed toilet roll holder in vitreous china complete with plastic roller Towel Rail K Screw to wall complete with 600mm x 125mm chrome plated bar, plastic rail insert and accessories fixing screws and plug NO 3

NO

NO

NO

NO

NO

NO

NO

NO

NO

To Collection

Item

Description SANITARY FITTINGS (Contd) PLUMBING AND MECHANICAL ENGINEERING INSTALLATIONS Tap and Hand Bidet

Unit

Quantity

Rate

Amount

Approved 12mm diameter booster bib tap; bright crome plated with arrowline metal handle. Approved hand bidet set complete with flexible hose and wall bracket with arrowline metal handle. Water Trough

NO

NO

Approved 558.8mm x 736.6mm (25 gallons) precast terrazo water tub. Floor Trap

NO

Approved floor trap with cover BUILDER'S WORK Stool Plain Concrete Grade 30 as specified

NO

150mm - 300mm thick Class F1 formwork as specified to edge of

M3

Not exceeding 250mm high TESTING Sanitary Installation Pipework and Fittings

On completion of the plumbing installation test all appliances, pipe and fittings, make good any defects and leave the whole in perfect working order to the approval of the Superintending Officer.

IT

To Collection

Item Collection SANITARY FITTINGS

Description

Unit

Quantity

Rate

Amount

B1/38 B1/39

To Summary

Item PLUMBING INSTALLATION

Description

Unit

Quantity

Rate

Amount

PLUMBING AND MECHANICAL ENGINEERING INSTALLATIONS COLD WATER INSTALLATION; PIPEWORK Cold Water System; internally Acrylonitrile Butadiene Styrene (ABS) pipes as specified A Supply pipes and fittings, from and including first stopcock from incoming mains to water storage tanks to sanitary appliances and scour and overflow pipes from water storage tanks, including all necessary excavation, connections with requisite connectors to water storage tank and sanitary appliances, requisite pipe fittings, stopcock and requisite Storage Water Tank Fibreglass Reinforce Polyester (FRP) water tank as specified complete with all accessories and fittings of approved manufacturer to JBA approval, hoisted and placed in position at approximately 6500mm above ground level in accordance to manufacturer's instruction all as B 3000mm x 2000mm x 1000mm High (880 Gallon) SANITARY INSTALLATION PIPEWORK Soil, Waste and Vent Pipes; internally UPVC pipes Class B.S 466 as specified C Waste water, soil and vent pipes with and including all requisite fittings from sanitary appliances and from floor traps and outlet grating to connecting manholes or water channel drains including all necessary excavation, concrete casing around pipework, connections with requisite connectors to sanitary appliances, requisite openings, requisite to h i f fl b d ll l t ll d i N TESTING Soil , waste, vent pipes and cold water installation Pipework D On completion of the plumbing installation test all soil, waste, vent pipes and cold water piping and make good any defects and leave the whole in perfect working order to the entire satisfaction of the Superintending NO 1

IT

IT

it

To Summary

Item :Summary

Description

Unit

Quantity

Rate

Amount

:WORK BELOW LOWEST FLOOR FINISH :RAMPS, APRON AND PERIMETER DRAINS :FRAME :UPPER FLOOR :ROOF :STAIRS :EXTERNAL WALLS AND BALUSTRADING :WINDOWS, VENTS AND EXTERNAL DOORS :INTERNAL WALLS :INTERNAL DOORS :EXTERNAL FLOOR FINISHES :INTERNAL FLOOR FINISHES :EXTERNAL CEILING FINISHES :INTERNAL CEILING FINISHES :EXTERNAL WALL FINISHES :INTERNAL WALL FINISHES :FITTINGS AND FURNISHINGS :SANITARY FITTINGS :PLUMBING INSTALLATION