Sunteți pe pagina 1din 19

KUMPULAN TABEL MIL-STD-105E

Ir. Budi Nurtama, M.Agr.

2008
Program Studi Supervisor Jaminan Mutu Pangan
PROGRAM DIPLOMA
Institut Pertanian Bogor

Tables for MIL-STD-105E *)

Page

Table I. Sample-Size Code Letters.

Table II-A. Single Sampling Plans for Normal Inspection (Master Table).

Table II-B. Single Sampling Plans for Tightened Inspection (Master Table).

Table II-C. Single Sampling Plans for Reduced Inspection (Master Table).

Table III-A. Double Sampling Plans for Normal Inspection (Master Table).

Table III-B. Double Sampling Plans for Tightened Inspection (Master Table).

Table III-C. Double Sampling Plans for Reduced Inspection (Master Table).

Table IV-A. Multiple Sampling Plans for Normal Inspection (Master Table).

Table IV-A.(continued)

Table IV-B. Multiple Sampling Plans for Tightened Inspection (Master Table).

10

Table IV-B.(continued).

11

Table IV-C. Multiple Sampling Plans for Reduced Inspection (Master Table).

12

Table IV-C.(continued).

13

Table V-A. Average Outgoing Quality Limit Factors for Normal Inspection (Single Sampling).

14

Table V-A. Average Outgoing Quality Limit Factors for Tightened Inspection (Single Sampling).

15

Table VIII. Limit Numbers for Reduced Inspection.

16

*) Farnum, Nicholas R. 1994. Modern Statistical Quality Control and Improvement. Wadsworth, Inc., California.

Tahapan Implementasi MIL-STD-105E


1. Tentukan AQL (Acceptable Quality Level) berdasarkan perjanjian produsen dan pelanggan.
2. Tetapkan modus dan tingkat inspeksi (jika tidak, gunakan Normal Inspection, Level II ).
3. Tentukan ukuran lot (lot size).
4. Gunakan tabel Sample Size Code Letters untuk memilih huruf kode yang sesuai.
5. Tetapkan tipe prosedur pengambilan sampel : single, double, atau multiple sampling.
6. Gunakan tabel yang berkaitan dengan prosedur pengambilan sampel terpilih (tahap 5) dan modus/tingkat inspeksi (tahap 2) untuk mendapatkan ukuran sampel
dan angka penerimaan (Ac) serta angka penolakan (Re). Dalam kasus dimana suatu rancangan tidak ada untuk ukuran lot dan AQL-nya, hati-hati mengikuti
tanda panah dalam tabel ke rancangan terdekat yang ada.
7. Mulailah gunakan rancangan tersebut dan catat penerimaan dan penolakan sehingga switching rule dapat diterapkan. Jika switching dilakukan, tentukan modus
dan tingkat dan ulangi tahap 4-6 untuk mendapatkan rancangan pengambilan sampel yang baru.

SWITCHING RULE for MIL-STD-105E


Dari Normal ke Tightened Inspection : setelah 2 lot ditolak dari 2, 3, 4, atau 5 lot berurutan
Dari Tightened ke Normal Inspection : setelah 5 lot berurutan diterima
Dari Normal ke Reduced Inspection

: jika (i) 10 lot berurutan diterima, dan (ii) jumlah total nonconforming items dalam 10 lot tersebut tidak melebihi batas
pada Table VIII. Limit Numbers for Reduced Inspection., dan (iii) produksi stabil/mantap, dan (iv) disetujui oleh otoritas
yang bertanggungjawab.

Dari Reduced ke Normal Inspection

: jika (i) suatu lot tunggal ditolak, atau (ii) suatu lot hanya sebagian dapat diterima (dhi. jumlah nonconforming items
diantara angka diterima dan ditolak), atau (iii) produksi menjadi tidak stabil, atau (iv) kondisi-kondisi lain yang
menjamin bahwa inspeksi Normal dapat dilakukan.

ii

Table I. Sample-Size Code Letters.

Special Inspection Levels

General Inspection Levels

Lot or batch size


S-1

S-2

S-3

S-4

II

III

to

to

15

16

to

25

26

to

50

51

to

90

91

to

150

151

to

280

281

to

500

501

to

1,200

1,201

to

3,200

3,201

to

10,000

10,001

to

35,000

35,001

to

150,000

150,001

to

500,000

500,001

and

over

Table II - A. Single Sampling Plans for Normal Inspection (Master Table).


Acceptable Quality Levels (normal inspection)
Sample
size Sample 0.010 0.015 0.025 0.040 0.065 0.10
0.15
0.25
0.40
0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650
1000
size
code
letter
Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A

13

20

32

50

80

125

200

315

500

800

1250

2000

0 1

1 2

2 3

3 4

5 6

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31 44 45

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31 44 45

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31 44 45

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31 44 45

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22

2 3

3 4

5 6

7 8 10 11 14 15 21 22

0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1

1 2

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.

Ac = Acceptance number.

= Use first sampling plan above arrow.

Re = Rejection number.

7 8 10 11 14 15 21 22 30 31

Table II - B. Single Sampling Plans for Tightened Inspection (Master Table).


Acceptable Quality Levels (tightened inspection)
Sample
size Sample 0.010 0.015 0.025 0.040 0.065 0.10
0.15
0.25
0.40
0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650
1000
size
code
letter
Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A

13

20

32

50

80

125

200

315

500

800

1250

2000

3150

1 2

2 3

3 4

5 6

1 2

2 3

3 4

5 6

8 9 12 13 18 19 27 28 41 42

1 2

2 3

3 4

5 6

8 9 12 13 18 19 27 28 41 42

1 2

2 3

3 4

5 6

8 9 12 13 18 19 27 28 41 42

1 2

2 3

3 4

5 6

8 9 12 13 18 19 27 28 41 42

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

1 2

2 3

3 4

5 6

8 9 12 13 18 19

2 3

3 4

5 6

8 9 12 13 18 19

0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1

1 2

8 9 12 13 18 19 27 28

1 2

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.

Ac = Acceptance number.

= Use first sampling plan above arrow.

Re = Rejection number.

Table II - C. Single Sampling Plans for Reduced Inspection (Master Table).


Acceptable Quality Levels (reduced inspection)
Sample
size Sample 0.010 0.015 0.025 0.040 0.065 0.10
0.15
0.25
0.40
0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650
1000
size
code
letter
Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A

13

20

32

50

80

125

200

315

500

800

0 1

1 2

2 3

3 4

5 6

7 8 10 11 14 15 21 22 30 31

0 2

1 3

2 4

3 5

5 6

7 8 10 11 14 15 21 22 30 31

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13 14 17 21 24

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13 14 17 21 24

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13 14 17 21 24

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 2

1 3

1 4

2 5

3 6

5 8

7 10 10 13

1 3

1 4

2 5

3 6

5 8

7 10 10 13

0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1
0 1

0 2

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.

Ac = Acceptance number.

= Use first sampling plan above arrow.


= If the acceptance number has been exceeded, but the rejection number has not been reached; accept the lot, but reinstate normal inspection.

Re = Rejection number.

Table III - A. Double Sampling Plans for Normal Inspection (Master Table).
Acceptable Quality Levels (normal inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7 5 9 7 11 11 16
8 9 12 13 18 19 26 27

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

0 3
3 4

1 4
4 5

2 5
6 7

3 7
8 9

A
B

First
Second

2
2

2
4

First
Second

3
3

3
6

First
Second

5
5

5
10

First
Second

8
8

8
16

First
Second

13
13

13
26

First
Second

20
20

20
40

First
Second

32
32

32
64

First
Second

50
50

50
100

First
Second

80
80

80
160

First
Second

125
125

125
250

First
Second

200
200

200
400

First
Second

315
315

315
630

First
Second

500
500

500
1000

First
Second

800
800

800
1600

First
1250
Second 1250

1250
2500

0 2
1 2

5 9 7 11 11 16 17 22 25 31
12 13 18 19 26 27 37 38 56 57

5 9 7 11 11 16 17 22 25 31
12 13 18 19 26 27 37 38 56 57

5 9 7 11 11 16 17 22 25 31
12 13 18 19 26 27 37 38 56 57

5 9 7 11 11 16 17 22 25 31
12 13 18 19 26 27 37 38 56 57

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

5 9 7 11 11 16
12 13 18 19 26 27

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use first sampling plan above arrow.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).

Ac = Acceptance number.
Re = Rejection number.

Table III - B. Double Sampling Plans for Tightened Inspection (Master Table).
Acceptable Quality Levels (normal inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5 3 7 6 10 9 14
6 7 11 12 15 16 23 24

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 2
1 2

0 3
3 4

1 4
4 5

2 5 3 7 6 10 9 14
6 7 11 12 15 16 23 24

0 2
1 2

0 3
3 4

1 4
4 5

2 5
6 7

0 3
3 4

1 4
4 5

2 5
6 7

A
B

First
Second

2
2

2
4

First
Second

3
3

3
6

First
Second

5
5

5
10

First
Second

8
8

8
16

First
Second

13
13

13
26

First
Second

20
20

20
40

First
Second

32
32

32
64

First
Second

50
50

50
100

First
Second

80
80

80
160

First
Second

125
125

125
250

First
Second

200
200

200
400

First
Second

315
315

315
630

First
Second

500
500

500
1000

First
Second

800
800

800
1600

First
1250
Second 1250

1250
2500

First
2000
Second 2000

2000
4000

0 2
1 2

3 7 6 10 9 14 15 20 23 29
11 12 15 16 23 24 34 35 52 53

3 7 6 10 9 14 15 20 23 29
11 12 15 16 23 24 34 35 52 53

3 7 6 10 9 14 15 20 23 29
11 12 15 16 23 24 34 35 52 53

3 7 6 10 9 14 15 20 23 29
11 12 15 16 23 24 34 35 52 53

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

3 7 6 10 9 14
11 12 15 16 23 24

0 2
1 2

= Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use first sampling plan above arrow.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).

Ac = Acceptance number.
Re = Rejection number.

Table III - C. Double Sampling Plans for Reduced Inspection (Master Table).
Acceptable Quality Levels (reduced inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10 7 12 11 17
8 12 12 16 18 22 26 30

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 2
0 2

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

0 3
0 4

0 4
1 5

0 4
3 6

1 5
4 7

2 7
6 9

3 8 5 10
8 12 12 16

A
B
C

First
Second

2
2

2
4

First
Second

3
3

3
6

First
Second

5
5

5
10

First
Second

8
8

8
16

First
Second

13
13

13
26

First
Second

20
20

20
40

First
Second

32
32

32
64

First
Second

50
50

50
100

First
Second

80
80

80
160

First
Second

125
125

125
250

First
Second

200
200

200
400

First
Second

315
315

315
630

First
Second

500
500

500
1000

=
=
Ac =
Re =
=
=

0 2
0 2

3 8 5 10 7 12 11 17
8 12 12 16 18 22 26 30

Use first sampling plan below arrow. If sample size equals or exceeds lot or batch size, do 100 percent inspection.
Use first sampling plan above arrow.
Acceptance number.
Rejection number.
Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
If, after the second sample, the acceptance number has been exceeded, but the rejection number has not been reached, accept the lot, but reinstate normal inspection.

Table IV - A. Multiple Sampling Plans for Normal Inspection (Master Table).


Acceptable Quality Levels (normal inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A
B
C
D

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

2
2
2
2
2
2
2
3
3
3
3
3
3
3
5
5
5
5
5
5
5
8
8
8
8
8
8
8
13
13
13
13
13
13
13
20
20
20
20
20
20
20

2
4
6
8
10
12
14
3
6
9
12
15
18
21
5
10
15
20
25
30
35
8
16
24
32
40
48
56
13
26
39
52
65
78
91
20
40
60
80
100
120
140

#
#
0
0
1
1
2

2
2
2
3
3
3
3

#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6
#
1
2
3
5
7
9

# 2
# 2
0 2
0 3
1 3
1 3
2 3
2 # 2
2 0 3
2 0 3
3 1 4
3 2 4
3 3 5
3 4 5
2 # 3
3 0 3
3 1 4
4 2 5
4 3 6
5 4 6
5 6 7
3 # 4
3 1 5
4 2 6
5 3 7
6 5 8
6 7 9
7 9 10
4
0 4
5
1 6
6
3 8
7
5 10
8
7 11
9 10 12
10 13 14

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19

++
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26

++
++
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

++
++
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

++
++
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitted at this sample size.

++
++
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

++
++
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

++
++
2 9
7 14
13 19
19 25
25 29
31 33
37 38
4 12
11 19
19 27
27 34
36 40
45 47
53 54

++
++
4 12
11 19
19 27
27 34
36 40
45 47
53 54
6 16
17 27
29 39
40 49
53 58
65 68
77 78

++
++
6 16
17 27
29 39
40 49
53 58
65 68
77 78

++
++

++

= Use first sampling plan above arrow.


Re = Rejection number.

Table IV - A. (continued).

Acceptable Quality Levels (normal inspection


Sample
Cumula
size
Sample tive
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
Sample
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
K

++

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

32
32
32
32
32
32
32
50
50
50
50
50
50
50
80
80
80
80
80
80
80
125
125
125
125
125
125
125
200
200
200
200
200
200
200
315
315
315
315
315
315
315
500
500
500
500
500
500
500

32
64
96
128
160
192
224
50
100
150
200
250
300
350
80
160
240
320
400
480
560
125
250
375
500
625
750
875
200
400
600
800
1000
1200
1400
315
630
945
1260
1575
1890
2205
500
1000
1500
2000
2500
3000
3500

#
#
0
0
1
1
2

2
2
2
3
3
3
3

#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6
#
1
2
3
5
7
9

# 2
# 2
0 2
0 3
1 3
1 3
2 3
2 # 2
2 0 3
2 0 3
3 1 4
3 2 4
3 3 5
3 4 5
2 # 3
3 0 3
3 1 4
4 2 5
4 3 6
5 4 6
5 6 7
3 # 4
3 1 5
4 2 6
5 3 7
6 5 8
6 7 9
7 9 10
4
0 4
5
1 6
6
3 8
7
5 10
8
7 11
9 10 12
10 13 14

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26

# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
1 6
3 8
5 10
7 11
10 12
13 14
0 5
3 8
6 10
8 13
11 15
14 17
18 19
1 7
4 10
8 13
12 17
17 20
21 23
25 26
2 9
7 14
13 19
19 25
25 29
31 33
37 38

0
1
3
5
7
10
13
0
3
6
8
11
14
18
1
4
8
12
17
21
25
2
7
13
19
25
31
37

4
6
8
10
11
12
14
5
8
10
13
15
17
19
7
10
13
17
20
23
26
9
14
19
25
29
33
38

0
3
6
8
11
14
18
1
4
8
12
17
21
25
2
7
13
19
25
31
37

5
8
10
13
15
17
19
7
10
13
17
20
23
26
9
14
19
25
29
33
38

1
4
8
12
17
21
25
2
7
13
19
25
31
37

7
10
13
17
20
23
26
9
14
19
25
29
33
38

2
7
13
19
25
31
37

9
14
19
25
29
33
38

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 1
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
= Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitte

Table IV - B. Multiple Sampling Plans for Tightened Inspection (Master Table).


Acceptable Quality Levels (tightened inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A
B
C
D

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

2
2
2
2
2
2
2
3
3
3
3
3
3
3
5
5
5
5
5
5
5
8
8
8
8
8
8
8
13
13
13
13
13
13
13
20
20
20
20
20
20
20

2
4
6
8
10
12
14
3
6
9
12
15
18
21
5
10
15
20
25
30
35
8
16
24
32
40
48
56
13
26
39
52
65
78
91
20
40
60
80
100
120
140

#
#
0
0
1
1
2

2
2
2
3
3
3
3

#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
4
4
5
6
6
7

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6
#
1
2
3
5
7
9

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
4
4
5
6
6
7
4
5
6
7
8
9
10

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22

++
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

++
++
# 3
0 3
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

++
++
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitted at this sample size.

++
++
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

++
++
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

++
++
1 8
6 12
11 17
16 22
22 25
27 29
32 33
3 10
10 17
17 24
24 31
32 37
40 43
48 49

++
++
3 10
10 17
17 24
24 31
32 37
40 43
48 49
6 15
16 25
26 36
37 46
49 55
61 64
72 73

++
++
6 15
16 25
26 36
37 46
49 55
61 64
72 73

++
++

++

= Use first sampling plan above arrow.


Re = Rejection number.

10

Table IV - B. (continued).
Acceptable Quality Levels (tightened inspection)
Sample
Cumula
size
Sample tive
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
Sample
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
K

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

32
32
32
32
32
32
32
50
50
50
50
50
50
50
80
80
80
80
80
80
80
125
125
125
125
125
125
125
200
200
200
200
200
200
200
315
315
315
315
315
315
315
500
500
500
500
500
500
500
800
800
800
800
800
800
800

32
64
96
128
160
192
224
50
100
150
200
250
300
350
80
160
240
320
400
480
560
125
250
375
500
625
750
875
200
400
600
800
1000
1200
1400
315
630
945
1260
1575
1890
2205
500
1000
1500
2000
2500
3000
3500
800
1600
2400
3200
4000
4800
5600

#
#
0
0
1
1
2
#
#
0
0
1
1
2

2
2
2
3
3
3
3

#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
4
4
5
6
6
7

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22

# 2
# 2
0 2
0 3
1 3
1 3
2 3
# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

# 2
0 3
0 3
1 4
2 4
3 5
4 5
# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

# 3
0 4
1 4
2 5
3 6
4 6
6 7
# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

# 4
1 5
2 6
3 7
5 8
7 9
9 10
0 4
2 7
4 9
6 11
9 12
12 14
14 15
0 6
3 9
7 12
10 15
14 17
18 20
21 22
1 8
6 12
11 17
16 22
22 25
27 29
32 33

0
2
4
6
9
12
14
0
3
7
10
14
18
21
1
6
11
16
22
27
32

4
7
9
11
12
14
15
6
9
12
15
17
20
22
8
12
17
22
25
29
33

0
3
7
10
14
18
21
1
6
11
16
22
27
32

6
9
12
15
17
20
22
8
12
17
22
25
29
33

1
6
11
16
22
27
32

8
12
17
22
25
29
33

2
2
2
3
3
3
3

11

Table IV - C. Multiple Sampling Plans for Reduced Inspection (Master Table).


Acceptable Quality Levels (reduced inspection)
Sample
Cumula
size
Sample tive
Sample
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
A
B
C
D
E

First
Second
Third
Fourth
Fifth
Sixth
Seventh

2
2
2
2
2
2
2

2
4
6
8
10
12
14

First
Second
Third
Fourth
Fifth
Sixth
Seventh

3
3
3
3
3
3
3

3
6
9
12
15
18
21

First
Second
Third
Fourth
Fifth
Sixth
Seventh

5
5
5
5
5
5
5

5
10
15
20
25
30
35

First
Second
Third
Fourth
Fifth
Sixth
Seventh

8
8
8
8
8
8
8

8
16
24
32
40
48
56

First
Second
Third
Fourth
Fifth
Sixth
Seventh

13
13
13
13
13
13
13

13
26
39
52
65
78
91

#
#
0
0
0
0
1

2
2
2
3
3
3
3

++
++

++
++

++

#
#
0
0
0
0
1

2
2
2
3
3
3
3

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

3
4
5
6
7
7
8

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
#
0
0
0
0
1

2
2
2
3
3
3
3

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

3
4
5
6
7
7
8

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
#
0
0
0
0
1

2
2
2
3
3
3
3

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

3
4
5
6
7
7
8

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
#
0
0
0
0
1

2
2
2
3
3
3
3

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

#
#
0
0
0
1
1

2
3
3
4
4
5
5

#
#
0
0
1
1
2

3
3
4
5
6
6
7

#
0
0
1
2
3
4

3
4
5
6
7
7
8

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
1
2
3
5
7
9

#
1
2
3
5
7
9

#
1
2
3
5
7
9

3
4
5
6
7
7
8

++
++

++
++

# 4
0 5
1 6
2 7
3 8
4 9
6 10

#
1
2
3
5
7
9

#
1
2
3
5
7
9

++
++

++
++

++
++

++
++

++
++

++

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

4 0 5 0 6
6 1 7 3 9
8 3 9 6 12
10 5 12 8 15
11 7 13 11 17
12 10 15 14 20
14 13 17 18 22

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitted at this sample size.
= If, after the final sample, the acceptance number has been exceeded but the rejection number has not been reached, accept the lot but reinstate normal inspection.

= Use first sampling plan above arrow.


Re = Rejection number.

12

Table IV - C. (continued).
Acceptable Quality Levels (reduced inspection)
Sample
Cumula
size
Sample tive
0.010 0.015 0.025 0.040 0.065 0.10 0.15 0.25 0.40 0.65
1.0
1.5
2.5
4.0
6.5
10
15
25
40
65
100
150
250
400
650 1000
Sample
code
size sample
letter
size Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re Ac Re
L

First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh
First
Second
Third
Fourth
Fifth
Sixth
Seventh

20
20
20
20
20
20
20
32
32
32
32
32
32
32
50
50
50
50
50
50
50
80
80
80
80
80
80
80
125
125
125
125
125
125
125
200
200
200
200
200
200
200

20
40
60
80
100
120
140
32
64
96
128
160
192
224
50
100
150
200
250
300
350
80
160
240
320
400
480
560
125
250
375
500
625
750
875
200
400
600
800
1000
1200
1400

#
#
0
0
0
0
1

2
2
2
3
3
3
3

#
#
0
0
0
0
1
#
#
0
0
0
1
1

2
2
2
3
3
3
3
2
3
3
4
4
5
5

#
#
0
0
0
0
1
#
#
0
0
0
1
1
#
#
0
0
1
1
2

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7

#
#
0
0
0
0
1
#
#
0
0
0
1
1
#
#
0
0
1
1
2
#
0
0
1
2
3
4

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
3
4
5
6
7
7
8

#
#
0
0
0
0
1
#
#
0
0
0
1
1
#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
3
4
5
6
7
7
8
4
5
6
7
8
9
10

#
#
0
0
0
0
1
#
#
0
0
0
1
1
#
#
0
0
1
1
2
#
0
0
1
2
3
4
#
0
1
2
3
4
6
#
1
2
3
5
7
9

2
2
2
3
3
3
3
2
3
3
4
4
5
5
3
3
4
5
6
6
7
3
4
5
6
7
7
8
4
5
6
7
8
9
10
4
6
8
10
11
12
14

# 2
# 3
0 3
0 4
0 4
1 5
1 5
# 3
# 3
0 4
0 5
1 6
1 6
2 7
# 3
0 4
0 5
1 6
2 7
3 7
4 8
# 4
0 5
1 6
2 7
3 8
4 9
6 10
# 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17

# 3
# 3
0 4
0 5
1 6
1 6
2 7
# 3
0 4
0 5
1 6
2 7
3 7
4 8
# 4
0 5
1 6
2 7
3 8
4 9
6 10
# 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

# 3
0 4
0 5
1 6
2 7
3 7
4 8
# 4
0 5
1 6
2 7
3 8
4 9
6 10
# 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

# 4
0 5
1 6
2 7
3 8
4 9
6 10
# 4
1 6
2 8
3 10
5 11
7 12
9 14
0 5
1 7
3 9
5 12
7 13
10 15
13 17
0 6
3 9
6 12
8 15
11 17
14 20
18 22

#
1
2
3
5
7
9
0
1
3
5
7
10
13
0
3
6
8
11
14
18

4
6
8
10
11
12
14
5
7
9
12
13
15
17
6
9
12
15
17
20
22

0
1
3
5
7
10
13
0
3
6
8
11
14
18

5 0 6
7 3 9
9 6 12
12 8 15
13 11 17
15 14 20
17 18 22
6
9
12
15
17
20
22

= Use first sampling plan below arrow (refer to continuation of table on following page, when necessary). If sample size equals or exceeds lot or batch size, do 100 percent inspection.
= Use corresponding single sampling plan (or alternatively, use double sampling plan below, where available).
Ac = Acceptance number.
++ = Use corresponding double sampling plan (or alternatively, use multiple sampling plan below, where available).
# = Acceptance not permitted at this sample size.
= If, after the final sample, the acceptance number has been exceeded but the rejection number has not been reached, accept the lot but reinstate normal inspection.

= Use first sampling plan above arrow.


Re = Rejection number.

13

Table V-A. Average Outgoing Quality Limit Factors for Normal Inspection (Single Sampling) *
Code Sample
Letter
size
A

13

20

32

50

80

125

200

315

500

800

1250

2000

Acceptable Quality Level


0.010 0.015 0.025 0.040 0.065

0.10

0.15

0.25

0.40

0.65

1.0

1.5

2.5

4.0

6.5

10

15

18

40

65

100

150

250

400

650

1000

42

69

97

160

220

330

470

730

1100

28

46

65

110

150

220

310

490

720

1100

17

27

39

63

90

130

190

290

430

660

11

17

24

40

56

82

120

180

270

410

6.5

11

15

24

34

50

72

110

170

250

4.2

6.9

9.7

16

22

33

47

73

2.6

4.3

6.1

9.9

14

21

29

46

1.7

2.7

3.9

6.3

9.0

13

19

29

1.1

1.7

2.4

4.0

5.6

8.2

12

18

0.67

1.1

1.6

2.5

3.6

5.2

7.5

12

0.42

0.69

0.97

1.6

2.2

3.3

4.7

7.3

0.27

0.44

0.62

1.00

1.4

2.1

3.0

4.7

0.17

0.27

0.39

0.63

0.90

1.3

1.9

2.9

0.11

0.17

0.24

0.40

0.56

0.82

1.2

1.8

0.11

0.16

0.25

0.36

0.52

0.75

1.2

0.042 0.069 0.097

0.16

0.22

0.33

0.47

0.73

12
7.4
4.6
2.8
1.8
1.2
0.74
0.46
0.29
0.18
0.12
0.074
0.046
0.029

25

0.067

Sample size

* Note: For the exact AOQL, the above volume must be multiplied by 1

Lot
or Batch size

14

Table V-B. Average Outgoing Quality Limit Factors for Tightened Inspection (Single Sampling) *
Code Sample
Letter
size
A

13

20

32

50

80

125

200

315

500

800

1250

2000

3150

Acceptable Quality Level


0.010 0.015 0.025 0.040 0.065

0.10

0.15

0.25

0.40

0.65

1.0

1.5

2.5

4.0

6.5

10

15

6.5

1.8

260

400

620

970

170

270

410

650

1100

17

27

39

63

100

160

250

390

610

11

17

24

40

64

99

160

240

380

11

15

24

40

61

95

150

240

62

2.6

4.3

6.1

9.9

16

25

39

1.7

2.7

3.9

6.3

16

25

1.1

1.7

2.4

4.0

6.4

9.9

0.67

1.1

1.6

2.5

4.1

6.4

9.9

0.42

0.69

0.97

1.6

2.6

4.0

6.2

0.27

0.44

0.62

1.0

1.6

2.5

3.9

0.17

0.27

0.39

0.63

1.0

1.6

2.5

0.11

0.17

0.24

0.40

0.64

0.99

1.6

0.11

0.16

0.25

0.41

0.64

0.99

0.042 0.069 0.097

0.16

0.26

0.40

0.62

0.074
0.046
0.067

0.018

1000

160

40

0.12

650

97

26

0.18

400

110

16

0.29

250

65

9.7

0.46

150

69

6.9

0.74

100

46

4.2

1.2

0.029

65

42
7.4

2.8

40

28

12

4.6

25

10

16

0.027

Sample size

* Note: For the exact AOQL, the above volume must be multiplied by 1

Lot or Batch size

15

Table VIII. Limit Numbers for Reduced Inspection.


Number of
sample units
from last 10
lots or batches

Acceptable Quality Level


0.010 0.015 0.025 0.040 0.065

0.10

0.15

0.25

0.40

0.65

1.0

1.5

2.5

4.0

6.5

10

15

25

40

65

100

150

250

400

650

1000

115
178
301

181
277

20 - 29
30 - 49
50 - 79

0
0

0
0
2

0
1
3

2
3
7

4
7
14

8
13
25

14
22
40

22
36
63

40
63
110

68
105
181

80 - 129
130 - 199
200 - 319

0
0

0
0
2

0
2
4

2
4
8

4
7
14

7
13
22

14
25
40

24
42
68

42
72
115

68
115
181

105
177
277

181
301
471

297
490

320 - 499
500 - 799
800 - 1249

0
0

0
0
2

0
2
4

1
3
7

4
7
14

8
14
24

14
25
42

24
40
68

39
63
105

68
110
181

113
181

189

1250 - 1999
2000 - 3149
3150 - 4999

0
0

0
0
1

0
2
4

2
4
8

4
8
14

7
14
24

13
22
38

24
40
67

40
68
111

69
115
186

110
181

169

5000 - 7999
8000 - 12499
12500 - 19999

0
0

0
0
2

0
2
4

2
4
7

3
7
13

7
14
24

14
24
40

25
42
69

40
68
110

63
105
169

110
181

181

20000 - 31499
31500 - 49999
50000 & over

0
0
2

0
1
3

2
4
7

4
8
14

8
14
25

14
24
40

22
38
63

40
67
110

68
111
181

115
186
301

181

Denotes that the number of sample units from the last ten lots or batches is not sufficient for reduced inspection for this AQL. In this instance more than ten lots or batches may be used for the calculation, provided that the lots or
batches used are the most recent ones in sequence, that they have all been on normal inspection, and that none has been rejected while on original inspection.

16

S-ar putea să vă placă și