Sunteți pe pagina 1din 12

SIMULATION OF MULTISTAGE FLASH DESALINATION PROCESS 1

Osman A. Hamed, Mohammad AK. Al-Sofi, Monazir Imam, G. M. Mustafa Khalid Bamardouf and Hamad Al-Washmi
Saline Water Conversion Corporation P.O.Box 8328, Al-Jubail -31951, Saudi Arabia Tel: + 966-3-343 0012, Fax: + 966-3-343 1615 Email: rdc@swcc.gov.sa

ABSTRACT The majority of large-scale desalination plants in the Arab Gulf area employ the multistage flash (MSF) processes. MSF processes are energy intensive and it is, therefore, essential to search for design and operating conditions which lead to reduction of energy dissipation and consequently lower water production cost. This paper reports a simulation study which was carried out to examine to what extent the thermal irreversibility of an MSF process is influenced by variation of the most important design and operating parameters. The impact of variation of top brine temperature, number of stages and terminal temperature approach on the distiller performance ratio and irreversibility were explored and presented graphically in the term of thermal grids. The simulation study revealed that within the selected range of number of stages (16-40) and top brine temperature (90 120o C), the MSF distiller irreversibility is highly influenced by the number of stages and to a lesser extent by the variation of the top brine temperature. The simulated results are compared with one year operating data obtained from an MSF distiller. The distiller is a cross-tube configuration, which consists of 22 stages and operating at a top brine temperature ranging between 90 to 98o C. Using a steady state simulation program, an envelop of possible operating conditions is constructed for the distiller to interrelate performance ratio, production, recycle flow and top brine temperature. Stage-wise simulation of individual heat transfer coefficients and fouling factors showed that both clean overall heat transfer coefficients (U c) and fouling factors (FF) are stage dependent and conversely the operating overall heat transfer

Presented in the International Conference on Seawater Desalination Technologies on the Threshold on the New Millennium, Kuwait, Nov. 4-7, 2000. 2. Published in Desalination Journal 134, (2001) 195-203.

coefficient (U D) is to a great extent less dependent. The dependence of the distiller irreversibility on the process conditions is reported. The distiller exergy losses varied between 52 and 62 kJ/kg of distillate. Process details, which are responsible for distiller irreversibility are pinpointed and opportunities for better utilization of available energy are discussed. INTRODUCTION The majority of desalination plants in the Arab Gulf Region are currently employing the multistage flash process (MSF) which is producing around 67% of the total world
3 capacity of land-based desalting projects which are capable of producing 100 m /day

[1]. The success and popularity of the process is due to its simplicity, inherent robustness and vast amount of acquired experience which resulted in reducing material and operating costs and increasing life expectancy. The basic technology of modern large scale MSF is similar to the early units and apart from the development of on-line ball cleaning system and scale control techniques, use of corrosion resistant materials and increase of unit capacity to 12 MIGD [2], the development of the process can be considered as evolutionary rather than revolutionary [3]. A brief history of the development of the MSF process as well as specific design features of a modern MSF plant are presented by Darwish, et al. [4].

Although, coupling of MSF process with power generation system has greatly contributed in reducing energy requirement by about 50% or more compared to single purpose desalination plants using the same kind of fuel [5], but it is still considered as an energy intensive process [6]. The need for detailed thermodynamic analysis is thus quite evident in order to get a detailed understanding of the process and search for optimal process irreversibility. Theoretical analysis of the MSF process has been published [7,8] where the relationships among the various designs and operating

parameters were examined. Characteristics of a number of simplified configurations including single stage flashing, once through and recycle MSF units were reported [9].

The exergy method is particularly useful for optimizing the design and operation of the MSF process with the aim of reducing energy consumption. Concepts of first and

second laws of thermodynamics are both used rather than just the first law, to identify

process irreversibility and evaluate the

thermodynamic losses of the process.

Applications of the exergy or availability method to distillation processes were reported [10-15].

In this paper the operational performance of an MSF distiller representing Phase II plant is analyzed and simulated . A computer program is used simulation study and its overall logic and algorithm

Al-Jubail for the

has been previously reported by

Hamed et al. [10]. The simulation program has got the capability to perform energy/exergy performance calculation of the MSF system. A detailed parametric analysis is also intended to be carried out.

AL JUBAIL PHASE II PLANT Al Jubail Phase II power and desalination plant is the largest in the world. It consists of ten Boiler-Turbo-Generator ( BTG ) sets of about 130 MW output each . Each one of the ten back-pressure turbine feeds low grade steam to four MSF distillers ( i.e. forty distillers in total are installed). Thirty distillers have 19 stages in the recovery section and 3 stages in the rejection section each. The remaining 10 distillers have 17 stages in the heat recovery and 2 stages in the heat rejection section each. The evaporators are designed for operation at a brine top temperature of 90.6o C with production of 5.2 MIGD and a top temperature of 112.8o C with a production of 6.29 MIGD [16,17].

One distiller from the group having 22 stages was selected for this simulation study and its design and operating characteristics are shown in Table-1.

OPERATION SIMULATION The simulation program was firstly used to verify that the distiller would operate at the ce area requirements. Comparison between design and simulated values are shown on Table 2. When

performance ratios are compared a good agreement was obtained between design and simulated values and the difference between them is -0.23 and .14 percent for LTO and HTO respectively. It also shows that the surface area requirements for LTO and HTO

are 9.93 and 5.2 percent less than the available area.

Steady state simulation are normally used to generate operating envelopes to describe the possible operating conditions of the MSF distiller [18,19]. An envelope of possible operating conditions of the selected distiller is shown on Figure 1 for winter conditions. It illustrates the operation as performance ratio vs recycle to distillate mass ratio with the following boundary conditions : Nodes along line CF constant recycle concentration ratio of 1.4 and TBT decreased from 112.8 to 90o C constant TBT of 90o C and recycle concentration ratio decreased from 1.4 to 1.25 constant recycle ratio of 1.25 and TBT increasing from 90 to 112.8o C constant TBT of 112.8o C and recycle concentration ratio increased from 1.2 5 to 1.4

Nodes along line FED

Nodes along line DA Nodes along ABC

Simulated Stage-Wise Heat Transfer Coefficients and Fouling Factors Very little information is published on the stagewise heat transfer coefficients and fouling factors [20] and in most cases an average value for the whole recovery section is determined. The simulation program has been used to calculate the overall heat

transfer coefficients and fouling factors of each individual stage and simulation results are shown in Figure 2. The clean overall heat transfer coefficient (Uc) of each stage

which is calculated from the individual heat transfer coefficients of recycle brine and condensing vapors inside and outside the tubes respectively, is highly dependent on the number of recovery stage. The highest value of U c is obtained in the first stage and is This is because the

progressively decreasing towards the low temperature stages.

individual heat transfer coefficients of the recycle brine and the condensing vapors are dependent on their physical properties which are highly influenced by stage operating pressure and temperature. Although, the high temperature stages of the r ecovery section are having higher clean overall heat transfer coefficients compared to the low temperature stages, the operating overall heat transfer coefficients (UD) of the different stages remain virtually constant. This is due to the fact that stages of higher

temperature are experiencing high fouling factors which is offsetting the advantages gained by the clean heat transfer coefficients. The simulated fouling factors of all stages

are lower than the design values and the gap between the two values widens towards the low temperature stages.

OPERATIONAL PERFORMANCE Operational data for the assigned distiller were collected for a period of one year. The distiller was operating a TBT of 90o C for the first 200 days as shown in Figure 3. It

was t hen acid cleaned for the first time after 16 years of operation and the TBT was raised to 98o C. Comparison between the observed and simulated performance ratio was shown in Fig. 3(b) and very close agreement between the two values was observed. Figures 3 (c) and (d) show the variation of the overall heat transfer coefficients (OHTC) and fouling factors (FF) with time. It can be noticed that the impact of acid cleaning was more significant on the thermal performance of the recovery section due to the increase of its OHTC and reduction of FF. Second law thermal analysis of the distiller is shown in Figure 3(a). the overall exergy destruction during the pre-acid period was ranging between 58 and 62 kJ/kg and then dropped to 55-52 kJ/kg after acid cleaning. It also shows the break down of exergy losses among the major subsystems which included heat recovery and rejection section, brine heater, ejector system and wasted in leaving streams. The exergy losses in the

recovery section after acid cleaning are less than that in the pre-acid period, which is accordingly reflected in the reduction of the overall exergy losses. The large exergy

losses in the recovery section are the result of the exergy losses in feed heaters which are having condensing area several times higher than that of the brine heater and heat rejection section and those caused by flashing of brine and distillate in each recovery stage.

PARAMATERIC ANALYSIS A comprehensive simulation study was carried out to examine the interrelationships between the top brine temperature, number of stages, performance ratio, exergy losses and the terminal temperature approach. The terminal temperature approach is the

difference in temperature between the condensing vapor and the recirculating stream leaving the condenser and is an important design parameter depending on the heat transfer area and overall heat transfer coefficient. The interrelationships between the

different parameters are presented in the form of grid network which are shown in Figures 4 and 5 for TTD of 2 and 4 o C, respectively. Both figures reveal that increasing number of stages while keeping top brine temperature constant such as lines AC & BD, results in an increase of both performance ratio and specific condensing area and a decrease of exergy losses. Increase of number of stages will decrease temperature drop per stage which will reduce the irreversibility of the system due to the reduction in condenser and flash exergy losses and results in an improved thermal performance. Increase of performance ratio will reduce steam consumption and consequently minimize operating cost while increase in surface area results in an increase of capital expenditure. Therefore, optimum performance ratio (i.e. that of lowest production cost of water which is site specific) has to be determined by making cost tradeoffs between the cost of process energy and capital cost of the process. Conversely, increasing top brine temperature while keeping number of stages constant (lines such as AB and CD) specific will increase the performance ratio and decrease the

condensing area but its net effect on exergy destruction is not significant.

Within the selected range of number of stages and top brine temperature, the simulation analysis revealed the dependence of exergy losses on number of stages is more appreciable than that due to variation of top brine temperature.

CONCLUSIONS 1. Performance and operation of a 22-stage MSF distiller is simulated. An operating envelope with specific boundary conditions is generated and presented to describe the distiller possible operating conditions.

2.

A one year operation data is used to carry out an energy/exergy thermal analysis of the whole distiller as well as the major subsystems. Dependence of

performance ratio, heat transfer coefficients and exergy losses on the most important operation parameters, is discussed.

3.

A detailed parametric study is carried out. The impact of number of stages and top brine temperature on performance ratio, exergy losses and specific condensing area is presented in the form of grid network.

Table 1 :

Design Characteristics of the Selected Distiller (winter conditions) at low (L) and high temperature operation (HTO). LTO C) 987 10817 2923.55 1936.55 6996 1.98
2 o

Parameter Product water flow m3 /Hr Recycle brine flow m3 /Hr Makeup flow m3 /Hr Blow down flow m /Hr Sea water to rejection m3 /Hr Tube side velocity m/s Brine heater heat transfer coefficient W/m C Fouling allowance m2 o C/W Heat recovery and brine heater Performance ratio kg/1000 kJ
3

(90.6

HTO C) 1184 9556 3504.5 2320.5 7130 1.58

(112.8

2257 0.000176 3.44

2182 0.000176 4.08

Table 2 :

Comparison of design and simulated parameters of the selected distiller (winter conditions) at low (L) and high temperature operation (HTO).
LTO (90.6 o C) Design Simulated Diff. Design HTO (112.8 o C) Simulated Diff.

Parameter

Set product (t/hr) Flow (t/hr) Recycle Conc. Ppm

987 10817 63700 Steam to brine heater 126.77 (t/Hr ) PR ( kg /1000 kJ ) 3.44 Total surface 88459.6 2 Area requirements m (available)

987 10733.6 63461 126.64 3.448 79672.2

0.0% 0.77% 0.37% 0.1%

1184 9556 61400 131.417

1184 9348.1 61508 132,09

0.0% 2.17% 0.17% 0.51% 0.14% 5.2%

-0.23 % 4.08 4.074 9.93% 88459.6 83798.6 (available)

ACKNOWLEDGEMENT The authors gratefully acknowledge the help and useful discussion provided by Mr.

Abdul Salam Al-Mobayed and Anwar Ehsan of Al-Jubail Plants.

9.6
112.8 C

A
109 C

9.4

Performance Ratio (kg / 2326 kJ)

112.8 C TBT=112.8 C

B
106 C

Brine Conc. Ratio

9.2 9 8.8 8.6 8.4 8.2 8

1.4
102 C

C"
109 C 106 C

100 C 98 C 96 C 102 C 100 C 98 C 96 C 94 C 92 C 94 C 92 C

1.25 1.325

D 90 C
90 C

E
90 C

7.8 7.5

8.5

9.5

10

10.5

11

11.5

Recycle to Distillate Ratio

Figure 1 :Operating Analysis of a 22-stage MSF distiller.

5000 Simulated UD Simulated Uc

Overall Heat Transfer Coeff.(kW/m2 K)

4000

3000

2000

1000 0 2 4 6 8 10 12 14 16 18 20

0.2

Fouling Factor(m K/kW)

0.16 Simulated FF 0.12 FF(design)

0.08

0.04

0 0 2 4 6 8 10 12 14 16 18 20

Recovery Stage Number Figure 2 : Variation of Heat Transfer Coefficient and Fouling Factor with Recovery Stage Number

120 100

Acid Cleaning e

Temperature

( C )

80 60 40 20 6

TBT

Flash Range

0.8 0.6

Fouling Fouling Factor

OHTC

4 3 2 1 0 6 5 Av. HTC of H.Recovery Sec. Av. Fouling F. of H.Rec. Sec.

0.4 0.2 0 1

0.8 0.6 0.4 0.2 0

Heat Rec.

(kW/m K)

3 2 1 0

(kg/2326 kJ)

10 9 8 7 70 Simulated

PR

Plant

a
60

50

Exergy Destruction

(kJ/kg)

40

30 Dest. In B/H Dest. In Rejec. 20 Wested in Ejector Dest in Recov. Wasted in leaving Stream Total Losses

10

20

40

60

80

100

120

140

160

180

200

220

240

260

280

300

320

340

Days

Figure 3: Operation Performance of MSF Distiller

360

(m K/kW)

OHTC

Factor(m K/kW)

Brine Heater

Fouled HTC of Brine Heater

Fouling F. of Brine Heaterd

(kW/m K )

110
32 28 36 40

400

C
350 40

Number of Stages 16

20 24 28

32

36

300

A 90
16 Number of Stages 20

TBT, o C
90 100 112 120

250

80

16

200

20 20

Exergy Losses, kJ/kg

70

B
24 24 28 32
o

150

TBT C
36 40

28 32 36 40

100

60

50

50 6 7 8 9 10 11 12 13 14

P e r f o r m a n c e R a t i o , k g / 2 3 2 6 kJ

Figure 4: Dependence of Performance Ratio, Exergy Losses and Specific Condensing Area on TBT and Number of Stages

130
32 36 24 28 20

40 C

230

120

40

Number of Stages 16

32 28 24 20

36

40

190
C

110

170

100

A 16 Number of Stages

Stages 16

TBT, o C
90 100 112 120
24

Exergy Losses, kJ/kg

150

90

20 24 28 32 36 40 C

20

130

80

28 32 36 40

110
D

70 3 4 5 6 7 8 9

90 11 12 13 14

10

Performance Ratio, kg/2326 kJ

Figure 5: Dependence of Performance Ratio, Exergy Losses and Specific Condensing Area on TBT and Number of Stages

Condensing Area, m

210

/(kg/s)

100

24

Condensing Area, m /(kg/s)

REFERENCES 1. 1998 IDA Worldwide Desalting Plants Inventory, Report. 15, June, Prepared and published by Wangnick Consulting GmBH. (1998),

2.

Wade, N.M., (1992), Technical and economic evaluation of distillation and reverse osmosis desalination processes, Regional Water Desalination Symposium, Al-Ain, United Arab Emirates, Vol. 2, 637-660. Morris, R.M., (1992), The development of the multistage flash distillation process, Symposium, Al-Ain, United Arab Emirates, 15-17, Nov., 881-890. Darwish, M.A., El-Refaee, N.M. and Abdel-Jawad, M., (1995), Developments in Multistage Flash Desalting System, Desalination, 100, 35-64. El-Saie, M.H.A., (1992), Technical developments of the MSF desalination process and its prospects for the future, Regional Water Desalination Symposium, Al-Ain, United Arab Emirates, 15-17, Nov., Vol. 2, 579-595. Darwish, M.A., (1995), Desalination Process: A technical comparison, Proceedings of IDA World Congress on Desalination and Water Science, Abu Dhabi, Nov. 18-24, 149-162. Darwish, M.A., (1991), Thermal analysis of multistage flash desalting system, Desalination, 59-79. El-Dessouky, H. and Bingulac, S., (1996), Solving equations simulating the steady-state behavior of the multistage flash desalination process, Desalination, 107, 171-193. El-Dessouky, H., Alatiqi, I. and Ettouney, H., (1998), Process synthesis: The multistage flash desalination system, Desalination, 115, 155-179. Hamed, O.A., amamiri, A.M. Z., Aly, S. and Lior, N., (1996), Thermal performance and exergy analysis of thermal vapor compression desalination system, J. of Energy Convers. Mgmt, Vol. 37, No. 4.,. 379-387. Darwish, M.A., Al-Najem, N. M. and Al-Ahmed, M.S., (1993), Second law analysis of recirculating multistage flash desalting system, Desalination, 89, pp. 289-309. El-Nasher, A.M., (1994), An MSF Evaporator for the UANW 9 and 10 power station. Design Considerations based on energy and exergy, Desalination, 97, pp. 253-279. Hamed, O.A., Al-Sofi, M. AK., Imam, M., Mustafa, G.M., Bamardouf, K. and AlWashmi, H., (1999), Thermal performance of MSF distillation plants in Saudi

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

Arabia, Proceedings of IDA World Congress on Desalination, San Diego, USA, 107-119. 14. Al-Najem, N. M., Darwish, M.A. and Youssef, F.A., (1997), Thermovapor compression desalter: energy and availability analyses of single and multi-effect systems, Desalination, 110, pp. 223-238. Al-Sofi, M. AK, (1984), Fuel & Chemical Consumption in MSF-BTG Dual Purpose Plants, 6th Arab Energy Conference, Algere, Al-Geria, Al-Sofi, M.AK.,et al., (1987), MSF Operation Modes & Antiscalant Dose Rate Optimization, 3rd IDA Conference, Canne, France. Al-Mudaiheem, et al, (1991), MSF Design Configuration in SWCC along the Gulf Coast, 5th IDA Conference, Washington, DC, USA. Hornburg, C.D., and Watson, B.M., (1993), systems, Desalination, 92, 333-351. Operational optimization of MSF

15.

16.

17.

18.

19.

Hussain, A., Woldai, A., Al-Radif, A., Kesou, A., Borsani, R., Sultan, H. and Deshpandey, P.B., (1994), Modeling and simulation of a multistage flash (MSF) desalination plant, Desalination, 97, pp. 555-586. Rautenbach, R. and Schafer, S., (1997), Calculation of stagewise fouling factors from process data of large MSF distillers, Proceedings of IDA World Congress, Madrid,. Vol. 1, 165-177.