Sunteți pe pagina 1din 148

TSG - NOIDA

HCL INFINET

MD110 MADE EASY

TSG - NOIDA

HCL INFINET

MD110 TRAINING
We know that all of you are in voracious hunger to have a feast on MD110 .so we (TSG-TELECOM) decided to come up with a various palatable viands on MD110 .we are happy to be able to provide you with this victuals Do not try to bolt all the things given in this manual,try to take it in a piecemeal basis ,ALEX is the main dish have a taste of that also .

TSG - NOIDA

HCL INFINET

MD110 TRAINING
Though there is no certitude of you getting your stomach bloated by finishing this manual,but I can assure you that this will be the good collation .

Cantering contract TSG TELECOM

chef - v chandra mouli hotel management - Manish khanka & sanjay rai

TSG - NOIDA

HCL INFINET

MENU CARD
1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) MD110 ARCHITECTURE WINFIOL INSTALLATION AND USAGE ALEX INSTALLATION AND USAGE COMMAND OF MD110 EXTENSION RELATED COMMAND FEATURE ACTIVATION VOICEMAIL CALL BILLING ROUTE RELATED COMMANDS DECT TRACE RELATED COMMANDS TAKING PC - REGEN

TSG - NOIDA

HCL INFINET

MD110 TRAINING

TSG - NOIDA

HCL INFINET

1)MD110 ARCHITETURE
MD stands for MODULAR DISTRIBUTED IT is a UNIX based system ASB 501 04 is the marketing name of MD 110 The ASB 501 04 is built up using two superior types of units, namely Line Interface Modules, LIMs, and a Group Switch, GS.  The LIM is a microprocessor controlled unit that can be equipped with any combination of line circuits and other telephony devices. Each LIM has its own control system and switch, and can function as an autonomous PABX or as an integrated part in a larger system. The capacity of a LIM in normal traffic conditions is approximately 20-640 extensions  To build larger systems, the LIMs are interconnected via a Group Switch and 32 channel PCM (Pulse Code Modulation) lines for traffic and control procedures. Two LIMs can be interconnected directly, whereas the Group Switch is required in larger systems    

TSG - NOIDA

HCL INFINET

TSG - NOIDA

HCL INFINET

LIM capacity  No. of extensions  No . Of trunk  Routes per LIM  External lines per route  No of operators ----------640 256 250 99 10

TSG - NOIDA

HCL INFINET

Time slot
In MD110 each LIM has its own processor card (LPU ) ,switching card (LSU ,DSU). The complete LIM can have 1024 time slots ,in the layman language time slot is nothing but ports. LSU is LIM switching unit which is used to switch the complete LIM,and DSU is Distributed Switching Unit which is used to switch inside the magazine

TSG - NOIDA

HCL INFINET

Line interface module(LIM)


Each Lim is of 1024 time slots To the max of 4 magazine can be connected in each Lim Each magazine can have (1024/4 )=256 time slots Each magazine can act as a individual PBX

TSG - NOIDA

HCL INFINET

LIM STACK
IFM IFM IFM PSM

TSG - NOIDA

HCL INFINET

LIM STACK

TSG - NOIDA

HCL INFINET

LIM STACK
IFM
IFM means interface module ,where u can have your extension as well as trunk cards but not control cards

PSM

PSM mean Processor module,here u can have control cards control cards (LPU ,LSU ,DSU)as well as extension and trunk cards

TSG - NOIDA

HCL INFINET

Magazine
0 10 20 22 30 32 40 42 50 52 60 62 63 70 71 72 73 1 S L O T 2 S L O T 3 S L O T 4 S L O T 5 S L O T 6 S L O T 7 S L O T 8 S L O T 9 S L O T 10 S L O T 11 S L O T 12 S L O T 13 S L O T 14 S L O T 15 S L O T 16 S L O T 17 S R L D D G O S S 5 T U U D 0 1 C

32 32 16 16 16 16 16 16 16 16 16 8 8

8 8

8 8

TSG - NOIDA

HCL INFINET

MAGAZINE

TSG - NOIDA

HCL INFINET

Basic Magazine
0 10 20 22 30 32 40 42 50 52 60 62 63 70 71 72 73 T M U L P U 5 R D G S 5 U D C

N I U 2

L S U
3 2

32 32 16 16 16 16 16 16 16 16 16 8 8

1 0

TSG - NOIDA

HCL INFINET

MAGAZINE

TSG - NOIDA

HCL INFINET

Log card

TSG - NOIDA

HCL INFINET

MAGAZINE
 Each magazine has 20 slots out of which 17 are universal 3 are fixed  Each magazine has 256 time slots  By default NIU will be in 60 th time slot  LPU will be in 70 th  LSU will be in 73 th

TSG - NOIDA

HCL INFINET

Hard ware details (Control cards)


 LPU LIM Processor Unit  LSU LIM switching unit which distributes time slots to various LIM  DSU Distributed Switching Unit which distributes time slots inside the LIM.  NIU-Network Interface Unit which provides I/O port ,we can have 3 v.24 port and 1 LAN port for input output function,and one SCSI port for hard disk connection  NIU 2 NIU 2 has all the function of NIU ,addition to that it has inbuilt compact flask disk of 128 Mb  TMU-Tone and Multiparty unit which does tone sending, tone receiving, conference and connection of sound equipment for the feature Music On Hold.

TSG - NOIDA

HCL INFINET

Hard ware (peripheral cards -trunk)


Cards TLU 80 TLU 75 TLU 73/1 TLU 76/3 TLU 79 Use E&M ANALOG TRUNK PRI R2MFC BRI Program unit TLP 22 TLP 11 SLP60 TLP30 SLP60 Time slot 8 8 32 32 8

TSG - NOIDA

HCL INFINET

HARD WARE (PERIPHERAL CARD -EXTENSIONS)


CARDS ELU - 28 ELU-29 ELU-30 ELU-31 ELU-32 ELU-26 USE
DIGITAL EXT ANALOG EXT ALALOG EXT (MW) DECT IP EXT S0 INTERFACE

PROGRAM UNITS KLP 1 ELP 6 ELP 6 CTLP IPLP SLP 60

TIME SLOTS 16 16 12 16 16 8

TSG - NOIDA

HCL INFINET

2)WINFIOL
SAM installation
 SAM Service Assistance Manager (Ericssons proprietary software)  SAM is the suite of software made by Ericsson ,winfiol is one among those which is used for input /output operation .  SAM also has more tools which is used for different purposes.

TSG - NOIDA

HCL INFINET

2)WINFIOL

TSG - NOIDA

HCL INFINET

2)WINFIOL

TSG - NOIDA

HCL INFINET

2)WINFIOL
The previous two screen are the sample of SAM installation ,just like installing any software keep on pressing next until u see finish .

Once it is installed the complete suite will be in start/programs/service assistance manager .

TSG - NOIDA

HCL INFINET

2)WINFIOL

TSG - NOIDA

HCL INFINET

2)WINFIOL
Once it is installed open winfiol 5.2 ,before this please check login cable from Niu2 is connected in your pc com port and also check whether your com port is free In winfiol open new channel as described in the next slide and set the com port parameters .

TSG - NOIDA

HCL INFINET

2)WINFIOL

TSG - NOIDA

HCL INFINET

2)WINFIOL

TSG - NOIDA

HCL INFINET

2)WINFIOL

TSG - NOIDA

HCL INFINET

2)WINFIOL

TSG - NOIDA

HCL INFINET

2)WINFIOL

TSG - NOIDA

HCL INFINET

3)ALEX
Normally ALEX comes along with latest library after installing Alex set the proper path for all the librarys.

After that open Alex and type the command u want to search in search window and to get the particular command syntax follow the following slides

TSG - NOIDA

HCL INFINET

3)ALEX

TSG - NOIDA

HCL INFINET

3)ALEX

TSG - NOIDA

HCL INFINET

3)ALEX

TSG - NOIDA

HCL INFINET

3)ALEX

TSG - NOIDA

HCL INFINET

3)ALEX

TSG - NOIDA

HCL INFINET

3)ALEX

TSG - NOIDA

HCL INFINET

3)ALEX

TSG - NOIDA

HCL INFINET

Initial start up
Once SAM tool and Alex are installed give power supply to all RG5DC and switch on the machine. Put the log card in the LPU 5 and keep on noticing the number it is displaying . At the end if it comes and stops in 104 ,your machine is healthy,or else remember the number call TSG or any of your senior to know about the status of the machine

TSG - NOIDA

HCL INFINET

MD START UP
 INL Initial Load directory  REL1 Reload directory 1  REL2 Reload directory 2  Log card the daughter card used to check the status of the machine  Winfiol windows based software for operation and maintenance

TSG - NOIDA

HCL INFINET

MD START UP
6x Program code and data files are being loaded.  Initial load: Program units from external backup are being loaded.  Load of standby side: Program units from the memory of executing side are being loaded. DS data are also being loaded. 70 Local backup is being updated from external backup. 71 Local backup has been successfully updated.

TSG - NOIDA

HCL INFINET

MD START UP
8X Reload: Program code from external backup are being loaded. 90 Create logical memory
 Initial load:  Memory space for DS data is being reserved and address references are being created for loaded program units.  Reload:  Memory space for DS data is being reserved, data from local backup are being loaded and address references are being created for loaded program units.

TSG - NOIDA

HCL INFINET

MD START UP
91 Actions described at display code 90 has been successfully completed. 92 The loading program (PLF) has requested start of the LIM after loading. 93 The loading program (PLF) has requested start of the LIM after main failure. 94 The loading program (PLF) has requested start of the LIM after unexpected watchdog reset.

TSG - NOIDA

HCL INFINET

MD START UP
95 The loading program (PLF) has requested start of the LIM after two pushes on the reset button on the LPU board. 99 LIM has received a start request in some phase. 100 Initial start phase 1 is ready. 101 Phase 1.5 is ready. 102 Restart phase 1 is ready. 103 Initial start phase 2 is ready. 104 Restart phase 2 is ready.

TSG - NOIDA

HCL INFINET

MD START UP
105 Phase 1.3 is ready. 106 Regional restart phase 1 is ready. 11x Start after data reload is ready. To be able to keep information about the last restart x will not be overwritten by a start after data reload.

TSG - NOIDA

HCL INFINET

4)Command syntax
2

CA
1

DA

1) COMMAND GROUP 2 )FUNCTION NEED IN THAT PARTICULAR GROUP 3) OPERATION WANTED

TSG - NOIDA

HCL INFINET

4)COMMAND GROUP 3
       P I E S C R T PRINTOUT INITIATE END / ERASE SET CHANGE REMOVE TRANSFER

TSG - NOIDA

HCL INFINET

SYNTAX
 , -> Separates parameter from one another  & -> Separates value in a parameter ,e.g 200&300  && -> separates start and stop value for consecutive series e.g 100&&200  : ->separates command and parameter part  ; -> terminates a command in the following slides I have mentioned L-M-S-P L --->LIM,M--->Magazine ,S--->Slot ,P--->Port

TSG - NOIDA

HCL INFINET

CNBIP

Configuration board R-state information print

 CNBIP:LIM=X;  CNBIP:BPOS=L-M-S; Example:  CNBIP:LIM=1;  CNBIP:BPOS=1-0-30; The command is used to print the product number and R-state of one or more device boards in one or more LIMs

TSG - NOIDA

HCL INFINET

CNBOE Configuration board end

CNBOE:BPOS=L-M-S; Example: CNBOE:BPOS=1-0-20;

The command is used to idle-mark specified board positions in the system

TSG - NOIDA

HCL INFINET

CNHUI

Configuration hardware update initiate

CNHUI:BPOS=L-M-S; Example CNHUI:BPOS=1-0-40; After this command on the screen u can see ORDERED Please wait for a minute or 2 then type ; on the screen u can see

New hardware found .

TSG - NOIDA

HCL INFINET

5) Extension related command


Before initiating any port in MD110 ,we have to tell to the system about the number series we are going to use for extension ,for trunk etc

So the command NANSI is the most important command in MD110

TSG - NOIDA

HCL INFINET

NANSI Number analysis number series initiate


FORMAT NANSI :NUMTYP=,NUMSE=...; NUMTYP = Number type. EX extension number OC -- operator common OI -- operator individual AC -- abbrevaited common AI -- abbrerviated individual ED external destination DI -- DISA. NUMSE = Number series. Any number series EXAMPLE NANSI :NUMTYP=EX,NUMSE=2000&&2099;

TSG - NOIDA

HCL INFINET

NANSI Number analysis number series initiate


FORMAT NANSI :NUMTYP=,NUMSE=...; NUMTYP = Number type. EX extension number OC -- operator common OI -- operator individual AC -- abbrevaited common AI -- abbrerviated individual ED external destination DI -- DISA. NUMSE = Number series. Any number series EXAMPLE NANSI :NUMTYP=EX,NUMSE=2000&&2099;

TSG - NOIDA

HCL INFINET

Number initiate
To initiate a extension number series NANSI :NUMTPY=EX,NUMSE=2001&&2004 ; NANSI :NUMTPY=EX,NUMSE=2006&&2016 ; NANSI :NUMTPY=EX,NUMSE=2050&&2065 ; EXTERNAL DESTINATION CODE NANSI :NUMTPY=ED,NUMSE=0&1; OPERATOR COMMON NUMBER SERIES NANSI :NUMTPY=OC,NUMSE=9; 9

TSG - NOIDA

HCL INFINET

NADAP
NADAP; NUMBER ANALYSIS DATA TYPE OF SERIES NUMBER SERIES EXTENSION NUMBER SERIES 2001 - 2004 2006 - 2016 2050 - 2065 EXTERNAL DESTINATION CODE 01 9

OPERATOR COMMON NUMBER SERIES

TSG - NOIDA

HCL INFINET

CDCAT
 CDCAT---Call discrimination category data NACDS:CDCAT=X,NUM=X&Y&Z&J..; EX: NACDS:CDCAT=1,NUM=1&2&3&4&5&9; This cmd define the starting digits the extension which is owning this CDCAT can able to dial after getting the dial tone..

TSG - NOIDA

HCL INFINET

CDCAT
After Giving NADAP ,u can see the output according to ur NACDS COMMAND . It will look like the following .  EXTERNAL/INTERNAL NUMBER CAT  000 4  001 4 2  002 4 3  003 4 3  004 4 2  005 4 3  006 4 3  007 4 3  008 4 2  009 4 3

TSG - NOIDA

HCL INFINET

CDCAT
The above slide define the extension which is having CDCAT 4 can dial 000 to 009(STD calls ,here the first 0 is the DEST ie.. Route access code ) The extension which is having CDCAT 3 can dial 002 , 003,005,006,007. According to the customer need u have to define the cdcat . the cdcat will be mapped to traf parameter of EXCCS ,the next slide will define that .

TSG - NOIDA

HCL INFINET

CDCAT

TSG - NOIDA

HCL INFINET

CAT-category
EXCCS:CAT=X,SERV=D1-D10,TRAF=D1-D8,CDIV=D1-D9,ROC=D1-D6; EXAMPLE: EXCCS:CAT=0,SERV=0202120700,TRAF=00151515,CDIV=011141111,ROC=00 0001; This command groups the following category to the cat 0 SERV=SEVICE CATEGORY S4 S1 S2 S3 TRAF=TRAFFIC CATEGORY ROU=ROUTE CATEGORY

Traf R1 R2 R3 R4

CDIV=CALL DIVERSION CATEGORY

C1

C2

TSG - NOIDA

HCL INFINET

CAT,CDCAT DIFF
Do not get confused with cat and cdcat . Cat means the category just like COS in BP250 ,it includes the services the extension can enjoy ,traffic (TCD) of the extension ,diversion related features and other facilities like intrusion ,call back etc. CDCAT defines only the starting digit the extension can dial after getting the dial tone .As mentioned above the cdcat will be mapped to CATS TRAF parameter.

TSG - NOIDA

HCL INFINET

ALALOG EXTENSION
Extension Initiate
EXTEI:TYPE=XXXX,DIR=XXXX,EQU=L-M-S-P,CAT=X; EXAMPLE: EXTEI:DIR=2016,TYPE=ELU6,EQU=1-0-3-10,CAT=0; Type ELU 6 ANALOG EXT DIR - ANY EX NUMBER WHICH IS INITIATED IN NUMBER SERIES EQU- EQIUPMENT POSITION CAT CATEGORY

TSG - NOIDA

HCL INFINET

TO CHANGE THE CATEGORY

 EXCAC:DIR=XXXX,CAT=X; EXAMPLE: EXCAC : DIR=2016,CAT=3;

TSG - NOIDA

HCL INFINET

PRINT COMMANDS

EXCCP Extension Common Category Code Print EXCCP:CAT=0; EXCAP Extension Category Print EXCAP:DIR=2000; EXDDP Extension Directory Data Print EXDDP:DIR=ALL; EXDNC Extension directory Change EXDNC:DIROLD=XXXX,DIR=XXXX;

TSG - NOIDA

HCL INFINET

END EXTENSION

 EXTEE

Extension End

 EXTEE:DIR=XXXX; EXTEE:DIR=2016;

TSG - NOIDA

HCL INFINET

DIGITAL EXTENSION
KSEXI Key system extension initiate

KSEXI:DIR=XXXX,CAT=X,ITYPE=XX,EQU=L-M-S-P; EXAMPLE: KSEXI:DIR=2001,CAT=0,ITYPE=20,EQU=1-0-10-4; ITYPEINSTRUMENT TYPE

I TYPE

TSG - NOIDA

HCL INFINET

CHANGE
KSCAC Key system category change EX: KSCAC:DIR=XXXX,CAT=X; KSDNC Key system directory number change EX:KSDNC:DIROLD=XXXX,DIR=XXXX;

TSG - NOIDA

HCL INFINET

PRINT COMMAND
KSCAP Key system category print EX:KSCAP:DIR=XXXX; KSDDP Key system directory data print EX :KSDDP:DIR=ALL;

TSG - NOIDA

HCL INFINET

6)Feature activation  Abbreviated number is of two types  i) Individual abbreviated number  ii) common abbreviated number
The Common Abbreviated dialing facility enables voice and individual PABX operators to dial a common abbreviated number instead of a complete number. The individual abbreviated dialing facility enables users to dial individual abbreviated numbers instead of a complete number.

TSG - NOIDA

HCL INFINET

Common abbreviated number


Initiation ADCOI:ABB=XX,TRA=XXXX,CLASS=; Example : ADCOI:ABB=34,TRA=09818959582,CALSS=1&&3; END ADCOE:ABB=; Example ADCOE:ABB=34; PRINT ADCDP:ABB=;

TSG - NOIDA

HCL INFINET

Individual Abbreviated number


Initiate ADINI:DIR=XXXX; To use dial **<digit> To program Dial *51*<digit(0-9)>*<telephone number># To erase Dial #51*<digit(0-9)>#

TSG - NOIDA

HCL INFINET

Individual Abbreviated number

End ADINE:DIR=XXXX; Print ADIDP:DIR= XXXX;

TSG - NOIDA

HCL INFINET

CALL DIVERSION

Call diversion is of two types i) common call diversion ii) individual call diversion D4 D9 bits in SERV parameter decides the type of call diversion

TSG - NOIDA

HCL INFINET

Call diversion (common) CDCOI:INTDIV=09; To set : *21# To Reset : #21#

TSG - NOIDA

HCL INFINET

Individual call diversion

Initiate CDINI:DIR=XXXX,DIV=YYYY; Example : CDINI:DIR=2897,DIV=2345; End CDINE:DIR=XXXX; Print CDIDP:DIR=XXXX;

TSG - NOIDA

HCL INFINET

CALL PICKUP

i) Individual call pick up ii) Group call pick up To initiate call pick up dial the extension number where the call is ringing and press 8

TSG - NOIDA

HCL INFINET

Call pick up
GPGMI Group call pickup member initiate

GPGMI:GRP=XXXX,DIR=XXXX&YYYY; Example: GPGMI:GRP=234,DIR=3456&3563; To pick up Assign in the command NASCS:AGP=XX;

TSG - NOIDA

HCL INFINET

Hunt group
GHGRI Group hunting group initiate GHGRI:GRP=XXXX,SERV=D1-D5,TRAF=D1D2,SEL=D1D6,QUE=X; Example: GHGRI:GRP=1550,SERV=10010,TRAF=15,SEL=110002, QUE=10; Parameters: SERV SERV TRAF TRAF S1 S2 SEL

TSG - NOIDA
HUNT GROUP

HCL INFINET

GHGMI

Group hunting group member initiate

GHGMI:GRP=XXXX,DIR=XXXX&&YYYY; Example GHGMI:GRP=1550,DIR=2356&&2378;

TSG - NOIDA

HCL INFINET

ENDING

GHGRE Group hunting group end GHGRE:GRP=XXXX;

GHGME Group hunting group member end GHGME:GRP=XXXX,DIR=XXXX;

TSG - NOIDA

HCL INFINET

DUMPING BACKUP
There are three directories on external backup used for loading and to which dumping takes place -one initial load directory (INL) and two reload directories (REL1 and REL2) System dump means that a backup of program code and exchange data is created or updated. The system dump is always done by overwriting the oldest version.

TSG - NOIDA

HCL INFINET

DUMPING BACKUP
 DUSYI Dumping system initiate DUSYI:DUMP=ALL;

DUBDP Dumping backup data print DUBDP;

TSG - NOIDA

HCL INFINET

7)VOICE MAIL
Hardware required : 1) Intel dialogic card 2) Amdale or Diavox software,license 3) according to number of port in dialogic ,we need to spare the same number of analog extension (Elu-29) 4) Pc with 256 MB RAM and also with 2 com port

TSG - NOIDA

HCL INFINET

7)VOICE MAIL
One I/O port should be activated to get the strings from M110 ,the command is IOEQI:IODEV=ANYNAME ,EQU=L-M-S-P,USAGE=OUT; EXAMPLE IOEQI:IODEV=VMAIL,EQU=1-0-60-03,USAGE=OUT

TSG - NOIDA

HCL INFINET

7)VOICE MAIL
As our voice mail is external voice mail ,ie.. It is connected to the external computer ,we have to give a identity to the computer in MD110 where our voice mail is running Cmd:ICFUI:IODEV=VMAIL,UPDFCN=NO,DFMT=5,IFCIN D=1; VMFUI:IFCIND=1,VMS=EXTN2,POFMT=5;

TSG - NOIDA

HCL INFINET

7)VOICE MAIL
Then activate the voice mail extension number by the following command VMPOI:IFCIND=1,DIR=XXXX,PORT=0XXXX; u have to add one more 0 (right padded )in the port parameter because our data format is 5

TSG - NOIDA

HCL INFINET

7)VOICE MAIL
Then create a pbx group and land and divert calls to the voice mail

GHGMI:GRP=XXXX,SERV1000,TRAF=15,QUE=0,SEL=10100; GHGMI:GRP=XXXX,DIR=XXXX; Now a days for voice mail ,Amdale software is coming ,so I am appending its installation manual in this.

TSG - NOIDA

HCL INFINET

Installing PowerConnect Voice Mail

Getting Ready to Install Installing PowerConnect Software Configuring PowerConnect Software

TSG - NOIDA

HCL INFINET

CTI or CT

Computer Telephony Integration. This is the overall term used to describe telephony solutions like Voice Mail, Call Centers, IVR, Fax on demand, etc. This is the computer to which the serial link from the PBX is connected and where PCServer software would be running. This PowerConnect software program is the Server software that needs to be continuously running on the computer to which the serial link from the PBX is connected for any of the products or solutions described in this document to work. This application program keeps a check on PCServer operations, and when a problem occurs, it rectifies the fault or re-starts the PCServer software or re-boots the computer, to ensure high availability of all CTI operations. Voice Mail system The computer that hosts the VM software.

CTServer

PCServer

PCMonitor

VM VM Computer

TSG - NOIDA

HCL INFINET

Getting Ready to Install


What you need
A computer for VM to run on Dialogic voice cards MD110 PBX Serial link cable to connect the PBX to the VM computer PowerConnect software package, including media CD, hardware license, Getting Started sheet

VM Computer Specification
Ensure a good quality, branded PC. Exact specs depend on system size, but following is minimum for an 8 port system:  PentiumIII, 800 MHz, 256 MB RAM configuration. For higher configuration at least 512MB RAM is required).  10 GB hard disk  color monitor, Keyboard, Mouse  CDROM Drive, 1.44 MB floppy drive  Sound card, Mike  2 serial ports, 1 parallel port, LAN card (if network services are required)  Free full-length PCI slots (exact number dependent on the number of Dialogic cards in the system).  Operating system must be W in NT 4.0, 2000, or XP with latest service packs

Pre-Install Steps & Confirmations


Ensure that the operating system of the VM computer is correct. Ensure that the Dialogic that you are using is a D4/PCI, D41JCT, D120JCT or VFX. If using any other card please confirm with Amdale before installing. Install the Dialogic card in the PCI slot of the VM computer. Do not install Dialogic drivers from the CD accompanying the Dialogic card, as PowerConnect setup will automatically install the correct driver for you.

Now VM computer is ready to install PowerConnect VM software

TSG - NOIDA

HCL INFINET

Installing PowerConnect Voice Mail

Getting Ready to Install Installing PowerConnect Software Configuring PowerConnect Software

TSG - NOIDA

HCL INFINET

 Insert the PowerConnect Setup CD into the CD-drive of the VM computer.  The setup program will start automatically, and you will see the picture shown on the left. If setup doesnt start automatically, then run program d:\setup.exe where d: is the drive letter of your CD-drive.  In a little while, this message will disappear, and you will move to step 2.

Step 1

TSG - NOIDA

HCL INFINET

Welcome message   This is the setup introduction form. Read and click Next if you agree.

Click Next

Step 2

TSG - NOIDA

HCL INFINET

Software License Agreement  Please read carefully, and If you agree, then click Yes; else click No to terminate setup.

Click Yes if agree Step 3

TSG - NOIDA

HCL INFINET
Information message screen  This screen warns you that by proceeding further, you will overwrite any previous installation of PowerConnect. If this is the first time you are installing PowerConnect on this computer, then ignore this message, and click OK. If an installation of PowerConnect already exists on this computer, please be sure that this is what you want to do, and only then click OK.

Click OK

Step 4

TSG - NOIDA

HCL INFINET

User Information screen  Fill in the User & Company name details on this screen and click Next.

Click Next

Step 5

TSG - NOIDA

HCL INFINET

Type of Setup & installation location   Ensure that Typical option is selected Installation directory must be C:\Cworld. If you change any of the above settings, then PowerConnect Voice Mail will not work correctly. Click Next.

Select Typical

 Installation directory must be C:\Cworld 

Click Next

Step 6

TSG - NOIDA

HCL INFINET

PowerConnect Program folder  This is the name of the folder in which PowerConnect applications will be listed in the StartpPrograms list. The default is PowerConnect, but you can set to the name of your choice. Click Next to proceed further.

Click Next

Step 7

TSG - NOIDA

HCL INFINET

Confirmation of Currently Selected settings  On this screen ensure that you see exactly what you see in the picture on the left except for the User & Company Name. W hen you are ready click Next to start copying files. This is the last screen before setup starts copying files.

Click Next Step 8

TSG - NOIDA

HCL INFINET

File Copying Progress screen  PowerConnect Setup is now copying files. In a little while, when the progress bar reaches 100%, this screen will automatically disappear. At that time, proceed to the next step.

Step 9

TSG - NOIDA

HCL INFINET
Intel-Dialogic files copying screen  PowerConnect Setup automatically installs Intel Dialogic driver files. If you remember, when you installed the IntelDialogic card, you did not install its drivers. The reason for that is that often the drivers CD accompanying the card is older, thus causing problems on site. PowerConnect setup ensures that the latest files are copied.  This screen indicates that these files are now being copied.  In a little while, when the progress bar reaches 100%, this screen will automatically disappear.  At that time, proceed to the next step.

Step 10

TSG - NOIDA

HCL INFINET

Setup Completed  On this screen, you are prompted to re-start the VM computer. It is necessary to restart at this time. Click Finish. W hen the computer has rebooted, please login, and move onto Configuring VM Software sections.

 

Click Finish

You have successfully installed PowerConnect VM software


Step 11

TSG - NOIDA

HCL INFINET

Installing PowerConnect Voice Mail

Getting Ready to Install Install PowerConnect software Configuring PowerConnect Software

TSG - NOIDA
PowerConnect Client program

HCL INFINET

All configuration parameters are set by using

This application program is installed automatically when you ran the PowerConnect Setup program. To start PowerConnect Client program, choose menu option: StartpProgrampPowerConnectp Client

Click on Client

TSG - NOIDA
Please follow the steps below
The form shown in the left will show up when you started PowerConnect Client on the previous page. Login using the following user information: Username: system Password: sys

HCL INFINET

Start by running PowerConnect Client Main Screen

This screen is called


Click here

PowerConnect Client Main Screen

PowerConnect Client options screen Click on Design Call Flows option

TSG - NOIDA

HCL INFINET

PowerConnect Client program is very extensive, and is used to set properties of all PowerConnect applications. We will use only some portions of it to set options for VM.

Click next to continue

TSG - NOIDA

HCL INFINET

PBX Configuration & System Parameters

Choose menu item ConfigurationpSystem Parameters on the PowerConnect Client Main Screen. Click on the tab marked PBX 1. The form alongside will show up. Choose correct PBX from the drop down list (in this case Ericsson MD110). Stay on this form

TSG - NOIDA

HCL INFINET

PBX Configuration & System Parameters

Click on the tab marked PBX 2. Choose V.24 as the PBX integration type. Select the COM port of your choice. This is the port that you will connect to the PBX with a serial cable. Stay on this form

TSG - NOIDA

HCL INFINET
Click on the tab marked Telephone Line Configuration Configure the PBX extension numbers of the analog phone lines connected to the Dialogic card on the VM computer (these extensions should be configured as voice mail extensions on the PBX). Connection diagram shown in below right. Enable some of the lines for dialing out (Reqd. for notifications) Now click on the button marked Save to save your changes and exit.

PBX Configuration & System Parameters

V.24 Link

The extns being configured here are the ones connected to the Dialogic card as shown

PBX

CTI Server
Telephony cards PBX extns connected to voice mail

TSG - NOIDA
Configuring User Mailboxes

HCL INFINET

Choose menu item ConfigurationpMailbox Parameters on the PowerConnect Client Main Screen and you will see the picture shown on the left. For each mailbox, please configure all the needed information. Note that many fields are optional, depending upon your requirements. Description of these fields is shown at the end of the document. You can add new mailboxes by typing in the last row of this form. You can delete mailboxes by selecting the whole row and clicking the Del key on the keyboard. This form comes pre-filled with some mailboxes, to give you an idea of how to fill them. If they are not needed, please delete them. You can also bulk assign mailboxes. Information for that is available on the next page W hen done, click on the cross button on the top right corner of the form to exit.

TSG - NOIDA
Configuring User Mailboxes
Creating Mailboxes in Bulk

HCL INFINET

Select a row and right click using mouse.Selected row will be used as a template for all newly added mailboxes. Choose menu option titled Add Mailboxes Form shown in the lower left corner will appear. Specify range of mailboxes you want to add in bulk. W hen done, click on the cross button on the top right corner of the form to exit.

TSG - NOIDA

HCL INFINET

Enabling Phone Notifications Including phone call & Message Wait Lamp indication on phone set
Select ConfigurepAuto Dialers from the PowerConnect Client Main Screen. Choose auto dialer titled UMS Notifications Ensure that its status is running and not paused. Ensure that lines are specified for Auto dialing. Ensure that Auto Dial is configured for all times. Should show send continuously until done Stay on this form

TSG - NOIDA

HCL INFINET

Enabling Pager Notifications Including numeric paging on your pager set

Choose auto dialer titled PagingDialout Ensure that its status is running and not paused. Exit the form

TSG - NOIDA
Email Notifications

HCL INFINET

Though you can set this feature for any version of PowerConnect Voice Mail, it will be enabled on the PowerConnect Server in PowerConnect VM Professional only.
Select ConfigurepSystem Parametersp Server & Emails from the PowerConnect Client Main Screen Check the box titled PowerConnect Server should send emails. Fill in the fields titled SMTP Servers TCP/IP Address, POP3 Account Parameters, Username & Password / Confirm Password. This is the email server to which PowerConnect Server will send emails for the users. Save and exit the form Also ensure that email address is filled for all users in the User Mailboxes screen.

 

TSG - NOIDA
Setting the Smart Node Properties

HCL INFINET

W hen the PBX sends call information to the VM computer on the V.24 port, the Voice Mail system can respond automatically by jumping to appropriate paths.

In PowerConnect Client Main Screen select the call flow titled SYS_VoiceMailStandard. Continue to the next page

TSG - NOIDA
Setting the Smart Node Properties
PBX String Type Direct PSTN Direct Internal Diverted on No Answer Diverted on Busy Direct for recording Diverted due to Immediate forwarding Message W aiting ON Call Disconnect Heartbeat Check Message W aiting OFF

HCL INFINET

NTJT 10 75 90 90 90 90 100 100 100 100

Choose menu item MainpSelected Call TreepProperties option. Keep clicking Next until you arrive at the page shown on the left above. Check the option Enable Smart node to option Set the properties in the table in the form as shown in the list on the top on the right. Click Next/Finish to save your changes.

TSG - NOIDA

HCL INFINET

Assigning the Call Flow to Phone Lines


By doing this, you ensure that PowerConnect Server will pick up the phone on each line and respond to the caller correctly

Select menu option MainpAssign Phone Line to call Trees on PowerConnect Client Main Screen. From the drop-down list in each row, assign the call flow Sys_VoiceMail-Standard to the phone lines on which voice mail will run. You can also bulk assign call flows on lines. Click on Bulk Assign button..

TSG - NOIDA
Changing Operator Extension

HCL INFINET

Typically, people dial a 0 or a 9 to connect to the operator of the PBX. PowerConnect ships with 9 as the default setting. If this is different on your PBX, change it using the steps described below.

Ensure that the call flow named SYS_VoiceMailStandard is selected on PowerConnect Client Main Screen. Start the configuration wizard for node number 51 by doubleclicking on the node. Click Next until you see the picture shown on the left. You should see 9 as the current setting. Change this as per your PBXs setting.

TSG - NOIDA
Changing Welcome Greeting

HCL INFINET

To change the greeting played by Voice Mail as soon as a call is received, do the following:

Record the new greeting voice file in Dialogic ADPCM 8khz format using any voice recording software which support this format. Save it as Welcome.vox in the c:\cworld\voice\eng\WelcomePrompt. directory

TSG - NOIDA

HCL INFINET

Changing Hidden Code to Retrieve Messages


W hen mailbox owners call the voice mail system to retrieve their messages, they dial a hidden code to interrupt the auto attendant, and force the VM system into message retrieval mode. PowerConnect ships with 00 as the default setting. If you wants to change it use steps described below . Ensure that the call flow named SYS_VoiceMail-Standard is selected on the PowerConnect Client Main Screen. Start the configuration wizard for node number 21. Click next until you see the form as shown on the left. You should see value 00 in the valid input field against node-to-jump-to 74. Please change this as per your need. Click on Next/Finish buttons to save your changes. Repeat the above steps for node number 31 & 41 as well.

TSG - NOIDA

HCL INFINET

8)Call Information Logging


 connect the login cable from MD110 to the computer where call billing is running


hope all know the installation of call billing software CUBE

After installing the call billing software set the port properly

TSG - NOIDA

HCL INFINET

8)Call Information Logging


The Call Information Logging function permits the recording of all types of call The CIL calls will be temporarily stored in the 10 k buffer. CIL data can be stored in HDU or it can be taken out and given as a input to any billing software to get a report

TSG - NOIDA

HCL INFINET

Call Information Logging


IOEQI:IODEV=any name,EQU=L-M-S-P,USAGE=OUT; Example IOEQI:IODEV=SMDR,EQU=1-0-60-3-,USAGE=OUT; CLDFI Call Logging output Device to output File Initiate CLDFI:FILE=ANYNAME, IODEV= , USER=NONE; Example : CLDFI:FILE=FILE1,IODEV=SMDR,USER=NONE;

TSG - NOIDA

HCL INFINET

Call information logging


CLOHI Call Logging Output Header Initiate

CLOHI:FILE= ,FORM= X,DMPSIZE= X; Example: CLOHI:FILE=FILE1,FORM=2,DMPSIZ=1;

TSG - NOIDA

HCL INFINET

Call information logging


CLODI Call Logging Output Data Initiate

CLODI:FILE= ,ORIG= , DIAL= ,TIME=H-MM-SS; Example: CLODI:FILE=FILE1,ORIG=2001&&2088,DIAL=0&84,TIM E=0-00-20;

TSG - NOIDA

HCL INFINET

9)ROUTE
ROCAI Route category initiate ROCAI:ROU=XX,SEL=D1-D16,TRAF=D1D8,TRM=4,SIG=D1-D12,SERV=D1-D10; Example: ROCAI:ROU=24,SEL=7130000010000010,SERV =3100000000,TRAF=00151515,TRM=4,SIG=2000 01000000;

TSG - NOIDA

HCL INFINET

ROUTE
RODAI Route data initiate Syntax: RODAI:TYPE=XXXX,VARC=D1-D8,VARO=D1D8,VARO=D1-D8;

TYPE: TL22 ----- E&M TL11 ----- Analogue Trunk SL60 ----- BRI/PRI

TSG - NOIDA

HCL INFINET

ROUTE
Example configurations for different lines Analogue Trunk: RODAI:TYPE=TL11,VARC=00000022,VARI=00000408, VARO= 00000705; PRI- Q-sig RODAI:TYPE=SL60,VARC=00000310,VARI=15400000, VARO= 06300000; BRI : RODAI:TYPE=SL60,VARC=00000204,VARI=00000001, VARO=40004001; E&M RODAI:TYPE=TL22,VARC=021F1032,VARI=00012040, VARO= 00001000;

TSG - NOIDA

HCL INFINET

ROUTE
RODDI Route external destination data initiate

RODDI:ROU=X,DEST=0,SRT=2; SRT-Start position for digit transmission

TSG - NOIDA

HCL INFINET

ROUTE
ROEQI Route equipment initiate ROEQI:ROU=X,TRU=1-1&&1-8,EQU=L-N-S-P; TRUTRUNK LINE NUMBER

TSG - NOIDA

HCL INFINET

ROUTE
PRINT COMMANDS ROCAP:ROU=XX; RODAP:ROU=XX; RODDP:DEST=ALL; ROEDP:ROU=XX,TRU=ALL;

TSG - NOIDA

HCL INFINET

NUTRI

Number conversion initiate

NUTRI:CNVTYP=0,NUMTYP=4,TRC=X,PRE=X,ENTRY= XXXXXXXX; CNVTYP-conversion type 0 received number 1 sent number NUMTYP- number type 4- local public number

TSG - NOIDA

HCL INFINET

10)Mobility
 Common Fixed Part ELU31 board with firmware.  Fixed Part Everything between the GDI and the air interface.  IPEI Global unique identity. It is hard coded in the Portable Part.  Location Area The domain in which a PP may receive (and/or make) calls as a result of a single location registration.  Radio Fixed Part Radio base station.  GDI Generic DECT interface

TSG - NOIDA

HCL INFINET

TSG - NOIDA

HCL INFINET

GENERIC EXTENSION
Unlike a traditional extension which is affiliated to an equipment position a generic extension is affiliated to a LIM

To a generic extension a number of categories are affiliated. Those categories are collected in a number of Common Service Profiles (CSP) and to every generic extension a CSP must be affiliated.

TSG - NOIDA

HCL INFINET

MOBILITY-COMMANDS
GESPI Generic extension common service profile initiate Example: GESPI:CSP=X,TRAF=D1- D10, SERV=D1 TO D13, CDIV=D1-D8, ROC=D1-D6, NPRES= D1-D4; TRAF
T1 T2 S2 S3 S4 S5

SERV CDIV ROC NPRES

S1

C1 R1

C2 R2 R3 R4

N1

TSG - NOIDA

HCL INFINET

GENERIC EXTENSION
Initiate extension
GEDII:DIR=XXXX; PRINT GEDIP:DIR=XXXX;

TSG - NOIDA

HCL INFINET

MOBILITY-COMMANDS

CXSYI

Cordless extension system data initiate

Example: CXSYI:SARI=XXXXXXXX;

TSG - NOIDA

HCL INFINET

MOBILITY
CXCFI Cordless extension common fixed part initiate CXCFI:BPOS=L-M-S-P,FPI=X; CXCFP Cordless extension common fixed part print CXCFP:FPI=X; CXCFE Cordless extension common fixed part end CXCFE:FPI=X;

TSG - NOIDA

HCL INFINET

MOBILITY
CXRFI Cordless extension radio fixed part initiate CXRFI:FPI=X,RPN=X; CXRFP Cordless extension radio fixed part print CXRFP:FPI=X.RPN=X; CXRFE Cordless extension radio fixed part end CXRFE:FPI=X,RPN=X;

TSG - NOIDA

HCL INFINET

MOBILITY
CXAKI Cordless extension authentication key initiate CXAKI:DIR=XXXX,AUTHKEY=XXXX,IPEI= ; CXAKP Cordless extension authentication key print CXAKP:DIR=XXXX; CXAKE Cordless extension authentication key end CXAKE:DIR=XXXX;

TSG - NOIDA

HCL INFINET

11)Trace
So often if u have a problem in installation ISDN PRI line ,to get it rectified we need the trace of it ,so I will explain how to take trace. STISR; To cmd is to clear the memory .

TSG - NOIDA

HCL INFINET

Trace
STISR; STUNI:LIM=X,UNIT=SLP60;(FOR ISDN BRI/PRI) The md110 will give u TRI number STTSI:TRI=X; Make one incoming or outgoing call using that pri line STTSE:TRI=X; PRESS F8 to create a log file Then give STRAP:TRI=1; After this close the log file ,send the log file to us.

TSG - NOIDA

HCL INFINET

Conclusion
Hope I had given you nice repast . send your feedbacks to telesupp@hclinsys.com mkhanka@hclinsys.com skrai@hclinsys.com vcmouli@hclinsys.com